Analyze Diet

Topic:Imaging Techniques

Imaging techniques in horses encompass a range of diagnostic tools used to visualize the internal structures and systems of equine patients. These techniques assist in the diagnosis, monitoring, and treatment planning of various conditions affecting horses. Common imaging modalities include radiography (X-rays), ultrasonography, magnetic resonance imaging (MRI), and computed tomography (CT). Each technique offers unique advantages in terms of resolution, depth of penetration, and the type of tissues that can be examined. For instance, radiography is frequently used for assessing bone structures, while ultrasonography is often employed for soft tissue evaluation. MRI and CT provide detailed cross-sectional images, aiding in the assessment of complex anatomical regions. This page compiles peer-reviewed research studies and scholarly articles that explore the application, advancements, and comparative efficacy of imaging techniques in equine veterinary medicine.
Evaluation of motion correction processing in equine bone scintigraphy by Scheffé’s method of paired comparisons.
The Journal of veterinary medical science    October 23, 2012   Volume 75, Issue 3 369-371 doi: 10.1292/jvms.12-0127
Yamaguchi T, Endo Y, Nambo Y, Sato F, Sasaki N, Yamada K.Equine bone scintigraphy is usually performed with horses in standing position under sedation. However, swaying motion often leads to poor-quality images. To examine the usefulness of motion correction (MC) processing, equine bone scintigrams were evaluated using Scheffé's method of paired comparisons. A significant difference in evaluation scores was detected by analysis of variance (F test, P<0.01). According to all observers, Yardstick analysis scores were higher for images use of MC processing than for those no use of MC processing, for all parts. Overall scores of 5 observers were as ...
Advances in nuclear medicine.
The Veterinary clinics of North America. Equine practice    October 18, 2012   Volume 28, Issue 3 527-538 doi: 10.1016/j.cveq.2012.09.004
Selberg K, Ross M.Nuclear scintigraphy is a mainstay of diagnostic imaging and has preserved its relevance in the imaging of acute and chronic trauma. It is particularly useful in the evaluation of athletic injuries. Pitfalls of interpretation, false negatives and false positives exist as with many imaging modalities. Synthesis of physical exam findings, lameness evaluation and, when possible, diagnostic analgesia in combination with nuclear scintigraphy imaging findings, will allow for the most information to be applied to the patient's clinical problem.
Digital radiography for the equine practitioner: basic principles and recent advances.
The Veterinary clinics of North America. Equine practice    October 18, 2012   Volume 28, Issue 3 483-495 doi: 10.1016/j.cveq.2012.08.003
Nelson NC, Zekas LJ, Reese DJ.As availability increases and cost decreases, digital radiograph systems become more common in equine practice. Technological advances provide an array of choices for the equine practitioner considering purchase. Two classes of systems are available: computed radiography and flat-panel systems (direct radiography). Image processing encompasses all manipulations performed on an image at acquisition and can have a profound effect on the final digital radiograph. Consideration should be given to the type of display monitor because many options are now available. The type of display monitor and th...
Computed tomographic arthrography of the equine stifle joint.
The Veterinary clinics of North America. Equine practice    October 15, 2012   Volume 28, Issue 3 583-598 doi: 10.1016/j.cveq.2012.09.002
Valdés-Martínez A.Computed tomographic arthrography is an imaging technique used for the evaluation of the internal structures of a joint, especially the soft tissues and subchondral bone defects that may communicate with the joint space. Clinical indications, technical aspects, principles of image interpretation, and advantages and disadvantages of this imaging technique for the evaluation of the equine stifle joint are discussed in this article.
Advances in equine ultrasonography.
The Veterinary clinics of North America. Equine practice    October 12, 2012   Volume 28, Issue 3 497-506 doi: 10.1016/j.cveq.2012.08.001
Neelis DA, Roberts GD.The many advancements in ultrasound technology, including spatial compounding, harmonic imaging, multidimensional and extended field-of-view images, and improvements in transducer capabilities, are used to enhance the ultrasonographic examination of the equine patient. The improvements in software and hardware capabilities help overcome artifacts, improve image quality, and allow better documentation of the examination for follow-up studies. In addition, the ability of smaller, more portable machines to produce better images is ideal for the ambulatory practice setting.
Ultrasound-guided retrobulbar nerve block in horses: a cadaveric study.
Veterinary anaesthesia and analgesia    October 11, 2012   Volume 40, Issue 2 205-211 doi: 10.1111/j.1467-2995.2012.00780.x
Morath U, Luyet C, Spadavecchia C, Stoffel MH, Hatch GM.To develop an ultrasound-guided technique for retrobulbar nerve block in horses, and to compare the distribution of three different volumes of injected contrast medium (CM) (4, 8 and 12 mL), with the hypothesis that successful placement of the needle within the retractor bulbi muscle cone would lead to the most effective dispersal of CM towards the nerves leaving the orbital fissure. Methods: Prospective experimental cadaver study. Methods: Twenty equine cadavers. Methods: Ultrasound-guided retrobulbar injections were performed in 40 cadaver orbits. Ultrasound visualization of needle placement...
Ultrasonographic visualization of colonic mesenteric vasculature as an indicator of large colon right dorsal displacement or 180° volvulus (or both) in horses.
The Canadian veterinary journal = La revue veterinaire canadienne    October 2, 2012   Volume 53, Issue 4 378-382 
Ness SL, Bain FT, Zantingh AJ, Gaughan EM, Story MR, Nydam DV, Divers TJ.Visualization of colonic mesenteric vasculature during transabdominal ultrasonographic examination of horses with colic can be a predictor of right dorsal displacement of the large colon or 180° large colon volvulus, or both. Medical records of 82 horses having had surgical treatment of colic and having received a transabdominal ultrasonographic examination on admission were reviewed. Colonic mesenteric vessels were sonographically identified coursing laterally on the right side of the abdomen in 24 of the 82 cases. Horses with colonic vessels identified on ultrasound were 32.5 times more lik...
The effects of perineural and intrasynovial anaesthesia of the equine foot on subsequent magnetic resonance images.
Equine veterinary journal    September 26, 2012   Volume 45, Issue 3 320-325 doi: 10.1111/j.2042-3306.2012.00649.x
Black B, Cribb NC, Nykamp SG, Thomason JJ, Trout DR.Artefacts caused by regional anaesthesia can influence image interpretation of ultrasonography and nuclear scintigraphy. Perineural and intrasynovial anaesthesia are commonly performed prior to magnetic resonance imaging (MRI); and the effects on MR images, if any, are unknown. Objective: To determine if perineural and intrasynovial anaesthesia of structures in the equine foot cause iatrogenic changes detectable with MRI. Methods: A baseline MRI examination of both front feet was performed on 15 horses, 2-6 days prior to mepivacaine injection adjacent to the lateral and medial palmar digital n...
Time-of-flight magnetic resonance angiography (TOF-MRA) of the normal equine head.
Equine veterinary journal    September 4, 2012   Volume 45, Issue 2 187-192 doi: 10.1111/j.2042-3306.2012.00621.x
Manso-Díaz G, García-Real MI, Casteleyn C, San-Román F, Taeymans O.Noncontrast magnetic resonance angiography (MRA) is widely used in human and small animal medicine. However, this technique has not yet been described in the horse, and compared to other angiographic techniques MRA could be more cost efficient and potentially safer. Objective: The aim of this study was to provide a comprehensive anatomical reference of the normal equine head vasculature using a noncontrast MRA technique, on both low- and high-field MRI. Methods: Five healthy adult horses were examined, 4 with a low-field magnet (0.23T) and the remaining one with a high-field magnet (1.5T). The...
The effect of varying echo time using T2-weighted FSE sequences on the magic angle effect in the collateral ligaments of the distal interphalangeal joint in horses. Werpy NM, Ho CP, Garcia EB, Kawcak CE.Eight skeletally mature equine cadaver distal forelimbs were imaged using T2-weighted fast spin echo (FSE) sequences in a 1.0 T horizontal bore magnet. Each limb was parallel to the main magnetic field and with 16° angulation of the limb relative to the main magnetic field, which places one of the collateral ligaments of the distal interphalangeal joint at or near the magic angle. Each limb was imaged using an echo time (TE) of 80, 100, 120, and 140 ms. Reversal of the magic angle effect was achieved at echo time of 140 ms. However, given the alterations in tissue contrast and subjective decr...
Morphology of distal border synovial invaginations of the equine distal sesamoid bone: comparison between computed tomography and a hoof-specific radiographic projection.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    July 27, 2012   Volume 25, Issue 6 453-459 doi: 10.3415/VCOT-11-10-0149
Claerhoudt S, Bergman HJ, van der Veen H, Duchateau L, Raes EV, Vanderperren K, Saunders JH.To compare the difference and agreement of the morphology of distal border synovial invaginations on a dorsoproximal-palmarodistal oblique (DPr-PaDiO) projection with hoof-specific angle versus computed tomography. Methods: Computed tomography (CT) images and a DPr-PaDiO radiographic projection with hoof-specific angle were obtained on 50 cadaveric forefeet from 25 Warmblood horses. Computed tomography was assumed to be the gold standard. The number, shape and depth of penetration of distal border synovial invaginations into the distal sesamoid bone were evaluated with both methods, and the co...
Equine imaging: the framework for applying therapeutic farriery.
The Veterinary clinics of North America. Equine practice    July 18, 2012   Volume 28, Issue 2 293-312 doi: 10.1016/j.cveq.2012.05.001
Eggleston RB.Radiographic evaluation of a horse's foot gives tremendous insight into the relationship between the structures within the foot and between the foot and distal limb. The information gained from a radiographic study is highly dependent on the quality of the radiographs. A systematic approach should be taken when planning a radiographic study of the foot. Taking the time to examine the foot and prepare it properly will avoid the need, risk, and expense of repeating images and will improve the quality and therefore the interpretation of your radiographic images. When evaluating the foot for podia...
The proximal aspect of the suspensory ligament in the horse: How precise are ultrasonographic measurements?
Equine veterinary journal    July 12, 2012   Volume 45, Issue 2 164-169 doi: 10.1111/j.2042-3306.2012.00597.x
Zauscher JM, Estrada R, Edinger J, Lischer CJ.To evaluate intra- and interobserver variability in ultrasonographic measurements of the proximal aspect of the suspensory ligament (PSL) in the horse. Objective: A minimum difference of ≥20% is required to differentiate reliably between physiological and pathological alterations related to dimensions. Methods: Two operators examined the PSL in all 4 limbs of 14 horses twice using different techniques and different probes with and without standoff pads. Measurements were taken from the longitudinal and transverse images. Inter- and intraoperator variability was evaluated using agreement indi...
Contrast-Enhanced Micro-Computed Tomography in Evaluation of Spontaneous Repair of Equine Cartilage.
Cartilage    July 1, 2012   Volume 3, Issue 3 235-244 doi: 10.1177/1947603511424173
Kulmala KA, Pulkkinen HJ, Rieppo L, Tiitu V, Kiviranta I, Brünott A, Brommer H, van Weeren R, Brama PA, Mikkola MT, Korhonen RK, Jurvelin JS....Contrast-enhanced computed tomography (CECT) has been introduced for the evaluation of cartilage integrity. Furthermore, CECT enables imaging of the structure and density of subchondral bone. In this laboratory study, we investigate the potential of microCECT to simultaneously image cartilage and subchondral bone for the evaluation of tissue healing. Methods: Osteochondral lesions (Ø = 6 mm) were surgically created in equine intercarpal joints (n = 7). After spontaneous healing for 12 months, the horses were sacrificed and osteochondral plugs (Ø = 14 mm), including the repair cartilage and a...
Ovarian ultrasonography in the mare.
Reproduction in domestic animals = Zuchthygiene    June 15, 2012   Volume 47 Suppl 3 30-33 doi: 10.1111/j.1439-0531.2012.02043.x
Miro J.Ultrasonography has become indispensable in the control of equine reproduction. Mare ovary layers are inverted with respect to other species, with the follicles and corpus luteum found inside the ovary; only large follicles protrude from the organ's surface. This renders the making of diagnoses via rectal palpation of the ovaries very difficult. Ultrasound imaging, however, provides another avenue of examination. Since its first use in 1980, the diagnostic potential of ultrasonography has greatly improved. Colour Doppler ultrasonography can even asses blood flow, allowing for much better monit...
Evaluation of a positioning method for equine lateral stifle scintigrams.
Acta veterinaria Scandinavica    June 15, 2012   Volume 54, Issue 1 38 doi: 10.1186/1751-0147-54-38
Grapperon Mathis M, Ley C, Berger M, Hansson K.The current lack of a standardized protocol for positioning of the gamma camera relative to the horse limb in a lateral stifle scintigram, and thus the reliance on subjective positioning, may be a cause of diagnostic error and inter-operator variability due to variations of the view angle. The aims of this study were to develop a reliable method to obtain a lateral scintigram of the equine stifle based on fixed anatomical landmarks and measure the resulting foot to gamma camera angle on sequential measurements of the same horse and of different horses Methods: Technetium filled capsules were g...
Tendon structure changes after maximal exercise in the Thoroughbred horse: use of ultrasound tissue characterisation to detect in vivo tendon response.
Veterinary journal (London, England : 1997)    June 1, 2012   Volume 194, Issue 3 338-342 doi: 10.1016/j.tvjl.2012.04.024
Docking SI, Daffy J, van Schie HT, Cook JL.Investigations into the response of the superficial digital flexor tendon (SDFT) of the Thoroughbred horse to mechanical stimuli have been limited to in vitro cell culture studies focused primarily on gene expression of critical matrix proteins. It is uncertain how well in vitro outcomes translate to the tendon of the horse during exercise. The current study examined changes in tendon structure in response to maximal exercise using ultrasound tissue characterisation (UTC) to scan the SDFT prior to and after competitive racing. UTC uses contiguous transverse ultrasound images to assess the dyna...
Magic angle magnetic resonance imaging of diode laser induced and naturally occurring lesions in equine tendons. Spriet M, Murphy B, Vallance SA, Vidal MA, Whitcomb MB, Wisner ER.Magic angle magnetic resonance (MR) imaging consists of imaging tendons at 55° to the magnetic field. In people, magic angle MR imaging is valuable for detection of chronic tendon lesions and allows calculation of tendon T1 values. Increased T1 values occur in people with chronic tendinopathy. The T1 values of normal equine tendons have been reported but there are no available data for abnormal equine tendons. Twelve limbs were studied. Two limbs had diode laser tendon lesions induced postmortem, four limbs had diode laser tendon lesions induced in vivo and six limbs had naturally occurring t...
Comparison of radiography, nuclear scintigraphy, and magnetic resonance imaging for detection of specific conditions of the distal tarsal bones of horses: 20 cases (2006-2010).
Journal of the American Veterinary Medical Association    April 21, 2012   Volume 240, Issue 9 1109-1114 doi: 10.2460/javma.240.9.1109
Daniel AJ, Judy CE, Rick MC, Saveraid TC, Herthel DJ.To describe pathological findings identified with MRI in the distal tarsal bones of horses with unilateral hind limb lameness attributable to tarsal pain and to compare the usefulness of MRI with that of radiography and nuclear scintigraphy in evaluation of this region. Methods: Retrospective case series. Methods: 20 lame horses. Methods: In all horses, MRI, radiography (4 standard projections), and nuclear scintigraphy of the tarsus had been performed. Horses were excluded if the results of all 3 imaging modalities were not available or if lameness was detected in more than 1 limb. Pathologic...
Comparison of ultrasound and optical coherence tomography techniques for evaluation of integrity of spontaneously repaired horse cartilage.
Journal of medical engineering & technology    March 24, 2012   Volume 36, Issue 3 185-192 doi: 10.3109/03091902.2012.663054
Virén T, Huang YP, Saarakkala S, Pulkkinen H, Tiitu V, Linjama A, Kiviranta I, Lammi MJ, Brünott A, Brommer H, Van Weeren R, Brama PA, Zheng YP....The aim of this study was to compare sensitivity of ultrasound and optical coherence tomography (OCT) techniques for the evaluation of the integrity of spontaneously repaired horse cartilage. Articular surfaces of horse intercarpal joints, featuring both intact tissue and spontaneously healed chondral or osteochondral defects, were imaged ex vivo with arthroscopic ultrasound and laboratory OCT devices. Quantitative ultrasound (integrated reflection coefficient (IRC), apparent integrated backscattering coefficient (AIB) and ultrasound roughness index (URI)) and optical parameters (optical refle...
Standing CT and clinical progression of equine cholesterol granulomata.
The Veterinary record    March 1, 2012   Volume 170, Issue 11 289 doi: 10.1136/vr.100537
Finding E, Fletcher N, Avella C, Naylor RJ, Volk HA, Weller R, Dunkel B, Piercy RJ.No abstract available
Accuracy and precision of computer-assisted analysis of bone density via conventional and digital radiography in relation to dual-energy x-ray absorptiometry.
American journal of veterinary research    March 1, 2012   Volume 73, Issue 3 381-384 doi: 10.2460/ajvr.73.3.381
Vaccaro C, Busetto R, Bernardini D, Anselmi C, Zotti A.To evaluate the precision and accuracy of assessing bone mineral density (BMD) by use of mean gray value (MGV) on digitalized and digital images of conventional and digital radiographs, respectively, of ex vivo bovine and equine bone specimens in relation to the gold-standard technique of dual-energy x-ray absorptiometry (DEXA). Methods: Left and right metatarsal bones from 11 beef cattle and right femurs from 2 horses. Methods: Bovine specimens were imaged by use of conventional radiography, whereas equine specimens were imaged by use of computed radiography (digital radiography). Each specim...
Differences in the morphology of distal border synovial invaginations of the distal sesamoid bone in the horse as evaluated by computed tomography compared with radiography.
Equine veterinary journal    February 15, 2012   Volume 44, Issue 6 679-683 doi: 10.1111/j.2042-3306.2012.00547.x
Claerhoudt S, Bergman HJ, Van Der Veen H, Duchateau L, Raes EV, Saunders JH.Distal border synovial invaginations of the distal sesamoid bone are radiographically assessed during the selection process of horses admitted as breeding stallions or in purchase examinations. Nowadays, many moderately or some deeply penetrating proximally enlarged synovial invaginations are considered as moderate or severe radiographic findings. Objective: To measure the difference between and agreement of the morphology of distal border synovial invaginations on radiography vs. computed tomography (CT). It was hypothesised that the morphology of distal border synovial invaginations would be...
Comparison of ultrasound-guided vs. ‘blind’ techniques for intra-synovial injections of the shoulder area in horses: scapulohumeral joint, bicipital and infraspinatus bursae.
Equine veterinary journal    February 15, 2012   Volume 44, Issue 6 674-678 doi: 10.1111/j.2042-3306.2011.00540.x
Schneeweiss W, Puggioni A, David F.Diagnosis and treatment of pathologies involving synovial structures in the shoulder region are technically difficult. Ultrasound-guided (UG) injection techniques have been shown to be highly accurate, safe and reliable for various structures in human and equine patients. Objective: To develop easy-to-use and reliable UG injection techniques for the infraspinatus bursa (IB), bicipital bursa (BB) and scapulohumeral joint (SHJ) and to compare them with conventional 'blind' methods. Methods: Eight pairs of equine shoulders were positioned on a computed-tomography (CT) table with left and right sh...
Characterization of the origin and body of the normal equine rear suspensory ligament using ultrasonography, magnetic resonance imaging, and histology. Schramme M, Josson A, Linder K.The suspensory ligament is difficult to image accurately, partly because it contains ligamentous fibers, as well as noncollagenous adipose and muscle tissue in the normal horse. Our hypothesis was that magnetic resonance (MR) imaging would be more accurate than ultrasonography in identifying the size of the suspensory ligament and the presence and size of noncollagenous tissues within the ligament. Eleven horses were used for ultrasonographic and MR imaging and histologic evaluation of the rear suspensory ligament. The origin and body of the normal suspensory ligament had a heterogenous appear...
Diagnostic imaging in veterinary dental practice.
Journal of the American Veterinary Medical Association    February 9, 2012   Volume 240, Issue 4 379-381 doi: 10.2460/javma.240.4.379
Menzies RA, Lundström TS, Lewis JR, Reiter AM.No abstract available
Precision of a photogrammetric method to perform 3D wound measurements compared to standard 2D photographic techniques in the horse.
Equine veterinary journal    January 28, 2012   Volume 45, Issue 1 41-46 doi: 10.1111/j.2042-3306.2011.00538.x
Labens R, Blikslager A.Methods of 3D wound imaging in man play an important role in monitoring of healing and determination of the prognosis. Standard photographic assessments in equine wound management consist of 2D analyses, which provide little quantitative information on the wound bed. Objective: 3D imaging of equine wounds is feasible using principles of stereophotogrammetry. 3D measurements differ significantly and are more precise than results with standard 2D assessments. Methods: Repeated specialised photographic imaging of 4 clinical wounds left to heal by second intention was performed. The intraoperator ...
The influence of temperature and age on the T1 relaxation time of the equine distal limb. Adrian AM, Koene M, Roberts S, Doughty P, Bolas N, Kinns J, Brehm W, Gerlach K.The extent of fat suppression using short tau inversion recovery (STIR) imaging is variable between horses. Our aim was to determine if patient's age and/or hoof temperature have an influence on the T(1) relaxation time of bone marrow in the equine distal limb, thereby affecting the suppression of fat signal. Magnetic resonance imaging was conducted on standing horses and cadaver samples using a low-field magnet (0.27 T). The hoof temperature was measured at the lateral side of the coronary band. A modified inversion recovery fast spin-echo (IR-FSE) sequence was used to measure the signal inte...
Detection of small tendon lesions by sonoelastographic visualization of strain profile differences: initial experiences.
Skeletal radiology    January 5, 2012   Volume 41, Issue 9 1073-1079 doi: 10.1007/s00256-011-1349-2
Buck AR, Verstraete N, Li Y, Schweizer A, Snedeker JG, Buck FM.To assess the capability of a commercial sonoelastography system to detect small tendon lesions by quantitative analysis of elastogram profiles. Methods: Strips of equine digital flexor tendons were used to model small human tendons. Two tendons were examined. From each tendon, six unmodified tendon strips (controls) and six tendon strips with a central defect of the same tendons were compared. The tendon strips were placed under a physiological tensile strain of 5%. Sonoelastographic visualization of the strain profile was performed. Regions of interest (ROI) were defined left and right of th...
Three-dimensional ultrasound imaging of the equine fetus.
Theriogenology    December 20, 2011   Volume 77, Issue 7 1480-1486 doi: 10.1016/j.theriogenology.2011.10.020
Kotoyori Y, Yokoo N, Ito K, Murase H, Sato F, Korosue K, Nambo Y.The objective was to assess the optimal procedure for real-time, three-dimensional (3D) ultrasound (US) imaging for assessing the equine fetus during the first half of gestation and the possibility of using 3D US imaging of the equine fetus in clinical applications. Seventeen pregnant mares were examined by 3D US between Days 35 and 180 of gestation. Abdominal and endo-vaginal real-time 3D transducers used in human medicine were used for transrectal and transvaginal examinations, respectively. Images were recorded by both 3D stationary and real-time movies. In a comparison of four methods, tra...
1 16 17 18 19 20 35