Cadaver studies involving horses provide valuable insights into equine anatomy, pathology, and surgical techniques. These studies involve the examination and dissection of deceased horses to better understand the structure and function of various bodily systems. By utilizing cadavers, researchers and veterinary students can gain hands-on experience in identifying anatomical features, understanding disease processes, and refining surgical skills without the ethical concerns associated with live animal experimentation. Cadaver studies also contribute to the development of new diagnostic and therapeutic approaches by allowing for detailed exploration of equine anatomy and pathology. This page compiles peer-reviewed research studies and scholarly articles that explore the methodologies, findings, and applications of cadaver studies in equine science.
Scrivani PV, Barthez PY, Léveillé R, Schrader SC, Reed SM.Three patients (1 dog, 2 horses) are described where myelography was complicated, purportedly by injection of contrast medium into the meninges superficial to the subarachnoid space. Contrast medium injected in this location in a cadaver tended to accumulate dorsally within the vertebral canal, deep to the dura mater but superficial to the subarachnoid space. The ventral margin of the pooled contrast medium had a wavy or undulating margin and the dorsal margin was smooth. Pooled contrast medium was believed to be sequestered within the structurally weak dural border cell layer between the dura...
Hanson PD, Hartwig H, Markel MD.This study compares the mechanical properties of three methods of equine ulnar fixation: dynamic compression plating, pins and wires tension band, and a prototype grip system. Methods: The mechanical properties of dynamic compression plating, pins and wires tension band, and a prototype grip system repair of equine ulnar fractures were evaluated in a cadaveric osteotomy model. Methods: Fifteen pairs of the radius and ulna from equine cadavers. Methods: The three repair techniques were evaluated to mimic the pull of the triceps brachii muscle in single cycle to failure and in cyclic fatigue loa...
Baptiste K.The pharyngeal orifice of the equine auditory tube has not been adequately described. Its larger size and position, further rostral within the nasopharynx compared with other species, cannot be easily explained, but could be important for the proposed brain-cooling function of the guttural pouches; however, unlike other species, it may not be the sole regulator of auditory tube aeration. A 'second orifice' (representing the final entrance to the auditory tube diverticulum) deserves recognition in performing a role in air exchange between the auditory tube, diverticulum and middle ear. The resu...
McD○ LA, Stover SM, Taylor KT.To determine the monotonic mechanical properties of osteotomized adult equine tibiae stabilized with two dynamic compression plates (DCP) and to compare the mechanical properties with those of intact tibiae and in vivo loads. Methods: The compressive, bending, and torsional mechanical properties of plated and intact tibiae were assessed in vitro. Methods: Twelve pairs of adult equine tibiae. Methods: Tibiae were loaded in axial compression, craniocaudal 3-point bending, or torsion in external rotation in a single cycle to failure. Mechanical properties were determined from load-displacement da...
Ruohoniemi M, Raekallio M, Tulamo RM, Salonius K.One hundred Finnhorse cadaver front feet were measured and examined both radiographically and visually to report the incidence of various foot problems and their relationship to ossification of the cartilages of the foot. Ossification extending above the proximal border of the navicular bone and/or separate centres of ossification were found in 36 feet, and the lateral cartilages showed more ossification than the medial cartilages. The feet were generally broad with well developed frogs, but the long toe-low heel syndrome was a relatively common finding. Ossification of the cartilages correlat...
Keegan KG, Wilson DA, Kreeger JM, Ellersieck MR, Kuo KC, Li Z.To evaluate the distribution of mepivacaine hydrochloride after distal interphalangeal (DIP) joint injection in horses. Methods: Prospective, uncontrolled study. Methods: 10 adult horses. Methods: 30 minutes before euthanasia, 8 ml of 2% mepivacaine hydrochloride was injected into the dorsal pouch of a forelimb DIP joint. Synovial tissue from the DIP joint and podotrochlear (navicular) bursa and bone tissue from the medullary cavity of the distal sesamoid (navicular) bone were taken from both forelimbs immediately after death. All synovial and bone specimens were analyzed for tissue concentrat...
Matthews GL, Keegan KG, Graham HL.To determine effects of tendon grip technique on in vitro surface strain measurements of equine deep digital flexor tendon (DDFT) when loaded in tension. Methods: 12 hind limb DDFT from 8 adult horses (mean age, 9.8 years [range, 4.5 to 17 years]; mean body weight, 472 kg [range, 450 to 509 kg]), with no clinical evidence of hind limb lameness. Methods: After calibration, liquid mercury strain gauges were sutured to plantar surfaces of the tendons at distal (position 1), middle (position 2), and proximal (position 3) metatarsal regions. Each tendon was affixed to a materials testing machine (d...
Bell BT, Baker GJ, Abbott LC, Foreman JH, Kneller SK.The vascular anatomy of the ethmoidal area in six normal horses and two normal ponies was studied using vascular-corrosion casts. The major arterial supply to the ethmoidal area stems from an intracranial source. The internal and external ethmoidal arteries anastomose on the rostral intracranial surface of the cribriform plate to form the arterial ethmoidal rete which arborizes and passes through the perforations of the cribriform plate to supply the ethmoid labyrinth. A minor arterial supply to the ventral portion of the ethmoid labyrinth stems from a small caudal nasal branch of the sphenopa...
Kraus BL, Kirker-Head CA, Kraus KH, Jakowski RM, Steckel RR.The vascular and microvascular anatomy of the equine deep digital flexor tendon (DDFT) within the digital sheath was studied by injecting the vasculature with either colored latex or barium sulphate for radiographic, microangiographic, histologic, and computed tomographic (CT) evaluation. Consecutive 4-mm thick two-dimensional CT slice data were reconstructed to 3-dimensional volumetric images to enhance spatial evaluation of the blood supply. Gross dissection and angiographic studies identified three major vascular sources. Above the fetlock, the DDFT was supplied by either a branch of the me...
Parente EJ, Nunamaker DM.Six forelimb specimens from three adult horses had the fetlock joint fused by application of a dorsal plate and by a screw placed in lag fashion through the metacarpus to each proximal sesamoid bone. Five specimens were instrumented on the central dorsal surface of the plate with a single rosette strain gage, and the plate of the sixth specimen was instrumented with four longitudinally oriented single-axis strain gages. The specimens were loaded axially in compression to 4,000 N in a cast (test 1), in a cast with a heel block (test 2), and uncast (test 3). The principal angle of strain in all ...
Trostle SS, Wilson DG, Stone WC, Markel MD.The purposes of this study were to mechanically determine the optimal tissue bite size and to evaluate seven suture materials at their largest commercially available size for breaking strength and stiffness using cadaveric adult equine linea alba. Soft tissues were removed from the abdominal fascia of 16 adult horses. Individual test sections were created from the entire linea alba and labeled (1 through 6) starting at the umbilicus and extending craniad. A single biomechanical test was performed on each test section. Tissue bite size (3, 6, 9, 12, 15, 18, and 21 mm) significantly altered brea...
McClure SR, Watkins JP, Bronson DG, Ashman RB.Axial stability of equine oblique proximal phalangeal osteotomies with application of the standard short limb cast or 1 of 3 configurations of transfixation casts was determined in vitro. Transfixation cast methods included use of parallel pins, divergent pins, or parallel pins incorporating a metal walking bar. Displacement at the osteotomy was recorded for each limb at 4,448 N. Standard short limb casts provided significantly (P = 0.0002) less axial stability than did any form of transfixation cast. Significant differences were not found between the 3 transfixation casts.
Ward NI, Savage JM.The elemental (Br, Cd, Cr, Cu, Mn, Ni, Pb, Se, V, and Zn) content of blood and wool or hair from animals (sheep, horses and alpacas) exposed to motor vehicle emissions alongside the London Orbital (M25) motorway is reported. Elemental values were determined by inductively coupled plasma mass spectrometry (ICP-MS) quality control assessment using flameless atomic absorption spectroscopy (for Pb, correlation coefficients of whole blood r = +0.87, and hair r = +0.82), and replicate (n = 10) analysis of the international reference material IAEA A13 Animal Blood. For Pb very good agreement was obta...
Dik KJ, Boroffka S, Stolk P.Ultrasonography was used with 6 normal cadaver forelimbs of Dutch Warmblood horses to delineate the ultrasonographic anatomy of the palmar pastern region, with emphasis on the proximal digital annular ligament. Using a 5.5 MHz sector scanner, the thin proximal digital annular ligament was not visible on offset sonograms. Only if the digital sheath in the normal limb was distended was the distal border of this ligament outlined. In all normal limbs the palmarodistal thickness of the combined skin-proximal digital annular ligament layer in the mid-pastern region was 2 mm. The flexor tendons and ...
Baker SJ, Gerring EL.Intragastric pH monitoring was investigated in ponies. In cadaver stomachs, close contact with the mucosa led to high pH readings if nonweighted electrodes were used. However, pH recorded by weighted electrodes was markedly less affected by mucosal contact (P < 0.001). The latter were used for subsequent trials. In vivo, high correlations were found between pH recorded by weighted electrodes with or without a wire guard to prevent mucosal contact (correlation, r = 0.866; P < 0.001). Readings from each correlated well with those from simultaneous gastric aspirates (r = 0.774 and r = 0.807...
Greene EA, Smith KR, Pendergraft JS, Raub RH, Arns MJ.When the decision was made to euthanatize an acutely laminitic Thoroughbred broodmare, graduate students from the Department of Animal Sciences and Industry reconstructed the skeleton for use as a teaching tool. The reproductive and gastrointestinal tracts were removed and preserved in formalin. The hide, muscle, tendons, ligaments, and organs were removed, and the bones were boiled in water for > or = 48 h to remove all remaining tissue. After boiling, the bones were soaked in gasoline to remove fat from the marrow cavities and then soaked in a bleach/detergent mixture as a final cleaning ...
Hay WP, Tulleners EP, Ducharme NG.An extralaryngeal approach to partial arytenoidectomy in the horse was developed by in vitro experiments on isolated larynges and then on intact equine cadavers. The goals of the approach were to preserve the laryngeal mucosa, eliminate the need for a laryngotomy or tracheotomy, and minimize postoperative complications. The new approach was evaluated in seven horses with normal upper respiratory tracts. Left laryngeal hemiplegia was surgically created, and, after a 30-day convalescence, left partial arytenoidectomy was performed using an extralaryngeal approach. The left-to-right hemilaryngeal...
Vacek JR, Welch RD, Honnas CM.An arthroscopic approach to the palmaroproximal or plantaroproximal pouch of the distal interphalangeal joint was developed in six cadaver limbs and seven limbs of three clinically normal horses. The dorsal aspect of the proximal border and the proximal articular margin of the distal sesamoid (navicular) bone, the palmar aspect of the distal articular margin of the middle phalanx, the collateral sesamoidean ligaments of the distal sesamoid bone, and the joint capsule attachments were readily accessible. Distending the joints with fluid gave access to portions of the articular surface between t...
Major MD, Grant BD, White KK, Ratzlaff MH, Gallina AM, Crawley GR.Mechanical properties of equine suspensory apparatus preparations and three braided synthetic prostheses were evaluated in vitro. Force versus displacement plots and failure modes were recorded from single load-to-failure testing in 18 cadaver limbs before and after replacement of each suspensory apparatus with a prosthesis. Mean load at failure, energy to failure, and stiffness values of polytetrafluoroethylene (PTFE) prostheses were lower than those of the suspensory apparatus and aramid prosthesis. The PTFE prosthesis failed by elongation or rupture of the prosthesis. Mechanical properties ...
Desjardins MR, Hurtig MB, Palmer NC.Two 10 mm thick osteochondral grafts were harvested from the lateral aspect of the lateral trochlear ridge of the left talus in each of 10 anesthetized horses. The grafts were frozen in a 7.5% DMSO solution and stored in liquid nitrogen. The horses were anesthetized again on day 14 and the thawed grafts were press-fitted into drill holes in the trochlear ridges of the right stifle. A fresh graft was transferred from the right hock to the left stifle. To control for the effects of surgery, another fresh graft was transferred from the right stifle to the left stifle. The result was two grafts in...
Shoemaker RS, Bertone AL, Mohammad LN, Arms SW.Effects of longitudinal compression before and after transection of the accessory ligament of the superficial digital flexor (SDF) muscle were measured in eight equine cadaver forelimbs. When compression was increased from 890 N to 3115 N, the metacarpophalangeal (MCP) and carpal joints hyperextended 20 degrees and 4 degrees, respectively, and strain in the SDF and deep digital flexor tendons was increased 3.5% and 1.4%, respectively. The accessory ligament did not elongate. Immediately after transection of the accessory ligament at 3115 N load, a 2.8 mm gap formed between the transected ends ...
Jann H, Henry G, Berry A, Cash L.Twenty cadaver limbs of adult horses were examined by arthrographic examination of the distal interphalangeal joint. The joint capsule and space is described. Comparison is made with existing descriptions.
Schmotzer WB, Timm KI.Successful diagnostic local anesthesia is dependent upon a thorough knowledge of appendicular anatomy, application of correct technique, and accurate interpretation. Use of cadaver specimens to review anatomy and practice needle placement is strongly recommended. A marker solution, such as new methylene blue, can be injected into cadaver limbs, which can be subsequently dissected to verify accuracy. Detailed interpretation of local anesthetic blocks in the lame horse reaches beyond the scope of this article. Interpretive difficulties, however, can be responsible for the failure of a block to p...
Lees MJ, Bowen CV, Fretz PB, Leach DH.Areas of skin vascularized by large axial vessels potentially suitable for microvascular anastomosis were investigated in 10 horse cadavers. Eleven such areas were dissected, and the skin over the flank region vascularized by the deep circumflex iliac artery was most suitable. The anatomy of this area was further defined, using angiography and latex injection studies on 10 cadavers.
Kotzé SH.The arteries supplying the ileocaecal junctions of 7 horses were injected with latex via the A. ileocolica and dissected macroscopically. The same basic pattern emerged whereby a single papillary artery arising from the R. ilei mesenterialis, supplied all aspects of the ileocaecal papilla. In one instance, the papillary artery arose directly from the ileocolic artery. No collateral arterial supply to the ileocaecal junction was present in any of the specimens dissected.
Hunt DA, Snyder JR, Morgan JP, Stover SM, Pool RR, Pascoe JR.Femoral neck and proximal epiphyseal lengths were measured in 37 femurs from 19 cadaver foals that were 1 day to 12 months old to determine the applicability of a human interfragmentary compression system to equine femoral capital physeal fractures. Because components of the implant system are available only in fixed sizes, its use was possible in foals older than 5 weeks of age, but not in younger foals. The 135 degree angle plate conformed best to the equine femur. Femoral capital physeal fractures were created surgically and repaired with the implant system in three foals. Fracture stabilit...
Nixon AJ.Periarticular anatomy and techniques for arthroscopic access to the equine elbow were studied in six joints from cadavers. Caudomedial and craniolateral approaches were evaluated subsequently in 11 anesthetized horses. The caudomedial approach was made between the flexor carpi radialis and flexor carpi ulnaris muscle bellies. Most of the caudal articular surfaces of the humeral condyles, the caudal perimeter of the radius, and the trochlear notch and portions of the anconeal process of the ulna could be identified. The voluminous caudal joint capsule cul-de-sac proximal to the anconeal process...
Anke M, Kośla T, Groppel B.The Cd status of animals is best reflected by kidneys and much worse by liver and hair. Breed (heavy- and warm-blooded horses) only took an insignificant effect on the Cd content of kidneys and liver. On the average, however, warm-blooded horses stored more Cd than heavy ones. Geldings from Cd-exposed living areas accumulated insignificantly more Cd in liver, kidneys and hair than mares. The influence of age on the Cd content of kidneys and liver of Cd-exposed horses was significant. The Cd exposure of a living area was very well reflected by kidneys and liver. On the average, horses from two ...
Beard WL, Lohse CL, Robertson JT.The blood supply to the descending colon of the horse was studied by gross dissection and methyl methacrylate corrosion casts. The arterial supply is derived from the left colic artery and cranial rectal artery with the left colic artery supplying approximately the proximal three fourths. Each artery gives off four to eight arcuate arteries that form a series of anastomosing arcades. The arcade pattern continues to form a marginal artery that parallels the long axis of the colon. Small branches from the marginal artery anastomose with adjacent branches to form a secondary arcade. The secondary...
Ford TS, Ross MW, Orsini PG.Three techniques for inducing analgesia of the proximal metacarpal region were evaluated for the frequency of inadvertent injection into the middle carpal and carpometacarpal joints. Using methylene blue solution as a marker dye and 30 fresh cadaver specimens each, three clinicians performed either 30 infiltrations at the origin of the suspensory ligament (method A), 30 palmar and palmar metacarpal nerve blocks at the proximal end of the metacarpus (method B), or 30 palmar and palmar metacarpal nerve blocks at the distal aspect of the accessory carpal bone (method C). The frequency of inadvert...
Sod GA, Mitchell CF, Hubert JD, Martin GS, Gill MS.To compare monotonic biomechanical properties and fatigue life of a 5.5 mm broad limited-contact dynamic compression plate (5.5-LC-DCP) fixation with a 4.5 mm broad LC-DCP (4.5-LC-DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. Methods: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Methods: Adult equine cadaveric MC3 bones (n=18 pair). Methods: MC3 were divided into 3 test groups (6 pairs each) for: (1) 4-point bending single cycle to failure testing; (2) 4-point bendi...
Pohlin F, Edinger J, Jenner F, Egerbacher M.To describe the anatomic and histologic features of the collateral ligaments (CLs) of the metacarpophalangeal (MCP) and metatarsophalangeal (MTP) joints in cadaveric limbs obtained from nonlame horses and to compare the histologic findings with the ultrasonographic appearance of the CLs. Methods: Medial and lateral CLs of the MCP and MTP joints of 28 limbs (16 forelimbs and 12 hind limbs) from 9 adult nonlame horses euthanized for reasons unrelated to the study. Methods: 26 limbs of 8 horses were examined by ultrasonography immediately after euthanasia. Postmortem gross and histologic examinat...
Rubio-Martínez LM, Bracamonte JL, Tompkins S, Villarino NF.To describe a transthecal approach to the palmar pouch of the distal interphalangeal joint (DIPJ) in horses and compare it with the conventional blind arthroscopic technique. Methods: Ex vivo study. Methods: Cadaver forelimbs (n = 26 pairs) from mature horses. Methods: One limb from each pair was randomly assigned to each arthroscopic approach (conventional or transthecal). The conventional arthroscopic approach was performed as previously described and the transthecal approach was performed through sharp dissection of the distal reflection of the digital flexor tendon sheath (DFTS). The propo...
Bueno AC, Galuppo LD, Taylor KT, Jensen DG, Stover SM.To compare the mechanical shear strengths and stiffnesses obtained from in vitro testing of a simulated complete third carpal bone (C3) frontal plane radial facet slab fracture (osteotomy) stabilized with either a 4/5 Acutrak (AT) compression screw or a 4.5-mm AO cortical bone (AO) screw inserted in lag fashion. Drilling, tapping, and screw insertion torques, forces, and times also were compared between AT and AO implants. Methods: In vitro biomechanical assessment of site preparation, screw insertion, and shear failure test variables of bone screw stabilized simulated C3 slab fracture in pair...
Davis JG, Ragle CA, Hanna A, DeNome AT.To determine the location of the deep and superficial caudal epigastric arteries in relation to 3 midline positions and the relationship between the location of these arteries, body circumference, and body condition score. Methods: Descriptive anatomical study. Methods: Nine horses, aged 1-28 years (mean 10.61 ± 8.89 SD). Methods: Body condition score and body circumference were measured prior to euthanasia. Angiographic studies of the deep and superficial caudal epigastric arteries were performed on resected abdominal walls. The distances between the deep and the superficial caudal epiga...
Roe HA, Biedrzycki AH, Davenport PW, Freeman DE, Porter EG, McCarrel TM.To develop 3D models of larynges to compare arytenoid abduction measurements between specimens and models, and to investigate the anatomic feasibility of placing an implant across the cricoarytenoid joint (CAJ) with or without arthrotomy. Methods: Cadaveric equine larynges (n = 9). Methods: Equine larynges underwent sequential CT scans in a neutral position and with 2 arytenoid treatments: bilateral arytenoid abduction (ABD) and bilateral arytenoid abduction after left cricoarytenoid joint arthrotomy (ARTH). Soft tissue, cartilage, and luminal volume 3-dimensional models were generated. Rima g...
Rahm C, Ito K, Auer J.To compare acute fixation stability and insertion effort of cortex bone screws with and without a shaft inserted in lag fashion in equine metacarpal (metatarsal, MC(T)III) bone. Methods: Screw types with independent variables of screw diameter (4.5 or 5.5 mm) and shaft type (without shaft, with 20-mm shaft, or with 25-mm shaft) were studied. Bone specimens cut from distal equine MC(T)III condyles were used. After screw insertion in lag fashion into 2 bone blocks with an instrumented device, shear tests were conducted in a mechanical testing machine. Outcome variables of peak insertion torque, ...
Major MD, Grant BD, White KK, Ratzlaff MH, Gallina AM, Crawley GR.Mechanical properties of equine suspensory apparatus preparations and three braided synthetic prostheses were evaluated in vitro. Force versus displacement plots and failure modes were recorded from single load-to-failure testing in 18 cadaver limbs before and after replacement of each suspensory apparatus with a prosthesis. Mean load at failure, energy to failure, and stiffness values of polytetrafluoroethylene (PTFE) prostheses were lower than those of the suspensory apparatus and aramid prosthesis. The PTFE prosthesis failed by elongation or rupture of the prosthesis. Mechanical properties ...
Averay K, van Galen G, Ward M, Verwilghen D.Equine small intestinal resection and anastomosis is a procedure where optimizing speed, without compromising integrity, is advantageous. There are a range of different needle holders available, but little is published on the impact surgical instrumentation has on surgical technique in veterinary medicine. The objectives of this study were to investigate if the needle holder type influences the anastomosis construction time, the anastomosis bursting pressure and whether the bursting pressure is influenced by the anastomosis construction time. Single layer end-to-end jejunojejunal anastomoses w...
Kraus BL, Kirker-Head CA, Kraus KH, Jakowski RM, Steckel RR.The vascular and microvascular anatomy of the equine deep digital flexor tendon (DDFT) within the digital sheath was studied by injecting the vasculature with either colored latex or barium sulphate for radiographic, microangiographic, histologic, and computed tomographic (CT) evaluation. Consecutive 4-mm thick two-dimensional CT slice data were reconstructed to 3-dimensional volumetric images to enhance spatial evaluation of the blood supply. Gross dissection and angiographic studies identified three major vascular sources. Above the fetlock, the DDFT was supplied by either a branch of the me...
Giusto G, Iotti B, Sammartano F, Valazza A, Gandini M.The aim of this study is to compare handsewn and stapled jejunocecal anastomosis with different stomal lengths in terms of anatomical differences. Group 1 underwent a two-layer handsewn jejunocecal side-to-side anastomosis (HS); Group 2 received a stapled jejunocecal side-to-side anastomosis (GIA). Each group was divided into two subgroups (HS80 and HS100, GIA80 and GIA100). Specimens were inflated and CT scanned. The stomal/jejunal area ratio and blind end pouch volume/area were measured and compared. Effective length of the stoma was measured and compared with the initial length. Stomal/jeju...
Endo H, Nguyen ST, Yoshida M, Kudo K.The three-dimensionally real position and movement of the scapula in the lateral side of the ribcage could not be clarified in the horse, since the body size of the horse is too large to apply the CT scanning and image analysis methods. In this study, therefore, we examined the position and the movability of scapula using a carcass of the Falabella which is one of the smallest breeds of the horse. The whole skeletal system in thoracic part of the Falabella could be three-dimensionally observed by CT scanning method. The three-dimensional images show that the scapula cranially slides and the ve...
Sod GA, Riggs LM, Mitchell CF, Martin GS, Gill MS.To compare number of cycles to failure for palmarodorsal 4-point bending of a modified 5.5 mm broad locking compression plate (M5.5-LCP) fixation with a 5.5 mm broad LCP (5.5-LCP) fixation used to repair osteotomized equine third metacarpal (MC3) bones. Methods: In vitro biomechanical testing. Methods: Adult equine cadaveric MC3 bones (n=6 pairs). Methods: An 8-hole, M5.5-LCP, obtained by having a 1.0 mm thickness removed from the bone contact portion of the 5.5-LCP, was applied to the dorsal surface of 1 randomly selected MC3 from each pair, and an 8-hole, 5.5-LCP was applied dorsally to the ...
Adams MN, Turner TA.Forelimbs from 3 anesthetized horses and 16 fresh cadaver horses were used to describe the endoscopic anatomy of the intertubercular bursa and outline the surgical portals that provide the greatest access to structures within the bursa. A lateral arthroscopic portal was made proximal to the deltoid tuberosity of the humerus into the distal bursal recess. A second portal was created proximal to the humeral tubercles that entered the proximal bursal space. These approaches provided consistent viewing and instrument access to the lateral intertuberal groove, the greater and intermediate humeral t...
Christensen BW, Danielson JA.Recent publications have revealed inadequacies in the veterinary training of future equine practitioners. To help address this problem, a 2-week Equine Clinical Skills course was designed and implemented to provide fourth-year veterinary students with opportunities to have hands-on experience with common equine clinical skills using live animals and cadavers. Alumni and employers of alumni were surveyed to determine whether or not students participating in the course were more competent performing clinical skills during their first year post-graduation than those who had not participated in th...
Sasaki N, Takakuwa J, Yamada H, Mori R.To evaluate effectiveness of allogeneic bone screws and pins for internal fixation of midbody transverse fractures of equine proximal sesamoid bones (PSBs) in vitro. Methods: 14 forelimbs from cadavers of 3-year-old Thoroughbreds. Methods: Allogeneic cortical bone fragments were collected from the limbs of a male Thoroughbred, and cortical bone screws were prepared from the tissue by use of a precision desktop microlathe programmed with the dimensions of a metal cortical bone screw. A midbody transverse osteotomy of each PSB was performed by use of a bone-shaping oscillating saw and repaired v...
Biedrzycki AH, Grant BG, Nemke B, Morello SL, Markel MD.OBJECTIVE To evaluate the biomechanical properties of 4 methods for fusion of the centrodistal and tarsometatarsal joints in horses and compare them among each other and with control tarsi. SAMPLE 24 sets of paired tarsi without substantial signs of osteoarthritis harvested from equine cadavers. PROCEDURES Test constructs (n = 6/type) were prepared from 1 tarsus from each pair to represent surgical drilling; 2 medially to laterally placed kerf-cut cylinders (MLKCs); a single large, dorsally applied kerf-cut cylinder (DKC); and a dorsomedially applied locking compression plate (DMLCP). Construc...
Tsujita H, Brennan AB, Plummer CE, Nakajima N, Hyon SH, Barrie KP, Sapp B, Jackson D, Brooks DE.Chemically defined bioadhesives (CDB) are "two-component reactive adhesives" made from antibiotic food additives. They contain no animal-derived ingredients and are characterized by a high level of self-degradability, low toxicity, and strong bonding properties. Amniotic membrane (AM) transplantation is used to repair severe ocular surface disease in humans and horses. AM requires meticulous suturing to the injured cornea. The purpose of this study is to determine whether CDB can facilitate the suture-less placement and adherence of equine AM to porcine cadaver cornea. Methods: Prospective stu...
Durket E, Kersh K, Dembek K, Riedesel E, Silverstone A, Kraus KH.To determine the influence of plate fixation (locking or dynamic compression) and the site of application (ventral [V] or ventrolateral [VL]) on the resistance to bending of transverse mandibular fractures. Methods: Ex vivo, simple randomized study. Methods: Mandibles harvested from adult equine cadavers (n = 18). Methods: Bilateral osteotomies were created 1 cm caudal to the mental foramen and perpendicular to the long axis of each mandible. Mandibles were fixed with 1 of 3 methods: (1) VL dynamic compression plate (DCP), (2) V-DCP, or (3) VL locking compression plating (LCP). Construct...
Hay WP, Tulleners EP, Ducharme NG.An extralaryngeal approach to partial arytenoidectomy in the horse was developed by in vitro experiments on isolated larynges and then on intact equine cadavers. The goals of the approach were to preserve the laryngeal mucosa, eliminate the need for a laryngotomy or tracheotomy, and minimize postoperative complications. The new approach was evaluated in seven horses with normal upper respiratory tracts. Left laryngeal hemiplegia was surgically created, and, after a 30-day convalescence, left partial arytenoidectomy was performed using an extralaryngeal approach. The left-to-right hemilaryngeal...
Joss R, Baschnagel F, Ohlerth S, Piskoty G, Fürst A, Bischofberger AS. The aim of this study was to compare the potential of an unshod and shod hoof to cause an orbital fracture in the event of a kick. Methods: Thirty-four equine cadaveric orbitae were exposed to a steel or horn impactor in a dropping test set-up. An impactor velocity of 7 m/s was used for both materials. Testing was repeated on the same orbit at a velocity of 10 m/s with the horn impactor if no damage occurred. A high-speed camera was used to analyse the impact process. Physical parameters (peak force and impact duration) were calculated based on quantitative video-tracking. Computed tomog...
Hardeman LC, van der Meij BR, Lamers AA, van der Kolk JH, Back W, Wijnberg ID.In equine medicine the use of Botox® is experimental. Dosages are determined from human treatment-protocols and limited numbers of equine studies. Determination of target-muscle volume can be helpful to extrapolate human dosages. The aim of the study was to calculate a formula enabling the estimation of the deep digital flexor muscle (DDFM) volume based on distances between anatomical landmarks. Nineteen cadaveric limbs were collected and distance A (top of olecranon to Os carpi accessorium) and B (circumference of limb) were measured. Converting mathematical formulas, C was calculated: π ×...
Nunamaker DM, Nash RA.To report development, configuration, application, and results of a tapered-sleeve transcortical pin external skeletal fixation device (TSP ESFD) for use on fractures of the distal aspect of the equine limb. Methods: Optimization analysis of a TSP ESFD was carried out with mechanical testing and review of clinical case outcomes. Methods: Cadaveric adult third metacarpal bones (MC3) for mechanical testing; horses (n=7) with severely comminuted proximal (6; P1) or second (1) phalanx fractures. Methods: Mechanical testing of methods for attachment of TSP to the sidebars were tested as well as opt...
Morisset S, McClure SR, Hillberry BM, Fisher KE.To compare the in vitro holding power and associated microstructural damage of 2 large-animal centrally threaded positive-profile transfixation pins in the diaphysis of the equine third metacarpal bone. Methods: 25 pairs of adult equine cadaver metacarpal bones. Methods: Centrally threaded positive-profile transfixation pins of 2 different designs (ie, self-drilling, self-tapping [SDST] vs nonself-drilling, nonself-tapping [NDNT] transfixation pins) were inserted into the middiaphysis of adult equine metacarpal bones. Temperature of the hardware was measured during each step of insertion with ...
Baptiste K.The pharyngeal orifice of the equine auditory tube has not been adequately described. Its larger size and position, further rostral within the nasopharynx compared with other species, cannot be easily explained, but could be important for the proposed brain-cooling function of the guttural pouches; however, unlike other species, it may not be the sole regulator of auditory tube aeration. A 'second orifice' (representing the final entrance to the auditory tube diverticulum) deserves recognition in performing a role in air exchange between the auditory tube, diverticulum and middle ear. The resu...
James OA, Elce Y, Cillán-Garcia E, Reardon RJM. The aim of this study was to determine whether a clamped drill guide can be used effectively to drill across equine distal third metacarpals and metatarsals and to compare accuracy and speed of a drilling with a hand-held drill guide. Methods: Eighty equine cadaver limbs were divided between four surgeons with varying experience. The limbs were randomly allocated to clamped or hand-held drill guides and placed in a stand in an upright/standing position on a metal table. Drilling times from cis- to trans cortices were measured. Post-drilling computed tomography images were used to assess ...
Kau S, Motter KS, Moser VJ, Kunz JR, Pellachin M, Hartl B.Incisor malocclusions are common in horses. As yet, an evidence-based understanding of incisor occlusal surface angle dynamics and normocclusal range is missing. Orthodontic measuring devices could help unravel this information objectively but imply measurement validation. We evaluated intra- and interexaminer variability of repeated sagittal and transversal incisor occlusal surface angle measures using a commercial orthodontic gauge device (). Five examiners (two experienced, three inexperienced) measured six cadaver heads on 2 consecutive days in a blinded block-randomization design, resulti...
Scilimati N, Angeli G, Di Meo A, Dall'Aglio C, Pepe M, Beccati F.The radiographic, ultrasonographic, and scintigraphic findings of horses with thoracolumbosacral pain have been previously reported. In this study, the computed tomographic appearance of anatomical variations and pathological changes of the equine caudal lumbar region through a post-mortem examination were investigated. A total of 40 horses that had died or were submitted for euthanasia, for reasons unrelated to the study, were included in the study. From all the specimens, the modified vertebral system was adopted to evaluate and describe the four most caudal lumbar vertebrae, which were numb...
Olusa TAO, Davies HMS.Finding an appropriate location for perpendicular positioning of the X-ray machine to produce zero lateromedial (ZLM) and zero dorsopalmar (ZDP) carpal images (views) and finding an acceptable range of rotational variations for measurement of carpal conformational parameters were two major challenges identified during field radiography of equine forelimbs. 16 cadaver forelimbs transacted at antebrachial midshaft from 10 horses (aged 9.13 ± 4.59 years) were axially mounted into a custom-built frame, and the radiographic machine and plate were perpendicularly aligned with the limb. Each limb...
Kane-Smyth J, Taylor SE, García EC, Reardon RJ.To evaluate the frequency of inadvertent penetration of the digital flexor tendon sheath (DFTS) and/or distal interphalangeal joint (DIPJ) when using a direct endoscopic approach to the navicular bursa, and to evaluate an alternate direct approach to the navicular bursa. Methods: Cadaveric study. Methods: Equine cadaver limbs (n = 40 for direct; n = 12 for alternate approach). Methods: Four surgeons performed the direct endoscopic approach to the navicular bursa on 10 limbs each. Frequencies of inadvertent synovial penetration and iatrogenic damage were compared between surgeons. Use of an alt...