Sutures are medical devices used to close wounds or surgical incisions in horses. They are typically made from materials such as nylon, polypropylene, or absorbable polymers and are selected based on the specific requirements of the wound or procedure. Sutures serve to approximate tissue edges, promote healing, and reduce the risk of infection. In equine medicine, the choice of suture material, technique, and pattern can significantly affect the healing process and the outcome of surgical interventions. This page compiles peer-reviewed research studies and scholarly articles that examine the types, applications, and outcomes of suture use in equine veterinary practice.
Maninchedda U, Nottrott K, Gangl M.This retrospective study on 37 horses was conducted to assess long-term complications, scarring, cosmetic appearance and owner satisfaction of horses that underwent transpalpebral enucleation with (n=26) or without (n=11) non-absorbable sutured meshwork prosthesis between 2006 and 2013. Postoperative complications related to the surgery were wound infection, discharge and dehiscence, and no significant difference between groups was found. In one horse, the meshwork had to be removed in order to treat a chronic fistula. Horses with infection or inflammation before surgery were more likely to en...
Azizi S, Hashemi-Asl SM, Torabi E.Surgical treatment of traumatic abdominal hernias is usually delayed for 2-3 months following injury. The residual defects are then repaired by herniorrhaphy or mesh herniorrhaphy. Objective: To describe the outcome following herniorrhaphy (without a mesh) within 21 days of initial injury to repair external traumatic lateral abdominal hernias in horses and mules. Methods: Descriptive case series. Methods: Twenty-two cases were included. Surgical treatment involved exposure of the hernia sac and closing of the abdominal wall defect with interrupted Mayo mattress or cruciate sutures after redu...
McMaster MA, Munsterman AS, Weimar WH, Barrett EJ, Hanson RR.To compare the load to ultimate failure, load to a 2 mm gap, mode of failure, and gap at failure (mm) of the Teno Fix(®) (TF) to the 3-loop pulley (3LP) for repair of equine tendon lacerations. The use of 4TF devices versus 5TF devices on load to ultimate failure and load to a 2 mm gap was also compared. Methods: Ex vivo biomechanical study; unbalanced incomplete block (horse) design. Methods: Cadaveric equine forelimb superficial digital flexor tendon (n = 20 paired tendons). Methods: Ten tendon pairs were selected randomly and repaired with a 3LP and 4TF pattern, and 10 tendon pairs...
Sanders RE, Kearney CM, Buckley CT, Jenner F, Brama PA.To evaluate knot security for 3 knot types created in 3 commonly used 5 metric suture materials incubated in physiological and pathological fluids. Methods: In vitro mechanical study. Methods: Knotted suture loops (n = 5/group). Methods: Loops of 3 different suture materials (glycolide/lactide copolymer; polyglactin 910; polydioxanone) were created around a 20 mm rod using 3 knot types (square [SQ], surgeon's [SK], and triple knot [TK]) and were tested to failure in distraction (6 mm/min) after tying (day 0) and after being incubated for 14 and 28 days in phosphate buffered saline (PBS...
Santos MP, Gutierrez-Nibeyro SD, Horn GP, Hicke JD, Stewart MC, Schaeffer DJ.To compare the mechanical properties of laryngeal tie-forward (LTF) constructs prepared with different suture materials and suture placement patterns during single load to failure testing. Methods: Larynges harvested from 50 horse cadavers and 5 intact horse cadavers. Methods: In vitro LTF constructs were created by a standard technique with polyester sutures, a standard technique with polyethylene sutures, a modified technique with metallic implants and polyester sutures, a modified technique with metallic implants and polyethylene sutures, or a modified tie-off technique with polyester sutur...
Anderson SL, Devick I, Bracamonte JL, Hendrick S, Barber SM, Carmalt JL, Wilson DG.To report the occurrence of, and risk factors associated with, incisional complications of equine ventral median celiotomies closed with USP 7 polydioxanone (7PD). Methods: Retrospective case series. Methods: Horses (n = 73; 75 celiotomies). Methods: Medical records (2000-2010) were retrieved and reviewed for horses that had a ventral celiotomy closed with 7PD and survived ≥14 days. Follow-up (>1 year) was obtained from the medical record, owner, or referring veterinarian. Independent variables were selected based on risk factors identified in previous studies, perceived clinical relevan...
Gandini M, Giusto G, Comino F, Pagliara E.In literature only one article describes and compares methods of achieving hemostasis in equine mesenteric arteries during jejunal resection and anastomosis, and most textbooks favor ligating-dividing mechanical devices. The latter method cannot always be used, not least because the devices are expensive and in some cases even contra-indicated. Various types of knots, including sliding knots, are widely used to provide hemostasis in laparoscopy. Methods: Portions of jejunum with associated mesenteric vessels were collected from 12 horses at a local abattoir. These were divided into 24 specimen...
König L, Klopfleisch R, Kershaw O, Gruber AD.The formation of biofilms on surgical implants is thought to play a major role in chronic infection and wound-healing disorders and has been rarely described in veterinary medicine. Due to poor and unreliable results from bacterial culturing, histology may be an economic tool for the detection of biofilms. In this study, the prevalence of biofilms on surgical suture materials and swabs with chronic wound-healing complications in dogs, cats, and horses was assessed by histologic examination using hematoxylin and eosin, Gram, and Giemsa stains, as well as periodic acid-Schiff reaction. Of the 91...
Willsallen H, Heller J, Kark L, Hilbert BJ.In vitro comparison of the mechanical properties of braided polyurethane elastomer (Lycra®) and braided polyester (Ethibond™) (1) when inserted into the muscular process of the arytenoid cartilage and (2) as suture loops. Methods: Experimental. Methods: Equine cadaver larynges (n = 15). Methods: The muscular processes (n = 30) of the arytenoid cartilages were dissected from each larynx and embedded in a resin base. Lycra® and Ethibond™ prostheses were randomly allocated to the left or right muscular process and each underwent cyclic fatigue (25-50 N) followed by load-to-failure...
Santos MP, Gutierrez-Nibeyro SD, Horn GP, Johnson AJ, Stewart MC, Schaeffer DJ.To compare the mechanical properties of laryngeal tie-forward (LTF) surrogate constructs prepared with steel fixtures and No. 5 braided polyester or braided polyethylene by use of a standard or a modified suture placement technique. Methods: 32 LTF surrogate constructs. Methods: Surrogate constructs were prepared with steel fixtures and sutures (polyester or polyethylene) by use of a standard or modified suture placement technique. Constructs underwent single-load-to-failure testing. Maximal load at failure, elongation at failure, stiffness, and suture breakage sites were compared among constr...
Barrett EJ, Munsterman AS, Hanson RR, Jackson RL.To compare in vitro strength and failure characteristics of a tendon implant against a 3 loop pulley suture pattern for equine superficial digital flexor tendon (SDFT) laceration repair. Methods: Experimental. Methods: Cadaveric equine forelimb SDFT (n = 16). Methods: One tendon of each of 8 pair of SDFT was randomly selected for repair with either the 3-loop pulley (3LP) suture pattern using 2 polydioxanone or with 4 stainless steel suture and anchor implants (SA). Ultimate load to failure, mode of failure, gap at failure, and load to 2 mm gap were obtained using a materials testing sys...
Anderson SL, Bracamonte JL, Hendrick S.The objective of this study was to compare the bursting strength (BS) and mode of failure (MF) of ventral midline (VM) celiotomies closed with USP 7 polydioxanone (7PD) in 1 or 2 simple continuous sections. A bursting strength model, consisting of inserting and inflating a 200-L polyurethane bladder through a 25-cm VM celiotomy, was used on 15 fresh equine cadavers. Celiotomies were closed using 7PD in 2 separate sections (4 knots), 2 continuous sections (3 knots), or a single section (2 knots) using a simple continuous pattern. The horses' signalment, body weight, number of total knots, MF, a...
Aristizabal FA, Lopes MA, Silva A, Avanza MF, Nieto JE.To evaluate the effect of onlay mesenteric flaps (MFs) with end-to-end jejunojejunostomy on stomal diameter, length of jejunum with reduced stomal diameter, abdominal adhesion formation, and healing. Methods: Experimental study. Methods: Healthy adult horses (n = 6). Methods: Two hand sewn end-to-end jejunal anastomoses using a 1 layer simple continuous serosubmucosal suture pattern were performed in each horse ∼ 2 and 5 m oral to the ileocecal fold. Using a random design for selection anastomosis location (oral or aboral), 1 anastomosis was covered with 2 adjacent onlay MFs secured with int...
Nelson BB, Hassel DM.To compare a unidirectional barbed suture (V-Loc™) to its suture material equivalent (Biosyn™) in a single-layer end-to-end anastomosis of equine jejunum. Methods: Experimental in vitro study. Methods: Jejunal sections from adult horses (n = 5) without gastrointestinal disease. Methods: Jejunal end-to-end anastomoses (n = 9) were performed for each group (V-Loc™, Biosyn™) with a continuous Lembert pattern with an interruption every 120°. Anastomosis construction time, luminal diameter, and number of suture bites were recorded. Anastomosis constructs were distended with fluid at 1 L/mi...
Kearney CM, Buckley CT, Jenner F, Moissonnier P, Brama PA.Selection of suture material in equine surgery is often based on costs or subjective factors, such as the surgeon's personal experience, rather than objective facts. The amount of objective data available on durability of suture materials with regard to specific equine physiological conditions is limited. Objective: To evaluate the effect of various equine physiological and pathological fluids on the rate of degradation of a number of commonly used suture materials. Methods: In vitro material testing. Methods: Suture materials were exposed in vitro to physiological fluid, followed by biomechan...
Colbath AC, Patipa L, Berghaus RD, Parks AH.Incisional complications following exploratory celiotomy increase morbidity, extend hospitalisation and increase cost. Retrospective studies seek to identify risk factors and measures for prevention of surgical site infection. The relatively high incidence of incisional complications following exploratory laparotomy necessitates identification of ideal surgical closure methods. Objective: The study sought to identify the incidence of incisional drainage within our hospital population, and to identify risk factors for incisional complications while determining surgical practices that reduce the...
Röcken M, Mosel G, Barske K, Witte TS.To describe successful repair of a diaphragmatic hernia in a standing sedated horse using a minimally invasive thoracoscopic technique. Methods: Clinical report. Methods: Warmblood mare with a diaphragmatic hernia. Results: An 18-year-old Warmblood mare with severe colic was referred for surgical treatment of small intestinal strangulation in a diaphragmatic defect. Twelve days after initial conventional colic surgery, left-sided laparoscopy in the standing sedated mare for diaphragmatic herniorrhaphy failed because the spleen obscured the hernia. One week later, a left-sided thoracoscopy was ...
Anderson SL, Bracamonte JL, Hendrick S, Carmalt JL, Wilson DG.To compare bursting strength and failure mode between ventral median celiotomies closed with USP 7 braided polydioxanone (7PD) or USP 2 polyglactin 910 (2PG). Methods: Ex vivo experimental. Methods: Equine cadavers (n = 10). Methods: A 25 cm ventral median celiotomy was created in fresh equine cadavers. A 200 L polyurethane bladder was inserted into the abdomen. Celiotomies were closed in a simple continuous pattern with 2 sections of 7PD or 2PG. The bladder was inflated with compressed air until construct failure. The horses' signalment, body weight, suture type, failure mode (suture or abdom...
Ragle CA, Yiannikouris S, Tibary AA, Fransson BA.A 4-year-old castrated Arabian horse was evaluated for a history of a right-sided nonstrangulating inguinal hernia that was manually reducable. Results: Physical examination revealed a right-sided hydrocele and bilateral enlargement of the inguinal rings detectable by both external digital and rectal palpation. Results: Biportal laparoscopic internal inguinal ring closure was performed with a continuous suture line of unidirectional barbed suture applied with a mechanical suturing instrument. The barbed suture contributed to a secure closure with the added benefit of not requiring knots to be ...
Ahern BJ, Boston RC, Parente EJ.Mechanical evaluation of a novel alternate laryngoplasty system (ALPS). Methods: Experimental. Methods: Cadaveric horse larynges (n = 10). Methods: Arytenoid and cricoid cartilages were embedded for testing. A novel laryngoplasty system consisting of a metallic anchor, 2 stands of #2 suture material, and a metallic button were evaluated. A traditional laryngoplasty using a single strand of #5 Ethibond was evaluated in parallel. Constructs were evaluated in cyclic testing oscillating from 30 to 50 N for 3600 cycles. Constructs subsequently underwent a single cycle to failure. Distraction during...
Rossignol F, Ouachée E, Boening KJ.To describe a modified laryngeal tie-forward procedure (LTFP) using metallic implants. Methods: Retrospective case series. Methods: Twenty-seven horses (including 24 race horses) with dorsal displacement of the soft palate (DDSP) or palatal instability (PI) diagnosed using high-speed treadmill endoscopy (n = 15), history and resting examination (n = 8), or dynamic endoscopy over ground (n = 4). Methods: All horses underwent the modified LTFP. Modifications of the surgical procedure consisted in the use of 3 metallic stents called Suture Button(TM) through which the sutures are threaded and in ...
Tsujita H, Brennan AB, Plummer CE, Nakajima N, Hyon SH, Barrie KP, Sapp B, Jackson D, Brooks DE.Chemically defined bioadhesives (CDB) are "two-component reactive adhesives" made from antibiotic food additives. They contain no animal-derived ingredients and are characterized by a high level of self-degradability, low toxicity, and strong bonding properties. Amniotic membrane (AM) transplantation is used to repair severe ocular surface disease in humans and horses. AM requires meticulous suturing to the injured cornea. The purpose of this study is to determine whether CDB can facilitate the suture-less placement and adherence of equine AM to porcine cadaver cornea. Methods: Prospective stu...
Auletta L, Lamagna F, Uccello V, Lamagna B, Pasolini MP.The equine small intestine can be affected by a variety of disorders that may require some form of bypass or anastomosis. Many suture patterns have been used in equine anastomoses to minimise post operative complications, which include leakage from the anastomosis site, stenosis and adhesions. Because of the critical condition of horses undergoing colic surgery, it is imperative this is performed as quickly as possible. Objective: To evaluate, in vitro, differences in the time of execution and leakage pressure between the Lembert single layer, Gambee and Lembert double layer suture patterns fo...
Everett E, Barrett JG, Morelli J, DeVita R.To compare in vitro biomechanical properties of a novel suture pattern to a current standard for primary repair of equine superficial digital flexor tendon (SDFT) laceration. Methods: In vitro randomized, paired design. Methods: Cadaveric equine forelimb SDFT (n = 24). Methods: The 3-loop pulley (3LP) and 6-strand Savage (SSS) suture patterns were applied to transected equine SDFT. Ultimate failure load, stiffness, mode of failure, and load required to form a 3-mm gap were obtained using a materials testing system and synchronized high-speed video analysis. Statistical comparisons were made us...
Sherlock C, Lee W, Mueller PO, Eggleston R, Epstein K.Although single layer techniques are preferred in man and small animals for small intestinal end-to-end anastomoses, double layer techniques are more popular in equine surgery. This study was undertaken to evaluate the ex vivo characteristics of 2 single layer anastomoses in comparison to the traditionally performed double layer anastomosis in equine jejunum. Objective: To compare ex vivo: 1) construction time; 2) bursting pressure; and 3) lumen size reduction of 3 suture patterns (double layer simple continuous/Cushing pattern [2C]; single layer Lembert pattern [1L]; and single layer Cushing ...
Smith RL, Murphy DJ, Day RE, Lester GD.To test single cycle to failure tensile strength characteristics of 6 suture material-pattern combinations in equine superficial digital flexor (SDF) tenorrhaphy, specifically to compare a 10-strand modification of the Savage core suture technique with the 3-loop pulley technique. Methods: Ex vivo mechanical experiment comparing 3 different suture patterns with 2 different materials. Methods: Forelimb and hindlimb SDF tendons (n=48) harvested from adult Thoroughbred and Standardbred horses of mixed age and gender. Methods: Six suture material-pattern combinations were evaluated: (1) 10-strand ...
Beard WL, Slough TL, Gunkel CD.Cecal cannulation is necessary for sampling of intestinal contents for a variety of nutritional or digestive physiology studies. This report describes a 2-stage technique for permanent cecal cannulation in standing horses. For the first procedure, a right flank laparotomy is performed and a small pouch of the cecal base exteriorized and sutured to the body wall. The second procedure is performed approximately 1 wk later. During the second procedure, the exposed cecal pouch is removed and the cannula inserted. Ten horses were cannulated using this technique. After the first procedure, 1 horse d...
Witte TH, Cheetham J, Soderholm LV, Mitchell LM, Ducharme NG.To report (1) the force required on a single laryngoplasty suture to achieve optimal abduction of the left arytenoid cartilage, (2) peak forces experienced by the suture during induced swallowing and coughing, and during 24-hour resting activity in a stall, and (3) peak forces during induced swallowing and coughing after left recurrent laryngeal nerve blockade. Methods: Experimental study. Methods: Horses (n=8). Methods: Each laryngoplasty suture was instrumented with an E-type buckle force transducer to measure the force required for optimal intraoperative left arytenoid cartilage abduction. ...
Torfs S, Levet T, Delesalle C, Dewulf J, Vlaminck L, Pille F, Lefere L, Martens A.To assess risk factors for celiotomy incisional infection in horses, especially the use of staples for skin closure. Methods: Case series. Methods: Horses (n=356) that had 1 exploratory celiotomy for colic and survived >2 weeks after surgery between March 1, 2004 and December 31, 2007. Methods: Incisions were classified as "normal" (no complication, only edema, serous drainage lasting <24 hours) or as "surgical site infection (SSI)" (persistent serosanguinous drainage or purulent drainage with or without positive bacterial culture). All possible risk factors, including method of skin closure (...
Bischofberger AS, Brauer T, Gugelchuk G, Klohnen A.Incisional complications are a major post operative challenge following ventral midline exploratory celiotomy for abdominal pain in horses. They lead to discomfort, prolonged hospitalisation, longer recovery times and increased cost; therefore, investigation of preventative procedures are warranted. Objective: To determine the clinical effect of antibacterial (triclosan) coated 2-0 polyglactin 910 suture material on the likelihood of incisional infections when used for closure of subcutaneous tissue following ventral midline celiotomies in horses. Methods: One hundred horses undergoing explora...
Young RL, Snyder JR, Pascoe JR, Olander HJ, Hinds DM.Six enterotomies 3 cm long, spaced at 3 cm intervals, were made in the antimesenteric border of the pelvic flexure of the ascending colon in five adult horses. Ten incisions each were sutured with a Utrecht pattern (single layer), a full-thickness simple continuous oversewn with a Cushing pattern (two layer), and a mucosal simple continuous with a seromuscular simple continuous oversewn with a Cushing pattern (three layer). In all horses, chromic gut and polyglactin 910 were each used once for each pattern. On day 6, the pelvic flexure was excised and the colonic vessels were injected with a r...
Turner AS, Yovich JV, White NA, Embertson RE, Santschi EM, Slone DE.A retrospective study was performed to evaluate the healing of ventral midline abdominal incisions, closed with a simple continuous suture pattern using absorbable suture material, in 139 horses and foals. Dehiscence and incisional hernia developed separately in two horses. The low incidence of dehiscence and incisional hernia, compared with their reported incidence following the use of interrupted suture repair, leads the authors to recommend this alternative method of abdominal incision closure in horses. The security of closure is not sacrificed and the advantages of a rapid closure are des...
Cox JE.A simple technique for castration of adult horses which results in first intention healing was devised. The technique involves a 'closed' castration with or without a transfixed ligature on the spermatic sac and suturing the scrotal skin with polyglycolic acid suture material. The postoperative course was characterised by mild oedema only and by rapid recovery. The results obtained during the course of removing 311 scrotal testes from horses and donkeys of all ages are described and discussed. The technique is readily applicable in the field.
Booth LC.Single or multiple split-thickness autogenous skin transplants were applied to 20 limb wounds of 17 horses. The surface area of the wounds ranged from 25 to 200 sq cm. Grafts 0.635-mm thick were collected by use of an electric dermatome and were expanded on a mesh dermatome. The expanded mesh grafts were applied to wounds on 3 horses 4 days after injury. For the other 14 horses, grafts were applied after a granulation tissue bed had formed. The grafts were secured to the recipient beds with sutures and a dressing composed of a foam pad and elastic adhesive tape or with the dressing alone. Furt...
Hanson RR, Nixon AJ, Calderwood-Mays M, Gronwall R, Pendergast JF.Two techniques for end-to-end anastomosis of the small colon were evaluated in each of 6 horses. A simple interrupted suture pattern that excluded the mucosa and was oversewn with an inverting suture was compared with a triangulated double-row pattern of stainless steel staples. Anastomotic sites were evaluated at 2 weeks, 2 months, and 6 months for extent of abdominal adhesions, lumen diameter at anastomotic sites, bursting pressures, and healing response. Clinical postoperative complications were not associated with either technique. At postmortem examination, there was extensive adhesion fo...
Santos MP, Gutierrez-Nibeyro SD, Horn GP, Johnson AJ, Stewart MC, Schaeffer DJ.To compare the mechanical properties of laryngeal tie-forward (LTF) surrogate constructs prepared with steel fixtures and No. 5 braided polyester or braided polyethylene by use of a standard or a modified suture placement technique. Methods: 32 LTF surrogate constructs. Methods: Surrogate constructs were prepared with steel fixtures and sutures (polyester or polyethylene) by use of a standard or modified suture placement technique. Constructs underwent single-load-to-failure testing. Maximal load at failure, elongation at failure, stiffness, and suture breakage sites were compared among constr...
Hale MJ, Zellner EM, Naiman JH, Kraus KH.To determine the influence of suture patterns on resistance to gap formation after tendon plating STUDY DESIGN: Ex vivo study SAMPLE POPULATION: Suspensory ligament and superficial and deep digital flexor tendons harvested from 16 neonatal cadaver foal limbs. Methods: Each tendon/ligament from a given limb was randomly assigned to one of three treatment groups consisting of a 7-hole veterinary cuttable plate fixed with alternating simple interrupted, figure-8, or hybrid suture patterns. The constructs were distracted at a rate of 1.0 mm/s to failure, as determined by the formation of a 1 m...
Markel MD, Dreyfuss DJ, Meagher DM.A study was designed to evaluate 2 colopexy techniques (A and B) in 8 clinically normal horses to determine which technique would prevent recurrence of large-colon displacement and/or volvulus. For technique A, 35 cm of the lateral free band of the left ventral colon was sutured to the abdominal wall, 6 cm to the left of ventral midline. For technique B, the medial free band of the left ventral colon was sutured to the medial free band of the right ventral colon, and 8 cm of the lateral free band of the left ventral colon was sutured to the abdominal wall, 6 cm to the left of ventral midline. ...
Kelly JR, Carmalt J, Hendrick S, Wilson DG, Shoemaker R.To compare biomechanical properties of 6 suture configurations using a large diameter polyester prosthesis in the muscular process (MP) of the arytenoid cartilage and to determine failure mode. Methods: Experimental study. Methods: Cadaveric equine larynges (n=121). Methods: Suture configurations (4 single, 2 double) were inserted, and then constructs were tested in a single-cycle to failure at a 100 mm/min distraction. Load deformation curves were generated to assess the biomechanical properties of each construct. A 1-way ANOVA was used to compare the mean differences in construct failure for...
Scherzer S, Hainisch EK.To report the use of a nylon suture system (Canine Cranial Cruciate Ligament Repair System; Securos Inc Veterinary Orthopedics) as a prosthesis for equine laryngoplasty. Methods: Experimental and prospective clinical study. Methods: Cadaver specimens (n = 5) and 7 horses with left laryngeal hemiplegia. Methods: A commercially available monofilament nylon suture system was implanted as a laryngeal prosthesis. Arytenoid cartilage abduction was achieved with a tensioning device applied to the suture prosthesis during transnasal endoscopic observation. Suture fixation was achieved with crimping cl...
Rossignol F, Ouachée E, Boening KJ.To describe a modified laryngeal tie-forward procedure (LTFP) using metallic implants. Methods: Retrospective case series. Methods: Twenty-seven horses (including 24 race horses) with dorsal displacement of the soft palate (DDSP) or palatal instability (PI) diagnosed using high-speed treadmill endoscopy (n = 15), history and resting examination (n = 8), or dynamic endoscopy over ground (n = 4). Methods: All horses underwent the modified LTFP. Modifications of the surgical procedure consisted in the use of 3 metallic stents called Suture Button(TM) through which the sutures are threaded and in ...
Nixon AJ, Stashak TS, Smith FW, Norrdin RW.Carbon fibre-polylactic acid composites and monofilament non-absorbable suture material were compared for the repair of surgically transected superficial digital flexor tendons in 10 horses. All surgical wounds healed by first intention. The repaired tendons were enlarged, the carbon implanted tendons being larger than those sutured. The horses were killed at six, eight, 12,20 or 24 weeks. Greater fibrous thickening occurred in tendons repaired with carbon fibre, especially at 12 weeks postoperatively. Carbon fibre incited a greater histological response with macrophages, lymphocytes, plasma c...
Dean PW, Robertson JT, Jacobs RM.In 7 horses, 4 anastomoses were done in the small intestine in each, using the combinations of synthetic absorbable monofilament and multifilament suture materials with continuous- and interrupted-suture patterns in the serosubmucosal layer of a 2-layer inverting-suture technique. Horses were evaluated 30 days after the operation for adhesion formation, lumen diameter, evidence of chronic obstruction, and suture tract inflammation at the anastomosis. Postoperative obstruction occurred in 5 of the 7 horses, and 6 horses survived. One horse was euthanatized on postoperative day 6 after 48 hours ...
Olivier A, Steenkamp G, Petrick SW, Gottschalk RD.Repair of parotid duct lacerations in 2 horses is described using intraluminal silastic tubing as a stent. The duct was lacerated traumatically at the facial vessel notch (incisura vasorum facialium) in the 1st horse, and iatrogenically after removal of an intraluminal sialolith after development of infection within the duct in the 2nd horse. In both cases, a silastic tube was passed retrograde into the duct via the salivary papilla, past the wound until the end lay rostroventral to the parotid salivary gland. The severed salivary ducts and the wounds were sutured. The external portion of the ...
Carpenter EM, Hendrickson DA, James S, Franke C, Frisbie D, Trostle S, Wilson D.To determine a hand-tied ligature knot configuration, suture size, and suture type that would be an acceptable substitute to commercially available ligature knots for use in equine laparoscopic surgery. Methods: Three-factor ANOVA with the fixed effects being suture type, suture size, and knot type. The dependent variable was ligature security (load to failure). Methods: Commercially available Endoloop and 4 hand-tied slipknot ligatures were compared with a 4-layer square knot. The hand tied ligature knots tested were the 4S modified Roeder knot, the Brooks knot, the modified Roeder knot, and ...
Peloso JG, Schumacher J, McClure SR, Crabill MR, Hanselka DV, Householder DD, Potter GD.A T-cannula was fitted permanently into the ileum of ten mature ponies to quantify the role of the prececal and postileal segments of the digestive tract in equine nutrition studies. The ponies were anesthetized, positioned in left lateral recumbency, and the distal small intestine was exteriorized through a right paralumbar incision. A silastic T-cannula was inserted through a 2-cm longitudinal incision into the lumen of the ileum, on the antimesenteric surface, and sutured to the ileum. The stem of the cannula was exteriorized through a 2-cm circular skin incision, 6 cm caudal to the 16th ri...
Easley KJ, Stashak TS, Smith FW, Van Slyke G.Thirty-six superficial digital flexor tendons from nine fresh equine cadavers were transected and sutured with size 2 monofilament nylon. Nine tendons were repaired with each of four suture patterns: single-locking loop, double-locking loop, triple-locking loop, or three-loop pulley. The times required for application, tensile strengths, resistance to distraction (gap), and modes of failure were analyzed. The mean times required were: single-locking loop, 3 mins, 15 secs; double-locking loop, 4 mins, 15 secs; triple-locking loop, 10 mins, 50 secs; and three-loop pulley, 4 mins. The double-lock...
Jenson PW, Lillich JD, Roush JK, Gaughan EM.To test the failure strength and energy of 2 bioabsorbable implants applied to transected deep digital flexor tendons (DDFT) from adult horses. Methods: Ex vivo biomechanical experiment. Methods: Twelve pairs of deep digital flexor tendons harvested from the forelimbs of fresh equine cadavers. Methods: Poly-L-lactic acid tendon plates were custom manufactured for application to the cylindrical surface of an adult equine deep digital flexor tendon. Twelve pairs of DDFTs were transected 2 cm distal to the insertion of the distal check ligament of the deep digital flexor tendon. One tendon of eac...
Giusto G, Caramello V, Comino F, Gandini M.In this study the caecum and large colon were harvested from 24 slaughtered horses. On each sample, an 8‑cm long enterotomy was performed. Enterotomies were closed using either barbed or unbarbed glycomer‑631. We compared the time to close, appearance, length of suture material, bursting pressure, and costs associated with each type of material. Our findings demonstrated that time to close was significantly shorter (caecum, P = 0.034; pelvic flexure, P = 0.039) using barbed sutures (caecum 610.4 seconds; pelvic flexure 699.3 seconds) than unbarbed sutures (caecum 661.0 seconds, pelvic flex...
Schaaf KL, Kannegieter NJ, Lovell DK.Ten horses presented with severe distortion of the facial contour, crepitus on palpation and mild to moderate epistaxis. Individual horses also showed ocular damage, ptosis, severe dyspnoea and movement of the facial bones concurrent with respiration. The fracture fragments were exposed using a large curvilinear incision and elevated using a retractor, periosteal elevator, chisel or Steinmann pin. The fracture fragments were unstable following reduction and fixation was necessary. Stabilisation was achieved with polydioxanone sutures placed through holes drilled in opposing sides of the fractu...
Anderson SL, Bracamonte JL, Hendrick S.The objective of this study was to compare the bursting strength (BS) and mode of failure (MF) of ventral midline (VM) celiotomies closed with USP 7 polydioxanone (7PD) in 1 or 2 simple continuous sections. A bursting strength model, consisting of inserting and inflating a 200-L polyurethane bladder through a 25-cm VM celiotomy, was used on 15 fresh equine cadavers. Celiotomies were closed using 7PD in 2 separate sections (4 knots), 2 continuous sections (3 knots), or a single section (2 knots) using a simple continuous pattern. The horses' signalment, body weight, number of total knots, MF, a...
Scharner D, Winter K, Brehm W, Kämpfert M, Gittel C.Despite advances in surgical technique in abdominal surgery, incisional complications are frequently reported following ventral midline laparotomy in horses. The aim of this study was to determine the incidence of incisional complications at our clinic and to identify possible risk factors. Furthermore, we investigated whether suturing the peritoneum leads to a reduction of incisional complications. Methods: In this retrospective study, records of patients of the Large Animal Clinic for Surgery of the University of Leipzig from January 2010 to December 2015 were analysed. Horses with ventral m...
Everett E, Barrett JG, Morelli J, DeVita R.To compare in vitro biomechanical properties of a novel suture pattern to a current standard for primary repair of equine superficial digital flexor tendon (SDFT) laceration. Methods: In vitro randomized, paired design. Methods: Cadaveric equine forelimb SDFT (n = 24). Methods: The 3-loop pulley (3LP) and 6-strand Savage (SSS) suture patterns were applied to transected equine SDFT. Ultimate failure load, stiffness, mode of failure, and load required to form a 3-mm gap were obtained using a materials testing system and synchronized high-speed video analysis. Statistical comparisons were made us...
Rossignol F, Perrin R, Desbrosse F, Elie C.To compare in vitro the load necessary for a partial and complete rupture of the muscular process arytenoid cartilage when a suture prosthesis is positioned by a bone trocar versus a trocar point needle and to compare failure mode. Methods: Experimental using cadaver specimens. Methods: Larynges from 18 Thoroughbred race horses, aged 2-20 years. Methods: Arytenoid cartilages were separated randomly into 2 groups: group 1-suture prosthesis inserted directly through the muscular process using a curved trocar point needle and group 2-suture passed through a hole predrilled with a 3 mm bone trocar...
Aristizabal FA, Lopes MA, Silva A, Avanza MF, Nieto JE.To evaluate the effect of onlay mesenteric flaps (MFs) with end-to-end jejunojejunostomy on stomal diameter, length of jejunum with reduced stomal diameter, abdominal adhesion formation, and healing. Methods: Experimental study. Methods: Healthy adult horses (n = 6). Methods: Two hand sewn end-to-end jejunal anastomoses using a 1 layer simple continuous serosubmucosal suture pattern were performed in each horse ∼ 2 and 5 m oral to the ileocecal fold. Using a random design for selection anastomosis location (oral or aboral), 1 anastomosis was covered with 2 adjacent onlay MFs secured with int...
Pascoletti G, Pressanto MC, Putame G, Terzini M, Audenino AL, Zanetti EM.A number of surgical practices are aimed to compensate for tissue relaxation or weakened/atrophied muscles by means of suture prostheses/thread lifts. The success rate of these procedures is often very good in the short term, while it is quite variable among subjects and techniques in the middle-long term. Middle-long term failures are mostly related to suture distraction, loosening or wear, coming from repeated loading cycles. In this work, an experimental device to perform ex vivo tests on prosthetic sutures has been set up. An equine laryngoplasty has been used as a benchmark, being represe...
Vázquez FJ, Argüelles D, Muñoz JA, Genton M, Méndez Angulo JL, Climent F, Roquet I, Iglesias M, Velloso Álvarez A, Vitoria A, Bulnes F, Saitua A....Inguinal hernias (IHs) and ruptures are a relatively common condition in horses, occurring in foals (congenital) and adult (acquired) animals. A retrospective observational analysis was conducted on 40 cases that underwent laparoscopic surgery to close the VRs using barbed sutures alone or combined with other techniques. Signalment, clinical presentation, surgery, and follow-up data were obtained. In total, fifty-nine VRs were closed using barbed sutures (alone or in combination with other methods), with six cases performed prophylactically and forty-four due to acquired IH. Of the forty-four ...
Klein CE, Engiles JB, Roessner HA, Hopster K, Hurcombe SD.To compare the application and healing of the zip skin closure system (ZSCS) with sutured closure by use of a split-scar model of ventral midline incisions in horses in a prospective, randomized experimental study. Methods: 8 adult horses. Methods: All horses underwent an exploratory ventral midline celiotomy with a standardized 30-cm skin incision. Each horse was randomized to have either the cranial 15 cm closed with suture and caudal 15 cm with the ZSCS or vice versa (split-scar model). Skin closure time was recorded and compared. Photography and skin biopsies were taken preoperatively and ...
Rodgerson DH, Spirito MA.Instability of the collateral ligaments of the carpal or metacarpophalangeal joint occurred in 2 foals. The instability was repaired using commercial suture anchors. In foals, commercial suture anchors combined with external coaptation can be used successfully to repair collateral ligament instability of the carpus or the metacarpophalangeal joint.