Analyze Diet

Topic:Suture

Sutures are medical devices used to close wounds or surgical incisions in horses. They are typically made from materials such as nylon, polypropylene, or absorbable polymers and are selected based on the specific requirements of the wound or procedure. Sutures serve to approximate tissue edges, promote healing, and reduce the risk of infection. In equine medicine, the choice of suture material, technique, and pattern can significantly affect the healing process and the outcome of surgical interventions. This page compiles peer-reviewed research studies and scholarly articles that examine the types, applications, and outcomes of suture use in equine veterinary practice.
Biomechanical testing of three constructs for prosthetic laryngoplasty in horses demonstrates advantages of differing metallic implants in the arytenoid cartilage.
Veterinary surgery : VS    August 10, 2025   doi: 10.1111/vsu.14328
Ysebaert MP, Johnson J, Marie U, Campos A, Verchrerin A, Ducharme NG, Rossignol F, Luedke LK.To compare the biomechanical stability of a novel arytenoid implant (tie-bolt, TB) with a suture anchor (SA) and standard laryngoplasty using suture alone (control) in equine larynges. Methods: Randomized ex vivo controlled experimental study. Methods: Thirty equine cadaver larynges. Methods: Larynges were randomly assigned to TB, SA, or control groups (n = 10 each). The force of abduction was measured for each construct, then constructs underwent cyclic loading (5-50 N for 3000 cycles) to assess elongation, followed by load-to-failure testing to assess ultimate load, displacement, stiffn...
Complications associated with subpalpebral lavage systems in upper and lower equine eyelids: A prospective, randomised study in 73 cases (2015-2024).
Equine veterinary journal    June 26, 2025   doi: 10.1111/evj.14540
Graham AE, Carslake HB, Malalana F.Evidence for optimal location of subpalpebral lavage (SPL) systems is lacking. Objective: To compare the rate and types of complications with SPL systems located in central upper- compared with medial lower-eyelid in hospitalised patients. Methods: Prospective, randomised treatment trial. Methods: Horses admitted for ophthalmic treatment using an SPL system from February 2015 to January 2024 were included if ocular pathology did not necessitate SPL system placement in a specific location. Coin toss was used to determine location. SPL systems were monitored at least daily, and complications wer...
An ex vivo comparison of jejunal transection angles and the effect on lumen diameter following end-to-end jejunojejunal anastomoses.
Veterinary surgery : VS    June 17, 2025   doi: 10.1111/vsu.14294
Baldwin CM, Gillen A.To evaluate three different jejunal transection angles for end-to-end jejunojejunostomies, comparing construction time, lumen size, and suture number. Methods: Ex vivo cadaver study. Methods: Eight euthanized horses each had three mid-jejunal specimens harvested. Methods: Jejunal segments were assigned to one of three groups (A30, A45, and A60) and transected at 30, 45, or 60°, respectively. Following transection, a standardized handsewn single-layer interrupted modified Lembert anastomosis was performed, and construction time and number of sutures placed were recorded. Anastomotic index (AI)...
A novel placement method of a calibration-free pH capsule for continuous wireless measurement of intragastric pH in horses.
Journal of veterinary internal medicine    December 23, 2024   Volume 39, Issue 1 e17273 doi: 10.1111/jvim.17273
Hodgson E, Thirouin M, Narayanan P, Romano TR, Wise J, Bond S.Current methods to measure intragastric pH in horses have limitations. A wireless capsule has been designed for continuous esophageal pH monitoring in humans. Objective: To (1) determine the feasibility and describe the methodology of measuring intragastric pH wirelessly in horses; and (2) determine attachment duration of the capsules. Methods: Eleven healthy adult horses. Methods: Capsules were attached to squamous and glandular gastric mucosa under gastroscopic guidance, using suture loops and 1 to 4 hemostasis clips. pH was continuously recorded using a wireless recorder in both fed and fas...
Ex vivo comparison of one-layer versus two-layer closures in end-to-end anastomoses in normal equine descending colon.
Veterinary surgery : VS    September 5, 2024   doi: 10.1111/vsu.14150
St Blanc MP, Mirza MH, Riggs LM, Leise BS.The aim of the study was to evaluate time to closure, bursting pressures and luminal diameters of a single and double-layer end-to-end anastomoses in normal equine descending colon. Methods: Experimental study. Methods: Eight adult horses. Methods: Four segments of descending colon from each horse were randomly assigned to a control (n = 8, CON), one-layer (n = 12, group 1; continuous Lembert pattern), or two-layer group (n = 12, group 2; simple continuous oversewn with Cushing pattern). Anastomoses were performed, and time to closure and luminal diameter were measured. Bursting pr...
Use of Knotless Barbed Sutures in Laparoscopic Inguinal Hernioplasty in Horses: 40 Cases.
Animals : an open access journal from MDPI    June 19, 2024   Volume 14, Issue 12 doi: 10.3390/ani14121826
Vázquez FJ, Argüelles D, Muñoz JA, Genton M, Méndez Angulo JL, Climent F, Roquet I, Iglesias M, Velloso Álvarez A, Vitoria A, Bulnes F, Saitua A....Inguinal hernias (IHs) and ruptures are a relatively common condition in horses, occurring in foals (congenital) and adult (acquired) animals. A retrospective observational analysis was conducted on 40 cases that underwent laparoscopic surgery to close the VRs using barbed sutures alone or combined with other techniques. Signalment, clinical presentation, surgery, and follow-up data were obtained. In total, fifty-nine VRs were closed using barbed sutures (alone or in combination with other methods), with six cases performed prophylactically and forty-four due to acquired IH. Of the forty-four ...
Surgical Closure of Equine Abdomen, Prevention, and Management of Incisional Complications.
Journal of visualized experiments : JoVE    May 10, 2024   Issue 207 doi: 10.3791/65546
Salciccia A, de la Rebière de Pouyade G, Caudron I, Ponthier J, Serteyn D, Sandersen C, Deleuze S, Grulke S.Although rarely fatal, complications of ventral midline laparotomy incision in equine patients increase hospitalization cost and duration and may jeopardize return to athletic function. Therefore, many techniques have been developed to reduce their occurrence and expedite their resolution when they occur. Our technique of celiotomy incision closure includes the use of tension sutures (vertical U mattress) of polyglactin 910 on the linea alba, which is then apposed by polyglactin 910 interrupted sutures or a simple continuous pattern suture with a stop midway before routine closure of the super...
Horse owner perceptions of equine veterinary nursing roles in the United Kingdom.
The Veterinary record    April 24, 2024   e4148 doi: 10.1002/vetr.4148
Pritchard P, Robinson N, Saul A, Shrubb J, Stavisky J, Dean R.Registered (equine) veterinary nurses (R(E)VNs) typically provide few client-facing services. Better utilising R(E)VN skills could help address workforce shortages, improve morale and benefit patient health. The aim of this study was to explore horse owner perceptions of R(E)VN roles. Methods: An online cross-sectional survey of horse owners gathered data on their understanding of R(E)VN roles, their experiences of R(E)VNs their openness to further R(E)VN services and perceived facilitators of and barriers to such services. Participants were recruited via practices, social media and snowball s...
Ultrasonographic findings of fluid accumulation and hyperechogenic spots suggestive of surgical site infection following laparotomy for colic in horses.
The Veterinary record    April 5, 2024   Volume 194, Issue 10 e4045 doi: 10.1002/vetr.4045
Pilati N, Pressanto MC, Beccati F, Pepe M, Venditti R, Gialletti R.The aim of this study was to compare ultrasonographic findings of the ventral midline incision after exploratory laparotomy for colic in horses with and without surgical site infection (SSI). Ultrasonographic examination of the surgical wound was performed on postoperative day 5 (D5) and day 10 (D10) to assess the presence of fluid accumulation, suture sinus formation, hyperechogenic spots and fistulous path. Clinical evaluation of the wound was used to classify horses with and without SSI. The accuracy, sensitivity, specificity and positive and negative predictive values of the ultrasonograph...
Pattern of prescriptions and prudent use of antimicrobial in horse practice at a Veterinary Teaching Hospital.
Research in veterinary science    January 4, 2024   Volume 168 105140 doi: 10.1016/j.rvsc.2024.105140
Bacci S, Meucci V, Sgorbini M, De Marchi L, Pirone A, Pretti C, Tognetti R, Intorre L.Antimicrobial prescriptions of the University of Pisa and their compliance with prudent use recommendations were investigated over 11 years (2011-2021). At least one antimicrobial was always prescribed in surgical prophylaxis for the suture of wounds and in 33% of horses with signs of disease of a body system. Antimicrobials were administered in monotherapy (48%) in fixed dose combinations (21%) and empirical combinations (31%). Antimicrobials were mostly (63%) administered by parenteral route, while oral and topical antimicrobials accounted for 14% and 23% of prescriptions, respectively. Gen...
Ex vivo study shows novel, rapid, suture-free tenotomy technique for the equine deep digital flexor tendon.
American journal of veterinary research    December 22, 2023   1-6 doi: 10.2460/ajvr.23.09.0215
De Gasperi D, El Azzi MS, Martins JPN, Brounts SH.To describe the feasibility of a novel thread-transecting technique for the tenotomy of the equine deep digital flexor tendon (DDFT). Methods: 39 equine distal limb specimens. Methods: Under ultrasonographic guidance, a surgical thread was percutaneously placed around the DDFT through 2 needle punctures (lateral and medial) using a Tuohy needle in equine limbs (22 forelimbs, 17 hindlimbs). The DDFT was transected by a back-and-forth motion of the thread until the loop emerged from the entry puncture site. Each specimen was dissected and assessed for completeness of transection and iatrogenic d...
Ex-vivo evaluation of a percutaneous looped thread desmotomy of the accessory ligament of the deep digital flexor tendon in horses.
Veterinary surgery : VS    December 22, 2023   doi: 10.1111/vsu.14065
Orozco Lopez D, Mochal-King C, Fontenot R, O'Shea CM.To determine the ability to completely transect the equine accessory ligament of the deep digital flexor tendon (AL-DDFT) via an ultrasonographically-guided, percutaneous looped thread desmotomy using FiberWire suture as a cutting device. Methods: Ex-vivo study. Methods: A total of 24 normal equine distal forelimb specimens. Methods: Under ultrasonographic guidance, a Jamshidi needle was placed between the suspensory ligament and the AL-DDFT, and between the AL-DDFT and the deep digital flexor tendon, through two stab incisions. FiberWire suture was fed through the needle and looped around the...
Rectal tear repair using barbed suture in the horse.
Journal of the American Veterinary Medical Association    September 27, 2023   1-5 doi: 10.2460/javma.23.04.0215
Kamm JL.To describe the repair utilizing integral-anchor barbed suture in equine rectal tears. Methods: 3 horses aged 3 to 10 years old with grade 3 to 4 rectal tears. Methods: Grade 3 and 4 rectal tears were referred for surgical repair immediately after iatrogenic tearing or tearing during parturition. Integral-anchor barbed suture (Stratafix Symmetric PDS Plus, size 1, 18" CT-1) was placed using long-handled instruments or hand closure depending on the accessibility and visibility of the tear. Closure of grade 3 tears was performed using a continuous appositional pattern. A horizontal mattress patt...
Comparison of incisional bursting strength of a bidirectional absorbable knotless suture material versus a standard continuous absorbable suture material for closure of the equine linea alba.
Veterinary surgery : VS    September 1, 2023   Volume 52, Issue 8 1121-1127 doi: 10.1111/vsu.14022
Bellitto NA, Oliver FB, Pollock PJ.To evaluate the use of bidirectional knotless barbed suture material for closure of the equine linea alba. Methods: Laboratory study. Methods: Adult light horse cadavers (n = 24). Methods: A 25 cm incision was made through the linea alba, and a 200 L polyurethane bladder was positioned within the abdomen. The linea alba was closed either using USP2/EP5 bidirectional polydioxanone barbed suture or USP2/EP5 standard polydioxanone suture in a simple continuous pattern. Closure time was recorded for each suture type. The bladder was air-insufflated at 40 L/min, and the pressure at body w...
A novel tension relief technique to aid the primary closure of traumatic equine wounds under excessive tension.
Equine veterinary journal    August 9, 2023   Volume 56, Issue 3 514-521 doi: 10.1111/evj.13987
Comino F, Pollock PJ, Fulton I, Hewitt-Dedman C, Handel I, Gorvy DA.To achieve an excellent functional and cosmetic result, primary closure is preferred over leaving wounds to heal by secondary intention. However, traumatic wounds are often under excessive tension during wound closure and incorrect suture technique can compromise microcirculation, leading to skin necrosis and impaired wound healing. Objective: To describe an inexpensive and effective tension relief technique that helps the successful primary closure of a variety of equine wounds at high risk of dehiscence. Methods: Retrospective case series. Methods: All wounds that were managed with the Tensi...
The effect of medical grade honey on tensile strength, strain, and Young’s modulus of synthetic absorbable suture material used in equine surgery.
Equine veterinary journal    June 16, 2023   doi: 10.1111/evj.13966
Madsen K, Martens A, Haspeslagh M, Meulyzer M, Gustafsson K.Medical grade honey (MGH) has been introduced as a protective measure against surgical site infections in equine surgery, but the effect on suture material has not been investigated. Objective: To evaluate the effect of MGH on the tensile properties of three synthetic absorbable suture materials. Methods: In vitro experiments. Methods: Ten strands of Polydioxanone USP 2 (PD2), Polyglactin 910 USP 2 (PG2) and Polyglecaprone USP 2-0 (PC2-0) were incubated 1, 7, 14, 21 and 28 days in MGH, phosphate-buffered saline (PBS), equine plasma (EP) and MGH mixed with equine plasma (HP). Mechanical testi...
A biomechanical comparison of a novel two-loop suture technique and two sutures for laryngoplasty in the horse.
American journal of veterinary research    March 7, 2023   Volume 84, Issue 5 ajvr.22.11.0189 doi: 10.2460/ajvr.22.11.0189
Wilson DG, Roquet I, Tucker ML, Carmalt JL.Evaluation of the strength of the novel suture technique by comparison with a 2-interrupted suture technique. Methods: 40 equine larynges. Methods: 40 larynges were used; 16 laryngoplasties were performed using the currently accepted 2-suture technique and 16 using the novel suture technique. These specimens were subjected to a single cycle to failure. Eight specimens were used to compare the rima glottidis area achieved with 2 different techniques. Results: The mean force to failure, as well as the rima glottidis area of both constructs, were not significantly different. The cricoid width did...
The effect of cyanoacrylate on knot elongation in three sutures used for prosthetic laryngoplasty in the horse.
Veterinary surgery : VS    January 24, 2023   Volume 52, Issue 3 428-434 doi: 10.1111/vsu.13936
Watkins AR, Ford M, van Eps AW, Stefanovski D, Parente EJ.This study investigated the elongation following cyclic loading on square knots of 5 USP multifilament long-chain ultra-high molecular weight polyethylene core (UHMWPE), 2 mm woven UHMWPE tape, and 5 USP braided polyester, with and without cyanoacrylate glue. Methods: Experimental study. Methods: n = 4. Methods: Three conditions (suture without knot, suture with knot, suture with knot + cyanoacrylate) were evaluated for each suture material on a mechanical test stand by measuring the increased length of the construct after cycling from 25 to 50N for 1000 repetitions at 20 mm/second. Knot...
The effect of repeated freezing and thawing on the suture pull-out strength in equine arytenoid and cricoid cartilages.
Veterinary surgery : VS    July 11, 2022   Volume 51, Issue 7 1106-1110 doi: 10.1111/vsu.13855
Gray SM, Gutierrez-Nibeyro SD, Horn GP, McCoy AM, Schaeffer DJ, Stewart M.To assess the effect of repeated freezing and thawing on the suture pull-out strength in arytenoid and cricoid cartilages subjected to the laryngoplasty (LP) procedure. Methods: Ex vivo experimental study. Methods: Ten grossly normal equine cadaveric larynges. Methods: Bilateral LP constructs were created using a standard LP technique. One hemilarynx was randomly allocated to the single freeze and thaw group and the other allocated to the repeated freeze and thaw (3 complete cycles) group. The suture ends of each LP construct were attached to a load frame and subjected to monotonic loading unt...
Ex vivo biomechanical evaluation of polyester and polyblend suture techniques to perform equine laryngoplasty.
Veterinary surgery : VS    February 7, 2022   Volume 51, Issue 3 497-508 doi: 10.1111/vsu.13777
Pressanto MC, Pascoletti G, Perkins JD, Zanetti EM, Beccati F, Santalucia V, Pepe M.To validate the use of a polyblend tape suture in equine laryngoplasty (PL). Methods: Experimental study. Methods: Thirty-two cadaveric larynges. Methods: Each larynx was randomly assigned to 1 of 4 groups: PL with polyblend tape suture (TigerTape), without (TT) or with a cannula (TTC) in the muscular process of the arytenoid cartilage, and PL with polyester suture (Ethibond), without (EB) or with a cannula (EBC). Construct stiffness, total migration, creep, and drift values were measured after 3000 cycles. The specimens were then loaded to failure to assess their residual properties: load a...
Comparison of the zip skin closure system with conventional suture for skin closure of ventral midline incisions in horses.
American journal of veterinary research    February 2, 2022   Volume 83, Issue 5 455-464 doi: 10.2460/ajvr.21.08.0135
Klein CE, Engiles JB, Roessner HA, Hopster K, Hurcombe SD.To compare the application and healing of the zip skin closure system (ZSCS) with sutured closure by use of a split-scar model of ventral midline incisions in horses in a prospective, randomized experimental study. Methods: 8 adult horses. Methods: All horses underwent an exploratory ventral midline celiotomy with a standardized 30-cm skin incision. Each horse was randomized to have either the cranial 15 cm closed with suture and caudal 15 cm with the ZSCS or vice versa (split-scar model). Skin closure time was recorded and compared. Photography and skin biopsies were taken preoperatively and ...
Comparing two surgical techniques for repairing third-degree perineal lacerations in postpartum broodmares.
The Veterinary record    September 11, 2021   Volume 189, Issue 5 e907 doi: 10.1002/vetr.907
Sheard L.No abstract available
Use of Polyamide (Nylon) Cable Ties for Vascular Ligation of Healthy Equine Jejunal Mesentery.
Frontiers in veterinary science    August 12, 2021   Volume 8 639424 doi: 10.3389/fvets.2021.639424
Hurcombe SD, Roessner HA, Klein CE, Engiles JB, Hopster K.Jejunal vascular ligation is an essential step in performing jejunojejunostomy. Hand sewn ligation is typically used and can increase operative time with long sections of bowel to be removed. Nylon cable ties (NCT) have been used for vascular ligation in horses but are yet to be investigated for application on the mesenteric vasculature of the gastrointestinal tract. Our objective was to evaluate the efficacy and short-term safety of NCT jejunal mesenteric vessel ligation in healthy horses. Eight healthy adult horses underwent midline celiotomy. A segment of jejunal mesentery was identified (...
Ex vivo mechanical testing of various suture patterns for use in tendon plating.
Veterinary surgery : VS    June 2, 2021   Volume 50, Issue 6 1296-1303 doi: 10.1111/vsu.13659
Hale MJ, Zellner EM, Naiman JH, Kraus KH.To determine the influence of suture patterns on resistance to gap formation after tendon plating STUDY DESIGN: Ex vivo study SAMPLE POPULATION: Suspensory ligament and superficial and deep digital flexor tendons harvested from 16 neonatal cadaver foal limbs. Methods: Each tendon/ligament from a given limb was randomly assigned to one of three treatment groups consisting of a 7-hole veterinary cuttable plate fixed with alternating simple interrupted, figure-8, or hybrid suture patterns. The constructs were distracted at a rate of 1.0 mm/s to failure, as determined by the formation of a 1 m...
An ex vivo biomechanical comparison of two suture materials and two pattern combinations for equine superficial digital flexor tendon tenorrhaphy.
Veterinary surgery : VS    May 13, 2021   Volume 50, Issue 5 1137-1146 doi: 10.1111/vsu.13658
Giacchi A, McMaster MA.To compare biomechanical characteristics of three-loop pulley (3LP) pattern versus Bunnell technique (BT) using polydioxanone (PDS) suture; to determine the influence of polyester tape (PT) versus PDS on the BT for equine superficial digital flexor tendon (SDFT) tenorrhaphy; to compare BT with PT versus 3LP with PDS. Methods: Ex vivo biomechanical study. Methods: Forty equine forelimb SDFT. Methods: Two experiments were performed: (1) 10 SDFT pairs were repaired with 3LP or BT using PDS; (2) 10 SDFT pairs were repaired with PDS or PT using BT. Load at failure, mode of failure, load at 2 mm g...
Effect of three different needle holders on gastrointestinal anastomosis construction time and bursting pressure in equine jejunal segments.
BMC veterinary research    April 15, 2021   Volume 17, Issue 1 167 doi: 10.1186/s12917-021-02871-4
Averay K, van Galen G, Ward M, Verwilghen D.Equine small intestinal resection and anastomosis is a procedure where optimizing speed, without compromising integrity, is advantageous. There are a range of different needle holders available, but little is published on the impact surgical instrumentation has on surgical technique in veterinary medicine. The objectives of this study were to investigate if the needle holder type influences the anastomosis construction time, the anastomosis bursting pressure and whether the bursting pressure is influenced by the anastomosis construction time. Single layer end-to-end jejunojejunal anastomoses w...
Comparison of Mesh and Barbed Suture for Laparoscopic Nephrosplenic Space Ablation in Horses.
Animals : an open access journal from MDPI    April 12, 2021   Volume 11, Issue 4 doi: 10.3390/ani11041096
Gialletti R, Nannarone S, Gandini M, Cerullo A, Bertoletti A, Scilimati N, Giusto G.Nephrosplenic space (NSS) ablation has been demonstrated to be an effective technique for prevention of left dorsal displacement of the large colon and multiple laparoscopic techniques, among which ablation with mesh or with a barbed suture, have been proposed. Our objective was to compare two laparoscopic techniques for closure of the NSS in twenty-eight horses diagnosed with nephrosplenic entrapment. Medical records of horses that had laparoscopic NSS ablation in two referral centers between 2017-2019 were retrieved. Duration of surgery, complications, and short- and long-term follow-up info...
Barbed sutures do not increase wound complications in horses.
The Veterinary record    February 28, 2021   Volume 187, Issue 2 72 doi: 10.1136/vr.m2967
No abstract available
Treatment of Progressive Scleromalacia Perforans by Tectonic Enhancement With Lyophilized Equine Pericardium.
Cornea    September 15, 2020   Volume 40, Issue 5 648-651 doi: 10.1097/ICO.0000000000002465
Droutsas K, Giachos I, Katsiampoula V, Kourti P, Kymionis G, Petrou P.To describe the off-label use of lyophilized equine pericardium for tectonic enhancement of the sclera in a case of progressive scleromalacia perforans. Methods: An 82-year-old woman with a history of varicella zoster virus sclerokeratitis presented with a progressively expanding scleral thinning at the superonasal quadrant of the anterior sclera of her left eye. The eye was blind because of intractable glaucoma. To avoid perforation of the exposed choroid, a single layer of lyophilized equine pericardium was sutured over the scleral perforation. After performing a conjunctival peritomy in the...
Complications associated with closure of the linea alba using a combination of interrupted vertical mattress and simple interrupted sutures in equine laparotomies.
The Veterinary record    August 29, 2020   Volume 187, Issue 11 e94 doi: 10.1136/vr.105855
Salciccia A, de la Rebière de Pouyade G, Gougnard A, Detilleux J, Caudron I, Verwilghen D, Serteyn D, Grulke S.(1) Evaluate the occurrence and variables associated with incisional morbidities (IMs) after ventral median laparotomy when using interrupted vertical mattress sutures (IVMS) and (2) determine the occurrence of abdominal bandage-associated complications in horses. Methods: Occurrence of IM and bandage-associated complications were determined after single laparotomies (SL group; n=546 horses) and repeat laparotomies (RL group: multiple laparotomies within four weeks; n=30 horses) in horses that survived ≥7 days postoperatively. Univariate analysis and multivariate logistic regression were per...
1 2 3 7