Analyze Diet

Topic:Biomechanics

Biomechanics in horses refers to the study of the mechanical principles that govern movement and physical function in equine species. This field encompasses the analysis of gait, locomotion, and the forces exerted by and upon the horse's musculoskeletal system. Biomechanical studies often involve the use of motion capture technology, force plates, and computer modeling to assess how horses move and how various factors, such as conformation, training, and health status, influence their performance and soundness. Research in equine biomechanics contributes to understanding injury prevention, rehabilitation, and performance optimization. This page compiles peer-reviewed research studies and scholarly articles that explore the mechanics of movement, the impact of external and internal forces, and the applications of biomechanical analysis in equine care and management.
The analysis of densitometric and geometric parameters of bilateral proximal phalanges in horses with the use of peripheral quantitative computed tompgraphy.
Acta veterinaria Scandinavica    July 13, 2012   Volume 54, Issue 1 41 doi: 10.1186/1751-0147-54-41
Dzierzęcka M, Charuta A.Proximal phalanges in horses are among bones that are most prone to injuries. So far, the detailed analysis of densitometric and geometric parameters of both front legs proximal phalanges in horses has not been investigated. The aim of this study was to compare the densitometric and geometric parameters between proximal phalanges in equine both front legs with the use of peripheral quantitative computed tomography (pQCT). Methods: The study material comprised isolated both front legs proximal phalanges derived from 22 horses. The structure analysis of the proximal phalanges was conducted with ...
Periodontal biomechanics: finite element simulations of closing stroke and power stroke in equine cheek teeth.
BMC veterinary research    July 11, 2012   Volume 8 60 doi: 10.1186/1746-6148-8-60
Cordes V, Lüpke M, Gardemin M, Seifert H, Staszyk C.In equine dentistry periodontal diseases, especially periapical inflammation, are frequently occurring problems. Anachoresis is believed to be the most common cause for the development of such disorders. Nevertheless, there is still no substantiated explanation why settlement of pathogen microorganisms occurs in equine periodontal tissues. It is expected that excessive strains and stresses occurring in the periodontal ligament (PDL) during the horse's chewing cycle might be a predisposing factor. In this study this assumption was examined by finite element (FE) analyses on virtual 3-D models o...
Method for estimating maximum permissible load weight for Japanese native horses using accelerometer-based gait analysis.
Animal science journal = Nihon chikusan Gakkaiho    July 9, 2012   Volume 84, Issue 1 75-81 doi: 10.1111/j.1740-0929.2012.01041.x
Matsuura A, Irimajiri M, Matsuzaki K, Hiraguri Y, Nakanowatari T, Yamazaki A, Hodate K.The aim of this study was to establish a method for estimating loading capacity for Japanese native horses by gait analysis using an accelerometer. Six mares of Japanese native horses were used. The acceleration of each horse was recorded during walking and trotting along a straight course at a sampling frequency of 200 Hz. Each horse performed 12 tests: one test with a loaded weight of 80 kg (First 80 kg) followed by 10 tests with random loaded weights between 85 kg and 130 kg and a final test with a loaded weight of 80 kg again. The time series of acceleration was subjected to fa...
Comparative study of depth-dependent characteristics of equine and human osteochondral tissue from the medial and lateral femoral condyles.
Osteoarthritis and cartilage    July 7, 2012   Volume 20, Issue 10 1147-1151 doi: 10.1016/j.joca.2012.06.005
Malda J, Benders KE, Klein TJ, de Grauw JC, Kik MJ, Hutmacher DW, Saris DB, van Weeren PR, Dhert WJ.Articular cartilage defects are common after joint injuries. When left untreated, the biomechanical protective function of cartilage is gradually lost, making the joint more susceptible to further damage, causing progressive loss of joint function and eventually osteoarthritis (OA). In the process of translating promising tissue-engineering cartilage repair approaches from bench to bedside, pre-clinical animal models including mice, rabbits, goats, and horses, are widely used. The equine species is becoming an increasingly popular model for the in vivo evaluation of regenerative orthopaedic ap...
Correlations of unfavorable movement characteristics in warmblood foals and mares with routinely assessed conformation and performance traits.
Animal : an international journal of animal bioscience    July 6, 2012   Volume 7, Issue 1 11-21 doi: 10.1017/S1751731112001322
Becker AC, Stock KF, Distl O.New movement traits reflecting unfavorable movement characteristics were defined on the basis of detailed movement evaluations (DME) of warmblood foals and mares performed in connection with regular breeding events of the Oldenburg horse breeding societies in 2009 and 2010. DME information was available for 3374 foals and 2844 mares and used for correlation analyses with conformation information on 1987 mares from studbook inspections (SBI) in 2009 and performance information on 2758 mares from mare performance tests (MPT) in 2000 to 2008. Analyses of variance revealed few significant differen...
Specialization of tendon mechanical properties results from interfascicular differences.
Journal of the Royal Society, Interface    July 4, 2012   Volume 9, Issue 76 3108-3117 doi: 10.1098/rsif.2012.0362
Thorpe CT, Udeze CP, Birch HL, Clegg PD, Screen HR.Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles ...
The fractal structure of equine articular cartilage.
Scanning    June 29, 2012   Volume 34, Issue 6 418-426 doi: 10.1002/sca.21026
Smyth PA, Rifkin RE, Jackson RL, Reid Hanson R.The naturally occurring structure of articular cartilage has proven to be an effective means for the facilitation of motion and load support in equine and other animal joints. Cartilage has been found to be a complex and dynamic medium, which has led to an incomplete understanding of the nature and operating mechanisms acting within a joint. Although cartilage has biphasic and triphasic properties, it is believed that the performance of equine articular joints is influenced by the surface roughness of the joint cartilage (Ateshian et al., '98; Chan et al., 2011; Yao and Unsworth, '93). Various...
Hippotherapy effects on trunk, pelvic, and hip motion during ambulation in children with neurological impairments.
Pediatric physical therapy : the official publication of the Section on Pediatrics of the American Physical Therapy Association    June 28, 2012   Volume 24, Issue 3 242-250 doi: 10.1097/PEP.0b013e31825c1dc3
Encheff JL, Armstrong C, Masterson M, Fox C, Gribble P.This study investigated the effects of a 10-week hippotherapy program on trunk, pelvis, and hip joint positioning during the stance phase of gait. Methods: Eleven children (6 boys and 5 girls; 7.9 ± 2.7 years) with neurological disorders and impaired ambulation participated. Joint range of motion data were collected via 3-dimensional computerized gait analysis before and after the program. Paired t tests were performed on kinematic data for each joint. Results: Significant improvements (P ≤ .008) and large effect sizes (ESs) for sagittal plane hip positions at initial contact and toe-off we...
Effect of sequential removal of parts of the second metacarpal bone on the biomechanical stability of the equine carpus.
Veterinary surgery : VS    June 25, 2012   Volume 41, Issue 7 862-868 doi: 10.1111/j.1532-950X.2012.01011.x
Seabaugh KA, Hubert JD, Kawcak CE, McGilvray KC, Santoni BG, Rao S, Baxter GM.To quantify changes in biomechanical stability and stiffness within the equine carpus after removal of 50%, 80%, and 100% of the second metacarpal bone (MC2). Methods: In vitro biomechanical study. Methods: Cadaveric equine forelimbs (n = 16) were evaluated. Intact constructs were loaded in axial compression from 0 to 5000 N and compression + torsion (5000 N ± 20°) for 5 cycles. This was repeated after removal of 50%, 80%, and 100% of MC2. The primary biomechanical outcome variables were the compressive stiffness and compressive + torsional stiffness of the carpus. Relative kinematic motion ...
In vitro biomechanical evaluation and comparison of a new prototype locking plate and a limited-contact self compression plate for equine fracture repair.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    June 13, 2012   Volume 25, Issue 4 273-280 doi: 10.3415/VCOT-11-01-0011
Quinteros DD, García-López JM, Abuja GA, Tarkanian M, Maranda LS, Bubeck K, Kowaleski MP.To determine if the mechanical properties (strength and stiffness) of a new prototype 4.5 mm broad locking plate (NP-LP) are comparable with those of a traditional 4.5 mm broad limited-contact self compression plate (LC-SCP), and to compare the bending and torsional properties of the NP-LP and LC-SCP when used in osteotomized equine third metacarpal bones (MC3). Methods: The plates alone were tested in four-point bending single cycle to failure. The MC3-plate constructs were created with mid-diaphyseal osteotomies with a 1 cm gap. Constructs were tested in four-point bending single cycle to fa...
Accuracy and precision of equine gait event detection during walking with limb and trunk mounted inertial sensors.
Sensors (Basel, Switzerland)    June 12, 2012   Volume 12, Issue 6 8145-8156 doi: 10.3390/s120608145
Olsen E, Andersen PH, Pfau T.The increased variations of temporal gait events when pathology is present are good candidate features for objective diagnostic tests. We hypothesised that the gait events hoof-on/off and stance can be detected accurately and precisely using features from trunk and distal limb-mounted Inertial Measurement Units (IMUs). Four IMUs were mounted on the distal limb and five IMUs were attached to the skin over the dorsal spinous processes at the withers, fourth lumbar vertebrae and sacrum as well as left and right tuber coxae. IMU data were synchronised to a force plate array and a motion capture sy...
Re: The effect of hoof angle variations on dorsal lamellar load in the equine hoof.
Equine veterinary journal    June 8, 2012   Volume 44, Issue 4 500 doi: 10.1111/j.2042-3306.2012.00586.x
Curtis S.No abstract available
Re: The effect of hoof angles on dorsal laminae load of the equine hoof.
Equine veterinary journal    June 8, 2012   Volume 44, Issue 4 499-500 doi: 10.1111/j.2042-3306.2012.00584.x
Redden RF.No abstract available
Speed and incline during thoroughbred horse racing: racehorse speed supports a metabolic power constraint to incline running but not to decline running.
Journal of applied physiology (Bethesda, Md. : 1985)    June 7, 2012   Volume 113, Issue 4 602-607 doi: 10.1152/japplphysiol.00560.2011
Self ZT, Spence AJ, Wilson AM.We used a radio tracking system to examine the speed of 373 racehorses on different gradients on an undulating racecourse during 33 races, each lasting a few minutes. Horses show a speed detriment on inclines (0.68 m · s(-1) · 1% gradient(-1), r(2) = 0.97), the magnitude of which corresponds to trading off the metabolic cost (power) of height gain with the metabolic cost (power) of horizontal galloping. A similar relationship can be derived from published data for human runners. The horses, however, were also slower on the decline (-0.45 m · s(-1) · 1% gradient(-1), r(2) = 0.92). Human ath...
Tendon structure changes after maximal exercise in the Thoroughbred horse: use of ultrasound tissue characterisation to detect in vivo tendon response.
Veterinary journal (London, England : 1997)    June 1, 2012   Volume 194, Issue 3 338-342 doi: 10.1016/j.tvjl.2012.04.024
Docking SI, Daffy J, van Schie HT, Cook JL.Investigations into the response of the superficial digital flexor tendon (SDFT) of the Thoroughbred horse to mechanical stimuli have been limited to in vitro cell culture studies focused primarily on gene expression of critical matrix proteins. It is uncertain how well in vitro outcomes translate to the tendon of the horse during exercise. The current study examined changes in tendon structure in response to maximal exercise using ultrasound tissue characterisation (UTC) to scan the SDFT prior to and after competitive racing. UTC uses contiguous transverse ultrasound images to assess the dyna...
Dynamic properties of a dirt and a synthetic equine racetrack surface measured by a track-testing device.
Equine veterinary journal    May 16, 2012   Volume 45, Issue 1 25-30 doi: 10.1111/j.2042-3306.2012.00582.x
Setterbo JJ, Fyhrie PB, Hubbard M, Upadhyaya SK, Stover SM.Racetrack surface is a risk factor for Thoroughbred racehorse injury and death that can be engineered and managed. To investigate the relationship between surface and injury, the mechanical behaviour of dirt and synthetic track surfaces must be quantified. Objective: To compare dynamic properties of a dirt and a synthetic surface in situ using a track-testing device designed to simulate equine hoof impact; and to determine the effects of impact velocity, impact angle and repeated impact on dynamic surface behaviour. Methods: A track-testing device measured force and displacement during impact ...
Morphometrical study of bony elements of the forelimb fetlock joints in horses.
Anatomia, histologia, embryologia    May 10, 2012   Volume 42, Issue 1 9-20 doi: 10.1111/j.1439-0264.2012.01158.x
Alrtib AM, Philip CJ, Abdunnabi AH, Davies HM.There are many reports describing fractures in the bony elements of the equine fetlock joint and a few of these discuss possible relationships of these fractures to the mechanical loading of these bones. The likelihood of fracture must be related to the size and shape of bones involved, but information concerning the normal range in size and shape of these bones in horses is lacking. This study aimed to identify morphometrical variations of these bones within different groups of horses. Right and left metacarpal, proximal phalangeal and proximal sesamoid bones were collected from 10 Thoroughbr...
Comparison of an inertial sensor system of lameness quantification with subjective lameness evaluation.
Equine veterinary journal    May 6, 2012   Volume 44, Issue 6 652-656 doi: 10.1111/j.2042-3306.2012.00571.x
McCracken MJ, Kramer J, Keegan KG, Lopes M, Wilson DA, Reed SK, LaCarrubba A, Rasch M.Subjective evaluation of mild lameness has been shown to have poor interobserver reliability. Traditional methods of objective lameness evaluation require specialised conditions and equipment. Wireless inertial sensor systems have been developed to allow for simple, rapid, objective lameness detection in horses trotted over ground. Objective: The purpose of this study was to compare the sensitivities of an inertial sensor system and subjective evaluation performed by experienced equine practitioners at detecting lameness in horses. We hypothesised that the inertial sensor system would identify...
Proximal hindlimb flexion in the horse: effect on movement symmetry and implications for defining soundness.
Equine veterinary journal    May 6, 2012   Volume 44, Issue 6 657-663 doi: 10.1111/j.2042-3306.2012.00576.x
Starke SD, Willems E, Head M, May SA, Pfau T.Flexion tests are a common tool during the prepurchase and clinical lameness examination, yet studies quantifying the effect of flexion, apart from distal forelimb flexion in sound horses, are sparse. Objective: To investigate the effect of proximal hindlimb flexion on perceivable and measurable changes in movement symmetry in horses with objective movement symmetry falling within the margins of 'sound'. Methods: Thirteen horses, selected based on objective movement symmetry, were instrumented with inertial sensors on left and right tuber coxae and over the os sacrum. Vertical movement symmetr...
The development of clinical tools based on biomechanical research.
Veterinary journal (London, England : 1997)    May 5, 2012   Volume 192, Issue 2 129-130 doi: 10.1016/j.tvjl.2012.02.011
Roepstorff L.No abstract available
A surface roughness comparison of cartilage in different types of synovial joints.
Journal of biomechanical engineering    April 10, 2012   Volume 134, Issue 2 021006 doi: 10.1115/1.4005934
Smyth PA, Rifkin RE, Jackson RL, Hanson RR.The naturally occurring structure of articular cartilage has proven to be an effective means for the facilitation of motion and load support in equine and other animal joints. For this reason, cartilage has been extensively studied for many years. Although the roughness of cartilage has been determined from atomic force microscopy (AFM) and other methods in multiple studies, a comparison of roughness to joint function has not be completed. It is hypothesized that various joint types with different motions and regimes of lubrication have altered demands on the articular surface that may affect ...
Accuracy and precision of hind limb foot contact timings of horses determined using a pelvis-mounted inertial measurement unit.
Journal of biomechanics    April 5, 2012   Volume 45, Issue 8 1522-1528 doi: 10.1016/j.jbiomech.2012.03.014
Starke SD, Witte TH, May SA, Pfau T.Gait analysis using small sensor units is becoming increasingly popular in the clinical context. In order to segment continuous movement from a defined point of the stride cycle, knowledge about footfall timings is essential. We evaluated the accuracy and precision of foot contact timings of a defined limb determined using an inertial sensor mounted on the pelvis of ten horses during walk and trot at different speeds and in different directions. Foot contact was estimated from vertical velocity events occurring before maximum sensor roll towards the contralateral limb. Foot contact timings mat...
Finite element analysis in 3-D models of equine cheek teeth.
Veterinary journal (London, England : 1997)    March 30, 2012   Volume 193, Issue 2 391-396 doi: 10.1016/j.tvjl.2012.02.013
Cordes V, Gardemin M, Lüpke M, Seifert H, Borchers L, Staszyk C.Periodontal diseases occur frequently in equine dentistry and excessive strain in biological tissues is assumed to be a predisposing factor in their development. Finite element (FE) analysis enables strains and stresses occurring in the periodontium to be calculated and is a useful tool for testing this hypothesis. The current study aimed to establish reliable 3-D models from equine maxillary and mandibular cheek teeth for use in FE simulations, with particular attention to the detailed construction of the periodontal ligament (PDL). Age-related morphological aspects of the teeth and the perio...
Resistance of equine tibiae and radii to side impact loads.
Equine veterinary journal    March 20, 2012   Volume 44, Issue 6 714-720 doi: 10.1111/j.2042-3306.2012.00560.x
Piskoty G, Jäggin S, Michel SA, Weisse B, Terrasi GP, Fürst A.There are no detailed studies describing the resistance of equine tibiae and radii to side impact loads, such as a horse kick and a better understanding of the general long bone impact behavioural model is required. Objective: To quantify the typical impact energy required to fracture or fissure an equine long bone, as well as to determine the range and time course of the impact force under conditions similar to that of a horse kick. Methods: Seventy-two equine tibiae and radii were investigated using a drop impact tester. The prepared bones were preloaded with an axial force of 2.5 kN and wer...
Contribution of dynamic calibration to the measurement accuracy of a pressure plate system throughout the stance phase in sound horses.
Veterinary journal (London, England : 1997)    March 3, 2012   Volume 193, Issue 2 471-474 doi: 10.1016/j.tvjl.2012.01.029
Oosterlinck M, Pille F, Sonneveld DC, Oomen AM, Gasthuys F, Back W.The aim of this study was to evaluate the accuracy of the vertical force curve of a pressure plate (PP) using dynamic calibration with a force plate (FP) in six sound Warmblood horses. The animals were walked and trotted over a combined PP-FP system sampling at 250 Hz. Five valid measurements of each forelimb were collected. The recalibration factor (RF), the ratio between the calibrated and raw PP data, was evaluated in each timeframe throughout the stance phase. Following dynamic calibration, the vertical force curve of the PP demonstrated a characteristic biphasic pattern at the walk and ty...
Comparison of an inertial sensor system with a stationary force plate for evaluation of horses with bilateral forelimb lameness.
American journal of veterinary research    March 1, 2012   Volume 73, Issue 3 368-374 doi: 10.2460/ajvr.73.3.368
Keegan KG, MacAllister CG, Wilson DA, Gedon CA, Kramer J, Yonezawa Y, Maki H, Pai PF.To assess the analytic sensitivity of an inertial sensor system for detection of the more severely affected forelimb in horses with bilateral lameness. Methods: 18 adult horses with forelimb lameness. Methods: Horses were fitted with inertial sensors and evaluated for lameness with a stationary force plate as they were trotted in a straight line. Inertial sensor-derived measurements for vertical head movement asymmetry (HMA) and vector sum (VS) of maximum and minimum head height differences between right and left halves of the stride were used to predict differences in mean peak vertical force...
Effects of mineral content on the fracture properties of equine cortical bone in double-notched beams.
Bone    February 25, 2012   Volume 50, Issue 6 1275-1280 doi: 10.1016/j.bone.2012.02.018
McCormack J, Stover SM, Gibeling JC, Fyhrie DP.We recently developed a method to measure cortical bone fracture initiation toughness using a double-notched beam in four-point bending. This method was used to test the hypothesis that mineralization around the two notch roots is correlated with fracture toughness and crack extension (physical damage). Total energy absorbed to failure negatively correlated with average mineralization of the beam (r(2)=0.62), but not with notch root mineralization. Fracture initiation toughness was positively correlated to mineralization at the broken notch root (r(2)=0.34). Crack length extension at the unbro...
Use of a pressure plate to analyse the toe-heel load redistribution underneath a normal shoe and a shoe with a wide toe in sound warmblood horses at the walk and trot.
Research in veterinary science    February 17, 2012   Volume 93, Issue 2 1026-1031 doi: 10.1016/j.rvsc.2012.01.010
Oomen AM, Oosterlinck M, Pille F, Sonneveld DC, Gasthuys F, Back W.The objective of this study was to use a pressure plate to quantify the toe-heel load redistribution in the forelimbs of sound warmblood horses with normal shoes and shoes with a wide toe and narrow branches, used empirically in the treatment of superficial digital flexor tendon or suspensory ligament injuries. In a crossover-design study, six horses, randomly shod with normal shoes and shoes with a wide toe, were led over a dynamically calibrated pressure plate to record data from both forelimbs. There were no significant differences between both shoes in the toe-heel index of stance time, pe...
Comprehensive surface-based morphometry reveals the association of fracture risk and bone geometry.
Journal of orthopaedic research : official publication of the Orthopaedic Research Society    January 17, 2012   Volume 30, Issue 8 1277-1284 doi: 10.1002/jor.22062
Wang D, Shi L, Griffith JF, Qin L, Yew DT, Riggs CM.Surface-based morphometry method is advantageous in its objectivity and increased capability in detecting focal morphological changes, but has not been applied in bone-related research. Orthopedics research in human has confirmed the association of the bone geometry in proximal femur and its fracture. In this study, surface-based morphometry is used to test the hypothesis that there is relationship between bone geometry and fracture risk of the proximal sesamoid bone (PSB) in forelimbs of Thoroughbred racehorses. The PSB surfaces were extracted from CT images of nonfractured forelegs (i.e., ri...
A method to minimise error in 2D-DLT reconstruction of non-planar markers filmed with a moving camera.
Computer methods in biomechanics and biomedical engineering    January 6, 2012   Volume 16, Issue 9 929-936 doi: 10.1080/10255842.2011.644540
Holden-Douilly L, Pourcelot P, Chateau H, Falala S, Crevier-Denoix N.This article describes a method that allows estimating, with the 2D version of the direct linear transformation (DLT), the actual 2D coordinates of a point when the latter is not strictly in the calibration plane. Markers placed in vertical line, above, below and in the centre of a horizontal calibration plane were filmed by a moving camera. Without correction, strong errors (up to 64.5%) were noticed for markers out of the calibration plane. After correction, calculated coordinates were consistent with actual values (error < 0.55%). The method was then applied to slip distance measuremen...
1 37 38 39 40 41 86