Analyze Diet

Topic:Cadaver Study

Cadaver studies involving horses provide valuable insights into equine anatomy, pathology, and surgical techniques. These studies involve the examination and dissection of deceased horses to better understand the structure and function of various bodily systems. By utilizing cadavers, researchers and veterinary students can gain hands-on experience in identifying anatomical features, understanding disease processes, and refining surgical skills without the ethical concerns associated with live animal experimentation. Cadaver studies also contribute to the development of new diagnostic and therapeutic approaches by allowing for detailed exploration of equine anatomy and pathology. This page compiles peer-reviewed research studies and scholarly articles that explore the methodologies, findings, and applications of cadaver studies in equine science.
Evaluation of a standardised radiographic technique of the equine hoof.
Schweizer Archiv fur Tierheilkunde    December 8, 2004   Volume 146, Issue 11 507-514 doi: 10.1024/0036-7281.146.11.507
Kummer M, Lischer C, Ohlerth S, Vargas J, Auer J.Radiography of the equine hoof is often used to obtain a diagnosis. Quantitative interpretation, especially for research purposes requires high quality and accuracy of radiographs. The purpose of this study was to describe and evaluate a radiographic technique for the lateromedial (LM) and the dorsopalmar (DP) view of the equine hoof. Ten radiographs for each view from one cadaver limb and from both front feet in a standing horse were taken in order to assess repeatability of the radiographic technique. The method requires easy to use adjustable and portable equipment and strictly defined exte...
The displaced equine soft palate as a source of abnormal respiratory noise during expiration.
Equine veterinary journal    December 8, 2004   Volume 36, Issue 7 590-594 doi: 10.2746/0425164044864453
Franklin SH, Price C, Burn JF.To develop the technique of respiratory sound analysis for the diagnosis of dorsal displacement of the equine soft palate. Objective: To show that 1) the displaced soft palate can spontaneously vibrate in the presence of expiratory airflow; 2) the observed frequency of vibration can be detected in respiratory sound recordings; and 3) the frequency of vibrations measured in cadaveric specimens are similar to those obtained from audio spectra in exercising horses with DDSP. Methods: Palatal movements and respiratory sounds were recorded from artificially ventilated cadaveric heads. The fundament...
Effects of injury to the suspensory apparatus, exercise, and horseshoe characteristics on the risk of lateral condylar fracture and suspensory apparatus failure in forelimbs of thoroughbred racehorses.
American journal of veterinary research    November 30, 2004   Volume 65, Issue 11 1508-1517 doi: 10.2460/ajvr.2004.65.1508
Hill AE, Gardner IA, Carpenter TE, Stover SM.To assess concurrently the effects of moderate ligamentous suspensory apparatus injury (MLSAI), racing-speed exercise, and horseshoe characteristics on risk of catastrophic suspensory apparatus failure (SAF) or metacarpal condylar fracture (CDY) in forelimbs of racehorses. Methods: Cadavers of 301 Thoroughbred racehorses (108 with SAF, 33 with CDY and 160 control horses). Methods: A cross-sectional epidemiologic study was used to describe distributions and relationships between MLSAI, exercise, and horseshoe variables. Logistic regression was used to assess potential risk factors for developin...
Use of computed tomography angiography to evaluate the vascular anatomy of the distal portion of the forelimb of horses.
American journal of veterinary research    November 5, 2004   Volume 65, Issue 10 1409-1420 doi: 10.2460/ajvr.2004.65.1409
Collins JN, Galuppo LD, Thomas HL, Wisner ER, Hornof WJ.To provide a detailed description of the vascular anatomy of the distal portion of the forelimbs of horses by use of computed tomography angiography (CTA). Methods: 6 forelimbs of 5 horses and 1 forelimb from an equine cadaver; none of the horses had orthopedic or vascular disease. Methods: Horses were anesthetized and CTA was conducted on the dependent forelimb. A catheter was inserted in the median artery, and contrast medium was infused at a rate of 3 mL/s. A computed tomography (CT) scanner was used to obtain contiguous slices from the region of the proximal sesamoid bones to the toe. All ...
Ultrasonography of the medial palmar intercarpal ligament in the Thoroughbred: technique and normal appearance.
Equine veterinary journal    July 16, 2004   Volume 36, Issue 5 402-408 doi: 10.2746/0425164044868459
Driver AJ, Barr FJ, Fuller CJ, Barr AR.Tearing of the medial palmar intercarpal ligament (MPICL) has been recognised as a cause of lameness in the Thoroughbred, but diagnosis is difficult due to the nonspecific clinical signs, and can be achieved only by performing arthroscopy on the mid carpal joint (MCJ). It would be beneficial to be able to image the MPICL using ultrasonography to determine whether pathology is present in the ligament in order to aid diagnosis and prognosis. Objective: To determine whether the MPICL could be imaged using ultrasound from the dorsal aspect of the MCJ, and to describe the technique and normal ultra...
Magnetic resonance imaging of the palmar aspect of the equine podotrochlear apparatus: normal appearance. Busoni V, Snaps F, Trenteseaux J, Dondelinger RF.The purpose of this study was to describe the normal magnetic resonance (MR) imaging characteristics of the palmar structures of the equine podotrochlear apparatus by means of retrospective evaluation of MR imaging studies of 16 cadaver limbs. The articular aspect of the distal sesamoid bone was not evaluated in this study. Equine digits were imaged with a human knee radiofrequency coil in a 1.5 T magnetic field, using spin echo (SE) T1-weighted, turbo spin echo proton density (TSE PD)-weighted with and without fat saturation (FS), and FS TSE T2-weighted sequences. The limbs were dissected aft...
Quantitative evaluation of equine deep digital flexor tendon morphology using magnetic resonance imaging. Murray RC, Roberts BL, Schramme MC, Dyson SJ, Branch M.Injury of the distal aspect of the deep digital flexor tendon (DDFT) is a recognized cause of lameness, but diagnosis is difficult. This study aimed to improve understanding of DDFT morphology and pathology using retrospective evaluation of magnetic resonance (MR) images. We hypothesized that: (1) The distal aspect of the DDFT in normal horses would have a repeatable proximal/distal pattern and symmetry between limbs and between lobes; (2) DDFT dimensions would be related to bodyweight, navicular bone dimensions and hoof size; (3) this symmetry and pattern would be lost in DDFT injury; and (4)...
Determination of passive mechanical properties of the superficial and deep digital flexor muscle-ligament-tendon complexes in the forelimbs of horses.
American journal of veterinary research    February 21, 2004   Volume 65, Issue 2 188-197 doi: 10.2460/ajvr.2004.65.188
Swanstrom MD, Stover SM, Hubbard M, Hawkins DA.To determine the relative contributions of the muscles, tendons, and accessory ligaments to the passive force-length properties of the superficial (SDF) and deep digital flexor (DDF) myotendinous complexes. Methods: 8 cadaveric forelimbs from 6 adult Thoroughbreds. Methods: In vitro, limb configurations during slack position and myotendinous lengths during subsequent axial loading of forelimbs were recorded before and after transection of accessory ligaments. Expressions were derived to describe the force-length behavior of each muscle, tendon, and accessory ligament-tendon unit; linear stiffn...
Magnetic resonance imaging of the equine digit with chronic laminitis. Murray RC, Dyson SJ, Schramme MC, Branch M, Woods S.Chronic laminitis is a severe disease affecting the equine digit. It was hypothesized that magnetic resonance (MR) imaging would improve visualization of structures within the foot and pathology associated with chronic laminitis. This study aimed to describe the MR imaging findings in chronic laminitis, compare different pulse sequences for visualization of pathology, and to compare MR imaging with standard radiography. Twenty (10 forelimb, 10 hindlimb) cadaver limbs from 10 horses clinically diagnosed with chronic laminitis (group L) and 10 limbs without laminitis (group N) were used. Laterom...
An in vitro biomechanical comparison of a prototype intramedullary pin-plate with a dynamic compression plate for equine metacarpophalangeal arthrodesis.
Veterinary surgery : VS    December 23, 2003   Volume 33, Issue 1 83-91 doi: 10.1046/j.1532-950x.2004.04010.x
Sod GA, Martin GS.To compare the biomechanical properties of a prototype intramedullary pin-plate (IMPP) implant specifically designed for equine metacarpophalangeal (MCP) arthrodesis with a dynamic compression plate (DCP) system. Methods: In vitro biomechanical testing of paired cadaveric equine forelimbs with a simulated traumatic disruption of the suspensory apparatus, stabilized by one of two methods for MCP arthrodesis. Methods: Twenty-one pairs of adult equine cadaveric forelimbs. Methods: Each forelimb had the distal sesamoidean ligaments severed to create a disrupted suspensory apparatus. For each forel...
Accuracy of ultrasound-guided intra-articular injection of cervical facet joints in horses: a cadaveric study.
Equine veterinary journal    December 3, 2003   Volume 35, Issue 7 657-661 doi: 10.2746/042516403775696366
Nielsen JV, Berg LC, Thoefnert MB, Thomsen PD.Intra-articular facet joint injection is an established diagnostic procedure in human medicine but there are no reports on its reliability in equine practice. Objective: To investigate the accuracy of ultrasound-guided intra-articular injections of the cervical facet joints and to estimate factors influencing the accuracy. Methods: Sixty injections with blue dye were performed on the facet joints between 2nd and 7th cervical vertebra (C2-C7) on horses subjected to euthanasia for nonorthopaedic reasons. The facet joints were subsequently dissected to verify accuracy of deposition. Results: Seve...
Ex vivo magnetic resonance imaging of the distal row of equine carpal bones: assessment of bone sclerosis and cartilage damage. Anastasiou A, Skioldebrand E, Ekman S, Hall LD.The distal row of carpal bones (C2, C3, and C4) from eight left intercarpal joints--four from Standardbred Trotters and four from Swedish Warmblood horses--were used to assess the potential of magnetic resonance (MR) imaging to detect cartilage and bone lesions. The joints used in the study were classified by macroscopic and radiographic examinations as having normal, mild, moderate, or severe articular cartilage lesions and bone sclerosis. Those classifications correlated well with the appearance of the MR images. Bone sclerosis in the MR images was observed as regions of decreased signal int...
Ultrasonography of peripheral nerves in the normal adult horse. Alexander K, Dobson H.A study of the ultrasonographic appearance and size of the sciatic, tibial, peroneal, suprascapular, radial, median, and ulnar nerves and a comparison with the anatomic size and location of these nerves in the normal adult horse is reported. Cadavers and live horses were studied. Landmarks for localization and techniques for nerve identification are described. The depth and diameter of each nerve at various locations and the success rate in imaging each nerve are reported. Statistically significant correlations were found between anatomically and ultrasonographically measured nerve depths and ...
Geometric symmetry of the solar surface of hooves of thoroughbred racehorses.
American journal of veterinary research    August 21, 2003   Volume 64, Issue 8 1030-1039 doi: 10.2460/ajvr.2003.64.1030
Roland E, Stover SM, Hull ML, Dorsch K.To define a 3-dimensional (3-D) coordinate system with clear definitions of origins and axes relative to hoof anatomic features and determine whether solar surfaces of Thoroughbred racehorse hooves have geometric asymmetry in the mediolateral and dorsopalmar directions. Methods: Left forelimb hooves from 20 Thoroughbred racehorse cadavers. Methods: A right-handed 3-D coordinate axes system centered on the collateral sulci was defined for the left front hoof. Orthogonal distances of anatomic features from the dorsopalmar axis and the plane coincident with the ground were measured and compared b...
Seminal concentrations of trace elements in various animals and their correlations.
Asian journal of andrology    June 5, 2003   Volume 5, Issue 2 101-104 
Massányi P, Trandzik J, Nad P, Toman R, Skalická M, Koréneková B.To determine the seminal concentrations of copper, zinc, iron, cadmium, lead and nickel in bulls, rams, boars, stallions and foxes and study their correlations. Methods: Semen samples were obtained, digested and analyzed by means of the atomic absorption spectrophotometer. Data were analyzed statistically with the Student's t-test and Scheffe's test using PC programs SAS and Excel. Results: The seminal copper concentration was significantly higher in ram [(2.49+/-0.18) mg/kg] and fox [(2.16+/-0.53) mg/kg] than that in bull [(1.64+/-0.21) mg/kg], boar [(1.64+/-0.28) mg/kg] and stallion (0.86 mg...
Tenoscopic release of the equine carpal canal.
Veterinary surgery : VS    June 5, 2003   Volume 32, Issue 3 278-284 doi: 10.1053/jvet.2003.50033
Textor JA, Nixon AJ, Fortier LA.To develop a tenoscopic method to divide the carpal flexor retinaculum and decompress the carpal canal. Methods: Cadaver specimen study and prospective trial. Methods: Twelve cadaveric limbs, 4 clinically normal horses, and 2 clinically affected horses. Methods-A tenoscopic approach to the proximolateral aspect of the carpal sheath was used to identify and facilitate endoscopic division of the inner and outer layers of the carpal flexor retinaculum in cadaver limbs. The technique was further evaluated in 4 normal and 2 clinically affected horses. Results: Anatomic dissection, intraoperative ob...
Cylindrical press-fit osteochondral allografts for resurfacing the equine metatarsophalangeal joint.
Veterinary surgery : VS    June 5, 2003   Volume 32, Issue 3 220-230 doi: 10.1053/jvet.2003.50032
Pearce SG, Hurtig MB, Boure LP, Radcliffe RM, Richardson DW.To investigate the feasibility of resurfacing the equine fetlock joint using cylindrical, orthotopic, press-fit, osteochondral allografts. Methods: Experimental study. Methods: Ten mature, mixed-breed horses. Methods: Cylindrical, osteochondral grafts (6.5-mm diameter) were harvested aseptically from cadaveric equine metatarsophalangeal joints. Allografts were transplanted into 6 horses; 4 horses were sham operated. The surgical approach involved creation of a bone block at the origin of the medial collateral ligament and luxation of the metatarsophalangeal joint. Grafts were placed into the m...
A biomechanical comparison of headless tapered variable pitch and AO cortical bone screws for fixation of a simulated slab fracture in equine third carpal bones.
Veterinary surgery : VS    April 15, 2003   Volume 32, Issue 2 167-177 doi: 10.1053/jvet.2003.50019
Bueno AC, Galuppo LD, Taylor KT, Jensen DG, Stover SM.To compare the mechanical shear strengths and stiffnesses obtained from in vitro testing of a simulated complete third carpal bone (C3) frontal plane radial facet slab fracture (osteotomy) stabilized with either a 4/5 Acutrak (AT) compression screw or a 4.5-mm AO cortical bone (AO) screw inserted in lag fashion. Drilling, tapping, and screw insertion torques, forces, and times also were compared between AT and AO implants. Methods: In vitro biomechanical assessment of site preparation, screw insertion, and shear failure test variables of bone screw stabilized simulated C3 slab fracture in pair...
Moment arms about the carpal and metacarpophalangeal joints for flexor and extensor muscles in equine forelimbs.
American journal of veterinary research    March 29, 2003   Volume 64, Issue 3 351-357 doi: 10.2460/ajvr.2003.64.351
Brown NA, Pandy MG, Buford WL, Kawcak CE, McIlwraith CW.To determine whether muscle moment arms at the carpal and metacarpophalangeal joints can be modeled as fixed-radius pulleys for the range of motion associated with the stance phase of the gait in equine forelimbs. Methods: 4 cadaveric forelimbs from 2 healthy Thoroughbreds. Methods: Thin wire cables were sutured at the musculotendinous junction of 9 forelimb muscles. The cables passed through eyelets at each muscle's origin, wrapped around single-turn potentiometers, and were loaded. Tendon excursions, measured as the changes in lengths of the cables, were recorded during manual rotation of th...
A comparison of ultra-high-molecular weight polyethylene cable and stainless steel wire using two fixation techniques for repair of equine midbody sesamoid fractures: an in vitro biomechanical study.
Veterinary surgery : VS    September 5, 2002   Volume 31, Issue 5 445-454 doi: 10.1053/jvet.2002.34668
Rothaug PG, Boston RC, Richardson DW, Nunamaker DM.To compare the monotonic tensile and fatigue strength of 16-gauge stainless steel wire (SSW) to ultra-high-molecular weight polyethylene (UHMWPE) cable using a transfixed cerclage technique in an in vitro midbody sesamoid osteotomy model. Endoscopic modifications to Martins transfixed cerclage technique were developed. A new suture technique of fixation was compared with the transfixed cerclage technique by measuring gap formation after cyclic testing. Methods: An in vitro biomechanical paired equine cadaver limb study. Methods: Twenty-one paired cadaveric adult equine forelimbs. Methods: Unia...
An in vitro biomechanical investigation of an MP35N intramedullary interlocking nail system for repair of third metacarpal fractures in adult horses.
Veterinary surgery : VS    May 8, 2002   Volume 31, Issue 3 211-225 doi: 10.1053/jvet.2002.32400
Galuppo LD, Stover SM, Aldridge A, Hewes C, Taylor KT.To compare monotonic mechanical properties of gap-ostectomized third metacarpal bones (MC3) stabilized with an MP35N interlocking nail system with contralateral intact bones. Methods: Twenty-four pairs of cadaveric equine MC3s. Methods: Third metacarpal bones were divided into 4 mechanical testing groups (6 pairs per group): compression, palmarodorsal (PD) and mediolateral (ML) 4-point bending, and torsion. One MC3 from each pair was randomly selected as an intact specimen, and the contralateral gap ostectomized bone was stabilized with a 4-hole, 14-mm-diameter, 250-mm-long, MP35N intramedulla...
Arthroscopic anatomy of the equine temporomandibular joint.
Veterinary surgery : VS    November 13, 2001   Volume 30, Issue 6 564-571 doi: 10.1053/jvet.2001.28438
May KA, Moll HD, Howard RD, Pleasant RS, Gregg JM.To develop an arthroscopic approach to, and describe the arthroscopic anatomy of, the equine temporomandibular joint (TMJ). Methods: Cadaveric study, after which the technique was tested in horses. Methods: Ten cadaveric equine heads and 5 normal horses (age, 5-13 years; weight, 425-545 kg). Methods: Specimens or horses were positioned in right lateral recumbency. After fluid distention of the TMJ, arthroscopic portals were made in the dorsal compartment over the most prominent portion of the joint outpouching (caudodorsal approach) and in rostral and intermediate locations. The joint was expl...
Effects of superior check desmotomy on flexor tendon and suspensory ligament strain in equine cadaver limbs.
Veterinary surgery : VS    November 13, 2001   Volume 30, Issue 6 522-527 doi: 10.1053/jvet.2001.28433
Alexander GR, Gibson KT, Day RE, Robertson ID.To measure the effects of transection of the accessory ligament of the superficial digital flexor (SDF) muscle (superior check desmotomy) on flexor tendon and suspensory ligament (SL) strain in vitro. Methods: In vitro experimental biomechanical investigation. ANIMALS USED: Ten equine cadaver forelimbs. Methods: The effects of superior check desmotomy were determined using equine cadaver forelimbs secured in a servocontrolled hydraulic testing machine. Strain sensors were used to measure strain on the superficial and deep digital flexor tendons and SL, and a goniometer was used to measure join...
Laparoscopic surgical technique for repair of rectal and colonic tears in horses: an experimental study.
Veterinary surgery : VS    September 14, 2001   Volume 30, Issue 5 409-416 doi: 10.1053/jvet.2001.25864
Brugmans F, Deegen E.To determine the efficacy of laparoscopic surgical techniques for repair of rectal lacerations in horses. Methods: Experimental study. Methods: Thirty-two segments of equine bowel placed in an equine pelvitrainer, 8 equine cadavers, and 3 normal horses. Methods: In experiment 1, 3 laparoscopic intestinal-repair techniques were evaluated in an equine pelvitrainer: suturing with needle holders, with an automatic suture device, and stapling with a hernia stapler. In experiment 2, descending colon lacerations were sutured laparoscopically using needle holders in a pelvitrainer and in equine cadave...
A biomechanical comparison of headless tapered variable pitch and AO cortical bone screws for fixation of a simulated lateral condylar fracture in equine third metacarpal bones.
Veterinary surgery : VS    July 10, 2001   Volume 30, Issue 4 332-340 doi: 10.1053/jvet.2001.24386
Galuppo LD, Stover SM, Jensen DG, Willits NH.To compare drilling, tapping, and screw-insertion torque, force, and time for the 4.5-mm AO and 6.5-mm Acutrak Plus (AP) bone screws, and to compare the mechanical shear strength and stiffness of a simulated complete lateral condylar fracture of the equine third metacarpal bone (MC3) stabilized with either an AO or AP screw. Methods: In vitro biomechanical assessment of screw-insertion variables, and shear failure tests of a bone-screw-stabilized simulated lateral condylar fracture. Methods: Eight pairs of cadaveric equine MC3s Methods: Metacarpi were placed in a fixture and centered on a biax...
Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of three 4.5-mm and two 5.5-mm cortical screws.
Veterinary surgery : VS    May 8, 2001   Volume 30, Issue 3 287-294 doi: 10.1053/jvet.2001.23353
Watt BC, Edwards RB, Markel MD, McCabe R, Wilson DG.To compare the biomechanical characteristics and mode of failure of 2 parallel-screw techniques for proximal interphalangeal joint arthrodesis in horses. Methods: Randomized block design, blocking for horse (1-5), method of screw fixation (three 4.5-mm vs two 5.5-mm), side (left limb vs right limb), and end (front limb vs hind limb). Constructs were loaded to failure in 3-point bending in a dorsal-to-palmar (plantar) direction. Methods: Twenty limbs (10 limb pairs) from 5 equine cadavers. Methods: A combined aiming device was used to facilitate consistent screw placement. Three parallel 4.5-mm...
Magnetic resonance imaging of two normal equine brains and their associated structures.
The Veterinary record    April 6, 2001   Volume 148, Issue 8 229-232 doi: 10.1136/vr.148.8.229
Vázquez JM, Rivero M, Gil F, Ramírez JA, Ramírez G, Vilar JM, Arencibia A.Magnetic resonance images were obtained from two isolated horses' heads. Ten mm thick, T1-weighted images were taken with a 1.5 Tesla magnet and a body coil, and compared with the corresponding frozen cross-sections of the heads, relevant structures being identified and labelled at each level. The images should provide reference material for clinical magnetic imaging studies of horses' heads.
Screw fixation in lag fashion of equine cadaveric metacarpal and metatarsal condylar bone specimens: a biomechanical comparison of shaft and cortex screws.
Veterinary surgery : VS    December 1, 2000   Volume 29, Issue 6 564-571 doi: 10.1053/jvet.2000.17839
Rahm C, Ito K, Auer J.To compare acute fixation stability and insertion effort of cortex bone screws with and without a shaft inserted in lag fashion in equine metacarpal (metatarsal, MC(T)III) bone. Methods: Screw types with independent variables of screw diameter (4.5 or 5.5 mm) and shaft type (without shaft, with 20-mm shaft, or with 25-mm shaft) were studied. Bone specimens cut from distal equine MC(T)III condyles were used. After screw insertion in lag fashion into 2 bone blocks with an instrumented device, shear tests were conducted in a mechanical testing machine. Outcome variables of peak insertion torque, ...
In vitro comparison of the use of two large-animal, centrally threaded, positive-profile transfixation pin designs in the equine third metacarpal bone.
American journal of veterinary research    October 20, 2000   Volume 61, Issue 10 1298-1303 doi: 10.2460/ajvr.2000.61.1298
Morisset S, McClure SR, Hillberry BM, Fisher KE.To compare the in vitro holding power and associated microstructural damage of 2 large-animal centrally threaded positive-profile transfixation pins in the diaphysis of the equine third metacarpal bone. Methods: 25 pairs of adult equine cadaver metacarpal bones. Methods: Centrally threaded positive-profile transfixation pins of 2 different designs (ie, self-drilling, self-tapping [SDST] vs nonself-drilling, nonself-tapping [NDNT] transfixation pins) were inserted into the middiaphysis of adult equine metacarpal bones. Temperature of the hardware was measured during each step of insertion with ...
Concentrations of cadmium, lead and zinc in livestock feed and organs around a metal production centre in eastern Kazakhstan.
The Science of the total environment    August 16, 2000   Volume 257, Issue 1 53-60 doi: 10.1016/s0048-9697(00)00497-6
Farmer AA, Farmer AM.This paper presents results of analysis of animal feed and meat (cattle, horse and sheep) products from a metal processing region (Oskemen) in east Kazakhstan. Samples were collected from a range of districts of differing distances from the main source of anthropogenic pollution and with differing underlying metal-containing geologies. Analyses for cadmium, lead and zinc revealed high concentrations in many feed and meat samples. Horse (an important food animal) samples had higher levels of contamination than cattle, which were higher than sheep. For example, mean cadmium concentrations in hor...