Analyze Diet

Topic:Horseshoes

Horseshoes are protective devices attached to the hooves of horses to enhance durability and performance. They are typically made from materials such as steel, aluminum, or composite materials and are designed to protect the hoof from wear and tear, provide traction, and support for various equine activities. The application of horseshoes, known as shoeing, is performed by a farrier and involves careful consideration of the horse's hoof anatomy, activity level, and environmental conditions. Horseshoes can be customized to address specific hoof health issues or performance needs. This page compiles peer-reviewed research studies and scholarly articles that explore the design, application, and impact of horseshoes on equine biomechanics, hoof health, and performance.
Biomechanical analysis of horse shoeing.
Equine veterinary journal. Supplement    February 5, 2000   Issue 30 629-630 doi: 10.1111/j.2042-3306.1999.tb05298.x
Aoki O.Most of the principles of farriery have been derived from practical experience and traditional skills of individual farriers. To date, there has been little done in the way of good science and few publications have appeared to advance the discipline. Therefore, opinions or policies on horse shoeing vary greatly between farriers and members of the veterinary profession. The aim of this workshop was to present the latest information on biomechanical analysis of horse shoeing as it relates to modern day farriery and could have direct benefits for the future of shoeing in performance horses.
The effect of shoeing on kinetics and kinematics during the stance phase.
Equine veterinary journal. Supplement    February 5, 2000   Issue 30 279-285 doi: 10.1111/j.2042-3306.1999.tb05235.x
Roepstorff L, Johnston C, Drevemo S.The increasing range of of horseshoes and hoofpads makes it important to be able to evaluate their influence on performance and stress in the locomotor apparatus. The aim of this study was to describe the changes in ground reaction forces and locomotion pattern during the stance phase due to the application of a standard iron shoe. Six Swedish Warmblood horses were evaluated kinetically and kinematically before and after they were shod with an 8 mm iron shoe. Data were used to calculate ground reaction forces in the vertical and craniocaudal directions, point of application of the force, hoof ...
In vitro transmission and attenuation of impact vibrations in the distal forelimb.
Equine veterinary journal. Supplement    February 5, 2000   Issue 30 245-248 doi: 10.1111/j.2042-3306.1999.tb05227.x
Willemen MA, Jacobs MW, Schamhardt HC.An in vitro model was developed and validated in vivo to quantify the attenuation of impact vibrations, transmitted through the lower equine forelimb and to assess the effects of horseshoeing on this attenuation. The transsected forelimbs of 13 horses were equipped with custom-made hollow bone screws in the 4 distal bones, on each of which a tri-axial accelerometer could be mounted. The limbs were then preloaded while the impact was simulated by dropping a weight on the steel plate on which the hoof was resting. At the hoof wall, the distal, middle and proximal phalanx and at the metacarpal bo...
[Navicular disease in the hind limb of a Warmblood horse].
Tijdschrift voor diergeneeskunde    October 16, 1999   Volume 124, Issue 18 536-538 
Meijer MC, Rijkenhuizen AB.A 12-year-old Dutch Warmblood mare was admitted to the clinic with a 1-month history of lameness of the left hind leg. After clinical and radiological examinations and an bursascopy, the diagnosis navicular disease was made. The therapy consisted of stallrest, non-steroidal anti-inflammatory drugs, and orthopaedic shoeing plus intrabursal injections of short-acting corticosteroids and hyaluronic acid. The therapy was repeated following recurrence of the lameness. According to the owner the horse is currently performing at its previous level.
Trimming and shoeing the chronically affected horse.
The Veterinary clinics of North America. Equine practice    September 3, 1999   Volume 15, Issue 2 463-480 doi: 10.1016/s0749-0739(17)30155-4
Curtis S, Ferguson DW, Luikart R, Ovnicek G.Several of the technical approaches applied to the foot overlap with regard to intent. Frog or solar support, for example, may be provided either to stabilize the distal phalanx within the hoof capsule or in an effort to unload regional pain arising from the solar surface of the foot. It is likewise obvious that some techniques such as lowering the heels to achieve phalangeal realignment and raising the heels to relieve deep digital flexor tendon tension are contradictory. In these instances, it is not that one technique is always correct but that differences exist among horses. Currently, it ...
[Use of tempered, particle-reinforced aluminum horse shoes in sport horses under field conditions].
DTW. Deutsche tierarztliche Wochenschrift    March 23, 1999   Volume 106, Issue 2 55-60 
Brandstetter J, Stanek C, Hinterhofer C.The use of handmade particulate reinforced alloy horseshoes (MMC metal matrix composites) was tested in a field study on 15 riding and draught horses. All horseshoes have been tempered after having been manually forged and tested concerning their surface imperfection. Forging temperature ranged between 350 degrees and 420 degrees C. Horseshoes in series A consisted of particulate reinforced wrought alloy (22% Al2O3 in alloy matrix). 11 shoeing periods with a duration of mean = 49.7 days (sd = 13.6) were evaluated. Horseshoes in series B consisted of particulate reinforced foundry alloy (20% Si...
The effect of orthopaedic shoeing on the force exerted by the deep digital flexor tendon on the navicular bone in horses.
Equine veterinary journal    February 10, 1999   Volume 31, Issue 1 25-30 doi: 10.1111/j.2042-3306.1999.tb03787.x
Willemen MA, Savelberg HH, Barneveld A.This study quantifies both the intended effect of orthopaedic shoeing to decrease the load on the navicular bone and the eventual undesired effects on gait performance. The compressive force exerted by the deep digital flexor tendon on the navicular bone and on the quality of the trot and redistribution of forces over the flexor tendons and the suspensory ligament were studied as a function of orthopaedic shoeing in 12 sound Dutch Warmblood horses. A modified CODA-3 gait analysis system and a force plate were used to quantify objectively the load on the lower limb. The quality of the trot was ...
Variation in surface strain on the equine hoof wall at the midstep with shoeing, gait, substrate, direction of travel, and hoof shape.
Equine veterinary journal. Supplement    February 5, 1999   Issue 26 86-95 doi: 10.1111/j.2042-3306.1998.tb05126.x
Thomason JJ.Objectives were to examine the deformation of the healthy equine front hoof during locomotion, by recording strains on its outer surface, and to test whether its mechanical behaviour is significantly altered under different locomotory conditions and variation in hoof shape. Strains were recorded in vivo from 5 rosette gauges around the circumference of the right forehooves of 12 horses. The magnitudes and orientations of principal strains at the midstep were compared statistically for different conditions of shoeing (shod vs. unshod), gait (walk vs. trot), substrate (treadmill vs. ground), and...
Digital perfusion, evaluated scintigraphically, and hoof wall growth in horses with chronic laminitis treated with egg bar-heart bar shoeing and coronary grooving.
Equine veterinary journal. Supplement    February 5, 1999   Issue 26 111-118 doi: 10.1111/j.2042-3306.1998.tb05129.x
Ritmeester AM, Blevins WE, Ferguson DW, Adams SB.Nuclear scintigraphy was used to assess digital perfusion before and after treatment in 10 horses with clinical and radiographic evidence of chronic laminitis. Horses were evaluated for lameness, degree of distal phalanx rotation, and heel-toe hoof wall growth ratio, and randomly divided into two treatment groups. Group 1 horses received only egg bar-heart bar shoeing; Group 2 underwent egg bar-heart bar shoeing and coronary grooving. Horses were re-evaluated for digital perfusion, lameness, degree of distal phalanx rotation, and hoof wall growth at 6 week intervals over the 18 week follow-up ...
[The bringing of the latest technology to the evolution of horse shoeing, from its origin to our time].
Schweizer Archiv fur Tierheilkunde    February 3, 1999   Volume 141, Issue 1 3-9 
Chuit P.No abstract available
In-shoe foot force sensor to assess hoof balance determined by radiographic method in ponies trotting on a treadmill.
The veterinary quarterly    November 12, 1998   Volume 20, Issue 4 131-135 doi: 10.1080/01652176.1998.9694857
Caudron I, Grulke S, Farnir F, Vanschepdael P, Serteyn D.Adaptation of an in-foot shoe force sensor and the gait analysis system 'Fscan' makes it possible to monitor the distribution of the vertical forces under the equine foot in motion. The aim of this study is to investigate the effects of two different trimmings on forces under the foot during the trot. The first one increased the height of the lateral hoof wall and the second one restored the mediolateral balance of the foot. These two trimmings were examined by using a radiographical method that quantifies the interphalangeal articular asymmetries due to asymmetrical bearing. The location of t...
[The biomechanical effects of hoof load-bearing].
Tijdschrift voor diergeneeskunde    July 25, 1998   Volume 123, Issue 13 408-410 
Willemen MA.No abstract available
Use of the bit in horses.
The Veterinary record    April 9, 1998   Volume 142, Issue 8 200 
Cook WR.No abstract available
Radiological assessment of the effects of a full rolling motion shoe during asymmetrical bearing.
Equine veterinary journal. Supplement    May 1, 1997   Issue 23 20-22 doi: 10.1111/j.2042-3306.1997.tb05045.x
Caudron I, Miesen M, Grulke S, Vanschepdael P, Leroy P, Serteyn D.The authors used a new radiological method to assess asymmetrical articular compression of the interphalangeal joints. This method was based on the measurements of 3 angles obtained on dorsopalmar radiographs. Variations of these angles were studied during experimental asymmetrical bearing on unshod feet. It was concluded that 2 angles were interesting parameters to assess asymmetrical articular compression and to define the position of the phalanx in the horny box. Furthermore, variations of these angles induced by experimental asymmetrical bearing were compared without shoe, with a standard ...
Horseshoe characteristics as possible risk factors for fatal musculoskeletal injury of thoroughbred racehorses.
American journal of veterinary research    August 1, 1996   Volume 57, Issue 8 1147-1152 
Kane AJ, Stover SM, Gardner IA, Case JT, Johnson BJ, Read DH, Ardans AA.To evaluate selected shoe characteristics as risk factors for fatal musculoskeletal injury (FMI) and specifically for suspensory apparatus failure (SAF) and cannon bone condylar fracture (CDY) of Thoroughbred racehorses in California. Methods: Case-control study. Methods: Thoroughbred racehorses (n = 201) that died of were euthanatized at California racetracks between August 1992 and July 1994. Methods: Shoe characteristics were compared between case horses affected by FMI (155), SAF (79), and CDY (41) and control horses that died for reasons unrelated to the appendicular musculoskeletal syste...
Postmortem evaluation of homotypic variation in shoe characteristics of 201 thoroughbred racehorses.
American journal of veterinary research    August 1, 1996   Volume 57, Issue 8 1141-1146 
Kane AJ, Stover SM, Gardner IA, Case JT, Johnson BJ, O'Brien MJ, Read DH, Ardans AA.To develop a standard technique for evaluation of racehorse shoes, to assess homotypic variation (interlimb variation) in shoe characteristics, and to determine whether shoe characteristics varied with age and sex. Methods: Cross-sectional study. Methods: Thoroughbred racehorses (n = 201) that died or were euthanatized at California racetracks between August 1992 and July 1994. Methods: Shoe characteristics were measured on horses examined after death. Percentage of agreement was used to compare shoe characteristics between limbs (homotypic variation). Using chi 2 analysis, shoe characteristic...
Influence of shoeing on ground reaction forces and tendon strains in the forelimbs of ponies.
Equine veterinary journal    March 1, 1996   Volume 28, Issue 2 126-132 doi: 10.1111/j.2042-3306.1996.tb01604.x
Riemersma DJ, van den Bogert AJ, Jansen MO, Schamhardt HC.Strains in the superficial digital flexor tendon (SDFT), deep digital flexor tendon (DDFT), accessory ligament of the deep digital flexor muscle (inferior check ligament [ICL]) and the interosseus medius muscle (suspensory ligament [SL]) in the right forelimb of 5 ponies were measured using mercury-in-silastic strain gauges a few hours after implantation. Tendon strains were recorded at the walk with normal flat shoes, egg-bar shoes, a 7 degrees increased hoof angle accomplished by application of a heel-wedge and a 7 degrees decreased hoof angle using a toe-wedge, consecutively. Ground reactio...
Equine hoof hardener.
The Veterinary record    October 22, 1994   Volume 135, Issue 17 415-416 doi: 10.1136/vr.135.17.415-b
Reeves C.No abstract available
Equine hoof function investigated by pressure transducers inside the hoof and accelerometers mounted on the first phalanx.
Equine veterinary journal    September 1, 1994   Volume 26, Issue 5 362-366 doi: 10.1111/j.2042-3306.1994.tb04404.x
Dyhre-Poulsen P, Smedegaard HH, Roed J, Korsgaard E.The dampening of hoof impact was investigated by measuring the accelerations transmitted through structures of the hoof in horses trotting freely on an asphalt tarmac. The hoof dampened the vibrations transmitted to the first phalanx. Shoeing decreased the viscous dampening and increased the median power frequency and the maximal amplitude of the vibrations transmitted to the first phalanx. The pressure inside the digital cushion of the foreleg was recorded. The pressure dropped during the stance phase, indicating expansion of the hoof. The expansion of the hoof was not produced by frog or sol...
The effect of toe weights on linear and temporal stride characteristics of standardbred trotters.
The veterinary quarterly    May 1, 1994   Volume 16 Suppl 2 S97-S100 
Willemen MA, Savelberg HH, Bruin G, Barneveld A.Toe weights are applied to influence the stride characteristics of trotters. The quantitative effect of 88-g toe weights on the stride characteristics of Standardbred trotters was evaluated in a kinematic study using a CODA-3 analysis system. Six trotters were studied at a speed of 11 m/s on a treadmill. Temporal gait variables, joint angles, and the trajectories of the forelimb hoof were calculated. The stride patterns of the individual trotters were assessed by a judge and compared to the CODA-output. Those trotters with poor flexion of the carpal joint during the swing phase or with insuffi...
[A discovery of horseshoes from the 17th century in Kiesen in Bern canton].
Schweizer Archiv fur Tierheilkunde    January 1, 1994   Volume 136, Issue 1 9-14 
Imhof U.The discovery of all four horseshoes in connection with the horse-skeleton (see IMHOF: "Discovery of a skeleton of the 17th century in Kiesen/Switzerland") made it possible to determinate its age by the radiocarbon method indirectly. The horseshoes are fully documented with pictures and scales and the findings described and discussed in detail.
Comparison of the damping effect of different shoeing by the measurement of hoof acceleration.
Acta anatomica    January 1, 1993   Volume 146, Issue 2-3 109-113 doi: 10.1159/000147430
Benoit P, Barrey E, Regnault JC, Brochet JL.The purpose of this study was to compare the damping effect of 16 types of shoeing by measuring hoof acceleration parameters on two trotting horses. At impact, maximal deceleration had extreme values such as 188 m/s2 (+/- 55) for the most damping combination (p < 0.01) and 746 m/s2 (+/- 14) for the steel shoe (mean = 551 m/s2 +/- 125). After the shock, the hoof was exposed to a mean vibrating acceleration at 418 Hz (+/- 84) which was progressively damped in 37.3 ms (+/- 10.5). According to these results, the damping ability of different farriery products significantly reduces (p < 0.05) shocks...
Concept of a force-measuring horseshoe.
Acta anatomica    January 1, 1993   Volume 146, Issue 2-3 114-119 doi: 10.1159/000147431
Roepstorff L, Drevemo S.To further develop objective methods in the field of gait analysis a force-measuring horseshoe (FM shoe) has been developed. The ground reaction forces were determined by measuring the degree of displacement between the two solid parts of the shoe. This was done by three removable measuring units (MUs) that were equipped with strain gauges and placed in the toe and in each of the quarter parts. Before performing force recordings the sensors were calibrated with the actual MUs mounted on the shoe. This can be done in the field with a specially developed equipment. The shape of the signal genera...
Firing of horses.
The Veterinary record    August 29, 1992   Volume 131, Issue 9 202 doi: 10.1136/vr.131.9.202
Frank C.No abstract available
The construction of the heart bar shoe and the technique of dorsal wall resection.
Equine veterinary journal    September 1, 1989   Volume 21, Issue 5 367-369 doi: 10.1111/j.2042-3306.1989.tb02692.x
Eustace RA, Caldwell MN.This paper describes a method of fabricating and fitting heart bar shoes and a technique of dorsal hoof wall resection. The rationale behind the treatments and criteria for their use are described. Radiographic technique is also discussed. This article reports the treatment of a series of clinical cases described in an accompanying article (p370).
The relationship of frog pressure to heel expansion.
Equine veterinary journal    January 1, 1989   Volume 21, Issue 1 13-16 doi: 10.1111/j.2042-3306.1989.tb02082.x
Colles CM.A study was carried out on five horses and four ponies to assess the effect of altering frog pressure on hoof expansion. Measurements of hoof expansion were made using strain gauges. It was concluded that whereas frog pressure affects hoof expansion, it is only one of several factors. Increasing frog pressure may result in increased expansion, or contraction, or may have virtually no affect. The variable results of changing frog pressure should be taken into account when considering therapeutic shoeing.
A technique for assessing hoof function in the horse.
Equine veterinary journal    January 1, 1989   Volume 21, Issue 1 17-22 doi: 10.1111/j.2042-3306.1989.tb02083.x
Colles CM.This paper describes the application of foil strain gauges to the hoof wall, and the use of measuring equipment to monitor weightbearing and changes in hoof shape in shod and unshod horses. It concludes that the systems can detect hoof movement and that results are reproducible. It is also concluded that the use of a conventional nailed on iron shoe restricts flexion and spreading of the hoof wall at the ground surface, but has little effect on the degree of expansion of the heels of the foot.
Review of pathogenesis and treatment of degenerative joint disease.
Equine veterinary journal. Supplement    September 1, 1988   Issue 6 3-11 doi: 10.1111/j.2042-3306.1988.tb04641.x
McIlwraith CW, Vachon A.Treatment of degenerative joint disease (osteoarthritis) is discussed in relationship to pathogenesis of five clinical entities, defined to facilitate discussion:-1) occurring in high motion joints and associated with synovitis; 2) associated with low motion joints; 3) "non-progressive" articular cartilage erosion; 4) secondary to other identified problems (intra-articular fractures, ligamentous damage, wounds, septic arthritis, osteochondrosis); and 5) chondromalacia of the patella. In addition to direct damage to articular cartilage, synovitis and capsulitis and depletion of matrical glycosa...
The pathogenesis and treatment of osteomyelitis and laminitis in a stallion after the prolonged topical application of formalin to the distal phalanx.
Australian veterinary journal    June 1, 1988   Volume 65, Issue 6 185-188 doi: 10.1111/j.1751-0813.1988.tb14297.x
Dart AJ, Pascoe RR.A 12-year-old Quarterhorse stallion was presented with a severe lameness in the left forefoot. There was a 3 cm diameter cavity in the sole that extended to the solar surface of the distal phalanx. Radiographs revealed an osteomyelitis and a sequestrum which probably developed following the prolonged topical application of 10 percent formalin. The sequestrum was removed and the infected bone curetted under general anaesthesia. The horse was shod with heart bar shoes on both front feet 7 days after the surgery. Eight months later, radiographs showed marked rotation of the distal phalanx despite...
Measurements of bone strain in foals with altered foot balance.
American journal of veterinary research    February 1, 1988   Volume 49, Issue 2 261-265 
Firth EC, Schamhardt HC, Hartman W.Two to 7 days after birth, 9 foals were anesthetized, and strain gauges were applied to lateral and medial aspects of the third metacarpal bone of the left forelimb. In 5 of these foals, strain gauges also were applied to the radius of the left forelimb. Four to 6 days later, foals were walked (5 sets of 10 to 20 strides), and compressive and tensile strains in the bone beneath strain gauges were recorded on paper and diskette. After recording base-line data, a wedge was fitted to the hoof of the limb with the strain gauges, in such a way that the lateral bearing surface was raised, and strain...