Urine analysis in horses involves the examination of urine to assess the health and physiological status of the animal. This diagnostic tool provides insights into the renal function, hydration status, and potential presence of systemic diseases. Key parameters evaluated in equine urine analysis include pH, specific gravity, protein levels, glucose, ketones, and the presence of blood or sediment. Variations in these parameters can indicate metabolic disorders, infections, or other health issues. This page compiles peer-reviewed research studies and scholarly articles that explore the methodologies, findings, and clinical implications of urine analysis in equine veterinary practice.
Dumasia MC, Houghton E, Bradley CV, Williams DH.The metabolism and urinary excretion of 1,2(n)-3H-1-dehydrotestosterone were studied in cross-bred gelded horses. Approximately 40% of the dose was excreted in 24 h. The steroid metabolites were extracted by Amberlite XAD-2 resin and fractionated into glucuronides and sulphoconjugates. Unchanged 1-dehydrotestosterone was the only component identified by gas chromatography mass spectrometry after solvolysis of the sulphoconjugates. Positive and negative ion fast atom bombardment mass spectra were obtained on the purified 1-dehydrotestosterone sulphoconjugate isolated from horse urine and on the...
Combie JD, Nugent TE, Tobin T.Morphine could be detected in horses dosed with 0.1 mg of drug/kg of body weight for up to 48 hours in blood and 144 hours in urine. This dose of morphine elicited no observable effects and is a suggested analgesic dose. Computer analysis revealed that a 3-compartment open system was the best fitting model with a serum half life (t1/2(beta)) of 87.9 minutes and a urine t1/2(beta) of 101.1 minutes. Binding to equine serum proteins was linear over a drug concentration range of 3.88 X 10(-5)M to 3.50 X 10(-8)M and averaged 31.6%. In RBC-partitioning experiments, 78.1% of the drug was found in the...
Marsh MV, Caldwell J, Sloan TP, Smith RL, Horner M, Moss MS.14C-Fenclofenac (2-(2'-4'-dichlorophenoxy)-phenylacetic acid) was administered orally to horses, and urinary metabolites investigated by chromatography. Fenclofenac was rapidly absorbed and eliminated, with a plasma half-life (t1/2) of 2.3 h, with 83.2 and 85.8% of the dose being recovered in the urine in 0-24 h. The major urinary metabolite was the ester glucuronide (58.8, 70.0% dose), and evidence is presented that this metabolite undergoes a structural rearrangement to give beta-glucuronidase-resistant isomers. The other 14C-labelled components in horse urine were unchanged fenclofenac (13....
Brown MP, Kelly RH, Stover SM, Gronwall R.Six healthy adult mares were given a single IV injection of trimethoprim (TMP)-sulfadiazine (SDZ) at a dosage rate of 2.5 mg of TMP/kg of body weight and 12.5 mg of SDZ/kg. Serum, synovial, peritoneal, and urine TMP-SDZ concentrations were measured serially over a 48-hour period. The highest measured mean concentrations of TMP and SDZ were found in the first (0.5 hour) sample of serum, synovial fluid, and peritoneal fluid. The mean peak concentrations of TMP and SDZ averaged 4.37 micrograms/ml and 21.81 micrograms/ml for serum, 2.95 micrograms/ml and 15.31 micrograms/ml for synovial fluid, and...
Lane VM, Merritt AM.In 4 healthy horses and 1 Welsh pony, fractional renal excretions of phosphorus (FEp) determined from 9 hourly time collections taken over a 24-hour period were compared to assess whether a single-sample collection would be an accurate indicator of the daily FEp. The mean FEp for each animal varied from 0.115% to 0.302%; the 2 animals with the highest values were significantly different (P less than 0.05) from the 3 with the lowest values. Individual variation within animals was not great, however, because it was calculated that the 24-hour FEp value could be found within +/- 0.087% of the sin...
Tobin T.In general, blood is the only material on which a practical pre-race testing scheme can be based. Blood testing is not as sensitive as urine testing and detects only about 66 per cent of the drugs detectable in urine. Therefore, pre-race blood testing is always performed in conjunction with post race urine testing. Because blood is easily and rapidly drawn, the use of blood samples in all post race testing schemes is recommended. Pre-race testing is also a relatively expensive proposition, but it is the only method which actually prevents the running of an illegally medicated horse.
Greene EW, Woods WE, Tobin T.Caffeine (4 mg/kg) was given by rapid IV injection to 4 horses. Plasma concentrations of the drug peaked at 10 micrograms/ml and decreased rapidly at first, and then more slowly, with an apparent beta-phase half-life of 18.2 hours. Urinary concentrations of caffeine were remarkably consistent at about 3 times plasma values of the drug. Caffeine was detectable in both plasma and urine of the horses for up to 9 days after dosing. After oral administration, caffeine was absorbed poorly with an apparent bioavailability of 39%. Although blood concentrations of caffeine peaked rapidly after oral adm...
Roberts MC, Seawright AA, Ng JC, Norman PD.Chronic mercuric chloride intoxication in an aged horse given 0.8 mg Hg/kg/day for 14 weeks was manifest by signs of progressive respiratory difficulty and renal disease. The effects were not self-limiting after mercury was withdrawn, and the animal was destroyed six weeks later. Renal function changes included heavy glycosuria, modest proteinuria, phosphaturia, reduced urine osmolality, gradually increasing urine production, reduced glomerular filtration rate, and terminally, azotemia. The condition bore similarities to the Fanconi syndrome in man. Urinary gamma-glutamyl transpeptidase, alkal...
Houghton E, Teale P, Dumasia MC, Wellby JK.The negative ion chemical ionization mass spectra of the MO-TMS derivatives of the corticosteroids prednisolone, betamethasone and dexamethasone have been obtained using capillary column gas chromatography mass spectrometry. The spectra showed abundant diagnostic ions at m/z greater than 300 allowing for clear discrimination between the three steroid derivatives. A capillary column gas chromatographic mass spectrometric method using negative ion chemical ionization mass spectrometry has been developed to confirm the presence of the parent steroids in horse urine following the administration of...
Marsh MV, Caldwell J, Hutt AJ, Smith RL, Horner MW, Houghton E, Moss MS.The metabolism of benzoic acid has been examined in the horse, using 14C- and deuterium-labelled compounds. Chromatographic analysis of the urine showed the presence of hippuric acid, benzoyl glucuronide and benzoic acid and a discrete band which accounted for 2% of the dose administered. This material was isolated by solvent extraction and HPLC and, following treatment with diazomethane, examined by GC/MS. The major component of this fraction was 3-hydroxy-3-phenylpropionic acid methyl ester, which was accompanied by very much smaller amounts of cinnamic acid methyl ester and acetophenone. Th...
Muir WW, Sams RA, Huffman RH, Noonan JS.The cardiopulmonary, behavioral, and pharmacokinetic properties of diazepam were determined in horses. Heart rate, cardiac output, mean pulmonary artery, aortic and right atrial blood pressures, respiratory rate, and arterial pH and blood gas values did not change after IV diazepam (0.05, 0.1, 0.2, 0.4 mg/kg) administration. Increasing doses of diazepam resulted in signs of muscle weakness including fixed stance, muscle fasciculations of the head, neck, and thorax muscles, ataxia, and then recumbency. Dosages of diazepam exceeding 0.2 mg/kg produced mild sedation. Behavioral changes persisted ...
Alexander F.The effect of ethacrynic acid, bumetanide, frusemide, spironolactone and anti-diuretic hormone (ADH) on the urinary and faecal excretion of water and electrolytes by ponies was studied. Ethacrynic acid, bumetanide, and frusemide given intravenously, increased urinary sodium excretion, and, excepting frusemide, decreased faecal sodium excretion. Given by stomach tube ethacrynic acid reduced urinary and faecal sodium. Bumetanide, given intravenously, spironolactone, frusemide and ADH increased urinary sodium and all except frusemide intravenously decreased faecal sodium regardless of route of ad...
Snow DH, Munro CD, Nimmo MA.The effect of 11 weekly injections of nandrolone phenylpropionate (400 mg) was investigated by a crossover trial (2 training periods) in 6 Thoroughbred geldings undergoing training. A decrease in body weight and flank measurement occurred only during the first training period and was not modified by the anabolic steroid. Urinary nitrogen excretion was lower in the anabolic treated animals only in the first training period. Neither training nor training plus nandrolone phenylpropionate administration caused any marked alteration in blood biochemistry or haematology. A significant decrease in pl...
Chapman DI, Close PM, Moss MS, Snow DH.A radioimmunological method was used as a screening procedure to determine the period of detection or "clearance time", for the horse, of therapeutic doses of the synthetic anabolic steroid nandrolone phenylpropionate. Seven horses, either at rest or being exercised, were given a course of weekly intramuscular injections of the steroid. On the separate occasion, some of the horses were given a single intramuscular injection of the same compound. The weekly injections maintained a high plasma concentration of nandrolone and/or metabolites. The mean (+/- sd) period of detection in plasma of thes...
Brown MP, Stover SM, Kelly RH, Farver TB.Ten healthy adult mares were given a single intramuscular dose (2.2 mg/kg) of gentamicin sulfate. Over a 48-h period, gentamicin concentrations were measured serially in the serum of all ten mares and in synovial fluid, peritoneal fluid, and urine of six of the mares. The mean peak serum gentamicin concentration was 5.73 micrograms/ml at 1 h. Gentamicin was detected in synovial fluid and peritoneal fluid, with mean peak gentamicin concentrations of 2.41 micrograms/ml and 3.92 micrograms/ml, respectively, observed at 2 h. These concentrations declined in parallel with serum concentrations and w...
Caple IW, Bourke JM, Ellis PG.The calcium and phosphorus nutrition of thoroughbred racehorses was assessed by analysis of serum and urine samples collected from 90 horses in 1975 and 139 horses in 1980-81 at racetracks in Melbourne. Horses that were excreting greater than 15 mumole Ca/mosmole and which had a calcium to creatinine clearance ratio greater tha 2.5% were considered to have adequate Ca intake. Horses that were excreting greater than 15 mumole P/mosmole and which had a phosphorus to creatinine clearance ratio greater than 4% were considered to have excessive phosphorus intake. Sixty-percent of the horses sampled...
Caple IW, Doake PA, Ellis PG.Studied were made to determine if a practical assessment of the calcium and phosphorus nutrition of horses could be obtained from an analysis of urine samples. The concentrations of Ca and P in urine samples changed markedly when groups of 4 mares were fed diets containing from 1.0 to 3.9 g Ca/kg and from 1.5 to 6.1 g P/kg, but serum concentrations of Ca and P remained relatively constant. The concentrations in single urine samples were considered unreliable indicators of excretion of the minerals because of variations in water excretion, and two methods to overcome this problem were examined....
Alexander F.Phenylbutazone administered in therapeutic doses to ponies decreased urinary sodium and chloride excretion. The volume and osmolality of the urine was unaffected as was potassium excretion. Faecal excretion of chloride decreased and that of potassium increased, while faecal sodium excretion was unaffected. Plasma pH, bicarbonate and total carbon dioxide decreased after phenylbutazone administration. Packed cell volume, plasma sodium, potassium, carbon dioxide tension and chloride were unchanged.
Houghton E.The methylated xanthines caffeine and/or theobromine are commonly encountered in drug-positive samples from racehorses and their metabolism and excretion in the horse and their analysis in urinary extracts has been of particular interest in this laboratory. Due to their polar nature the dimethylxanthines theobromine, theophylline and paraxanthine give unsatisfactory gas chromatographic performance and require derivatization prior to analysis by gas chromatography mass spectrometry. The present paper describes a simple deuteromethylation procedure to render the compounds amenable to analysis by...
Ballard S, Shults T, Kownacki AA, Blake JW, Tobin T.After intravenous (i.v.) injection, acepromazine was distributed widely in the horse (Vd = 6.6 litres/kg) and bound extensively (greater than 99%) plasma proteins. Plasma levels of drug declined with an alpha half-life of 4.2 min, while the beta phase or elimination half-life was 184.8 min. At a dosage level of 0.3 mg/kg acepromazine was detectable in the plasma for 8 h post dosing. The whole blood partitioning of acepromazine was 46% in the plasma phase and 54% in the erythrocyte phase. Penile prolapse was clearly evident at doses from 0.01 mg/kg to 0.4 mg/kg i.v., and the duration and extent...
Grossman BS, Brobst DF, Kramer JW, Bayly WM, Reed SM.The urine urea nitrogen/plasma urea nitrogen ratio (Uun/Pun), urine creatinine/plasma creatinine ratio (Ucr/Pcr), urine osmolality/plasma osmolality ratio (Uosm/Posm), and fractional excretion of filtered sodium (FENa) were evaluated in 16 horses with acute azotemia to ascertain the significance of each index in the differentiation of prerenal azotemia from renal azotemia. Renal azotemia was diagnosed when renal biopsy or postmortem histologic examination demonstrated evidence of organic renal disease or when azotemia was found in the presence of isosthenuria. The diagnosis of prerenal azotemi...
Brown MP, Stover SM, Kelly RH, Farver TB.Six adult mares were given a single dose of ampicillin trihydrate (250 mg/ml) intramuscularly at a dosage of 20 mg/kg body weight. Serum, synovial fluid, peritoneal fluid and urine ampicillin concentrations were measured serially over a 48 h period. The mean peak serum ampicillin concentration was 2.49 micrograms/ml at 6 h. Ampicillin was found in synovial fluid and peritoneal fluid, which obtained mean peak ampicillin concentrations of 1.65 micrograms/ml and 1.81 micrograms/ml at 6 h and 4 h respectively. These concentrations declined in parallel with serum concentrations and were still detec...
Combie J, Blake JW, Nugent TE, Tobin T.We have investigated the action of five sources of beta-glucuronidase enzymes on the hydrolysis of glucuronides of apomorphine, butorphanol, hydromorphone, nalbuphine, oxymorphone and pentazocine in equine urine. For all glucuronides tested, Patella vulgata beta-glucuronidase yielded the largest thin layer chromatographic (TLC) spots. For oxymorphone, P. vulgata was the only treatment to yield detectable TLC spots under test parameters. For these six drugs, TLC spot size and chromatographic quality were compared between control horses and horses pretreated with furosemide four hours earlier. F...
Chapman DI, Close PM, Moss MS, Snow DH.A radioimmunological method was used as a screening procedure to determine the period of detection or "clearance time", for the horse, of therapeutic doses of the synthetic anabolic steroid nandrolone phenylpropionate. Seven horses, either at rest or being exercised, were given a course of weekly intramuscular injections of the steroid. On the separate occasion, some of the horses were given a single intramuscular injection of the same compound. The weekly injections maintained a high plasma concentration of nandrolone and/or metabolites. The mean (+/- sd) period of detection in plasma of thes...
Assis RA, Kuchler IL, Miekeley N, Tozzi MB.Capillary electrophoresis coupled to inductively coupled plasma mass spectrometry was used in a speciation study on disodium monomethylarsonate (DS-MMA(V)) and its metabolites in horses, to which the drug was administered by intramuscular injection on five consecutive days at a single arsenic dosage of 270 mg day(-1). Samples of urine, whole blood, plasma, and mane hair were analyzed before, during, and after drug administration. The data show that blood clearing and urinary excretion of MMA is a fast process following first-order kinetics with biological half-lives of about 38 h and 44 h for ...
McKenzie EC, Valberg SJ, Godden SM, Pagan JD, Carlson GP, MacLeay JM, DeLaCorte FD.To determine daily variation in urinary clearance and fractional excretion (FE) of electrolytes and minerals within and between horses and to compare volumetric and single-sample urine collection for determining FE values of diets with a range of dietary cation-anion balance (DCAB). Methods: 5 Thoroughbred and 6 mixed-breed mares. Methods: 3 isocaloric diets with low, medium, and high DCAB values (85, 190, and 380 mEq/kg of dry matter, respectively) were each fed for 14 days. Daily blood samples, single urine samples collected by using a urinary catheter (5 mares), and volumetric urine collect...
Cloteau C, Dervilly G, Loup B, Delcourt V, Kaabia Z, Bagilet F, Groseille G, Dauriac K, Fisher S, Popot MA, Garcia P, Le Bizec B, Bailly-Chouriberry L.Despite their ban, Anabolic Androgenic Steroids (AAS) are considered as the most important threat for equine doping purposes. In the context of controlling such practices in horse racing, metabolomics has emerged as a promising alternative strategy to study the effect of a substance on metabolism and to discover new relevant biomarkers of effect. Based on the monitoring of 4 metabolomics derived candidate biomarkers in urine, a prediction model to screen for testosterone esters abuse was previously developed. The present work focuses on assessing the robustness of the associated method and def...
Ribeiro Neto LM, Salvadori MC, Spinosa HS.As hydrocortisone is an endogenous substance, it is first necessary to establish its normal concentrations so as to be able to control its use in racing animals. This study was designed to establish the hydrocortisone concentrations in post-race urine samples of horses racing in Brazil and also to evaluate the results in relation to the international threshold set for this drug. Urine samples were analysed by HPLC-UV. The results were evaluated according to the concentration range as well as sex and time of sample collection (afternoon or evening races). The results showed a high degree of var...
Karatt TK, Sathiq MA, Laya S, Ajeebsanu MPM, Karakka Kal AK, Subhahar MB, Perwad Z.Recently, there has been a report suggesting that ecdysteroids can enhance sports performance, making them relevant substances in doping control. Hence, it is imperative to examine the analytical characteristics of ecdysteroids in biological samples to identify their misuse in competitive sports. Methods: To assess the doping of ecdysteroids such as ecdysone, ecdysterone, ponasterone A, turkesterone, and ajugasterone C, a fast and sensitive extraction and detection method was developed, optimized, and validated using equine urine and plasma. Different extraction techniques, namely, solid-phase...
Jansson A, Lindholm A, Dahlborn K.The effect of a temporary increase in plasma aldosterone concentration on Na(+), K(+), and water balance was investigated in four horses. Aldosterone was injected intravenously for 6 h at 20-min intervals (total 5.4 microg/kg body wt). Samples were taken for 24 h before, during, and for 48 h after the treatment. Aldosterone treatment reduced the Na(+) loss via urine and feces by 99 and 72%, respectively, later followed by a marked increase in Na(+) excretion by both pathways. During the first 6 h after the treatment, fecal K(+) excretion was elevated, and the plasma K(+) concentration was lowe...
Whitwell KE, Harris P, Farrington PG.Four out of 12 horses grazing a field in Berkshire, England, suffered a prostrating illness and died within 12 to 72 h. Serum biochemical abnormalities, including markedly elevated muscle enzymes, were demonstrated and at post mortem widespread myodegeneration was found in both skeletal muscle and myocardium. Urine analysis revealed myoglobinuria, and renal changes were seen histologically. Although similar pathologically, the clinical syndrome and circumstances of the outbreak were not typical of equine exertional rhabdomyolysis (EER). The outbreak bore a striking resemblance to other reporte...
Choi MH, Kim JY, Chung BC.A highly specific method is described for measuring the testosterone:epitestosterone ratio in equine urine by gas chromatography-mass spectrometry (GC-MS) with stable isotope internal standards. The procedure was based on Serdolit Pad-1 resin extraction, enzymatic hydrolysis, and chemical derivatisation prior to instrumental analysis. The mixed derivatives, 3-trimethylsilyl-17-pentafluorophenyldimethylsilyl ether (3-TMS-17-flophemesyl) testosterone and epitestosterone, were found to have excellent analytical properties. The specificity of the derivatisation method exploits a unique feature of ...
Van Eenoo P, Deventer K, Delbeke FT.A sensitive, accurate and precise liquid chromatography/tandem mass spectrometry (LC/MS(2)) method was developed for the quantification of salmeterol in the urine of horses. The method consists of a liquid-liquid extraction with tert-butylmethyl ether and isopropanol at pH 12 after enzymatic hydrolysis. The extracts are analysed using an LC/MS system equipped with an electrospray ionisation (ESI) probe. Method validation showed excellent linearity, specificity, accuracy, precision and intra-laboratory repeatability and reproducibility. The limit of quantitative detection was 0.25 ng/mL and the...
Collins CW, Songsasen NS, Vick MM, Wolfe BA, Weiss RB, Keefer CL, Monfort SL.The ex situ population of the Przewalski's horse (Equus ferus przewalskii) is not self-sustaining (20% foaling rate), and the demography is skewed toward aging individuals with low gene diversity. We designed the present study to gain a better understanding of the reproductive biology of the Przewalski's mare and to determine whether age and gene diversity influenced reproductive function. Urine samples were collected 3-7 days/wk from 19 mares from May to September, and ultrasound examinations of follicular structures were performed 3 days/wk for 5 wk from May through July in nine individuals....
Singh AK, Ashraf M, Granley K, Mishra U, Rao MM, Gordon B.A simple and reproducible column (Clean Screen-DAU, copolymeric bonded-phase silica column) extraction procedure has been described for the screening and confirmation of drugs in horse urine. The recovery of drugs by the column extraction was better than or comparable to the recovery by the liquid-liquid extraction, which is commonly used in the equine analytical laboratories. The column extraction provided broad coverage of drugs, separated extracts into three fractions (acidic/neutral, steroids, basic), produced a cleaner extract, and eliminated the need for special liquid-liquid extraction ...
Smith RF, Jackson LS, Moore A.An 125I radioimmunoassay to determine the pattern of urinary excretion of etorphine (a semisynthetic opiate agonist) after its administration to horses is described. Three thoroughbred horses were each given 5, 15, 30 and 100 micrograms of etorphine intramuscularly. Urine was collected for up to 72 after administration. The maximum etorphine concentration after administration of a dose of 5 micrograms was 711 pg ml-1 (concentrations were greater than 100 pg ml-1 after 23 h in all three horses); a 15 micrograms gave 2661 pg ml-1 (levels remained above 100 pg ml-1 for more than 44 h in each hors...
Harding C, Viljanto M, Habershon-Butcher J, Taylor P, Scarth J.YK-11 is a steroidal selective androgen receptor modulator, a compound class prohibited in both equine racing and human sports because of their potentially performance enhancing properties. YK-11 is easily accessible via internet-based supplement vendors making this compound a possible candidate for doping; however, its phases I and II metabolism has not yet been reported in the horse. The purpose of this study was to investigate the in vivo metabolites of YK-11 in urine and plasma following oral administration with three daily doses of 50 mg to two Thoroughbred horses. In vitro incubations ...
Dehennin L, Bonnaire Y, Plou P.The dietary supplements 19-norandrostenedione and 19-norandrostenediol are potential metabolic precursors of nandrolone. They are considered by law in the United States as prohormones without proven therapeutic, curative or diagnostic properties, and therefore available as over-the-counter drugs. Oral dosages of 0.1-1 mg/kg body weight were readily absorbed in the equine intestinal tract and thereby led to urinary excretion of drastically increased 5alpha-estrane-3beta,17alpha-diol conjugates, which are known to be final metabolites of nandrolone. The actual rules for detection of illicit nand...
Fenwick SJ, Hincks PR, Scarth JP, Wieder ME, Hillyer LL, Paine SW.Salmeterol is a man-made beta-2-adrenergic receptor agonist used to relieve bronchospasm associated with inflammatory airway disease in horses. Whilst judicious use is appropriate in horses in training, they cannot race with clinically effective concentrations of medications under the British Horseracing Authority's Rules of Racing. Salmeterol must therefore be withdrawn prior to race day and pharmacokinetic (PK) studies used to establish formal detection time advice. Salmeterol xinafoate (Serevent Evohaler ) was administered (0.1 mg twice daily for 4.5 days) via inhalation to six horses. Ur...
Bernard WV, Bolin C, Riddle T, Durando M, Smith BJ, Tramontin RR.Leptospirosis was documented as the cause of abortion in a 5-year-old mare. Leptospires were detected in tissue specimens from fetal kidneys and from placenta by histologic evaluation of silver-stained sections. Antibodies against Leptospira interrogans serovar pomona were detected in fetal serum at a titer of 1,600 by use of a microscopic agglutination test. The mare had serum titers of 6,400; 0; 400; 800; 3,200; and 6,400 to L interrogans serovars bratislava, canicola, grippotyphosa, hardjo, icterohaemorrhagiae, and pomona, respectively. A serologic survey identified titers of at least 6,400...
Kranenburg LC, Westermann CM, de Sain-van der Velden MG, de Graaf-Roelfsema E, Buyse J, Janssens GP, van den Broek J, van der Kolk JH.Insulin resistance in horses is an emerging field of interest as it is thought to be a contributing factor in the pathogenesis of many equine conditions. Objective: The objectives of the present study were to determine the effects of long-term oral administration of L-carnitine on insulin sensitivity, glucose disposal, plasma leptin concentrations and acylcarnitine spectrum both in plasma and urine. Methods: Six 3-year-old healthy warmblood geldings were used. In a double blind 2 × 2 Latin square design at a dosage of 100 mg/kg body weight (BW)/day for 28 days the effects of oral supplementat...
Bhavnani BR, Woolever CA.A mixture of [4,8,12-14C]farnesyl pyrophosphate and [3H]dehydroepiandrosterone was injected into a horse fetus im during laparotomy, after which maternal urine was collected for 6 days. Steroid conjugates in the urine were extracted with Amberlite XAD-2 resin, hydrolyzed, and separated into phenolic and neutral fractions. Estrone, 17 alpha-estradiol, equilin [3-hydroxy-1,3,5(10),7-estratetraen-17-one], and 17 alpha-dihydroequilin [1,3,4(10),7-estratetraene-3,17 alpha-diol] were isolated from the phenolic fraction and their radiochemical purities were established. Only estrone and 17 alpha-estr...
Lloyd DR, Rose RJ, Duffield AM, Suann CJ.The combination of large doses of sodium bicarbonate and the potent narcotic, etorphine, has reportedly been given to racehorses in attempts to improve their performance and also to "mask" the presence of etorphine in urine samples. The increased urinary output and pH associated with sodium bicarbonate (approximately 500 g) administration may reduce the urinary concentration of etorphine, making it more difficult to detect. Our experiment was designed to examine the effects of this combination. Six Thoroughbred horses were used in a latin-square design with three horse pairs and three treatmen...
Wang CC, Hartmann-Fischbach P, Krueger TR, Wells TL, Simonson A, Compton JC.Due to opiorphin's analgesic and antidepressant functions, its illicit use is rumored in some racing jurisdictions. Opiorphin is very difficult to detect due to its hydrophilic nature and rapid degradation in plasma and urine samples. METHODOLOGY & RESULTS: We have developed a sensitive, reliable method for opiorphin detection and confirmation in equine samples, using EDTA to inhibit analyte degradation between the time of collection and analysis. Opiorphin was extracted by weak cation exchange followed by analysis using HILIC-MS/MS. The method was validated and the LOD was determined to b...
Wong JKY, Kwok WH, Chan GHM, Choi TLS, Ho ENM, Jaubert M, Bailly-Chouriberry L, Bonnaire Y, Cawley A, Ming Williams H, Keledjian J, Brooks L....Acadesine, 5-aminoimidazole-4-carboxamide-1-β-D-ribofuranoside, commonly known as AICAR, is a naturally occurring adenosine monophosphate-activated protein kinase (AMPK) activator in many mammals, including humans and horses. AICAR has attracted considerable attention recently in the field of doping control because of a study showing the enhancement of endurance performance in unexercised or untrained mice, resulting in the term 'exercise pill'. Its use has been classified as gene doping by the World Anti-Doping Agency (WADA), and since it is endogenous, it may only be possible to control del...
Skrabalak DS, Henion JD.Betamethasone and its major unconjugated metabolite, 6-beta-hydroxybetamethasone, were detected in equine urine by thin-layer chromatography and characterized by micro-liquid chromatography/mass spectrometry (micro-LC/MS). Their structures were confirmed by a combination of infrared spectroscopy and nuclear magnetic resonance spectroscopy.
Ho EN, Chan GH, Wan TS, Curl P, Riggs CM, Hurley MJ, Sykes D.Cobalt is a well-established inducer of hypoxia-like responses, which can cause gene modulation at the hypoxia inducible factor pathway to induce erythropoietin transcription. Cobalt salts are orally active, inexpensive, and easily accessible. It is an attractive blood doping agent for enhancing aerobic performance. Indeed, recent intelligence and investigations have confirmed cobalt was being abused in equine sports. In this paper, population surveys of total cobalt in raceday samples were conducted using inductively coupled plasma mass spectrometry (ICP-MS). Urinary threshold of 75 ng/mL a...
Snyder JR, Pascoe JR, Hietala SK, Holland M, Baggot DJ.Gentamicin sulfate (2.2 mg/kg of body weight, IV) was given to anesthetized horses. Jejunal and large colon tissue samples (1 g), serum, and urine were collected over a 4-hour period. Maximum gentamicin concentrations in serum (10.06 +/- 2.85 micrograms/ml) occurred at 0.25 hours after injection. Maximum gentamicin concentrations in the large colon (4.13 +/- 1.80 micrograms/ml) and jejunum (2.26 +/- 1.35 micrograms/ml) occurred in horses at 0.5 and 0.33 hours, respectively. Tissue concentrations decreased in parallel with serum concentrations and were still detectable at the end of the 4-hour ...
Brooks CL, Garry F, Swartout MS.Analytical characteristics of photometry and ion-specific potentiometry for urine from sheep, horses, cows, dogs, and cats were determined, using solutions of sodium and potassium chloride. The performance of both methods were acceptable, but the ion-specific potentiometer (in the mode for urine analysis) was superior in terms of linearity of response and correlation between actual vs measured concentrations. Coefficients of variation of either method for repeated analyses of various concentrations of sodium and potassium were always less than 2.5%. The measurement of sodium concentration in u...
Bochnia M, Sander J, Ziegler J, Terhardt M, Sander S, Janzen N, Cavalleri JV, Zuraw A, Wensch-Dorendorf M, Zeyner A.Atypical myopathy (AM) in horses is caused by ingestion of seeds of the Acer species (Sapindaceae family). Methylenecyclopropylacetyl-CoA (MCPA-CoA), derived from hypoglycin A (HGA), is currently the only active toxin in Acer pseudoplatanus or Acer negundo seeds related to AM outbreaks. However, seeds or arils of various Sapindaceae (e.g., ackee, lychee, mamoncillo, longan fruit) also contain methylenecyclopropylglycine (MCPG), which is a structural analogue of HGA that can cause hypoglycaemic encephalopathy in humans. The active poison formed from MCPG is methylenecyclopropylformyl-CoA (MCPF-...
Ishii H, Shibuya M, Leung GN, Yamashita S, Nagata SI, Kushiro A, Sakai S, Toju K, Okada J, Kawasaki K, Kusano K, Kijima-Suda I.For the purpose of doping control, this is the first report of accurate quantification of four critical structural isomers of nicotine metabolites (trans-3'-hydroxycotinine, cis-3'-hydroxycotinine, 5'-hydroxycotinine, and N'-hydroxymethylnorcotinine) in equine plasma and urine for the establishment of their elimination profiles. Besides, the pharmacokinetic studies of trans-3'-hydroxycotinine and N'-hydroxymethylnorcotinine in equine plasma and urine are also presented for the first time. Methods: The accurate quantification methods of the aforementioned four structural isomers in horse plasma...
Dehennin L, Petit E, Bonnaire Y, Bruyas JF, Le Bizec B, Plou P.Rules of horse racing stipulate that pregnant mares may compete under definite conditions of date, because early pregnant status may be misused for the sake of enhancing physical performance by putative anabolic steroid action. Screening for pregnancy is generally performed by plasma equine gonadotrophin (eCG) immunoassay, which covers the period between Days 40 and 120. In common screening for urinary anabolic steroids performed by gas chromatography-mass spectrometry, inclusion of two complementary criteria, i.e. the evaluation of total conjugates of 5(10)-estrene-3beta,17alpha-diol (EED) an...
Takeda A, Shinohara T.A simple method for the simultaneous analysis of tiaramide (TRA) metabolites in the horse is described. The sample preparation method using a Bond-Elut PH cartridge and stepwise elution with ice-cold, 30% aqueous methanol followed by additional methanol is effective for recovering the metabolites with different properties. The extraction method gives good recoveries (greater than 80%) and reproducibility. Each metabolite is well separated by high-performance liquid chromatography using an octadecyl-type column of polymer-based packing with a solvent system of 20 mM phosphate buffer (pH 6.5)-ac...