Analyze Diet

Topic:Biomechanics

Biomechanics in horses refers to the study of the mechanical principles that govern movement and physical function in equine species. This field encompasses the analysis of gait, locomotion, and the forces exerted by and upon the horse's musculoskeletal system. Biomechanical studies often involve the use of motion capture technology, force plates, and computer modeling to assess how horses move and how various factors, such as conformation, training, and health status, influence their performance and soundness. Research in equine biomechanics contributes to understanding injury prevention, rehabilitation, and performance optimization. This page compiles peer-reviewed research studies and scholarly articles that explore the mechanics of movement, the impact of external and internal forces, and the applications of biomechanical analysis in equine care and management.
Detection of small tendon lesions by sonoelastographic visualization of strain profile differences: initial experiences.
Skeletal radiology    January 5, 2012   Volume 41, Issue 9 1073-1079 doi: 10.1007/s00256-011-1349-2
Buck AR, Verstraete N, Li Y, Schweizer A, Snedeker JG, Buck FM.To assess the capability of a commercial sonoelastography system to detect small tendon lesions by quantitative analysis of elastogram profiles. Methods: Strips of equine digital flexor tendons were used to model small human tendons. Two tendons were examined. From each tendon, six unmodified tendon strips (controls) and six tendon strips with a central defect of the same tendons were compared. The tendon strips were placed under a physiological tensile strain of 5%. Sonoelastographic visualization of the strain profile was performed. Regions of interest (ROI) were defined left and right of th...
Comparison of pressure distribution under a conventional saddle and a treeless saddle at sitting trot.
Veterinary journal (London, England : 1997)    December 16, 2011   Volume 193, Issue 1 87-91 doi: 10.1016/j.tvjl.2011.11.017
Belock B, Kaiser LJ, Lavagnino M, Clayton HM.It can be a challenge to find a conventional saddle that is a good fit for both horse and rider. An increasing number of riders are purchasing treeless saddles because they are thought to fit a wider range of equine back shapes, but there is only limited research to support this theory. The objective of this study was to compare the total force and pressure distribution patterns on the horse's back with conventional and treeless saddles. The experimental hypotheses were that the conventional saddle would distribute the force over a larger area with lower mean and maximal pressures than the tre...
Stifle extension results in differential tensile forces developing between abaxial and axial components of the cranial meniscotibial ligament of the equine medial meniscus: a mechanistic explanation for meniscal tear patterns.
Equine veterinary journal    December 14, 2011   Volume 44, Issue 5 554-558 doi: 10.1111/j.2042-3306.2011.00532.x
Fowlie JG, Arnoczky SP, Lavagnino M, Stick JA.To identify potential functional-anatomical characteristics of the cranial horn attachment of the medial meniscus (MM) that may help explain the pathogenesis of the common tear patterns that have been reported. Objective: Full extension of the stifle generates a significant increase in tensile forces within the cranial meniscotibial ligament (CrMTL) of the MM, which may predispose this structure to injury. Methods: The effect of femorotibial angle (160°, 150°, 140° and 130°) on tensile forces in the axial and abaxial components of the CrMTL was examined in 6 mature cadaver stifles using an...
Short-term cast immobilisation is effective in reducing lesion propagation in a surgical model of equine superficial digital flexor tendon injury.
Equine veterinary journal    December 5, 2011   Volume 44, Issue 5 570-575 doi: 10.1111/j.2042-3306.2011.00513.x
David F, Cadby J, Bosch G, Brama P, van Weeren R, van Schie H.Larger superficial digital flexor tendon (SDFT) injuries have a poorer prognosis than smaller lesions. During the inflammatory phase enlargement of the initial lesion is frequently noted, with biomechanical loading being recently proposed to play an important role. Objective: To evaluate the effect of lower limb cast immobilisation on tendon lesion propagation in an equine model of surgically induced SDFT injury. Methods: Core lesions were surgically induced in both front SDFTs of 6 young mature horses. At the end of surgery, one leg was randomly placed in a lower limb cast and the other leg (...
Concerted and adaptive alignment of decorin dermatan sulfate filaments in the graded organization of collagen fibrils in the equine superficial digital flexor tendon.
Journal of anatomy    November 28, 2011   Volume 220, Issue 2 156-163 doi: 10.1111/j.1469-7580.2011.01456.x
Watanabe T, Imamura Y, Suzuki D, Hosaka Y, Ueda H, Hiramatsu K, Takehana K.The equine superficial digital flexor tendon (SDFT) has a graded distribution of collagen fibril diameters, with predominantly small-diameter fibrils in the region of the myotendinous junction (MTJ), a gradual increase in large-diameter fibrils toward the osteotendinous junction (OTJ), and a mixture of small- and large-diameter fibrils in the middle metacarpal (MM) region. In this study, we investigated the ultrastructure of the SDFT, to correlate the spatial relationship of the collagen fibrils with the graded distribution. The surface-to-surface distances of pairs of fibrils were found to be...
First application of axial speed of sound to follow up injured equine tendons.
Ultrasound in medicine & biology    November 21, 2011   Volume 38, Issue 1 162-167 doi: 10.1016/j.ultrasmedbio.2011.10.008
Vergari C, Pourcelot P, Ravary-Plumioën B, Dupays AG, Denoix JM, Mitton D, Laugier P, Crevier-Denoix N.Ultrasonography is an established technique to follow up injured tendons, although the lesions' echogenicity tends to become normal before the tendon is ready to sustain the stresses imposed by exercise. Normalized axial speed of sound (SOS) has been found to correlate with an injured tendon's stiffness; therefore, the purpose of this study was to establish whether SOS would be a useful tool in tendon injury follow-up. Axial SOS was measured in 11 equine superficial digital flexor tendons during a 15-week follow-up period and compared with an ultrasonographic grading system. SOS significantly ...
Vertical head and trunk movement adaptations of sound horses trotting in a circle on a hard surface.
Veterinary journal (London, England : 1997)    November 21, 2011   Volume 193, Issue 1 73-80 doi: 10.1016/j.tvjl.2011.10.019
Starke SD, Willems E, May SA, Pfau T.Trotting a horse in circles is a standard and important part of the subjective equine lameness examination, yet objective data on this form of locomotion are sparse. The aim of this study was to investigate the effect of trotting in a circle on head and trunk movement symmetry. Vertical movements of the head, withers, os sacrum and left and right tuber coxae were measured using inertial sensors as 12 sound horses were trotted on a hard surface in a straight line and in a circle on both reins. Seven asymmetry measures and hip hike were calculated for each horse for at least nine strides of comp...
Stirrup forces during horse riding: a comparison between sitting and rising trot.
Veterinary journal (London, England : 1997)    November 18, 2011   Volume 193, Issue 1 193-198 doi: 10.1016/j.tvjl.2011.10.007
van Beek FE, de Cocq P, Timmerman M, Muller M.Injuries of horses might be related to the force the rider exerts on the horse. To better understand the loading of the horse by a rider, a sensor was developed to measure the force exerted by the rider on the stirrups. In the study, five horses and 23 riders participated. Stirrup forces measured in sitting trot and rising trot were synchronised with rider movements measured from digital films and made dimensionless by dividing them by the bodyweight (BW) of the rider. A Fourier transform of the stirrup force data showed that the signals of both sitting and rising trot contained 2.4 and 4.8 Hz...
Gait analysis using 3D accelerometry in horses sedated with xylazine.
Veterinary journal (London, England : 1997)    November 13, 2011   Volume 193, Issue 1 212-216 doi: 10.1016/j.tvjl.2011.10.012
López-Sanromán FJ, Holmbak-Petersen R, Santiago I, Gómez de Segura IA, Barrey E.The aim of the present study was to verify the efficacy and sensitivity of an accelerometric device in detecting and quantifying the degree of movement alteration produced in horses sedated with xylazine. Horses (n=6) were randomly administered either xylazine or a control by intravenous injection, with at least 1 week between each treatment. A triaxial accelerometric device was used for the accelerometric gait assessment 15 min before (baseline) and 5, 15, 30, 45, 60, 75, 90, 105 and 120 min after each treatment. Eight different accelerometric parameters were calculated, including speed, stri...
Axial speed of sound is related to tendon’s nonlinear elasticity.
Journal of biomechanics    November 10, 2011   Volume 45, Issue 2 263-268 doi: 10.1016/j.jbiomech.2011.10.032
Vergari C, Ravary-Plumioën B, Evrard D, Laugier P, Mitton D, Pourcelot P, Crevier-Denoix N.Axial speed of sound (SOS) measurements have been successfully applied to noninvasively evaluate tendon load, while preliminary studies showed that this technique also has a potential clinical interest in the follow up of tendon injuries. The ultrasound propagation theory predicts that the SOS is determined by the effective stiffness, mass density and Poisson's ratio of the propagating medium. Tendon stiffness characterizes the tissue's mechanical quality, but it is often measured in quasi-static condition and for entire tendon segments, so it might not be the same as the effective stiffness w...
[Influence of exercise on horses’ limb volume, measured by an optoelectronic device].
Berliner und Munchener tierarztliche Wochenschrift    November 9, 2011   Volume 124, Issue 5-6 257-264 
Siewert C, Böttcher A, Hellige M, Beyerbach M, von Rautenfeld DB, Seifert H.This study tested for the first time an optoelectronic device (Perometer*) measuring limb volume of horses. An analysis of its application was performed regarding the influence of different types of physical exercise on the volume of the extremities. 40 horses were divided into four groups often horses, each group being exposed to exercise, differing in kind and duration of lunging, horse-ridden and riderless. The volume measurement was performed by determining the inactive value (I) after a twelfe-hour standing period, the load value (II) immediately after exercise and recovery value (III) on...
Therapeutic effects of a horse riding simulator in children with cerebral palsy.
Arquivos de neuro-psiquiatria    November 2, 2011   Volume 69, Issue 5 799-804 doi: 10.1590/s0004-282x2011000600014
Silva e Borges MB, Werneck MJ, da Silva Mde L, Gandolfi L, Pratesi R.To evaluate the efficacy of horse ridding simulator on the sitting postural control of children with spastic diplegia. Methods: Forty children were randomly divided in a group using the simulator (RS) and a group performing conventional physical therapy (CT). FScan/Fmat equipment was used to register maximal displacement in antero-posterior (AP) and medio-lateral (ML) directions with children in sitting position. At the pre and post intervention stage both groups were classified according to the Gross Motor Function Classification System (GMFCS) and, after intervention, by the AUQEI questionna...
Biomechanical testing of a novel suture pattern for repair of equine tendon lacerations.
Veterinary surgery : VS    October 31, 2011   Volume 41, Issue 2 278-285 doi: 10.1111/j.1532-950X.2011.00905.x
Everett E, Barrett JG, Morelli J, DeVita R.To compare in vitro biomechanical properties of a novel suture pattern to a current standard for primary repair of equine superficial digital flexor tendon (SDFT) laceration. Methods: In vitro randomized, paired design. Methods: Cadaveric equine forelimb SDFT (n = 24). Methods: The 3-loop pulley (3LP) and 6-strand Savage (SSS) suture patterns were applied to transected equine SDFT. Ultimate failure load, stiffness, mode of failure, and load required to form a 3-mm gap were obtained using a materials testing system and synchronized high-speed video analysis. Statistical comparisons were made us...
Radiographic evaluation of changes in the proximal phalanx of Thoroughbreds in race training.
American journal of veterinary research    October 26, 2011   Volume 72, Issue 11 1482-1488 doi: 10.2460/ajvr.72.11.1482
Beccati F, Pepe M, Di Meo A, Davanzo S, Moriconi F.To evaluate changes in the cortical bone of the proximal phalanx of the fore-limbs of Thoroughbreds in response to training. Methods: Twenty-seven 2-year-old Thoroughbreds (20 females, 2 males, and 5 geldings). Methods: Horses were principally in training for races in a straight line and in a clockwise direction. Lateromedial and dorsopalmar radiographic views of each metacarpophalangeal joint were obtained before the horses started training and 1 year after starting exercise and racing. Width of the dorsal, palmar, lateral, and medial cortex and the width and thickness of the medulla were mea...
Evaluation of biomechanical effects of four stimulation devices placed on the hind feet of trotting horses.
American journal of veterinary research    October 26, 2011   Volume 72, Issue 11 1489-1495 doi: 10.2460/ajvr.72.11.1489
Clayton HM, Lavagnino M, Kaiser LJ, Stubbs NC.To compare effects of 4 types of stimulation devices attached to the hind feet on hoof flight, joint angles, and net joint powers of trotting horses. Methods: 8 clinically normal horses. Methods: Horses were evaluated under 5 conditions in random order: no stimulators, loose straps (10 g), lightweight tactile stimulators (55 g), limb weights (700 g), and limb weights with tactile stimulators (700 g). Reflective markers on the hind limbs were tracked during the swing phase of 6 trotting trials performed at consistent speed to determine peak hoof heights and flexion angles of the hip, stifle, ta...
Axial speed of sound for the monitoring of injured equine tendons: a preliminary study.
Journal of biomechanics    October 22, 2011   Volume 45, Issue 1 53-58 doi: 10.1016/j.jbiomech.2011.10.016
Vergari C, Pourcelot P, Ravary-Plumioën B, Dupays AG, Jacquet S, Audigié F, Denoix JM, Laugier P, Mitton D, Crevier-Denoix N.Equine superficial digital flexor tendons (SDFT) are often injured, and they represent an excellent model for human sport tendinopathies. While lesions can be precisely diagnosed by clinical evaluation and ultrasonography, a prognosis is often difficult to establish; the knowledge of the injured tendon's mechanical properties would help in anticipating the outcome. The objectives of the present study were to compare the axial speed of sound (SOS) measured in vivo in normal and injured tendons and to investigate their relationship with the tendons' mechanical parameters, in order to assess the ...
Morphometrical variations of the carpal bones in thoroughbreds and ponies.
Anatomia, histologia, embryologia    October 20, 2011   Volume 41, Issue 2 139-148 doi: 10.1111/j.1439-0264.2011.01114.x
Abdunnabi AH, Ahmed YA, Philip CJ, Davies HM.There is scant morphological data for equine carpal bones despite the frequent pathology in Thoroughbreds (TB). This study aimed to identify morphological and morphometrical variations and similarities in carpal bones between and within TB and Ponies (Po). Carpal bones from nine TB and 13 Po were prepared by boiling and drying. Lateromedial width, dorsopalmar depth, proximodistal height, relative density and volume of each bone were measured. Normalized measurements of the radial (Cr) and third (C3) carpal bones were significantly different in all dimensions, and there were significant variati...
Relationships between in vivo microdamage and the remarkable regional material and strain heterogeneity of cortical bone of adult deer, elk, sheep and horse calcanei.
Journal of anatomy    September 26, 2011   Volume 219, Issue 6 722-733 doi: 10.1111/j.1469-7580.2011.01428.x
Skedros JG, Sybrowsky CL, Anderson WE, Chow F.Natural loading of the calcanei of deer, elk, sheep and horses produces marked regional differences in prevalent/predominant strain modes: compression in the dorsal cortex, shear in medial-lateral cortices, and tension/shear in the plantar cortex. This consistent non-uniform strain distribution is useful for investigating mechanisms that mediate the development of the remarkable regional material variations of these bones (e.g. collagen orientation, mineralization, remodeling rates and secondary osteon morphotypes, size and population density). Regional differences in strain-mode-specific micr...
Resection of Grade III cranial horn tears of the equine medial meniscus alter the contact forces on medial tibial condyle at full extension: an in-vitro cadaveric study.
Veterinary surgery : VS    September 23, 2011   Volume 40, Issue 8 957-965 doi: 10.1111/j.1532-950X.2011.00899.x
Fowlie J, Arnoczky S, Lavagnino M, Maerz T, Stick J.To evaluate the magnitude and distribution of joint contact pressure on the medial tibial condyle after grade III cranial horn tears of the medial meniscus. Methods: Experimental study. Methods: Cadaveric equine stifles (n = 6). Methods: Cadaveric stifles were mounted in a materials testing system and electronic pressure sensors were placed between the medial tibial condyle and medial meniscus. Specimens were loaded parallel to the longitudinal axis of the tibia to 1800 N at 130°, 140°, 150°, and 160° stifle angle. Peak pressure and contact area were recorded from the contact maps. Testing...
Movement associated reduction of spatial capacity of the equine cervical vertebral canal.
Veterinary journal (London, England : 1997)    September 14, 2011   Volume 192, Issue 3 525-528 doi: 10.1016/j.tvjl.2011.08.011
Schmidburg I, Pagger H, Zsoldos RR, Mehnen J, Peham C, Licka TF.Laterolateral radiographs of equine necks are reported to be inaccurate in determining the site of spinal cord lesions even when a myelogram is carried out. The goal of this study was to assess constrictions present in the cervical vertebral canal at any time point throughout the extremes of movement. Sixteen equine cervical vertebral columns without history of cervical disease were used. After removal of the spinal cord, the dura mater was filled with polyurethane foam and during its plastic phase the cervical vertebral column was passively moved in flexion-extension, lateral bending and 30°...
Assessment of repeatability of a wireless, inertial sensor-based lameness evaluation system for horses.
American journal of veterinary research    September 2, 2011   Volume 72, Issue 9 1156-1163 doi: 10.2460/ajvr.72.9.1156
Keegan KG, Kramer J, Yonezawa Y, Maki H, Pai PF, Dent EV, Kellerman TE, Wilson DA, Reed SK.To determine repeatability of a wireless, inertial sensor-based lameness evaluation system in horses. Methods: 236 horses. Methods: Horses were from 2 to 29 years of age and of various breeds and lameness disposition. All horses were instrumented with a wireless, inertial sensor-based motion analysis system on the head (accelerometer), pelvis (midline croup region [accelerometer]), and right forelimb (gyroscope) before evaluation in 2 consecutive trials, approximately 5 minutes apart, as the horse was trotted in a straight line. Signal-processing algorithms generated overall trial asymmetry me...
Propagation of two longitudinal waves in a cancellous bone with the closed pore boundary.
The Journal of the Acoustical Society of America    September 1, 2011   Volume 130, Issue 2 EL122-EL127 doi: 10.1121/1.3607196
Mizuno K, Nagatani Y, Yamashita K, Matsukawa M.Ultrasound propagation in cancellous bone (porous media) under the condition of closed pore boundaries was investigated. A cancellous bone and two plate-like cortical bones obtained from a racehorse were prepared. A water-immersion ultrasound technique in the MHz range and a three-dimensional elastic finite-difference time-domain (FDTD) method were used to investigate the waves. The experiments and simulations showed a clear separation of the incident longitudinal wave into fast and slow waves. The findings advance the evaluation of bones based on the two-wave phenomenon for in vivo assessment...
Is a single force plate adequate for stabilographic analysis in horses?
Equine veterinary journal    August 26, 2011   Volume 44, Issue 5 550-553 doi: 10.1111/j.2042-3306.2011.00458.x
Clayton HM, Nauwelaerts S.Postural balance can be quantified using stabilographic variables derived from force plate data that describe movements of the horse's centre of pressure (COP) in the horizontal plane. Most force plates are not large enough to accommodate all 4 limbs of a standing horse, so the study was designed to assess whether representative stabilographic data could be collected from the forelimbs or hindlimbs. Objective: To determine whether stabilographic data from either the forelimbs or the hindlimbs were representative of data for the total body. Methods: Stabilographic data (960 Hz) were collected...
Possible role of carpal hyperextension in superficial digital flexor tendinopathy.
Equine veterinary journal    August 26, 2011   Volume 44, Issue 5 559-563 doi: 10.1111/j.2042-3306.2011.00466.x
Whitlock D, Garcia TC, Vallance SA, Stover SM.The specific biomechanical circumstances that induce excessive superficial digital flexor tendon (SDFT) strain in horses are unknown. Objective: Carpal joint hyperextension during axial limb loading during the middle of stance disproportionately enhances SDFT strains compared to suspensory ligament (SL) strains. Methods: Superficial digital flexor tendon and SL strains were measured in 7 cadaver limbs during in vitro loading that maintained carpal extension or allowed carpal hyperextension by constraining, or allowing rotation of, the radius during loading conditions that simulated the middle ...
Proceedings of the 8th International Conference on Equine Exercise Physiology. November 7-12, 2010. Cape Town, South Africa.
Equine veterinary journal. Supplement    August 19, 2011   Issue 38 1-702 
No abstract available
The effect of previous conditioning exercise on diaphyseal and metaphyseal bone to imposition and withdrawal of training in young Thoroughbred horses.
Veterinary journal (London, England : 1997)    August 19, 2011   Volume 192, Issue 1 34-40 doi: 10.1016/j.tvjl.2011.05.016
Firth EC, Rogers CW, van Weeren PR, Barneveld A, McIlwraith CW, Kawcak CE, Goodship AE, Smith RK.This study recorded the response to training of the diaphysis of the proximal phalangeal bone and the third metacarpal bone (Mc3) and the Mc3 proximal metaphysis. Nineteen 2- and 3-year old horses in training were exposed either to spontaneous exercise at pasture (PASTEX group) or additional imposed exercise (CONDEX group) from a very young age. Quantitative computed tomography scans were analysed for bone mineral content, size, bone mineral density, periosteal and endosteal circumference, cortical thickness and an estimate of bone strength. The bones of the CONDEX horses were bigger and stron...
In vitro electrical activity of the equine pelvic flexure.
Equine veterinary journal. Supplement    August 4, 2011   Issue 39 145-148 doi: 10.1111/j.2042-3306.2011.00396.x
Fintl C, Pearson GT, Mayhew IG, Hudson NP.The generation and maintenance of intestinal motility patterns involve the complex interactions of several components including the gastrointestinal pacemaker cells (interstitial cells of Cajal, ICC). Central to ICC function is the generation of rhythmic pacemaker currents, namely slow waves, which represent the rate limiting step for intestinal smooth muscle contractions. Currently, intracellular slow wave activity has not been demonstrated in the equine colon. Objective: To characterise the in vitro myoelectrical activity of the equine pelvic flexure using intracellular recording techniques....
Method to calibrate phase fluctuation in polarization-sensitive swept-source optical coherence tomography.
Journal of biomedical optics    August 3, 2011   Volume 16, Issue 7 070502 doi: 10.1117/1.3597721
Lu Z, Kasaragod DK, Matcher SJ.We present a phase fluctuation calibration method for polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) using continuous polarization modulation. The method uses a low-voltage broadband polarization modulator driven by a synchronized sinusoidal burst waveform rather than an asynchronous waveform, together with the removal of the global phases of the measured Jones matrices by the use of matrix normalization. This makes it possible to average the measured Jones matrices to remove the artifact due to the speckle noise of the signal in the sample without introducing aux...
A cryogenic clamping technique that facilitates ultimate tensile strength determinations in tendons and ligaments.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    July 21, 2011   Volume 24, Issue 5 370-373 doi: 10.3415/VCOT-10-09-0128
Bowser JE, Elder SH, Rashmir-Raven AM, Swiderski CE.To describe the use of a cryogenic clamp of novel design for tensile strength testing of tendinous and ligamentous tissues with inherently high tensile strength. Methods: Inexpensive, easily machined steel clamps were manufactured to facilitate rapid insertion into a standard wedge-screw grip apparatus installed on a testing system with a control system attached. The deep digital flexor tendon (DDFT) of six horses was trimmed to a uniform dumbbell shape and secured in clamps using partial submersion in liquid nitrogen for approximately 45 seconds and immediately tested. Approximate time betwee...
An ex vivo biomechanical study comparing strength characteristics of a new technique with the three-loop pulley for equine tenorrhaphy.
Veterinary surgery : VS    July 19, 2011   Volume 40, Issue 6 768-773 doi: 10.1111/j.1532-950X.2011.00856.x
Smith RL, Murphy DJ, Day RE, Lester GD.To test single cycle to failure tensile strength characteristics of 6 suture material-pattern combinations in equine superficial digital flexor (SDF) tenorrhaphy, specifically to compare a 10-strand modification of the Savage core suture technique with the 3-loop pulley technique. Methods: Ex vivo mechanical experiment comparing 3 different suture patterns with 2 different materials. Methods: Forelimb and hindlimb SDF tendons (n=48) harvested from adult Thoroughbred and Standardbred horses of mixed age and gender. Methods: Six suture material-pattern combinations were evaluated: (1) 10-strand ...
1 38 39 40 41 42 86