Topic:Cardiovascular Health
Cardiovascular health in horses encompasses the study of the heart and blood vessels, focusing on their structure, function, and associated disorders. The equine cardiovascular system is responsible for the circulation of blood, delivering oxygen and nutrients to tissues, and removing waste products. Research in this area includes the examination of cardiac anatomy, the electrophysiology of the heart, and common cardiovascular conditions such as arrhythmias, valvular diseases, and heart murmurs. Diagnostic tools such as echocardiography, electrocardiography, and cardiac biomarkers are utilized to assess cardiovascular function and detect abnormalities. This page compiles peer-reviewed research studies and scholarly articles that explore the physiological mechanisms, diagnostic approaches, and therapeutic strategies related to cardiovascular health in horses.
Transthoracic echocardiography and its limitations in the diagnosis of congenital supernumerary aortic valve in a Thoroughbred. Aortic valve malformation is a common congenital abnormality reported in human medicine. The malformation is characterised by an increased or decreased number of cusps. Anatomical variations of the aortic valve that have been documented in humans include unicuspid, bicuspid, quadricuspid and quinticuspid valves. Two reports described a quadricuspid aortic valve in horses associated with either a ventricular septal defect (VSD) or tetralogy of Fallot. In this case report we describe the clinical and echocardiographic findings of a horse with a quadricuspid aortic valve as single congenital abno...
Morphological variability of the atrioventricular valve cusps in the equine heart. The morphometric studies of the atrioventricular valves are still limited in the horse. Objective: To investigate the anatomy of the atrioventricular valves in the horse, focusing on the morphometric features of the valvular leaflets and the tendinous cords. We hypothesised that accessory leaflets occur commonly and exist as independent structures in the atrioventricular valves of the horse. Methods: Descriptive anatomical study. Methods: Twenty normal hearts from slaughtered half-bred horses were used. The cardiac weight and circumference were recorded. The atrioventricular valves were expose...
Single-Chamber Cardiac Pacemaker Implantation in a Donkey with Complete AV Block: A Long-Term Follow-Up. A five-month-old African jenny was presented with a history of exercise intolerance and syncopal episodes. Severe bradycardic arrhythmia due to a high-grade second-degree atrioventricular (AV) block with progression to complete AV block was diagnosed. The jenny underwent a transvenous single-chamber pacemaker implantation. The implantation procedure was performed in a lateral recumbency and the ventricular lead was inserted through the jugular vein. Positioning of the lead was guided by echocardiography. The pacemaker was programmed to VVI mode with a minimal ventricular rate of 40 pulses per ...
Heart Rate and Heart Rate Variability of Amateur Show Jumping Horses Competing on Different Levels. Heart rate is one of the gold standards used to assess the workload level and fitness of horses. However, when slight differences need to be detected, it is not sensitive enough. Therefore, the aim of this study was to test the effect of competition level and phase of exercise on the heart rate and heart rate variability parameters in show jumpers. Fourteen horses were examined competing on three different levels: 100 cm (n = 4), 120 cm (n = 6), and 130 cm (n = 4). The length of work (min); average and maximum heart rate; average, maximum and minimum RR intervals (ms); SD1 and SD2 (ms); RMSSD ...
Evaluation of electrocardiographic repolarization parameters after administration of trimethoprim-sulfadiazine, detomidine, or their combination in horses. To determine whether administration of trimethoprim-sulfadiazine (TMS), detomidine (DET), or TMS plus DET would be associated with changes in ECG repolarization parameters in horses. Methods: 9 healthy adult horses. Methods: Each horse received 4 treatments in a blinded, randomized, crossover study design as follows: TMS, 16 to 24 mg/kg, IV; DET, 0.015 to 0.02 mg/kg, IV; TMS plus DET; and saline (0.9% NaCl) solution. Surface ECG traces were obtained over 24 hours, and repolarization parameters were measured at predefined time points after each treatment and compared with a 2-way ANOVA for repe...
Effect of racing on cardiac troponin I concentration and associations with cardiac rhythm disturbances in Standardbred racehorses. Accumulating evidence indicates intense exercise can be associated with myocardial damage. Investigating the impact of maximal effort on myocardium and exploring possible association of injury with rhythm disturbance requires a high-sensitivity cardiac troponin assay. The objectives of this study were: (1) to determine the effect of racing on serum cardiac troponin I (cTnI) in Standardbred horses using a high-sensitivity assay; (2) to determine the 99th percentile of cTnI in healthy horses and investigate the effect of demographic variables on cTnI prevailing pre-race in Standardbred horses us...
Four weeks of high-intensity training in moderate, but not mild hypoxia improves performance and running economy more than normoxic training in horses. We investigated whether horses trained in moderate and mild hypoxia demonstrate greater improvement in performance and aerobic capacity compared to horses trained in normoxia and whether the acquired training effects are maintained after 2 weeks of post-hypoxic training in normoxia. Seven untrained Thoroughbred horses completed 4 weeks (3 sessions/week) of three training protocols, consisting of 2-min cantering at 95% maximal oxygen consumption under two hypoxic conditions (H16, F O = 16%; H18, F O = 18%) and in normoxia (N21, F O = 21%), followed by 2 weeks of post-hypoxic traini...
Morphometric analysis of cardiac conduction fibers in horses and dogs, a comparative histological and immunohistochemical study with findings in human hearts. The principal function of the ventricular conduction system is rapid electrical activation of the ventricles. The aim of this study is to conduct a morphometric study to pinpoint the morphological parameters that define cardiac conduction cells, allowing us to distinguish them from other cells. Five male horse hearts and five male dog hearts were used in the study. The hearts were fixed in a 5% formaldehyde solution. Histological sections of 5 μm thickness were acquired and stained with hematoxylin-eosin and Masson's trichrome and cardiac conduction cells and their junctions were identified ...
Real-time three-dimensional echocardiography for left atrial volume assessment in Thoroughbred racehorses: Observer variability and comparison with two-dimensional echocardiography. Left atrial size predicts cardiac morbidity and mortality in humans and dogs. Real-time three-dimensional echocardiography (3DE) may be reliable for assessing left atrial volume (LAV) in horses. Objective: To determine intra- and interobserver variability estimates of 3DE-LAV and compare it to that of 2DE-LAV estimates. Methods: Method comparison. Methods: 3DE datasets were obtained from 40 horses, then graded for quality, creating a final study population of 22 horses. The 3DE and 2DE maximum LAV (LAV ) and minimum LAV (LAV ) were measured, and left atrial emptying volume (LA EV) and left atr...
Comparison of intraoperative cardiorespiratory and behavioral responses to medetomidine combined with tramadol or butorphanol during standing laparoscopic ovariectomy in horses. The purpose of this study was to assess the cardiorespiratory and behavioral responses to the combination of medetomidine and tramadol (M-T) or butorphanol (M-B) in standing laparoscopic ovariectomy in horses. One ovary was removed under M-T and the contralateral ovary was removed under M-B with at least 4 weeks between operations at random. Horses were sedated using intravenous medetomidine (5 µg/kg) followed by tramadol (1 mg/kg) or butorphanol (10 µg/kg) after 5 min. Sedation was maintained through the repeated injection of medetomidine (1 µg/kg) and tramadol (0.4 mg/kg) or medetomidine ...
Inhibition of Small-Conductance Calcium-Activated Potassium Current (I K,Ca) Leads to Differential Atrial Electrophysiological Effects in a Horse Model of Persistent Atrial Fibrillation. Small-conductance Ca2+-activated K+ (KCa2) channels have been proposed as a possible atrial-selective target to pharmacologically terminate atrial fibrillation (AF) and to maintain sinus rhythm. However, it has been hypothesized that the importance of the KCa2 current-and thereby the efficacy of small-conductance Ca2+-activated K+ current (I K,Ca) inhibition-might be negatively related to AF duration and the extent of AF-induced remodeling. Unassigned: To address the hypothesis of the efficacy of I K,Ca inhibition being dependent on AF duration, the anti-arrhythmic properties of the I K,Ca inh...
Right atrial-related structures in horses of interest during electrophysiological studies. Arrhythmias are common in horses, but catheter-based minimally invasive electrophysiological studies and therapeutic interventions have been poorly explored in equine medicine, partly due to the lack of detailed anatomical knowledge of the equine heart. Objective: To describe the dimensions and anatomical features of some electrophysiologically important landmarks of the right atrium in detail and assess their correlation with bodyweight and aortic diameter. Methods: Ex vivo cadaveric study. Methods: Twenty-one hearts of Warmblood horses, subjected to euthanasia for noncardiovascular reasons, ...
Relationship between atrial fibrillatory rate based on analysis of a modified base-apex surface electrocardiogram analysis and the results of transvenous electrical cardioversion in horses with spontaneous atrial fibrillation. To compare the atrial fibrillatory rate (AFR) derived from a local right atrial intracardiac recording (RA-FR) and from a single-lead surface electrocardiogram (ECG) during atrial fibrillation (AF) and to evaluate the correlation with transvenous electrical cardioversion (TVEC) threshold (in Joules), number of shocks and cardioversion success rate in horses. Methods: ECGs and clinical records of horses with AF treated by TVEC. Horses were included if a simultaneous recording of the right atrial intracardiac electrogram and a modified base-apex ECG were available. Methods: Clinical records of h...
External Loading Characteristics of Polo Ponies and Corresponding Player Heart Rate Responses in 16-Goal Polo. When compared with other equestrian sports, Polo players engage in a high number of player-pony interactions. To ensure optimal performance of the player-pony dyad, an understanding of the workloads performed by each pony and the physiological cost placed on the rider are required. This investigation examined the relationship and interaction between Polo pony performance (speeds attained, distance covered, and movements performed) and the corresponding heart rate responses in Polo players, within and between games across a 16-goal Polo tournament. Descriptive statistics revealed Polo is played...
Atrial fibrillation in horses Part 2: Diagnosis, treatment and prognosis. Atrial fibrillation (AF) is suspected by an irregularly irregular rhythm during auscultation at rest and should be confirmed by electrocardiography. Heart rate monitoring is potentially interesting for AF detection by horse owners, based on the disproportionally high heart rate during exercise or increased heart rate variability. Echocardiography and laboratory analysis are useful to identify underlying cardiac disease. Horses with severe cardiac disease should not undergo cardioversion due to the risk of recurrence. Cardioversion is recommended especially in horses performing high intensity e...
Evaluation of a smartphone-based electrocardiogram device accuracy in field and in hospital conditions in horses. Due to compactness and cheapness, smartphone ECG (sECG) could be very useful to equine practitioners. However, previous studies have evaluated the accuracy of sECG in hospitalised horses only. Different conditions in the field could influence the accuracy of the device. The aim of this study is to compare the accuracy of sECG in field and in hospital conditions. Methods: This is a prospective study. Paired standard base-apex ECG (stECG) and sECG were recorded in hospitalised horses and in subjects examined in field conditions. ECGs were analysed for heart rate and rhythm, presence/type of arrh...
Cardiopulmonary function during supramaximal exercise in hypoxia, normoxia and hyperoxia in Thoroughbred horses. Supramaximal exercise while inspiring different O gases may induce different responses in cardiopulmonary function at the same relative and/or absolute exercise intensity. The purpose of this study was to compare the effects of supramaximal exercise in hypoxia, normoxia and hyperoxia on cardiopulmonary function in Thoroughbred horses. Using a crossover design, five well-trained horses were made to run up a 6% grade on a treadmill at supramaximal speeds sustainable for approximately 110 sec (approximately 115% Omax) while breathing normoxic gas (NO, 21% O) or hypoxic gas (LO, 15.3% O) in random...
Pharmacokinetics and pharmacodynamics of l-methadone in isoflurane-anaesthetized and mechanically ventilated ponies. To evaluate the pharmacokinetics and selected pharmacodynamic effects of a commercially available l-methadone/fenpipramide combination administered to isoflurane anaesthetized ponies. Methods: Prospective single-group interventional study. Methods: A group of six healthy adult research ponies (four mares, two geldings). Methods: Ponies were sedated with intravenous (IV) detomidine (0.02 mg kg) and butorphanol (0.01 mg kg) for an unrelated study. Additional IV detomidine (0.004 mg kg) was administered 85 minutes later, followed by induction of anaesthesia using IV diazepam (0.05 mg kg) and keta...
A novel approach for obtaining 12-lead electrocardiograms in horses. In equine medicine, 12-lead electrocardiograms (ECGs) rarely are used, which may in part be a result of shortcomings in the existing guidelines for obtaining 12-lead ECGs in horses. The guidelines recommend placing the limb leads on the extremities, which is inappropriate because the ventricular mean electrical axis is then perpendicular to the limb leads, leading to large variations in ECG configuration even among healthy horses. From an electrophysiological point of view, the leads instead should be parallel to the electrical axis to minimize variability. Objective: Develop an improved metho...
Heart rate variability analysis in horses for the diagnosis of arrhythmias. Heart rate variability (HRV) analysis has been performed on ECG-derived data sets for more than 170 years but is currently undergoing a rapid evolution, thanks to the expansion of the human and veterinary medical technology sector. Traditional HRV analysis was initially performed to identify changes in vago-sympathetic balance, while the most recent focus has expanded to include the use of complex computer algorithms, neural networks and machine learning technology to identify cardiac arrhythmias, particularly atrial fibrillation (AF). Some of these techniques have recently been translated for...
Quantitative assessment of left ventricular volume and function by transthoracic and transesophageal echocardiography, ultrasound velocity dilution, and gated magnetic resonance imaging in healthy foals. To compare measurements of left ventricular volume and function derived from 2-D transthoracic echocardiography (2DE), transesophageal echocardiography (TEE), and the ultrasound velocity dilution cardiac output method (UDCO) with those derived from cardiac MRI (cMRI) in healthy neonatal foals. Methods: 6 healthy 1-week-old Standardbred foals. Methods: Foals were anesthetized and underwent 2DE, TEE, and cMRI; UDCO was performed simultaneously with 2DE. Images acquired by 2DE included the right parasternal 4-chamber (R4CH), left apical 4- and 2-chamber (biplane), and right parasternal short-axis...
Echocardiographic assessment of left ventricular size and systolic function in Warmblood horses using linear measurements, area-based indices, and volume estimates: A retrospective database analysis. Echocardiographic assessment of left ventricular (LV) size and function using area-based indices and volumetric estimates is not well established in horses. Objective: To report reference intervals and measurement variability for uni-, 2-, and 3-dimensional echocardiographic indices of LV size and systolic function in Warmblood horses and to provide proof of concept for allometric scaling of variables to body weight. Unidimensional indices were to be compared to area-based indices and LV volume estimates to establish their clinical use. Methods: Thirty healthy Warmblood horses and 70 Warmblood...
Prevalence of cardiac arrhythmias and R-R interval variation in healthy Thoroughbred horses during official Chuckwagon races and recovery. The prevalence and severity of cardiac arrhythmias in healthy racehorses undergoing competition is not well defined. The aim was to characterize arrhythmias in Thoroughbreds participating in official Chuckwagon races and to determine normal beat-to-beat (R-R) variability during supramaximal exercise. Electrocardiograph (ECG) recordings were obtained during pre-race, race, and active-recovery from 82 clinically healthy Thoroughbreds. ECG recordings were analyzed for arrhythmias and mean percent R-R deviation. Plasma lactate and high-sensitivity troponin (hs-cTnT) were also measured. Fifty-two E...
Effect of Equine-Assisted Activities on Cardiac Autonomic Function in Children with Cerebral Palsy: A Pilot Randomized-Controlled Trial. Children with cerebral palsy (CP) have an impaired cardiac autonomic function. Attenuated heart rate recovery (HRR), which is a valuable prognostic parameter for autonomic nervous system, is known to be associated with an increased risk of cardiovascular events and all-cause mortality. However, only few studies have observed the effects of exercise on the cardiac autonomic function in children with CP. The purpose of this pilot study was to examine the effects of equine-assisted activity (EAA) program on cardiac autonomic function in children with CP. A single-blinded, parallel, two-arm pilo...
Changes in Arterial Blood Pressure and Oxygen Tension as a Result of Hoisting in Isoflurane Anesthetized Healthy Adult Horses. In anesthetized adult horses, changes in recumbency can influence the cardiovascular system but how arterial blood pressures and oxygen tension change in isoflurane anesthetized animals as a direct result of hoisting has not been investigated. To evaluate effects of hoisting on hemodynamic function and pulmonary gas exchange in isoflurane-anesthetized horses. Prospective, experimental study. Six adult horses were anesthetized three times using isoflurane in pure oxygen (inspired fraction 0.9-1.0), and allowed breathing spontaneously in lateral recumbency. After 45 min horses were hoisted u...
Asymmetric dimethylarginine-A potential cardiac biomarker in horses. Asymmetric dimethylarginine (ADMA) is a cardiac biomarker in humans, symmetric dimethylarginine (SDMA) a renal biomarker in humans, cats, and dogs. The purpose of this prospective study was to investigate if measuring serum ADMA and SDMA concentrations via ELISA allows detection of cardiac disease in horses in a routine laboratory setting. In this context, reference values in horses were established. Methods: Seventy-eight horses with no known medical history were compared to 23 horses with confirmed structural cardiac disease with/or without arrhythmias. Horses underwent physical examination,...
Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance. Limited information is available on paroxysmal atrial fibrillation (PAF) in the horse. Indeed, undiagnosed PAF could result in poor performance. Due to the intermittent occurrence, PAF is difficult to diagnose. However, implanting a small ECG device (implantable loop recorder, ILR) subcutaneously, allows the continuous and automatic detection of PAF. Objective: The aim was to investigate the potential of ILRs as a tool for diagnosing PAF in horses with poor performance. Methods: Prospective field study. Methods: Twelve racing Standardbred trotters with intermittent reduced performance (mean ag...
Cardiac arrhythmias in poorly performing Standardbred and Norwegian-Swedish Coldblooded trotters undergoing high-speed treadmill testing. The significance of cardiac arrhythmias and their possible association with upper airway obstruction are frequently considered in the clinical investigation of poor performance. The specific aims of this retrospective study of a group of poorly performing Standardbred and Norwegian-Swedish Coldblooded trotters were to: (1) describe the overall frequency and frequency distributions of arrhythmias; (2) describe arrhythmia characteristics including percent prematurity, relative recovery cycle lengths and QRS morphology; (3) describe variability of normal RR intervals; and (4) explore possible ass...
ECG Restitution Analysis and Machine Learning to Detect Paroxysmal Atrial Fibrillation: Insight from the Equine Athlete as a Model for Human Athletes. Atrial fibrillation is the most frequent arrhythmia in both equine and human athletes. Currently, this condition is diagnosed via electrocardiogram (ECG) monitoring which lacks sensitivity in about half of cases when it presents in paroxysmal form. We investigated whether the arrhythmogenic substrate present between the episodes of paroxysmal atrial fibrillation (PAF) can be detected using restitution analysis of normal sinus-rhythm ECGs. In this work, ECG recordings were obtained during routine clinical work from control and horses with PAF. The extracted QT, TQ, and RR intervals were used fo...