Analyze Diet

Topic:Diagnostic Technique

Diagnostic techniques in equine medicine encompass a range of procedures and tools used to identify diseases, injuries, or other health conditions in horses. These techniques include imaging methods such as radiography, ultrasonography, and magnetic resonance imaging (MRI), as well as laboratory tests like blood work and tissue biopsies. Each diagnostic method provides specific information that can aid in the assessment and management of equine health issues. Radiography is commonly used for evaluating bone structures, while ultrasonography is useful for soft tissue examination. MRI offers detailed images of both soft and hard tissues, though its use is limited by cost and availability. Laboratory tests can detect biochemical and hematological changes indicative of disease. This page compiles peer-reviewed research studies and scholarly articles that explore the development, application, and efficacy of various diagnostic techniques in equine veterinary practice.
Premature luteal regression in a pregnant mare and subsequent pregnancy maintenance with the use of oral altrenogest.
Equine veterinary journal    March 13, 2012   Volume 45, Issue 1 97-100 doi: 10.1111/j.2042-3306.2012.00559.x
Canisso IF, Beltaire KA, Bedford-Guaus SJ.Premature luteal demise or luteal insufficiency is not well characterised as a cause of pregnancy loss in domestic species, including horses. In this report, a mare inseminated with cooled-transported semen at our facility returned for a routine pregnancy diagnosis at 15 days post ovulation. Ultrasonography per rectum revealed endometrial oedema and the absence of visual indication of a corpus luteum on either ovary. Nonetheless, an embryonic vesicle small for the gestational age was identified. Daily oral altrenogest treatment was implemented immediately. Serum progesterone concentration was ...
Production of bacteriocin by Leuconostoc mesenteroides 406 isolated from Mongolian fermented mare’s milk, airag.
Animal science journal = Nihon chikusan Gakkaiho    March 13, 2012   Volume 83, Issue 10 704-711 doi: 10.1111/j.1740-0929.2012.01010.x
Wulijideligen , Asahina T, Hara K, Arakawa K, Nakano H, Miyamoto T.The purification and characterization of a bacteriocin produced by Leuconostoc mesenteroides strain 406 that was isolated from traditional Mongolian fermented mare's milk, airag, were carried out. Leuconostoc mesenteroides strain 406 was identified on the basis of its morphological and biochemical characteristics and carbohydrate fermentation profile and by API 50 CH kit and 16S ribosomal DNA analyses. The neutral-pH cell-free supernatant of this bacterium inhibited the growth of several lactic acid bacteria and food spoilage and pathogenic organisms, including Listeria monocytogenes and Clost...
Prevalence of Parascaris equorum infection in foals on French stud farms and first report of ivermectin-resistant P. equorum populations in France.
Veterinary parasitology    March 9, 2012   Volume 188, Issue 1-2 185-189 doi: 10.1016/j.vetpar.2012.02.022
Laugier C, Sevin C, Ménard S, Maillard K.No abstract available
Contribution of dynamic calibration to the measurement accuracy of a pressure plate system throughout the stance phase in sound horses.
Veterinary journal (London, England : 1997)    March 3, 2012   Volume 193, Issue 2 471-474 doi: 10.1016/j.tvjl.2012.01.029
Oosterlinck M, Pille F, Sonneveld DC, Oomen AM, Gasthuys F, Back W.The aim of this study was to evaluate the accuracy of the vertical force curve of a pressure plate (PP) using dynamic calibration with a force plate (FP) in six sound Warmblood horses. The animals were walked and trotted over a combined PP-FP system sampling at 250 Hz. Five valid measurements of each forelimb were collected. The recalibration factor (RF), the ratio between the calibrated and raw PP data, was evaluated in each timeframe throughout the stance phase. Following dynamic calibration, the vertical force curve of the PP demonstrated a characteristic biphasic pattern at the walk and ty...
Exostoses on the palmar or plantar aspect of the diaphysis of the third metacarpal or metatarsal bone in horses: 16 cases (2001-2010).
Journal of the American Veterinary Medical Association    March 3, 2012   Volume 240, Issue 6 740-747 doi: 10.2460/javma.240.6.740
Bertoni L, Forresu D, Coudry V, Audigie F, Denoix JM.To characterize the clinical features, diagnostic procedures, treatment, and outcome for horses with an exostosis on the palmar or plantar cortex of the third metacarpal bone (MC3) or third metatarsal bone (MT3). Methods: Retrospective case series. Methods: 16 horses. Methods: Records from 2001 through 2010 were evaluated to identify horses with radiographic and ultrasonographic evidence of an exostosis on an MC3 or MT3. Signalment, history, lameness examination results, diagnostic imaging results, surgical and histopathologic findings, treatment, and outcome were evaluated. Results: 9 horses ...
Diagnostic sensitivity and specificity of in situ hybridization and immunohistochemistry for Eastern equine encephalitis virus and West Nile virus in formalin-fixed, paraffin-embedded brain tissue of horses. Pennick KE, McKnight CA, Patterson JS, Latimer KS, Maes RK, Wise AG, Kiupel M.Immunohistochemistry (IHC) and in situ hybridization (ISH) can be used either to detect or to differentiate between Eastern equine encephalitis virus (EEEV) and West Nile virus (WNV) within formalin-fixed, paraffin-embedded (FFPE) brain tissue of horses. To compare the diagnostic sensitivity and specificity of ISH and IHC, FFPE brain tissue from 20 EEEV-positive horses and 16 WNV-positive horses were tested with both EEEV and WNV oligoprobes and EEEV- and WNV-specific antibodies. Reverse transcription polymerase chain reaction (RT-PCR) for detection of EEEV and WNV was used as the gold standar...
Comparison of an inertial sensor system with a stationary force plate for evaluation of horses with bilateral forelimb lameness.
American journal of veterinary research    March 1, 2012   Volume 73, Issue 3 368-374 doi: 10.2460/ajvr.73.3.368
Keegan KG, MacAllister CG, Wilson DA, Gedon CA, Kramer J, Yonezawa Y, Maki H, Pai PF.To assess the analytic sensitivity of an inertial sensor system for detection of the more severely affected forelimb in horses with bilateral lameness. Methods: 18 adult horses with forelimb lameness. Methods: Horses were fitted with inertial sensors and evaluated for lameness with a stationary force plate as they were trotted in a straight line. Inertial sensor-derived measurements for vertical head movement asymmetry (HMA) and vector sum (VS) of maximum and minimum head height differences between right and left halves of the stride were used to predict differences in mean peak vertical force...
Standing CT and clinical progression of equine cholesterol granulomata.
The Veterinary record    March 1, 2012   Volume 170, Issue 11 289 doi: 10.1136/vr.100537
Finding E, Fletcher N, Avella C, Naylor RJ, Volk HA, Weller R, Dunkel B, Piercy RJ.No abstract available
Evaluation of the automated hematology analyzer Sysmex XT-2000iV ™ compared to the ADVIA ® 2120 for its use in dogs, cats, and horses. Part II: Accuracy of leukocyte differential and reticulocyte count, impact of anticoagulant and sample aging. Bauer N, Nakagawa J, Dunker C, Failing K, Moritz A.The automated laser-based hematology analyzer Sysmex XT-2000iV™ provides a 5-part differential count and specific cytograms that are of great interest for large veterinary laboratories. The aim of the study was to validate the Sysmex XT-2000iV compared to the laser-based hematology analyzer ADVIA® 2120 and manual differential in dogs, cats, and horses as well as the impact of anticoagulant (heparin, ethylenediamine tetra-acetic acid [EDTA], and citrate) and storage at 22°C and 4°C. Consecutive fresh K(3)-EDTA blood samples from 216 cats, 314 dogs, and 174 horses were included. The impact ...
Accuracy and precision of computer-assisted analysis of bone density via conventional and digital radiography in relation to dual-energy x-ray absorptiometry.
American journal of veterinary research    March 1, 2012   Volume 73, Issue 3 381-384 doi: 10.2460/ajvr.73.3.381
Vaccaro C, Busetto R, Bernardini D, Anselmi C, Zotti A.To evaluate the precision and accuracy of assessing bone mineral density (BMD) by use of mean gray value (MGV) on digitalized and digital images of conventional and digital radiographs, respectively, of ex vivo bovine and equine bone specimens in relation to the gold-standard technique of dual-energy x-ray absorptiometry (DEXA). Methods: Left and right metatarsal bones from 11 beef cattle and right femurs from 2 horses. Methods: Bovine specimens were imaged by use of conventional radiography, whereas equine specimens were imaged by use of computed radiography (digital radiography). Each specim...
Contamination of joints with tissue debris and hair after arthrocentesis: the effect of needle insertion angle, spinal needle gauge, and insertion of spinal needles with and without a stylet.
Veterinary surgery : VS    March 1, 2012   Volume 41, Issue 3 391-398 doi: 10.1111/j.1532-950X.2011.00969.x
Wahl K, Adams SB, Moore GE.To assess fetlock joint contamination with tissue debris and hair after arthrocentesis. Methods: Experimental. Methods: Fetlock joint tissues (n = 10 horses). Methods: Soft tissue flaps including the joint capsule were dissected from the dorsal fetlock joints of 7 anesthetized horses leaving an intact proximal base. Needles inserted through the tissue flaps were flushed into tissue cell culture plates and examined for debris. Studies were repeated on excised fetlock tissue preparations after being stored for 5 days. Variables included gauge and type of needle, insertion of spinal needles with ...
Evaluation of the automated hematology analyzer Sysmex XT-2000iV™ compared to the ADVIA® 2120 for its use in dogs, cats, and horses: Part I–precision, linearity, and accuracy of complete blood cell count. Bauer N, Nakagawa J, Dunker C, Failing K, Moritz A.The automated laser-based hematology analyzer Sysmex XT-2000iV™ providing a complete blood cell count (CBC) and 5-part differential has been introduced in large veterinary laboratories. The aim of the current study was to determine precision, linearity, and accuracy of the Sysmex analyzer. Reference method for the accuracy study was the laser-based hematology analyzer ADVIA® 2120. For evaluation of accuracy, consecutive fresh blood samples from healthy and diseased cats (n = 216), dogs (n = 314), and horses (n = 174) were included. A low intra-assay coefficient of variation (CV) of approxim...
The approach to the equine dermatology case in practice.
The Veterinary clinics of North America. Equine practice    February 28, 2012   Volume 28, Issue 1 131-153 doi: 10.1016/j.cveq.2012.01.004
Knottenbelt DC.A logical and thorough clinical investigation should provide the best basis for the diagnosis of skin diseases. Where no diagnosis can be reached despite a full range of investigations, the clinician can justifiably attempt symptomatic treatment, but it is always better to focus treatment on a specific condition based on properly accumulated and tested clinical evidence. Unfortunately, in equine dermatology there are few text descriptions of the majority of the conditions encountered in practice. While a few diseases are well recognized, there is still little consensus on the best treatments f...
Comparison of four techniques for synoviocentesis of the equine digital flexor tendon sheath: a cadaveric study.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    February 27, 2012   Volume 25, Issue 3 178-183 doi: 10.3415/VCOT-11-06-0085
Jordana M, Oosterlinck M, Pille F, Valère A, Martens A.To compare four different techniques for synoviocentesis of the equine digital flexor tendon sheath (DFTS). Methods: Fifteen inexperienced operators performed each of the following injection techniques on two cadaveric limbs: Proximal (at the proximal recess of the DFTS), Axial (axial to the proximal sesamoid bone), Base (at the base of the proximal sesamoid bone), and Distal (at the pastern). The number of attempts needed before the needle was assumed to be correctly positioned into the DFTS was recorded and 10 ml of methylene blue was injected. The limbs were dissected to determine the prese...
C-Terminal region of 48-kDa rhoptry protein for serological detection of Babesia caballi antibodies in horses.
Parasitology international    February 25, 2012   Volume 61, Issue 3 493-496 doi: 10.1016/j.parint.2012.02.006
Terkawi MA, Alhasan H, Ueno A, Ratthanophart J, Luo Y, Cao S, Kamyingkird K, Aboulaila M, Youn-Kyoung G, Nishikawa Y, Yokoyama N, Xuan X, Igarashi I.A recombinant C-terminal antigen derived from Babesia caballi 48-kDa rhoptry protein (rBc48/CT) was made for the development of a serologically diagnostic test. Antiserum raised against the rBc48/CT reacted specifically with the corresponding native protein by Western blotting and the indirect fluorescent antibody test (IFAT). Next, an indirect enzyme-linked immunosorbent assay (Bc48/CT-ELISA) and an immunochromatographic test based on the Bc48/CT (Bc48/CT-ICT) were constructed and employed for the detection of an antibody to B. caballi in a variety of equine sera. The results of Bc48/CT-ELISA...
Identification of a periorbital wooden foreign body as the cause of chronic ocular discharge in a horse.
Australian veterinary journal    February 22, 2012   Volume 90, Issue 3 84-87 doi: 10.1111/j.1751-0813.2011.00876.x
Santos M, Gutierrez-Nibeyro S, Stewart A, Hyde R, Rodgerson D.The clinical, diagnostic and therapeutic features of a horse with a wooden foreign body embedded in the deep portion of the right masseter muscle adjacent to the right orbit are presented. The purpose of this report is to describe the clinical presentation, magnetic resonance imaging findings and treatment of a penetrating wooden foreign body in a horse that had no history of trauma or evidence of a puncture wound. This report documents the usefulness of magnetic resonance imaging to detect a wooden foreign body embedded in the soft tissues of a horse with a chronic copious ocular discharge. T...
Standing low-field magnetic resonance imaging in horses with chronic foot pain.
Australian veterinary journal    February 22, 2012   Volume 90, Issue 3 75-83 doi: 10.1111/j.1751-0813.2011.00875.x
Gutierrez-Nibeyro S, Werpy N, White Ii N.Conventional imaging modalities can diagnose the source of foot pain in most cases, but have limitations in some horses, which can be overcome by using magnetic resonance imaging (MRI). However, there are no reports of the MRI appearance and prevalence of foot lesions of a large series of horses with chronic foot lameness. Methods: In the present study, 79 horses with unilateral or bilateral forelimb lameness because of chronic foot pain underwent standing low-field MRI to make a definitive diagnosis. Results: Of the 79 horses, 74 (94%) had alterations in >1 structure in the lame or lamest foo...
Seroprevalence of Neospora spp. in Horses in North East of Iran.
Iranian journal of parasitology    February 22, 2012   Volume 6, Issue 2 64-68 
Hosseini M, Moraveji M, Tahamtan Y, Rahimian A, Mohammadi G, Namavari M.Neospora caninum, an obligate intracellular protozoan parasite, is recognized as a major cause of abortion in cattle, while limited information is presently available on the seroprevalence of Neospora antibodies in horses' worldwide. The aim of the present study was to determine serologic prevalence of Neospora infection in horses in Iran. Methods: Sera from 150 horses from Mashhad suburb in Razavi Khorasan Province, northeast Iran were examined for antibodies to Neospora spp. using Neospora modified direct agglutination test (N-MAT). Results: Antibodies to this parasite were detected in 45 (3...
The role of diffusion in ferritin-induced relaxation enhancement of protons.
Journal of magnetic resonance (San Diego, Calif. : 1997)    February 22, 2012   Volume 217 36-40 doi: 10.1016/j.jmr.2012.02.005
Boss MA, Chris Hammel P.The influence of proton diffusion on nuclear magnetic resonance (NMR) relaxation was investigated in the presence of horse spleen ferritin at 7 T. Binary mixtures of water and glycerol were used to control diffusion within the range of 0.6-2.0 × 10(-9)m(2)/s, which was confirmed by pulsed gradient techniques. The effect of chemical exchange by hydrolysis between water and glycerol on relaxation was characterized with Carr-Purcell-Meiboom-Gill (CPMG) dispersion experiments. The relaxation rate enhancement of the protons due to ferritin was found to be inversely proportional to the diffusion co...
Detection of myo-inositol trispyrophosphate in equine urine and plasma by hydrophillic interaction chromatography-tandem mass spectrometry.
Drug testing and analysis    February 22, 2012   Volume 4, Issue 5 355-361 doi: 10.1002/dta.397
Wong AS, Ho EN, Wan TS.Myo-inositol trispyrophosphate (ITPP) is a new drug capable of increasing the amount of oxygen in hypoxic tissues. Studies have shown that administration of ITPP increases the maximal exercise capacity in normal mice as well as mice with severe heart failure. The properties of ITPP make it an ideal candidate as a doping agent to enhance performance in racehorses. While there have been speculations in the horseracing industry that the covert use of ITPP is already widespread, no reported method exists for the detection of ITPP in equine biological samples. ITPP is a difficult-to-detect drug due...
An investigation of a recent outbreak of nocardioform placentitis caused abortions in horses.
Veterinary microbiology    February 21, 2012   Volume 158, Issue 3-4 425-430 doi: 10.1016/j.vetmic.2012.02.023
Erol E, Sells SF, Williams NM, Kennedy L, Locke SJ, Labeda DP, Donahue JM, Carter CN.Nocardioform placentitis associated with gram positive branching actinomycetes caused a record number of abortions in mares diagnosed by the University of Kentucky Veterinary Diagnostic Laboratory (UKVDL) affecting the 2011 foal crop (2011 foal crop: the cohort of foals conceived during the 2010 breeding season). The goal of the present study is to make a comprehensive analysis of this outbreak in terms of frequencies of the bacteria causing nocardioform placentitis mediated abortions and to investigate the ages of fetuses, abortion months and breeding times. In the present study, characterist...
Molecular evidence for natural killer-like cells in equine endometrial cups.
Placenta    February 21, 2012   Volume 33, Issue 5 379-386 doi: 10.1016/j.placenta.2012.01.018
Noronha LE, Huggler KE, de Mestre AM, Miller DC, Antczak DF.To identify equine orthologs of major NK cell marker genes and utilize them to determine whether NK cells are present among the dense infiltration of lymphocytes that surround the endometrial cup structures of the horse placenta during early pregnancy. Methods: PCR primers were developed to detect the equine orthologs of NKP46, CD16, CD56, and CD94; gene expression was detected in RNA isolated from lymphocytes using standard 2-step reverse transcriptase (RT) PCR and products were cloned and sequenced. Absolute real-time RT-PCR was used to quantitate gene expression in total, CD3+, and CD3- per...
Use of the Accutrend Plus point-of-care monitor for blood triglyceride measurement in horses.
The Veterinary record    February 20, 2012   Volume 170, Issue 9 228 doi: 10.1136/vr.100530
Naylor RJ, Durward-Akhurst SA.No abstract available
Isolation and identification of Mycobacterium avium subspecies silvaticum from a horse.
Comparative immunology, microbiology and infectious diseases    February 19, 2012   Volume 35, Issue 4 303-307 doi: 10.1016/j.cimid.2012.01.011
Chiers K, Deschaght P, De Baere T, Dabrowski S, Kotlowski R, De Clercq D, Ducatelle R, Vaneechoutte M.Routine cultivation methods are able to distinguish between isolates of the Mycobacterium avium and the Mycobacterium tuberculosis complex. However, molecular tools are needed to further identify the several subspecies in the M. avium complex, especially for the subspecies avium and silvaticum. A rapid technique using HhaI restriction digestion of a 349 bp amplification product of the 85B antigen (α-antigen) gene was used for the identification of M. avium subsp. silvaticum in a three-year-old gelding presenting with caseous, necrotizing, granulomatous lesions. The result was confirmed by seq...
Use of a pressure plate to analyse the toe-heel load redistribution underneath a normal shoe and a shoe with a wide toe in sound warmblood horses at the walk and trot.
Research in veterinary science    February 17, 2012   Volume 93, Issue 2 1026-1031 doi: 10.1016/j.rvsc.2012.01.010
Oomen AM, Oosterlinck M, Pille F, Sonneveld DC, Gasthuys F, Back W.The objective of this study was to use a pressure plate to quantify the toe-heel load redistribution in the forelimbs of sound warmblood horses with normal shoes and shoes with a wide toe and narrow branches, used empirically in the treatment of superficial digital flexor tendon or suspensory ligament injuries. In a crossover-design study, six horses, randomly shod with normal shoes and shoes with a wide toe, were led over a dynamically calibrated pressure plate to record data from both forelimbs. There were no significant differences between both shoes in the toe-heel index of stance time, pe...
The importance of vertical transmission of Neospora sp. in naturally infected horses.
Veterinary parasitology    February 16, 2012   Volume 187, Issue 3-4 367-370 doi: 10.1016/j.vetpar.2012.02.005
Antonello AM, Pivoto FL, Camillo G, Braunig P, Sangioni LA, Pompermayer E, Vogel FS.Neospora spp. is a intracellular protozoan phylogenetically closely related to Toxoplasma gondii and Sarcocystis neurona, and it can infect horses leading to the development of reproductive or neurological diseases. We determined the presence of antibodies to Neospora sp. in mares at their parturition time and determine the frequency of vertical transmission in healthy foals to verify the importance of transplacental transmission. The samples were analyzed by indirect immunofluorescence antibody test, showing that seroprevalence in mares is higher than in foals and seropositive mares are likel...
Differences in the morphology of distal border synovial invaginations of the distal sesamoid bone in the horse as evaluated by computed tomography compared with radiography.
Equine veterinary journal    February 15, 2012   Volume 44, Issue 6 679-683 doi: 10.1111/j.2042-3306.2012.00547.x
Claerhoudt S, Bergman HJ, Van Der Veen H, Duchateau L, Raes EV, Saunders JH.Distal border synovial invaginations of the distal sesamoid bone are radiographically assessed during the selection process of horses admitted as breeding stallions or in purchase examinations. Nowadays, many moderately or some deeply penetrating proximally enlarged synovial invaginations are considered as moderate or severe radiographic findings. Objective: To measure the difference between and agreement of the morphology of distal border synovial invaginations on radiography vs. computed tomography (CT). It was hypothesised that the morphology of distal border synovial invaginations would be...
[Effect of distribution of eggs of strongyles and Parascaris equorum in faecal samples of horses on detection with a combined sedimentation-flotation method].
Tierarztliche Praxis. Ausgabe G, Grosstiere/Nutztiere    February 15, 2012   Volume 40, Issue 1 21-26 
Kuhnert-Paul Y, Schmäschke R, Daugschies A.Results of parasitological examination of faecal aliquots may vary between diagnostic laboratories. To examine whether inhomogeneous distribution of worm eggs in faecal samples is responsible for this observation, horse faeces provided for routine diagnosis of helminth infection were examined. Distribution of worm eggs was assessed by examining aliquots taken from different locations of the faecal sample by a combined sedimentation-flotation method (KSFV). In addition, it was tested, whether the homogenization of a larger amount (minimum of 40 g) of faeces before performing KSFV improved repro...
Characterization of the origin and body of the normal equine rear suspensory ligament using ultrasonography, magnetic resonance imaging, and histology. Schramme M, Josson A, Linder K.The suspensory ligament is difficult to image accurately, partly because it contains ligamentous fibers, as well as noncollagenous adipose and muscle tissue in the normal horse. Our hypothesis was that magnetic resonance (MR) imaging would be more accurate than ultrasonography in identifying the size of the suspensory ligament and the presence and size of noncollagenous tissues within the ligament. Eleven horses were used for ultrasonographic and MR imaging and histologic evaluation of the rear suspensory ligament. The origin and body of the normal suspensory ligament had a heterogenous appear...
Diagnostic imaging in veterinary dental practice.
Journal of the American Veterinary Medical Association    February 9, 2012   Volume 240, Issue 4 379-381 doi: 10.2460/javma.240.4.379
Menzies RA, Lundström TS, Lewis JR, Reiter AM.No abstract available