Analyze Diet

Topic:Biomechanics

Biomechanics in horses refers to the study of the mechanical principles that govern movement and physical function in equine species. This field encompasses the analysis of gait, locomotion, and the forces exerted by and upon the horse's musculoskeletal system. Biomechanical studies often involve the use of motion capture technology, force plates, and computer modeling to assess how horses move and how various factors, such as conformation, training, and health status, influence their performance and soundness. Research in equine biomechanics contributes to understanding injury prevention, rehabilitation, and performance optimization. This page compiles peer-reviewed research studies and scholarly articles that explore the mechanics of movement, the impact of external and internal forces, and the applications of biomechanical analysis in equine care and management.
Re: The effect of hoof angle variations on dorsal lamellar load in the equine hoof.
Equine veterinary journal    June 8, 2012   Volume 44, Issue 4 500 doi: 10.1111/j.2042-3306.2012.00586.x
Curtis S.No abstract available
Re: The effect of hoof angles on dorsal laminae load of the equine hoof.
Equine veterinary journal    June 8, 2012   Volume 44, Issue 4 499-500 doi: 10.1111/j.2042-3306.2012.00584.x
Redden RF.No abstract available
Speed and incline during thoroughbred horse racing: racehorse speed supports a metabolic power constraint to incline running but not to decline running.
Journal of applied physiology (Bethesda, Md. : 1985)    June 7, 2012   Volume 113, Issue 4 602-607 doi: 10.1152/japplphysiol.00560.2011
Self ZT, Spence AJ, Wilson AM.We used a radio tracking system to examine the speed of 373 racehorses on different gradients on an undulating racecourse during 33 races, each lasting a few minutes. Horses show a speed detriment on inclines (0.68 m · s(-1) · 1% gradient(-1), r(2) = 0.97), the magnitude of which corresponds to trading off the metabolic cost (power) of height gain with the metabolic cost (power) of horizontal galloping. A similar relationship can be derived from published data for human runners. The horses, however, were also slower on the decline (-0.45 m · s(-1) · 1% gradient(-1), r(2) = 0.92). Human ath...
Tendon structure changes after maximal exercise in the Thoroughbred horse: use of ultrasound tissue characterisation to detect in vivo tendon response.
Veterinary journal (London, England : 1997)    June 1, 2012   Volume 194, Issue 3 338-342 doi: 10.1016/j.tvjl.2012.04.024
Docking SI, Daffy J, van Schie HT, Cook JL.Investigations into the response of the superficial digital flexor tendon (SDFT) of the Thoroughbred horse to mechanical stimuli have been limited to in vitro cell culture studies focused primarily on gene expression of critical matrix proteins. It is uncertain how well in vitro outcomes translate to the tendon of the horse during exercise. The current study examined changes in tendon structure in response to maximal exercise using ultrasound tissue characterisation (UTC) to scan the SDFT prior to and after competitive racing. UTC uses contiguous transverse ultrasound images to assess the dyna...
Dynamic properties of a dirt and a synthetic equine racetrack surface measured by a track-testing device.
Equine veterinary journal    May 16, 2012   Volume 45, Issue 1 25-30 doi: 10.1111/j.2042-3306.2012.00582.x
Setterbo JJ, Fyhrie PB, Hubbard M, Upadhyaya SK, Stover SM.Racetrack surface is a risk factor for Thoroughbred racehorse injury and death that can be engineered and managed. To investigate the relationship between surface and injury, the mechanical behaviour of dirt and synthetic track surfaces must be quantified. Objective: To compare dynamic properties of a dirt and a synthetic surface in situ using a track-testing device designed to simulate equine hoof impact; and to determine the effects of impact velocity, impact angle and repeated impact on dynamic surface behaviour. Methods: A track-testing device measured force and displacement during impact ...
Morphometrical study of bony elements of the forelimb fetlock joints in horses.
Anatomia, histologia, embryologia    May 10, 2012   Volume 42, Issue 1 9-20 doi: 10.1111/j.1439-0264.2012.01158.x
Alrtib AM, Philip CJ, Abdunnabi AH, Davies HM.There are many reports describing fractures in the bony elements of the equine fetlock joint and a few of these discuss possible relationships of these fractures to the mechanical loading of these bones. The likelihood of fracture must be related to the size and shape of bones involved, but information concerning the normal range in size and shape of these bones in horses is lacking. This study aimed to identify morphometrical variations of these bones within different groups of horses. Right and left metacarpal, proximal phalangeal and proximal sesamoid bones were collected from 10 Thoroughbr...
Comparison of an inertial sensor system of lameness quantification with subjective lameness evaluation.
Equine veterinary journal    May 6, 2012   Volume 44, Issue 6 652-656 doi: 10.1111/j.2042-3306.2012.00571.x
McCracken MJ, Kramer J, Keegan KG, Lopes M, Wilson DA, Reed SK, LaCarrubba A, Rasch M.Subjective evaluation of mild lameness has been shown to have poor interobserver reliability. Traditional methods of objective lameness evaluation require specialised conditions and equipment. Wireless inertial sensor systems have been developed to allow for simple, rapid, objective lameness detection in horses trotted over ground. Objective: The purpose of this study was to compare the sensitivities of an inertial sensor system and subjective evaluation performed by experienced equine practitioners at detecting lameness in horses. We hypothesised that the inertial sensor system would identify...
Proximal hindlimb flexion in the horse: effect on movement symmetry and implications for defining soundness.
Equine veterinary journal    May 6, 2012   Volume 44, Issue 6 657-663 doi: 10.1111/j.2042-3306.2012.00576.x
Starke SD, Willems E, Head M, May SA, Pfau T.Flexion tests are a common tool during the prepurchase and clinical lameness examination, yet studies quantifying the effect of flexion, apart from distal forelimb flexion in sound horses, are sparse. Objective: To investigate the effect of proximal hindlimb flexion on perceivable and measurable changes in movement symmetry in horses with objective movement symmetry falling within the margins of 'sound'. Methods: Thirteen horses, selected based on objective movement symmetry, were instrumented with inertial sensors on left and right tuber coxae and over the os sacrum. Vertical movement symmetr...
The development of clinical tools based on biomechanical research.
Veterinary journal (London, England : 1997)    May 5, 2012   Volume 192, Issue 2 129-130 doi: 10.1016/j.tvjl.2012.02.011
Roepstorff L.No abstract available
A surface roughness comparison of cartilage in different types of synovial joints.
Journal of biomechanical engineering    April 10, 2012   Volume 134, Issue 2 021006 doi: 10.1115/1.4005934
Smyth PA, Rifkin RE, Jackson RL, Hanson RR.The naturally occurring structure of articular cartilage has proven to be an effective means for the facilitation of motion and load support in equine and other animal joints. For this reason, cartilage has been extensively studied for many years. Although the roughness of cartilage has been determined from atomic force microscopy (AFM) and other methods in multiple studies, a comparison of roughness to joint function has not be completed. It is hypothesized that various joint types with different motions and regimes of lubrication have altered demands on the articular surface that may affect ...
Accuracy and precision of hind limb foot contact timings of horses determined using a pelvis-mounted inertial measurement unit.
Journal of biomechanics    April 5, 2012   Volume 45, Issue 8 1522-1528 doi: 10.1016/j.jbiomech.2012.03.014
Starke SD, Witte TH, May SA, Pfau T.Gait analysis using small sensor units is becoming increasingly popular in the clinical context. In order to segment continuous movement from a defined point of the stride cycle, knowledge about footfall timings is essential. We evaluated the accuracy and precision of foot contact timings of a defined limb determined using an inertial sensor mounted on the pelvis of ten horses during walk and trot at different speeds and in different directions. Foot contact was estimated from vertical velocity events occurring before maximum sensor roll towards the contralateral limb. Foot contact timings mat...
Finite element analysis in 3-D models of equine cheek teeth.
Veterinary journal (London, England : 1997)    March 30, 2012   Volume 193, Issue 2 391-396 doi: 10.1016/j.tvjl.2012.02.013
Cordes V, Gardemin M, Lüpke M, Seifert H, Borchers L, Staszyk C.Periodontal diseases occur frequently in equine dentistry and excessive strain in biological tissues is assumed to be a predisposing factor in their development. Finite element (FE) analysis enables strains and stresses occurring in the periodontium to be calculated and is a useful tool for testing this hypothesis. The current study aimed to establish reliable 3-D models from equine maxillary and mandibular cheek teeth for use in FE simulations, with particular attention to the detailed construction of the periodontal ligament (PDL). Age-related morphological aspects of the teeth and the perio...
Resistance of equine tibiae and radii to side impact loads.
Equine veterinary journal    March 20, 2012   Volume 44, Issue 6 714-720 doi: 10.1111/j.2042-3306.2012.00560.x
Piskoty G, Jäggin S, Michel SA, Weisse B, Terrasi GP, Fürst A.There are no detailed studies describing the resistance of equine tibiae and radii to side impact loads, such as a horse kick and a better understanding of the general long bone impact behavioural model is required. Objective: To quantify the typical impact energy required to fracture or fissure an equine long bone, as well as to determine the range and time course of the impact force under conditions similar to that of a horse kick. Methods: Seventy-two equine tibiae and radii were investigated using a drop impact tester. The prepared bones were preloaded with an axial force of 2.5 kN and wer...
Contribution of dynamic calibration to the measurement accuracy of a pressure plate system throughout the stance phase in sound horses.
Veterinary journal (London, England : 1997)    March 3, 2012   Volume 193, Issue 2 471-474 doi: 10.1016/j.tvjl.2012.01.029
Oosterlinck M, Pille F, Sonneveld DC, Oomen AM, Gasthuys F, Back W.The aim of this study was to evaluate the accuracy of the vertical force curve of a pressure plate (PP) using dynamic calibration with a force plate (FP) in six sound Warmblood horses. The animals were walked and trotted over a combined PP-FP system sampling at 250 Hz. Five valid measurements of each forelimb were collected. The recalibration factor (RF), the ratio between the calibrated and raw PP data, was evaluated in each timeframe throughout the stance phase. Following dynamic calibration, the vertical force curve of the PP demonstrated a characteristic biphasic pattern at the walk and ty...
Comparison of an inertial sensor system with a stationary force plate for evaluation of horses with bilateral forelimb lameness.
American journal of veterinary research    March 1, 2012   Volume 73, Issue 3 368-374 doi: 10.2460/ajvr.73.3.368
Keegan KG, MacAllister CG, Wilson DA, Gedon CA, Kramer J, Yonezawa Y, Maki H, Pai PF.To assess the analytic sensitivity of an inertial sensor system for detection of the more severely affected forelimb in horses with bilateral lameness. Methods: 18 adult horses with forelimb lameness. Methods: Horses were fitted with inertial sensors and evaluated for lameness with a stationary force plate as they were trotted in a straight line. Inertial sensor-derived measurements for vertical head movement asymmetry (HMA) and vector sum (VS) of maximum and minimum head height differences between right and left halves of the stride were used to predict differences in mean peak vertical force...
Effects of mineral content on the fracture properties of equine cortical bone in double-notched beams.
Bone    February 25, 2012   Volume 50, Issue 6 1275-1280 doi: 10.1016/j.bone.2012.02.018
McCormack J, Stover SM, Gibeling JC, Fyhrie DP.We recently developed a method to measure cortical bone fracture initiation toughness using a double-notched beam in four-point bending. This method was used to test the hypothesis that mineralization around the two notch roots is correlated with fracture toughness and crack extension (physical damage). Total energy absorbed to failure negatively correlated with average mineralization of the beam (r(2)=0.62), but not with notch root mineralization. Fracture initiation toughness was positively correlated to mineralization at the broken notch root (r(2)=0.34). Crack length extension at the unbro...
Use of a pressure plate to analyse the toe-heel load redistribution underneath a normal shoe and a shoe with a wide toe in sound warmblood horses at the walk and trot.
Research in veterinary science    February 17, 2012   Volume 93, Issue 2 1026-1031 doi: 10.1016/j.rvsc.2012.01.010
Oomen AM, Oosterlinck M, Pille F, Sonneveld DC, Gasthuys F, Back W.The objective of this study was to use a pressure plate to quantify the toe-heel load redistribution in the forelimbs of sound warmblood horses with normal shoes and shoes with a wide toe and narrow branches, used empirically in the treatment of superficial digital flexor tendon or suspensory ligament injuries. In a crossover-design study, six horses, randomly shod with normal shoes and shoes with a wide toe, were led over a dynamically calibrated pressure plate to record data from both forelimbs. There were no significant differences between both shoes in the toe-heel index of stance time, pe...
Comprehensive surface-based morphometry reveals the association of fracture risk and bone geometry.
Journal of orthopaedic research : official publication of the Orthopaedic Research Society    January 17, 2012   Volume 30, Issue 8 1277-1284 doi: 10.1002/jor.22062
Wang D, Shi L, Griffith JF, Qin L, Yew DT, Riggs CM.Surface-based morphometry method is advantageous in its objectivity and increased capability in detecting focal morphological changes, but has not been applied in bone-related research. Orthopedics research in human has confirmed the association of the bone geometry in proximal femur and its fracture. In this study, surface-based morphometry is used to test the hypothesis that there is relationship between bone geometry and fracture risk of the proximal sesamoid bone (PSB) in forelimbs of Thoroughbred racehorses. The PSB surfaces were extracted from CT images of nonfractured forelegs (i.e., ri...
A method to minimise error in 2D-DLT reconstruction of non-planar markers filmed with a moving camera.
Computer methods in biomechanics and biomedical engineering    January 6, 2012   Volume 16, Issue 9 929-936 doi: 10.1080/10255842.2011.644540
Holden-Douilly L, Pourcelot P, Chateau H, Falala S, Crevier-Denoix N.This article describes a method that allows estimating, with the 2D version of the direct linear transformation (DLT), the actual 2D coordinates of a point when the latter is not strictly in the calibration plane. Markers placed in vertical line, above, below and in the centre of a horizontal calibration plane were filmed by a moving camera. Without correction, strong errors (up to 64.5%) were noticed for markers out of the calibration plane. After correction, calculated coordinates were consistent with actual values (error < 0.55%). The method was then applied to slip distance measuremen...
Detection of small tendon lesions by sonoelastographic visualization of strain profile differences: initial experiences.
Skeletal radiology    January 5, 2012   Volume 41, Issue 9 1073-1079 doi: 10.1007/s00256-011-1349-2
Buck AR, Verstraete N, Li Y, Schweizer A, Snedeker JG, Buck FM.To assess the capability of a commercial sonoelastography system to detect small tendon lesions by quantitative analysis of elastogram profiles. Methods: Strips of equine digital flexor tendons were used to model small human tendons. Two tendons were examined. From each tendon, six unmodified tendon strips (controls) and six tendon strips with a central defect of the same tendons were compared. The tendon strips were placed under a physiological tensile strain of 5%. Sonoelastographic visualization of the strain profile was performed. Regions of interest (ROI) were defined left and right of th...
Comparison of pressure distribution under a conventional saddle and a treeless saddle at sitting trot.
Veterinary journal (London, England : 1997)    December 16, 2011   Volume 193, Issue 1 87-91 doi: 10.1016/j.tvjl.2011.11.017
Belock B, Kaiser LJ, Lavagnino M, Clayton HM.It can be a challenge to find a conventional saddle that is a good fit for both horse and rider. An increasing number of riders are purchasing treeless saddles because they are thought to fit a wider range of equine back shapes, but there is only limited research to support this theory. The objective of this study was to compare the total force and pressure distribution patterns on the horse's back with conventional and treeless saddles. The experimental hypotheses were that the conventional saddle would distribute the force over a larger area with lower mean and maximal pressures than the tre...
Stifle extension results in differential tensile forces developing between abaxial and axial components of the cranial meniscotibial ligament of the equine medial meniscus: a mechanistic explanation for meniscal tear patterns.
Equine veterinary journal    December 14, 2011   Volume 44, Issue 5 554-558 doi: 10.1111/j.2042-3306.2011.00532.x
Fowlie JG, Arnoczky SP, Lavagnino M, Stick JA.To identify potential functional-anatomical characteristics of the cranial horn attachment of the medial meniscus (MM) that may help explain the pathogenesis of the common tear patterns that have been reported. Objective: Full extension of the stifle generates a significant increase in tensile forces within the cranial meniscotibial ligament (CrMTL) of the MM, which may predispose this structure to injury. Methods: The effect of femorotibial angle (160°, 150°, 140° and 130°) on tensile forces in the axial and abaxial components of the CrMTL was examined in 6 mature cadaver stifles using an...
Short-term cast immobilisation is effective in reducing lesion propagation in a surgical model of equine superficial digital flexor tendon injury.
Equine veterinary journal    December 5, 2011   Volume 44, Issue 5 570-575 doi: 10.1111/j.2042-3306.2011.00513.x
David F, Cadby J, Bosch G, Brama P, van Weeren R, van Schie H.Larger superficial digital flexor tendon (SDFT) injuries have a poorer prognosis than smaller lesions. During the inflammatory phase enlargement of the initial lesion is frequently noted, with biomechanical loading being recently proposed to play an important role. Objective: To evaluate the effect of lower limb cast immobilisation on tendon lesion propagation in an equine model of surgically induced SDFT injury. Methods: Core lesions were surgically induced in both front SDFTs of 6 young mature horses. At the end of surgery, one leg was randomly placed in a lower limb cast and the other leg (...
Concerted and adaptive alignment of decorin dermatan sulfate filaments in the graded organization of collagen fibrils in the equine superficial digital flexor tendon.
Journal of anatomy    November 28, 2011   Volume 220, Issue 2 156-163 doi: 10.1111/j.1469-7580.2011.01456.x
Watanabe T, Imamura Y, Suzuki D, Hosaka Y, Ueda H, Hiramatsu K, Takehana K.The equine superficial digital flexor tendon (SDFT) has a graded distribution of collagen fibril diameters, with predominantly small-diameter fibrils in the region of the myotendinous junction (MTJ), a gradual increase in large-diameter fibrils toward the osteotendinous junction (OTJ), and a mixture of small- and large-diameter fibrils in the middle metacarpal (MM) region. In this study, we investigated the ultrastructure of the SDFT, to correlate the spatial relationship of the collagen fibrils with the graded distribution. The surface-to-surface distances of pairs of fibrils were found to be...
First application of axial speed of sound to follow up injured equine tendons.
Ultrasound in medicine & biology    November 21, 2011   Volume 38, Issue 1 162-167 doi: 10.1016/j.ultrasmedbio.2011.10.008
Vergari C, Pourcelot P, Ravary-Plumioën B, Dupays AG, Denoix JM, Mitton D, Laugier P, Crevier-Denoix N.Ultrasonography is an established technique to follow up injured tendons, although the lesions' echogenicity tends to become normal before the tendon is ready to sustain the stresses imposed by exercise. Normalized axial speed of sound (SOS) has been found to correlate with an injured tendon's stiffness; therefore, the purpose of this study was to establish whether SOS would be a useful tool in tendon injury follow-up. Axial SOS was measured in 11 equine superficial digital flexor tendons during a 15-week follow-up period and compared with an ultrasonographic grading system. SOS significantly ...
Vertical head and trunk movement adaptations of sound horses trotting in a circle on a hard surface.
Veterinary journal (London, England : 1997)    November 21, 2011   Volume 193, Issue 1 73-80 doi: 10.1016/j.tvjl.2011.10.019
Starke SD, Willems E, May SA, Pfau T.Trotting a horse in circles is a standard and important part of the subjective equine lameness examination, yet objective data on this form of locomotion are sparse. The aim of this study was to investigate the effect of trotting in a circle on head and trunk movement symmetry. Vertical movements of the head, withers, os sacrum and left and right tuber coxae were measured using inertial sensors as 12 sound horses were trotted on a hard surface in a straight line and in a circle on both reins. Seven asymmetry measures and hip hike were calculated for each horse for at least nine strides of comp...
Stirrup forces during horse riding: a comparison between sitting and rising trot.
Veterinary journal (London, England : 1997)    November 18, 2011   Volume 193, Issue 1 193-198 doi: 10.1016/j.tvjl.2011.10.007
van Beek FE, de Cocq P, Timmerman M, Muller M.Injuries of horses might be related to the force the rider exerts on the horse. To better understand the loading of the horse by a rider, a sensor was developed to measure the force exerted by the rider on the stirrups. In the study, five horses and 23 riders participated. Stirrup forces measured in sitting trot and rising trot were synchronised with rider movements measured from digital films and made dimensionless by dividing them by the bodyweight (BW) of the rider. A Fourier transform of the stirrup force data showed that the signals of both sitting and rising trot contained 2.4 and 4.8 Hz...
Gait analysis using 3D accelerometry in horses sedated with xylazine.
Veterinary journal (London, England : 1997)    November 13, 2011   Volume 193, Issue 1 212-216 doi: 10.1016/j.tvjl.2011.10.012
López-Sanromán FJ, Holmbak-Petersen R, Santiago I, Gómez de Segura IA, Barrey E.The aim of the present study was to verify the efficacy and sensitivity of an accelerometric device in detecting and quantifying the degree of movement alteration produced in horses sedated with xylazine. Horses (n=6) were randomly administered either xylazine or a control by intravenous injection, with at least 1 week between each treatment. A triaxial accelerometric device was used for the accelerometric gait assessment 15 min before (baseline) and 5, 15, 30, 45, 60, 75, 90, 105 and 120 min after each treatment. Eight different accelerometric parameters were calculated, including speed, stri...
Axial speed of sound is related to tendon’s nonlinear elasticity.
Journal of biomechanics    November 10, 2011   Volume 45, Issue 2 263-268 doi: 10.1016/j.jbiomech.2011.10.032
Vergari C, Ravary-Plumioën B, Evrard D, Laugier P, Mitton D, Pourcelot P, Crevier-Denoix N.Axial speed of sound (SOS) measurements have been successfully applied to noninvasively evaluate tendon load, while preliminary studies showed that this technique also has a potential clinical interest in the follow up of tendon injuries. The ultrasound propagation theory predicts that the SOS is determined by the effective stiffness, mass density and Poisson's ratio of the propagating medium. Tendon stiffness characterizes the tissue's mechanical quality, but it is often measured in quasi-static condition and for entire tendon segments, so it might not be the same as the effective stiffness w...
[Influence of exercise on horses’ limb volume, measured by an optoelectronic device].
Berliner und Munchener tierarztliche Wochenschrift    November 9, 2011   Volume 124, Issue 5-6 257-264 
Siewert C, Böttcher A, Hellige M, Beyerbach M, von Rautenfeld DB, Seifert H.This study tested for the first time an optoelectronic device (Perometer*) measuring limb volume of horses. An analysis of its application was performed regarding the influence of different types of physical exercise on the volume of the extremities. 40 horses were divided into four groups often horses, each group being exposed to exercise, differing in kind and duration of lunging, horse-ridden and riderless. The volume measurement was performed by determining the inactive value (I) after a twelfe-hour standing period, the load value (II) immediately after exercise and recovery value (III) on...
1 37 38 39 40 41 85