Electrocardiography (ECG) in horses is a diagnostic tool used to assess the electrical activity of the heart. It involves recording the electrical impulses that govern heartbeats, providing insights into cardiac function and rhythm. This non-invasive method is useful for identifying arrhythmias, conduction disturbances, and other cardiac abnormalities in equine patients. Electrocardiography can be performed at rest or during exercise to evaluate cardiac performance under different physiological conditions. This page compiles peer-reviewed research studies and scholarly articles that explore the methodology, interpretation, and clinical applications of electrocardiography in equine health.
Van Steenkiste G, L V, Decloedt A, Schauvliege S, Boussy T, van Loon G.Understanding the depolarisation pattern of the equine heart under normal physiologic conditions, and its relationship to the surface electrocardiogram (ECG), is of uppermost importance before any further research can be done about the pathophysiology of complex arrhythmias. In the present study, a 3D electro-anatomical mapping system was used to evaluate the qualitative and quantitative depolarisation patterns and correlation to the surface ECG of both the atrial and ventricular endocardium in seven healthy horses in sinus rhythm under general anaesthesia. Bipolar activation maps of the endoc...
Gy C, Leclere M, Bélanger MC, Allano M, Beauchamp G, Lavoie JP.Monensin is highly toxic to horses and inadvertent ingestion can result in cardiac injury and death. Objective: To describe sequelae of monensin ingestion and to determine clinical predictors of outcome. Methods: Observational clinical study. Methods: Physical examination, electrocardiogram and echocardiography were performed on 76 horses accidentally exposed to monensin-contaminated feed. Four horses were examined within 14 days of exposure (acute period), 29 horses were examined between 15 and 45 days post-exposure (subacute period) and 70 horses were examined 4-10 months after exposure ...
Van Steenkiste G, De Clercq D, Boussy T, Vera L, Schauvliege S, Decloedt A, van Loon G.Ultra-high-density cardiac mapping allows very accurate characterisation of atrial and ventricular electrophysiology and activation timing. Objective: To describe the technique and evaluate the feasibility of magnetic electro-anatomical mapping of the equine heart. Methods: In vivo experimental method development. Methods: A mapping system using an 8.5F bidirectional deflectable catheter with a deployable mini-basket (3-22 mm) containing 64 electrodes divided over eight splines was evaluated. Based upon predefined beat acceptance criteria, the system automatically acquires endocardial electro...
Schumacher SA, Toribio RE, Lakritz J, Bertone AL.The objective of this study was to characterize the pharmacokinetics and pharmacodynamics of intravenous administration of magnesium sulfate to horses using a novel radio-telemetry system for physiologic signal capture. Five Horses were surgically implanted with a radio-telemetric carotid catheter. Implants were paired with a non-invasive telemetric unit which acquired a six lead ECG and 3-axis acceleration to assess activity acquired wirelessly in real-time for future analysis. Horses were exposed to a new stall environment before (baseline) and after 60 mg/kg (30 mL) of magnesium sulfate (Mg...
Vernemmen I, De Clercq D, Decloedt A, Vera L, Van Steenkiste G, van Loon G.The number of atrial premature depolarisations (APDs) is a known risk factor for atrial fibrillation (AF) recurrence in humans. Objective: To evaluate if the number of APDs over a 24-h period 5 days post cardioversion predicts AF recurrence within 1 year in horses, taking the multifactorial nature of AF into account. Methods: Retrospective case series. Methods: Eighty horses met these inclusion criteria: first AF episode, no AF recurrence within 5 days post cardioversion, cardioversion by transvenous electrical cardioversion (TVEC), 24-h ECG recording and echocardiographic examination 5 da...
Hesselkilde EZ, Carstensen H, Flethøj M, Fenner M, Kruse DD, Sattler SM, Tfelt-Hansen J, Pehrson S, Braunstein TH, Carlson J, Platonov PG....Large animal models are important in atrial fibrillation (AF) research, as they can be used to study the pathophysiology of AF and new therapeutic approaches. Unlike other animal models, horses spontaneously develop AF and could therefore serve as a bona fide model in AF research. We therefore aimed to study the electrical, functional and structural remodelling caused by chronic AF in a horse model. Nine female horses were included in the study, with six horses tachypaced into self-sustained AF and three that served as a time-matched sham-operated control group. Acceleration in atrial fibrilla...
Peña-Cadahia C, Manso-Díaz G, Santiago-Llorente I, Villalba-Orero M.A 2-day-old filly was referred to the hospital with abdominal pain and constipation. The foal presented tachycardia, tachypnea, hypoxemia, hyperlactatemia, and abdominal distension. Meconium impaction was diagnosed, and the filly underwent abdominal surgery. Diazepam and butorphanol were administered for anesthesia premedication, but sedative effects were mild. Xylazine was used to enhance sedation and ketamine was subsequently administered for induction. The foal showed swallow reflex and head movement when intubation was attempted. Consequently, isoflurane on oxygen was provided via an anest...
Vezzosi T, Vitale V, Sgorbini M, Tognetti R, Bonelli F.Continuous electrocardiography (ECG) monitoring is the gold standard for diagnosing arrhythmias that occur intermittently or under exercise. The aim of this study was to compare two different methods for 24-hour Holter monitoring in horses, a 7-electrode system (7-ES) versus a 4-electrode system (4-ES), assessing the recording performance at rest and during exercise. Six standardbred horses were included in the present prospective study. Two different methods for 24-hour Holter monitoring were used in each horse with a washout period of one week between each recording method. In the first 15 ...
Kraus MS, Rishniw M, Divers TJ, Reef VB, Gelzer AR.Evaluate accuracy and utility of a smartphone-based ECG device compared to a standard base-apex lead ECG in horses. Methods: ECGs were acquired prospectively from 28 client-owned horses at 2 equine referral hospitals. Twenty-five pairs of 30-s ECG recordings were acquired simultaneously from 23 horses with a smartphone ECG device (a bi-polar single lead recorder coupled to a smartphone with an ECG application) and with a standard base-apex lead ECG; 2 horses provided two pairs of simultaneously acquired ECGs. In one horse, the ECGs pairs were recorded immediately sequentially. An additional 7 ...
Mitchell KJ.Analyzing electrocardiographic (ECG) recordings, making a diagnosis and assessment of any arrhythmias present, is an important part of the workup of many equine cases. Accurate analysis requires a good-quality recording, free of as many artifacts as possible, with clear P-QRS-T complex morphology. For sustained arrhythmias, short-term recordings are sufficient to make the appropriate diagnosis before instigating treatment. Longer-term recordings are essential for arrhythmias that are paroxysmal, intermittent, or occurring infrequently, while exercising ECGs are required for arrhythmias associa...
Durando MM.Horses have a high prevalence of resting arrhythmias, cardiac murmurs, and valvular regurgitation, and training can increase the prevalence. This makes it challenging for equine veterinarians who are asked to evaluate horses for poor performance to determine the clinical relevance of some findings. In addition, cardiac disease has the potential to cause collapse or sudden death, putting both the horse and rider at risk. Further diagnostics, such as echocardiograms and resting and exercising ECGs can help to sort out the impact of an abnormality found on resting physical examination. However un...
van Loon G.Arrhythmias are common in horses. Sinus arrhythmia and first- and second-degree atrioventricular block are frequently found physiologic arrhythmias, but should immediately disappear after stress or exercise. Atrial premature depolarizations are usually not associated with poor performance, but are a potential trigger for atrial fibrillation. Atrial fibrillation results in an abnormal ventricular response during exercise and poses a risk for collapse in some horses. This arrhythmia can usually be treated by quinidine sulfate or transvenous electrical cardioversion. Ventricular premature depolar...
Reef VB.Arrhythmias detected on prepurchase examination should be confirmed with an ECG. Exercising ECG determines if the arrhythmia is overdriven during exercise or is a safety concern. An echocardiogram is needed in all horses with a grade 3/6 or louder mid to late systolic, holosystolic, or pansystolic murmur or any holodiastolic decrescendo murmur to identify the cardiac abnormality and its hemodynamic impact. Most horses with arrhythmias and murmurs have a normal performance career and life expectancy and are insurable. Risks for sudden death and congestive heart failure associated with the commo...
Marr CM.Degenerative myxomatous disease is common and is associated with aging. Poor prognostic indicators for equine aortic regurgitation specifically include ventricular ectopy, increased pulse pressure, and hyperkinetic pulses. Valvular prolapse is a functional abnormality diagnosed echocardiographically, about which knowledge is limited. A better understanding of its role in valvular regurgitation is needed. Infective endocarditis presents with fever and other systemic signs accompanying valvular regurgitation. The prognosis is poor, warranting aggressive therapy. Other forms of valvular disease o...
Alexeenko V, Fraser JA, Dolgoborodov A, Bowen M, Huang CL, Marr CM, Jeevaratnam K.The analysis of equine electrocardiographic (ECG) recordings is complicated by the absence of agreed abnormality classification criteria. We explore the applicability of several complexity analysis methods for characterization of non-linear aspects of electrocardiographic recordings. We here show that complexity estimates provided by Lempel-Ziv '76, Titchener's T-complexity and Lempel-Ziv '78 analysis of ECG recordings of healthy Thoroughbred horses are highly dependent on the duration of analysed ECG fragments and the heart rate. The results provide a methodological basis and a feasible refer...
Van Steenkiste G, De Clercq D, Vera L, Decloedt A, van Loon G.Atrial tachycardia including focal atrial tachycardia and macroreentrant atrial tachycardia (atrial flutter), are occasionally found in horses. Diagnosis, treatment and follow-up of these arrhythmias has been inadequately described. Objective: To describe the findings on surface electrocardiography (ECG), intra-atrial electrogram recording and tissue Doppler imaging (TDI), the response to treatment by transvenous electrical cardioversion (TVEC), and TDI follow-up, of sustained atrial tachycardia in horses. Methods: Case series. Methods: Records from horses with sustained atrial tachycardia tre...
Carstensen H, Hesselkilde EZ, Haugaard MM, Flethøj M, Carlson J, Pehrson S, Jespersen T, Platonov PG, Buhl R.The atrial fibrillatory rate is a potential biomarker in the study of antiarrhythmic drug effects on atrial fibrillation (AF). The purpose of this study was to evaluate whether dose-dependent changes in the atrial fibrillatory rate can be monitored on surface electrocardiography (ECG) following treatment with dofetilide, ranolazine, and a combination of the two in an acute model of AF in horses. Eight horses were subjected to pacing-induced AF on 4 separate days. Saline (control), dofetilide, ranolazine, or a combination of dofetilide and ranolazine was administered in four incremental doses. ...
Lorello O, Ramseyer A, Burger D, Gerber V, Navas de Solis C.The objectives of this study were to describe the changes in clinical cardiovascular examination variables over a competition season in groups of competitive eventing and endurance horses and to compare these findings to non-competitive controls of the same breeds. Methods: This study included two eventing horses, 11 endurance horses, and 13 eventing and seven endurance control breed-matched horses. Methods: Cardiovascular examinations were performed before starting the competition season, in the middle and at the peak/end of the competition season. Examinations included auscultation of the he...
Frick L, Schwarzwald CC, Mitchell KJ.Little is known about normal heart rate variability (HRV) in horses during exercise. It can be difficult to separate premature beats from normal beat-to-beat variation at higher heart rates. Objective: The aim was to quantify HRV in healthy horses during a high-speed treadmill-standardized exercise test (HSET) and to compare with the HRV in horses observed to have arrhythmias during exercise. Methods: Thirteen healthy horses (Group H), 30 horses with arrhythmias (Group A), and 11 horses with poor performance but no observed arrhythmias (Group O). Methods: Prospective, observational study. All ...
Nardelli M, Lanata A, Valenza G, Sgorbini M, Baragli P, Scilingo EP.This paper reports on a novel real time index designed to assess the quality of electrocardiographic (ECG) traces recorded in a group of five horses during a submaximal treadmill test procedure. During the experimental protocol two ECG monitoring systems were simultaneously applied to the animals. The first system was equipped with textile electrodes while the second one with standard red-dot electrodes. The procedure comprised four phases with an increased treadmill velocity, specifically, Walk 1, Trot 1, Trot 2 and Gallop. Three signal quality levels have been fixed according to the amount o...
Broux B, De Clercq D, Vera L, Ven S, Deprez P, Decloedt A, van Loon G.Heart rate variability (HRV) parameters, and especially RMSSD (root mean squared successive differences in RR interval), could distinguish atrial fibrillation (AF) from sinus rhythm(SR) in horses, as was demonstrated in a previous study. If heart rate monitors (HRM) automatically calculating RMSSD could also distinguish AF from SR, they would be useful for the monitoring of AF recurrence. The objective of the study was to assess whether RMSSD values obtained from a HRM can differentiate AF from SR in horses. Furthermore, the impact of artifact correction algorithms, integrated in the analyses ...
Zuber N, Zuber M, Schwarzwald CC.Assessment of cardiac electromechanical function in horses requires training, experience and specialised equipment and does not allow continuous monitoring over time. Objective: The objective of this study was to establish the use of an acoustic ECG monitor (Audicor ) in healthy horses. It provides noninvasive, examiner-independent, continuous analyses combining ECG and phonocardiography to calculate indices of cardiac mechanical activity and haemodynamics. Device usability was investigated, reference intervals calculated and reproducibility of analyses assessed. Methods: Prospective descripti...
Piccione G, Giudice E, Giannetto C, Mortola JP.Heart rate (FH) accelerates in inspiration and decelerates in expiration, a phenomenon known as Respiratory Sinus Arrhythmia (RSA). Although the presence of RSA has been documented in many species, how its magnitude compares among species is unknown. We asked whether the magnitude of RSA in a large mammal, the horse, differed from that of previously measured humans. From electrocardiogram and pneumography, the peaks and troughs of FH were identified breath-by-breath in four horses (Italian Saddlebred geldings) during resting wakefulness. RSA was computed as the peak-trough FH difference, in pe...
Chope KB.Cardiac murmurs are not uncommonly detected in the equine athlete. Although most are benign in nature, differentiation and quantification of murmurs due to valvular regurgitation are important for prognosis and recommendations. Arrhythmias can be associated with structural disease or occur independently and may range in severity from minimal clinical effect to poor performance to presenting a safety risk to rider and horse. This article discusses commonly encountered cardiac conditions in the sport horse. Physical examination, diagnostic approach, valvular disease, and arrhythmias with an impa...
Vera L, Decloedt A, Van Steenkiste G, De Clercq D, Govaere J, van Loon G.A 15-year-old Warmblood mare, at 8 months of gestation, was presented to the Ghent University Faculty of Veterinary Medicine for evaluation of suspected stage one labor. Transrectal ultrasonography revealed no clear signs of placentitis or stage one labor. The combined thickness of uterus and placenta was 11 mm and the cervix was closed. Twin pregnancy was suspected by transabdominal ultrasonography but could not be confirmed with certainty. An electrocardiogram (ECG) was recorded from the mare's abdominal wall to register a fetal ECG. To confirm twin pregnancy, registration of both fetal ECG...
Viu J, Armengou L, Decloedt A, Jose-Cunilleras E.Two horses referred to the Unitat Equina, Fundació Hospital Clínic Veterinari, Universitat Autònoma de Barcelona, for unrelated clinical problems, and with no previous history of cardiac disease exhibited an intermittent ventricular pre-excitation electrocardiographic pattern during hospitalization. Both animals showed decreased plasma total and ionized magnesium concentrations, but no other relevant electrolyte disturbances were detected. Altered interventricular septal motion associated with ventricular pre-excitation beats (VPBs) was detected on M-mode echocardiography in both horses. Th...
Li M, Chadda KR, Matthews GDK, Marr CM, Huang CL, Jeevaratnam K.Exercising horses uniquely accommodate 7-8-fold increases in heart rate (HR). The present experiments for the first time analysed the related adaptations in action potential (AP) restitution properties recorded by in vivo telemetric electrocardiography from Thoroughbred horses. The horses were subjected to a period of acceleration from walk to canter. The QRS durations, and QT and TQ intervals yielded AP conduction velocities, AP durations (APDs) and diastolic intervals respectively. From these, indices of active, λ = QT/(QRS duration), and resting, λ0 = TQ/(QRS duration), AP wavelengths wer...
Pinyopummin A, Mahasawangkul S, Nunklang G, Kornkaewrat K, Laopiem S, Koonjaenak S, Wattananit P.The dilution effect and effect of restoring seminal plasma (SP) proportion in diluted semen were determined in chilled Asian elephant sperm. Semen was collected from eight males, and samples with ≥30% motile sperm were used in the study. Tris-glucose-egg yolk extender (TE) was used for cooled storage at 4°C for 48 hr. In experiment 1 (n = 18), semen was diluted to 1:1, 1:3, 1:7 and 1:15 with TE (volume per volume). There were no significant changes in sperm viability and sperm with normal acrosome integrity among dilutions, but sperm motility and motility velocities were greater (p < ....
Gunther-Harrington CT, Arthur R, Estell K, Martinez Lopez B, Sinnott A, Ontiveros E, Varga A, Stern JA.Exercise induced cardiac fatigue (EICF) and cardiac dysrhythmias are well described conditions identified in high-level human athletes that increase in frequency with intensity and duration of exercise. Identification of these conditions requires an understanding of normal pre- and post-race cardiac assessment values. The objectives of this study were to (1) characterize selected indices of cardiac function, electrophysiologic parameters, and biochemical markers of heart dysfunction prior to and immediately after high level racing in Thoroughbred horses receiving furosemide; and (2) create pre...
McGuirk SM, Muir WW.Cardiac arrhythmias are probably more common in horses than in any other domestic animal species. The most frequent clinical complaint associated with cardiac arrhythmias is exercise intolerance. Physical examination is characterized by auscultation abnormalities such as fast or slow heart rate, irregular rhythm, extra sounds, long pauses, or abnormal heart sounds. The electrocardiogram is used to make a definitive diagnosis of the dysrhythmia. Other laboratory and cardiac function tests are employed to determine the etiology and to assess the significance of the arrhythmia. Antiarrhythmic the...
Ayala I, Gutierrez-Panizo C, Benedito JL, Prieto F, Montes A.The aim of this work was to record the modifications of the form and amplitude of the electrocardiographic tracings during growth using the Dubois system and to study its sensibility to these physiological changes. This work was carried out on 179 healthy, young and adult Spanish-bred horses (98 females and 81 males). One electrocardiogram (ECG) was obtained from each horse using the Dubois leads system. The bifid shape deflection of the P wave was generally more frequent than the simple one in animals at 4 months of age or older. Amplitudes of the P2 component and of the simple positive wave ...
Trachsel DS, Bitschnau C, Waldern N, Weishaupt MA, Schwarzwald CC.Frequent supraventricular or ventricular arrhythmias during and after exercise are considered pathological in horses. Prevalence of arrhythmias seen in apparently healthy horses is still a matter of debate and may depend on breed, athletic condition and exercise intensity. Objective: To determine intra- and interobserver agreement for detection of arrhythmias at rest, during and after exercise using a telemetric electrocardiography device. Methods: The electrocardiogram (ECG) recordings of 10 healthy Warmblood horses (5 of which had an intracardiac catheter in place) undergoing a standardised ...
Welch-Huston B, Durward-Akhurst S, Norton E, Ellingson L, Rendahl A, McCue M.Cardiac arrhythmias are commonly auscultated during routine physical examinations in horses and determining the underlying electrical abnormality using an ECG is important. The most commonly used device is a three-lead base apex system (Televet), however few practitioners carry this for routine visits. With recognition of the utility of smartphone-based ECGs in humans, dogs and ruminants, the AliveCor single-lead bipolar smartphone-based ECG has gained popularity. The objective of this study was to determine if AliveCor and Televet ECG measurements were comparable in healthy horses using multi...
Meyer GA, Lin HC, Hanson RR, Hayes TL.This study aimed to identify blood serum lidocaine concentrations in the horse which resulted in clinical signs of intoxication, and to document the effects of toxic levels on the cardiovascular and cardiopulmonary systems. Nineteen clinically normal mature horses of mixed breed, age and sex were observed. Lidocaine administration was initiated in each subject with an i.v. loading dose of 1.5 mg/kg bwt and followed by continuous infusion of 0.3 mg/kg bwt/min until clinical signs of intoxication were observed. Intoxication was defined as the development of skeletal muscle tremors. Prior to admi...
Holmes JR, Alps BJ.Theoretical consideration has been given in two horses to the properties of the electric field created by the equine heart acting as a simple electric generator. The principles of the vectorial theory have been applied to test the validity of application of the dipole concept. The cardiac electric forces, althrough complex in the immediate region of the heart, appear at the body surface in a similar form to those arising from a relatively immobile, single equivalent dipole. The potential value of the technique of vectorcardiography in cardiological investigations is briefly discussed.
Nostell K, Bröjer J, Höglund K, Edner A, Häggström J.The aim of this study was to determine whether experimentally-induced endotoxaemia induced elevations in plasma cardiac troponin I (cTnI) concentrations in horses and how this might affect the incidence of cardiac arrhythmias. Eight Standardbred horses received an intravenous continuous rate infusion of endotoxin (total dose 500 ng/kg) for 6 h while being monitored using electrocardiography (ECG). Blood samples were collected before the start of the endotoxin infusion, every 60 min during the infusion, then 1, 2, 3, 8, 10 and 24 h post-infusion, and analysed for cTnI concentrations. One horse ...
There are several bioengineering solutions aimed at improving human health and welfare. Smart electrodes based on textile substrates have met the growing demand for comfort, reliability, and robustness when acquiring physiological signals. Objective: Given the importance of good quality electrocardiograms (ECG) in equine sports medicine, this study focuses on the validation of smart textile electrodes to acquire ECG signals in horses during treadmill exercise. Methods: The performance of the smart textile electrodes is compared with standard silver/silver chloride (Ag/AgCl) electrodes in terms...
Hilwig RW.Electrocardiograms were obtained from normal horses and from horses with cardiac or other organic disease that affected the cardiac rhythm. Tracings were obtained from a base-apex bipolar monitor lead, with the negative electrode attached to the skin in the right jugular furrow and the positive electrode attached to the skin on the ventral medline, beneath the apex of the heart. Each arrhythmia was discussed relative to importance and probable cause.
The effects of cryopreservation on the acrosomal status of equine spermatozoa were investigated. Ejaculates (n=10) from six stallions were processed fresh, after cooled storage at 4-6 degrees C for 24 h in either a milk-based or lactose-EDTA freezing extender and after freeze-thawing in lactose-EDTA extender in liquid nitrogen at either 5 x 10(7) or 2 x 10(8) spermatozoa ml(-1). All samples were incubated in TALP-TEST for 2 h at 39 degrees C in 5% CO2. Subsamples were challenged with calcium ionophore A23187 for 10 min. The acrosomal status of the spermatozoa was evaluated by staining the sper...
Escudero A, González JR, Benedito JL, Prieto FR, Ayala I.Limited information exists regarding electrocardiographic parameters in clinically healthy donkeys. The study was carried out in 75 healthy adult animals (40 females and 35 males) using the Einthoven standard II and base-apex leads. The P wave showed usually a bifid shape deflection. The QRS complex of the donkeys appeared in several forms: QR and R were the most frequent in limb lead II, and QS and QR in the base-apex lead. Most T waves presented a simple negative configuration in lead II and biphasic shape in the base-apex one. Mean heart rate value was 52 beats per minute. The direction of ...
Evans DL, Rose RJ.The measurement of heart rate during exercise in the horse has been recommended as a means of prescribing work effort, monitoring the changes in aerobic capacity during training and as part of the clinical examination of the performance horse. The accuracy of four heart rate meters (PEH 100, PU 10, HR 14 and HRM-7) was assessed by comparison with heart rate determined by simultaneous telemetry electrocardiography (ECG) using a rapid incremental exercise test on a treadmill. Heart rate displayed by all four meters showed significant correlations with the ECG heart rate, but only two meters (PEH...
Morgan RA, Raftery AG, Cripps P, Senior JM, McGowan CM.The prevalence and nature of arrhythmias in horses following general anaesthesia and surgery is poorly documented. It has been proposed that horses undergoing emergency surgery for gastrointestinal disorders may be at particular risk of developing arrhythmias. Our primary objective was to determine the prevalence and nature of arrhythmias in horses following anaesthesia in a clinical setting and to establish if there was a difference in the prevalence of arrhythmias between horses with and without gastrointestinal disease undergoing surgery. Our secondary objective was to assess selected avail...
Decloedt A, Van Steenkiste G, Vera L, Buhl R, van Loon G.Atrial fibrillation (AF) is suspected by an irregularly irregular rhythm during auscultation at rest and should be confirmed by electrocardiography. Heart rate monitoring is potentially interesting for AF detection by horse owners, based on the disproportionally high heart rate during exercise or increased heart rate variability. Echocardiography and laboratory analysis are useful to identify underlying cardiac disease. Horses with severe cardiac disease should not undergo cardioversion due to the risk of recurrence. Cardioversion is recommended especially in horses performing high intensity e...
Durando MM.Horses have a high prevalence of resting arrhythmias, cardiac murmurs, and valvular regurgitation, and training can increase the prevalence. This makes it challenging for equine veterinarians who are asked to evaluate horses for poor performance to determine the clinical relevance of some findings. In addition, cardiac disease has the potential to cause collapse or sudden death, putting both the horse and rider at risk. Further diagnostics, such as echocardiograms and resting and exercising ECGs can help to sort out the impact of an abnormality found on resting physical examination. However un...
Gelzer AR, Moïse NS, Vaidya D, Wagner KA, Jalife J.Atrial fibrillation (AF) is common in healthy horses. We studied the temporal organization of AF to test the hypothesis that the arrhythmia is governed by a high degree of periodicity and therefore is not random in the horse. Further, we surmised that concealed conduction of AF impulses in the AV node results in an inverse relationship between AF frequency and ventricular frequency. Results: Fast Fourier transform (FFT) analysis of atrial activity was done on signal-averaged ECGs (n = 11) and atrial electrograms (n = 3) of horses with AF at control (C), after quinidine sulfate (22 mg/kg by mou...
Reef VB, Clark ES, Oliver JA, Donawick WJ.A permanent, transvenous, atrioventricular, sequential pacing system was implanted successfully in a 7-year-old Quarter Horse gelding with complete heart block. The transvenous atrial and ventricular electrodes were placed in their respective positions in the heart, using real-time, 2-dimensional echocardiography. The horse was able to return successfully to competition as a show horse.
Buntenkötter S, Deegen E.Cardioversion through varying quinidine sulphate treatments was achieved in 3 riding horses with auricular fibrillation. The horses were subjected to continual telemetric ECG registration before and after reversion in a uniform exercise-tolerance-test. A comparison of the heart rate curves showed a strong decline of the heart beat frequency during the exercise phase after synchronisation. The decrease in heart rate during exercise was greater than 30% in all 3 patients. Anti-arrhythmic treatment is, therefore, recommended for horses with auricular fibrillation and without concurrent heart dise...
Lombard CW, Evans M, Martin L, Tehrani J.Twelve newborn pony foals underwent cardiovascular examinations (auscultation, arterial blood pressure measurements, electrocardiograms and M-mode echocardiograms) on their first day of life and then on Days 7, 14, 21, 30, 60 and 90. An age dependent, statistically significant, rapid increase of the arterial blood pressure in the first month was documented together with a slower decrease of the resting heart rate after two and three months of life. Innocent soft systolic murmurs were audible over the left heart base in a large number of the foals. The electrocardiograms showed age dependent in...
Bayly WM, Reed SM, Leathers CW, Brown CM, Traub JL, Paradis MR, Palmer GH.Five Arabian or half-Arabian foals with suspected multiple cardiac anomalies were examined. Various combinations of clinical examination, electrocardiography, angiocardiography, cardiac catheterization, blood gas analysis, radiography, and echocardiography resulted in clinical data that allowed accurate antemortem diagnoses to be made. In 4 cases, the clinical diagnosis was substantiated by postmortem findings. The confirmed diagnoses were: pseudotruncus arteriosus, a combination of patent ductus arteriosus, pulmonic stenosis, and tricuspid stenosis, pentalogy of Fallot, and tricuspid atresia....
Norman SE, Eager RA, Waran NK, Jeffery L, Schroter RC, Marlin DJ.Analysis of heart rate variability (HRV) is a non-invasive technique useful for investigating autonomic function in both humans and animals. It has been used for research into both behaviour and physiology. Commercial systems for human HRV analysis are expensive and may not have sufficient flexibility for appropriate analysis in animals. Some heart rate monitors have the facility to provide inter-beat interval (IBI), but verification following collection is not possible as only IBIs are recorded, and not the raw electrocardiogram (ECG) signal. Computer-based data acquisition and analysis syste...
Lorello O, Ramseyer A, Burger D, Gerber V, Navas de Solis C.The objectives of this study were to describe the changes in clinical cardiovascular examination variables over a competition season in groups of competitive eventing and endurance horses and to compare these findings to non-competitive controls of the same breeds. Methods: This study included two eventing horses, 11 endurance horses, and 13 eventing and seven endurance control breed-matched horses. Methods: Cardiovascular examinations were performed before starting the competition season, in the middle and at the peak/end of the competition season. Examinations included auscultation of the he...
Squires EL, McCue PM.Embryo recovery from single ovulating mares is approximately 50 per cent per estrous cycle. Superovulation could be used to increase embryo recovery and provide extra embryos for embryo freezing. This review addresses some historical approaches to superovulation, as well as examines factors that affect the response of mares to equine FSH. eCG, GnRH and inhibin vaccines have been of limited success in stimulating multiple ovulation. Numerous studies have shown that injection of equine pituitary extract (EPE) will result in three to four ovulations per estrous cycle and two embryos. A purified, ...
Kraus MS, Rishniw M, Divers TJ, Reef VB, Gelzer AR.Evaluate accuracy and utility of a smartphone-based ECG device compared to a standard base-apex lead ECG in horses. Methods: ECGs were acquired prospectively from 28 client-owned horses at 2 equine referral hospitals. Twenty-five pairs of 30-s ECG recordings were acquired simultaneously from 23 horses with a smartphone ECG device (a bi-polar single lead recorder coupled to a smartphone with an ECG application) and with a standard base-apex lead ECG; 2 horses provided two pairs of simultaneously acquired ECGs. In one horse, the ECGs pairs were recorded immediately sequentially. An additional 7 ...
Robertson JT, Muir WW, Sams R.The cardiopulmonary and behavioral effects of butorphanol were evaluated in pain-free adult horses. Butorphanol tartrate was administered IV in doses of 0.1, 0.2, and 0.4 mg/kg to the same horses on 3 separate occasions. There were no significant (P less than 0.05) changes in heart rate, mean and diastolic arterial pressure, mean and diastolic pulmonary arterial blood pressure, or cardiac output recorded in the horses given these doses. Systolic arterial blood pressure was significantly (P less than 0.05) increased in only the horses given the 0.2 mg/kg dose. Significant (P greater than 0.05) ...
Pérez-Marín CC, Requena FD, Arando A, Ortiz-Villalón S, Requena F, Agüera EI.There has been a lack of research into equine sperm vitrification to date, but studies of other species suggest it may have significant potential. To evaluate the impact of various cryoprotectant agents (CPA) and vitrification on equine sperm quality, a controlled study was carried out. A total of 12 ejaculates were subjected to exposure to CPA and vitrification. Sperm was diluted in a range of CPA: fresh, control (BSA), sucrose (0.15M, 0.3M and 0.5M), trehalose (0.15M, 0.3M and 0.5M) and the combination of sucrose and trehalose (M1: 0.15M sucrose+0.5M trehalose; M2: 0.5M sucrose+0.15M trehalo...
Frye MA, Selders CG, Mama KR, Wagner AE, Bright JM.Rectilinear biphasic cardioversion was used in 2 horses with idiopathic sustained atrial fibrillation; 1 horse converted to sustained sinus rhythm. Variables that potentially affected outcome of the electrical cardioversion procedures in these horses included duration of arrhythmia, placement of cardioverter pads and paddles, serum electrolyte concentrations, and treatment with quinidine. Serum cardiac troponin I concentration, measured to determine whether the myocardium was damaged from the electrical shocks, was within the reference range in both horses after the procedure. Biphasic electri...