Analyze Diet

Topic:Tendons

Tendons in horses are fibrous connective tissues that attach muscles to bones, facilitating movement and providing stability to the musculoskeletal system. They are composed primarily of collagen fibers, which confer strength and flexibility, allowing horses to perform various physical activities. Equine tendons are subject to significant mechanical stress during locomotion, making them susceptible to injury, particularly in performance horses. Common tendon injuries include strains, tears, and tendinitis, which can impact a horse's mobility and performance. This page compiles peer-reviewed research studies and scholarly articles that explore the structure, function, and pathology of tendons in horses, as well as advancements in diagnostic and therapeutic approaches for tendon injuries.
Identification of subclinical tendon injury from ground reaction force analysis.
Equine veterinary journal    July 1, 1991   Volume 23, Issue 4 266-272 doi: 10.1111/j.2042-3306.1991.tb03715.x
Dow SM, Leendertz JA, Silver IA, Goodship AE.In this study a method of analysing ground reaction forces was developed to help in the diagnosis of subclinical flexor tendon injury. A Kistler force plate was used to obtain records from a population of Thoroughbreds in National Hunt training over a period of two years. Characteristic features of the force patterns generated were measured and shown to have low variance, both between horses and over a period of two racing seasons in animals that were sound throughout the trial. Specific changes in the loading pattern of the limb, which correlated with injury of the superficial digital flexor ...
Effects of sodium hyaluronate on tendon healing and adhesion formation in horses.
American journal of veterinary research    May 1, 1991   Volume 52, Issue 5 764-773 
Gaughan EM, Nixon AJ, Krook LP, Yeager AE, Mann KA, Mohammed H, Bartel DL.Sodium hyaluronate reduces adhesions after tendon repair in rodents and dogs, and has been used in limited clinical trials in people. To evaluate its effect on tendon healing and adhesion formation in horses and to compare these effects with those of a compound of similar visco-elastic properties, a study was performed in horses, using a model of collagenase injection in the flexor tendons within the digital sheath. Eight clinically normal horses were randomly allotted to 2 groups. Adhesion formation between the deep digital flexor tendon and the tendon sheath at the pastern region was induced...
[Soft tissue lesions of the equine carpus: roentgenological and echographic studies].
Tijdschrift voor diergeneeskunde    December 15, 1990   Volume 115, Issue 24 1168-1174 
Dik KJ.Common soft tissue disorders of the equine carpus are fluctuating or firm soft tissue swellings, wounds and draining tracts. Survey radiography may show the size, position and origin of the swellings and reveals soft tissue calcification, accumulation of air and radiopaque foreign material. Contrast radiography enables accurate visualization of the size, shape, position and origin of fluctuating soft tissue swellings, demonstrates abnormal intersynovial communication and allows precise demonstration of the extent of puncture wounds and draining tracts. Ultrasonography allows differentiation be...
Effect of antimicrobial solution lavage on the palmar digital tendon sheath in horses.
American journal of veterinary research    September 1, 1990   Volume 51, Issue 9 1488-1494 
Baird AN, Scruggs DW, Watkins JP, Taylor TS.Sixteen horses were allotted to 4 groups of 4 horses each to evaluate the effect of tendon sheath lavage with 4 solutions (balanced electrolyte solution, 0.1% povidone-iodine, 0.5% povidone-iodine, and 0.5% chlorhexidine). The synovitis caused by 0.1% povidone-iodine lavage was not appreciably worse than that caused by balanced electrolyte solution lavage, but the 0.5% povidone-iodine and chlorhexidine lavages caused severe synovitis, and, therefore, should not be used for tendon sheath lavage.
Endoscopy of the digital flexor tendon sheath in horses.
Veterinary surgery : VS    July 1, 1990   Volume 19, Issue 4 266-271 doi: 10.1111/j.1532-950x.1990.tb01182.x
Nixon AJ.An arthroscopic procedure for examination of the digital flexor tendons and tendon sheath was developed in 16 equine limbs and 12 horses. Distension of the tendon sheath and insertion of the arthroscope was accomplished through a cul-de-sac on the palmar or plantar surface of the tendon sheath 1 to 2 cm palmar or plantar to the digital neurovascular structures and between the annular ligament and proximal digital annular ligament. A single arthroscope entry point allowed examination of all regions of the tendon sheath cavity and most surfaces of the digital flexor tendons within the sheath. Di...
Equine synovial tendon sheaths and bursae: an histological and scanning electron microscopical study.
Equine veterinary journal    July 1, 1990   Volume 22, Issue 4 264-272 doi: 10.1111/j.2042-3306.1990.tb04265.x
Hago BE, Plummer JM, Vaughan LC.The structure of equine synovial tendon sheaths and bursae has been examined by light and scanning electron microscopy. Tissue samples were obtained from horses of various types and ages with no clinical evidence of sheath or bursal disorders. The interior of both structures was lined by a cellular layer superimposed on a vascular zone supported by a fibrous layer. The pattern of cell distribution of the lining varied from site to site within the same structure depending on the nature of the underlying tissue and on the amount of movement to which the structure was subjected. The cellular laye...
A comparison of repair methods for gap healing in equine flexor tendon.
Veterinary surgery : VS    July 1, 1990   Volume 19, Issue 4 254-265 doi: 10.1111/j.1532-950x.1990.tb01181.x
Bertone AL, Stashak TS, Smith FW, Norrdin RW.In nine horses (18 forelimbs), a 3 cm section of superficial digital flexor tendon was removed and the tendons were repaired with immobilization for 6 weeks and (1) no suture (n = 6); (2) a double locking loop tenorrhaphy with carbon fiber (n = 6); or (3) a double locking loop tenorrhaphy with size 2 nylon suture (n = 6). Clinical assessment, gross evaluation, morphometry, histology, and mechanical testing were performed on two limbs from each treatment group at weeks 6, 12, and 24. At weeks 6 and 12, the unsutured tissue was less mature than the tissue sutured with nylon. By week 24, the carb...
What is your diagnosis? Tendinitis of the superficial digital flexor tendon.
Journal of the American Veterinary Medical Association    May 15, 1990   Volume 196, Issue 10 1671-1672 
Strasser S, Solomon B.No abstract available
Age- and position-related heterogeneity of equine tendon extracellular matrix composition.
Research in veterinary science    May 1, 1990   Volume 48, Issue 3 357-364 
Jones AJ, Bee JA.The digital flexor tendons of the neonate and adult horse have been compared with respect to variation in extracellular matrix composition along their length. Two pepsin-sensitive, acetic acid soluble proteins, molecular weight (Mr) 52 kD (np 52) and Mr 54 kD (np 54), were prominent throughout the length of neonatal tendons. In adult tendon, np 52 and np 54 were less abundant and restricted to the cannon (metacarpal) region. In contrast, a single pepsin- and collagenase-resistant protein of Mr 55 kD (fp 55) was exclusive to the fetlock (metacarpophalangeal joint) region regardless of age, alth...
Clinical experience with quantitative analysis of superficial digital flexor tendon injuries in Thoroughbred and Standardbred racehorses.
The Veterinary clinics of North America. Equine practice    April 1, 1990   Volume 6, Issue 1 129-145 doi: 10.1016/s0749-0739(17)30560-6
Genovese RL, Rantanen NW, Simpson BS, Simpson DM.A method to quantitate as well as to document SDFT pathology has been described. This report indicates that computer-assisted evaluation of SDFT damage can improve the accuracy of prognosis in clinical practice. It would appear that a 3.8 severity rating is a limit past which prognosis for successful racing starts to worsen rapidly.
Pathologic findings and pathogenesis of racetrack injuries.
The Veterinary clinics of North America. Equine practice    April 1, 1990   Volume 6, Issue 1 1-30 doi: 10.1016/s0749-0739(17)30555-2
Pool RR, Meagher DM.Many lesions of the musculoskeletal system of racing horses are either acute traumatic lesions or are chronic biomechanically induced lesions that become suddenly unstable and provoke acute clinical signs. The latter lesions along with those of DJD are much more common and are of much greater overall economic importance to the racing industry than are the acute traumatic injuries. Chronic biomechanical lesions occur at predictable sites and are the result of an imbalance between repetitive microtrauma sustained in athletic performance and adaptive repair mechanisms of skeletal tissues. The dis...
Orthopedic surgery in the racehorse.
The Veterinary clinics of North America. Equine practice    April 1, 1990   Volume 6, Issue 1 147-177 doi: 10.1016/s0749-0739(17)30561-8
Foerner JJ, McIlwraith CW.This article attempts to address what the authors consider to be the major orthopedic problems in the racehorse, with particular attention to their treatment and prognosis. These problems include fractures, osteochondral fragments, synovitis, degenerative joint disease, tendinitis, desmitis, osteochondritis dissecans, and subchondral cystic lesions of the joints.
Mechanical properties of four suture patterns for transected equine tendon repair.
Veterinary surgery : VS    March 1, 1990   Volume 19, Issue 2 102-106 doi: 10.1111/j.1532-950x.1990.tb01149.x
Easley KJ, Stashak TS, Smith FW, Van Slyke G.Thirty-six superficial digital flexor tendons from nine fresh equine cadavers were transected and sutured with size 2 monofilament nylon. Nine tendons were repaired with each of four suture patterns: single-locking loop, double-locking loop, triple-locking loop, or three-loop pulley. The times required for application, tensile strengths, resistance to distraction (gap), and modes of failure were analyzed. The mean times required were: single-locking loop, 3 mins, 15 secs; double-locking loop, 4 mins, 15 secs; triple-locking loop, 10 mins, 50 secs; and three-loop pulley, 4 mins. The double-lock...
Strength characteristics and failure modes of locking-loop and three-loop pulley suture patterns in equine tendons.
Veterinary surgery : VS    January 1, 1990   Volume 19, Issue 1 28-33 doi: 10.1111/j.1532-950x.1990.tb01139.x
Jann HW, Stein LE, Good JK.Size 3-0 polydioxanone was used as a single strand, single braid (3 strands), or double braid (6 strands) to create six suture material-pattern combinations for equine tenorrhaphy: single-strand locking loop, single-braid locking loop, double-braid locking loop, single-strand three-loop pulley, single-braid three-loop pulley, and double-braid three-loop pulley. Maximum load to failure for the single-strand locking loop (46.1 +/- 2.9 newtons [N]) was less than for all other sutures (range, 103-155 N). The load required to form a 2 mm gap between tendon ends was greater for the single-braid thre...
Management of traumatic tendon lacerations.
The Veterinary clinics of North America. Equine practice    December 1, 1989   Volume 5, Issue 3 575-590 doi: 10.1016/s0749-0739(17)30576-x
Spurlock GH.This article deals with the diagnosis and treatment of tendon lacerations. Tendon healing, with its implications relative to treatment, is discussed. The various pros and cons of suturing severed tendons are addressed as well as methods of immobilizing the injured limb. The need for prompt diagnosis and aggressive treatment of tendon sheath injuries is also discussed.
Tendon strains in horses.
American journal of veterinary research    November 1, 1989   Volume 50, Issue 11 1989 
Riemersma DJ.No abstract available
Dorsal subluxation of the proximal interphalangeal joint in the pelvic limb of three horses.
Journal of the American Veterinary Medical Association    September 15, 1989   Volume 195, Issue 6 777-780 
Shiroma JT, Engel HN, Wagner PC, Watrous BJ.In horses, dorsal subluxation of the proximal interphalangeal joint in the pelvic limb, which realigned when weight was applied to the limb, improved following surgery. Improvement was observed, if not immediately, at least within two weeks after treatment. The severity and duration of the condition appear to be important considerations in predicting the time necessary for resolution of the condition following surgery. Treatment consisted of surgical resection of a small segment of the medial head of the deep digital flexor tendon in the pelvic limb. The section removed was positioned distal t...
Lateral luxation of the superficial digital flexor tendon from the calcaneal tuber in two horses.
Journal of the American Veterinary Medical Association    August 15, 1989   Volume 195, Issue 4 495-498 
Meagher DM, Aldrete AV.Lateral luxation of the superficial digital flexor tendon from the calcaneal tuber occurs in horses as a result of tearing or rupture of the medial retinaculum of the tendon. This report describes the repair of this condition in 2 Thoroughbred race horses, using a surgical technique in which 2 cancellous bone screws were placed in the calcaneus lateral to the tendon, along with suturing the medial retinaculum.
Application of a Hall-effect transducer for measurement of tendon strains in horses.
American journal of veterinary research    July 1, 1989   Volume 50, Issue 7 1089-1095 
Stephens PR, Nunamaker DM, Butterweck DM.Custom-designed Hall-effect strain sensors (HES) were implanted surgically onto the superficial digital flexor tendons of the forelimbs of 4 adult Thoroughbreds. Strains were recorded at various gaits, using a portable amplifer and FM cassette recorder. Strain calculations used the original length (L) as the HES position with the forelimb in the relaxed neutral position during anesthesia. A characteristic deflection in the strain cycle recording was confirmed to correspond to initial hoof contact with the ground (heel strike) by simultaneous recording of weight bearing via a footswitch. Heel s...
The developmental anatomy of the equine navicular bursa and associated structures.
Anatomy and embryology    January 1, 1989   Volume 179, Issue 4 355-367 doi: 10.1007/BF00305062
Hoffer MA, Leach DH, Doige CE.The navicular bone, navicular bursa and their associated structures were collected from 20 horses ranging in age from 80 days gestation to 2 years post-gestation. The right front foot of every horse was sampled for light microscopy. The development of the navicular bursa and associated structures were studied. Study of the developmental anatomy of the equine navicular bursa established that the bursa is a distinct entity in both the fetus and the adult horse. Development of the bursal cavity in the fetus was found to be complete by 120 days of gestation. Synovial membrane of the navicular burs...
[Diagnostic sonography of the limb of the horse].
Tierarztliche Praxis. Supplement    January 1, 1989   Volume 4 47-55 
van Schie HT.The ultrasonic examination of tendons and ligaments of the distal limb of the horse improves the diagnostic possibilities of these frequently injured structures. The successful application is based upon a reliable knowledge of the normal sonographic anatomy and upon a standardized, flawless technic of the examination. Practice and experience allow the recognition of minor alterations which enables a more precise diagnosis, a more reliable prognosis, and in follow-up examinations also more specific information about the further use of the horse.
Solitary osteochondroma of the radius in three horses.
Journal of the American Veterinary Medical Association    September 1, 1988   Volume 193, Issue 5 563-564 
Held JP, Patton CS, Shires M.Osteochondroma of the distal portion of the radius was diagnosed in 3 horses with a history of lameness and distention of the common tendon sheath of the superficial and deep digital flexor tendons at the level of the carpal canal. In 2 horses, the exostosis was removed through an incision at the caudal border of the lateral digital extensor muscle above the carpal ligament.
Kinetics and kinematics of the equine hind limb: in vivo tendon loads and force plate measurements in ponies.
American journal of veterinary research    August 1, 1988   Volume 49, Issue 8 1344-1352 
Riemersma DJ, Schamhardt HC, Hartman W, Lammertink JL.Loads on the suspensory ligament, deep digital flexor tendon, superficial digital flexor tendon, and long digital extensor tendon of the equine hind limb were determined in ponies by use of implanted strain gauges consisting of silicone rubber tubes filled with mercury. Recordings were made simultaneously with force plate measurements and high-speed film recordings while the ponies were walking. The relationship between strain gauge signals and tendon loads was obtained from tension-strain tests performed after death of the ponies. The suspensory ligament and the 2 digital flexor tendons were ...
Kinetics and kinematics of the equine hind limb: in vivo tendon strain and joint kinematics.
American journal of veterinary research    August 1, 1988   Volume 49, Issue 8 1353-1359 
Riemersma DJ, van den Bogert AJ, Schamhardt HC, Hartman W.Strains of the suspensory ligament and deep digital flexor, superficial digital flexor, and long digital extensor tendons in the equine (pony) hind limb were recorded in vivo, using implanted strain gauges consisting of silicone rubber tubes filled with mercury. The relationship between strain gauge signals and tendon strains was obtained from tension-strain tests performed on isolated tendons after death of the ponies. During normal walking, maximal tendon strain (elongation over initial length, relative to the length of the structures at first ground contact) was 3.1% in the suspensory ligam...
Calibration of the mercury-in-silastic strain gauge in tendon load experiments.
Journal of biomechanics    January 1, 1988   Volume 21, Issue 6 469-476 doi: 10.1016/0021-9290(88)90239-4
Riemersma DJ, Lammertink JL.A calibration method is presented by which the signals of mercury-in-silastic strain gauges (MISS), implanted in the tendons of in vitro loaded equine hindlegs, were converted to tendon loads. The relationships between MISS-signals and tendon loads were obtained from tensile-force tests applied to the tendons. Special attention was paid to the correction of the MISS-signals for amplitude-shifts resulting from internal repositioning of the MISS after tendon isolation and temperature differences. Shift corrections equivalent to tendon strains up to 2.8% were necessary in the in vitro experiment....
[Avulsion fracture of the tendon of origin of the long extensor muscle of the toe in a horse and a cat].
Tijdschrift voor diergeneeskunde    December 15, 1986   Volume 111, Issue 24 1225-1228 
Voorhout G, Klein WR, Meutstege FJ.An avulsion fracture of the tendon of origin of the extensor digitorum longus muscle is reported in a horse and a cat. This avulsion fracture was due to injury in both animals. There was a striking similarity of radiographic findings in these animals, with involvement of the lateral trochlear ridge and lateral condyle of the femur. The horse was slaughtered because of a poor prognosis as a riding-horse. Fixation of the avulsed fragment with two Kirschner wires resulted in complete recovery in the cat.
Preliminary study of tendon biopsy in the horse.
Equine veterinary journal    September 1, 1986   Volume 18, Issue 5 383-387 doi: 10.1111/j.2042-3306.1986.tb03659.x
Webbon PM.A series of experimental tendon biopsies is described. Three biopsies were taken from the lateral digital extensor tendon (LDET) and three from the superficial flexor tendon (SFT). The LDET biopsies resulted in little discomfort whereas the SFT biopsies led to temporary lameness. The tendons were examined histologically up to 99 days after the biopsies were removed. In all of the tendons the defect filled with granulation tissue which subsequently became organised as a longitudinally orientated collagenous scar tissue. In this small series of biopsies the histological effects of the biopsy per...
[Treatment of tendinitis in the horse].
Berliner und Munchener tierarztliche Wochenschrift    July 1, 1986   Volume 99, Issue 7 226-231 
Keller H, Jördens P.No abstract available
Variations in cross-sectional area and composition of equine tendons with regard to their mechanical function.
Research in veterinary science    July 1, 1986   Volume 41, Issue 1 7-13 
Riemersma DJ, De Bruyn P.The cross-sectional area, collagen content, dry weight as a percentage of the wet weight and the tendon fibre percentage of the cross-sectional area of the equine hindlimb were determined in the superficial and deep digital flexor tendons and the suspensory ligament at 10, 12 and six sites between tarsus and insertion respectively. The values of each of the four parameters varied between different sites in the same tendon, between different tendons within a horse and between analogous tendons of different horses. Within a tendon the cross-sectional area was inversely proportional to the collag...
Onchocerca spp: frequency in Thoroughbreds at necropsy in Kentucky.
American journal of veterinary research    April 1, 1986   Volume 47, Issue 4 880-882 
Lyons ET, Tolliver SC, Drudge JH, Swerczek TW, Crowe MW.Examination of the ligamentum nuchae for Onchocerca spp was completed in 523 Thoroughbreds (1 to 29 years old) at necropsy in Kentucky during a 13-month period (1984 to 1985). Onchocerca spp were found in 306 (59%) of the horses. Frequencies of this parasite were 3%, 17%, 40%, 43%, and 42% in 1-, 2-, 3-, 4-, and 5-year-old horses, respectively. For 6- to 29-year-old horses, frequency varied from 71% to 100%, except for 26-year-old horses (50%); 87% of the 304 horses examined in the 6- to 29-year-old age groups was infected. The suspensory ligaments and flexor tendons from fetlocks (thoracic li...