Analyze Diet

Topic:Biomechanics

Biomechanics in horses refers to the study of the mechanical principles that govern movement and physical function in equine species. This field encompasses the analysis of gait, locomotion, and the forces exerted by and upon the horse's musculoskeletal system. Biomechanical studies often involve the use of motion capture technology, force plates, and computer modeling to assess how horses move and how various factors, such as conformation, training, and health status, influence their performance and soundness. Research in equine biomechanics contributes to understanding injury prevention, rehabilitation, and performance optimization. This page compiles peer-reviewed research studies and scholarly articles that explore the mechanics of movement, the impact of external and internal forces, and the applications of biomechanical analysis in equine care and management.
Therapeutic effects of a horse riding simulator in children with cerebral palsy.
Arquivos de neuro-psiquiatria    November 2, 2011   Volume 69, Issue 5 799-804 doi: 10.1590/s0004-282x2011000600014
Silva e Borges MB, Werneck MJ, da Silva Mde L, Gandolfi L, Pratesi R.To evaluate the efficacy of horse ridding simulator on the sitting postural control of children with spastic diplegia. Methods: Forty children were randomly divided in a group using the simulator (RS) and a group performing conventional physical therapy (CT). FScan/Fmat equipment was used to register maximal displacement in antero-posterior (AP) and medio-lateral (ML) directions with children in sitting position. At the pre and post intervention stage both groups were classified according to the Gross Motor Function Classification System (GMFCS) and, after intervention, by the AUQEI questionna...
Biomechanical testing of a novel suture pattern for repair of equine tendon lacerations.
Veterinary surgery : VS    October 31, 2011   Volume 41, Issue 2 278-285 doi: 10.1111/j.1532-950X.2011.00905.x
Everett E, Barrett JG, Morelli J, DeVita R.To compare in vitro biomechanical properties of a novel suture pattern to a current standard for primary repair of equine superficial digital flexor tendon (SDFT) laceration. Methods: In vitro randomized, paired design. Methods: Cadaveric equine forelimb SDFT (n = 24). Methods: The 3-loop pulley (3LP) and 6-strand Savage (SSS) suture patterns were applied to transected equine SDFT. Ultimate failure load, stiffness, mode of failure, and load required to form a 3-mm gap were obtained using a materials testing system and synchronized high-speed video analysis. Statistical comparisons were made us...
Radiographic evaluation of changes in the proximal phalanx of Thoroughbreds in race training.
American journal of veterinary research    October 26, 2011   Volume 72, Issue 11 1482-1488 doi: 10.2460/ajvr.72.11.1482
Beccati F, Pepe M, Di Meo A, Davanzo S, Moriconi F.To evaluate changes in the cortical bone of the proximal phalanx of the fore-limbs of Thoroughbreds in response to training. Methods: Twenty-seven 2-year-old Thoroughbreds (20 females, 2 males, and 5 geldings). Methods: Horses were principally in training for races in a straight line and in a clockwise direction. Lateromedial and dorsopalmar radiographic views of each metacarpophalangeal joint were obtained before the horses started training and 1 year after starting exercise and racing. Width of the dorsal, palmar, lateral, and medial cortex and the width and thickness of the medulla were mea...
Evaluation of biomechanical effects of four stimulation devices placed on the hind feet of trotting horses.
American journal of veterinary research    October 26, 2011   Volume 72, Issue 11 1489-1495 doi: 10.2460/ajvr.72.11.1489
Clayton HM, Lavagnino M, Kaiser LJ, Stubbs NC.To compare effects of 4 types of stimulation devices attached to the hind feet on hoof flight, joint angles, and net joint powers of trotting horses. Methods: 8 clinically normal horses. Methods: Horses were evaluated under 5 conditions in random order: no stimulators, loose straps (10 g), lightweight tactile stimulators (55 g), limb weights (700 g), and limb weights with tactile stimulators (700 g). Reflective markers on the hind limbs were tracked during the swing phase of 6 trotting trials performed at consistent speed to determine peak hoof heights and flexion angles of the hip, stifle, ta...
Axial speed of sound for the monitoring of injured equine tendons: a preliminary study.
Journal of biomechanics    October 22, 2011   Volume 45, Issue 1 53-58 doi: 10.1016/j.jbiomech.2011.10.016
Vergari C, Pourcelot P, Ravary-Plumioën B, Dupays AG, Jacquet S, Audigié F, Denoix JM, Laugier P, Mitton D, Crevier-Denoix N.Equine superficial digital flexor tendons (SDFT) are often injured, and they represent an excellent model for human sport tendinopathies. While lesions can be precisely diagnosed by clinical evaluation and ultrasonography, a prognosis is often difficult to establish; the knowledge of the injured tendon's mechanical properties would help in anticipating the outcome. The objectives of the present study were to compare the axial speed of sound (SOS) measured in vivo in normal and injured tendons and to investigate their relationship with the tendons' mechanical parameters, in order to assess the ...
Morphometrical variations of the carpal bones in thoroughbreds and ponies.
Anatomia, histologia, embryologia    October 20, 2011   Volume 41, Issue 2 139-148 doi: 10.1111/j.1439-0264.2011.01114.x
Abdunnabi AH, Ahmed YA, Philip CJ, Davies HM.There is scant morphological data for equine carpal bones despite the frequent pathology in Thoroughbreds (TB). This study aimed to identify morphological and morphometrical variations and similarities in carpal bones between and within TB and Ponies (Po). Carpal bones from nine TB and 13 Po were prepared by boiling and drying. Lateromedial width, dorsopalmar depth, proximodistal height, relative density and volume of each bone were measured. Normalized measurements of the radial (Cr) and third (C3) carpal bones were significantly different in all dimensions, and there were significant variati...
Relationships between in vivo microdamage and the remarkable regional material and strain heterogeneity of cortical bone of adult deer, elk, sheep and horse calcanei.
Journal of anatomy    September 26, 2011   Volume 219, Issue 6 722-733 doi: 10.1111/j.1469-7580.2011.01428.x
Skedros JG, Sybrowsky CL, Anderson WE, Chow F.Natural loading of the calcanei of deer, elk, sheep and horses produces marked regional differences in prevalent/predominant strain modes: compression in the dorsal cortex, shear in medial-lateral cortices, and tension/shear in the plantar cortex. This consistent non-uniform strain distribution is useful for investigating mechanisms that mediate the development of the remarkable regional material variations of these bones (e.g. collagen orientation, mineralization, remodeling rates and secondary osteon morphotypes, size and population density). Regional differences in strain-mode-specific micr...
Resection of Grade III cranial horn tears of the equine medial meniscus alter the contact forces on medial tibial condyle at full extension: an in-vitro cadaveric study.
Veterinary surgery : VS    September 23, 2011   Volume 40, Issue 8 957-965 doi: 10.1111/j.1532-950X.2011.00899.x
Fowlie J, Arnoczky S, Lavagnino M, Maerz T, Stick J.To evaluate the magnitude and distribution of joint contact pressure on the medial tibial condyle after grade III cranial horn tears of the medial meniscus. Methods: Experimental study. Methods: Cadaveric equine stifles (n = 6). Methods: Cadaveric stifles were mounted in a materials testing system and electronic pressure sensors were placed between the medial tibial condyle and medial meniscus. Specimens were loaded parallel to the longitudinal axis of the tibia to 1800 N at 130°, 140°, 150°, and 160° stifle angle. Peak pressure and contact area were recorded from the contact maps. Testing...
Movement associated reduction of spatial capacity of the equine cervical vertebral canal.
Veterinary journal (London, England : 1997)    September 14, 2011   Volume 192, Issue 3 525-528 doi: 10.1016/j.tvjl.2011.08.011
Schmidburg I, Pagger H, Zsoldos RR, Mehnen J, Peham C, Licka TF.Laterolateral radiographs of equine necks are reported to be inaccurate in determining the site of spinal cord lesions even when a myelogram is carried out. The goal of this study was to assess constrictions present in the cervical vertebral canal at any time point throughout the extremes of movement. Sixteen equine cervical vertebral columns without history of cervical disease were used. After removal of the spinal cord, the dura mater was filled with polyurethane foam and during its plastic phase the cervical vertebral column was passively moved in flexion-extension, lateral bending and 30°...
Assessment of repeatability of a wireless, inertial sensor-based lameness evaluation system for horses.
American journal of veterinary research    September 2, 2011   Volume 72, Issue 9 1156-1163 doi: 10.2460/ajvr.72.9.1156
Keegan KG, Kramer J, Yonezawa Y, Maki H, Pai PF, Dent EV, Kellerman TE, Wilson DA, Reed SK.To determine repeatability of a wireless, inertial sensor-based lameness evaluation system in horses. Methods: 236 horses. Methods: Horses were from 2 to 29 years of age and of various breeds and lameness disposition. All horses were instrumented with a wireless, inertial sensor-based motion analysis system on the head (accelerometer), pelvis (midline croup region [accelerometer]), and right forelimb (gyroscope) before evaluation in 2 consecutive trials, approximately 5 minutes apart, as the horse was trotted in a straight line. Signal-processing algorithms generated overall trial asymmetry me...
Propagation of two longitudinal waves in a cancellous bone with the closed pore boundary.
The Journal of the Acoustical Society of America    September 1, 2011   Volume 130, Issue 2 EL122-EL127 doi: 10.1121/1.3607196
Mizuno K, Nagatani Y, Yamashita K, Matsukawa M.Ultrasound propagation in cancellous bone (porous media) under the condition of closed pore boundaries was investigated. A cancellous bone and two plate-like cortical bones obtained from a racehorse were prepared. A water-immersion ultrasound technique in the MHz range and a three-dimensional elastic finite-difference time-domain (FDTD) method were used to investigate the waves. The experiments and simulations showed a clear separation of the incident longitudinal wave into fast and slow waves. The findings advance the evaluation of bones based on the two-wave phenomenon for in vivo assessment...
Is a single force plate adequate for stabilographic analysis in horses?
Equine veterinary journal    August 26, 2011   Volume 44, Issue 5 550-553 doi: 10.1111/j.2042-3306.2011.00458.x
Clayton HM, Nauwelaerts S.Postural balance can be quantified using stabilographic variables derived from force plate data that describe movements of the horse's centre of pressure (COP) in the horizontal plane. Most force plates are not large enough to accommodate all 4 limbs of a standing horse, so the study was designed to assess whether representative stabilographic data could be collected from the forelimbs or hindlimbs. Objective: To determine whether stabilographic data from either the forelimbs or the hindlimbs were representative of data for the total body. Methods: Stabilographic data (960 Hz) were collected...
Possible role of carpal hyperextension in superficial digital flexor tendinopathy.
Equine veterinary journal    August 26, 2011   Volume 44, Issue 5 559-563 doi: 10.1111/j.2042-3306.2011.00466.x
Whitlock D, Garcia TC, Vallance SA, Stover SM.The specific biomechanical circumstances that induce excessive superficial digital flexor tendon (SDFT) strain in horses are unknown. Objective: Carpal joint hyperextension during axial limb loading during the middle of stance disproportionately enhances SDFT strains compared to suspensory ligament (SL) strains. Methods: Superficial digital flexor tendon and SL strains were measured in 7 cadaver limbs during in vitro loading that maintained carpal extension or allowed carpal hyperextension by constraining, or allowing rotation of, the radius during loading conditions that simulated the middle ...
Proceedings of the 8th International Conference on Equine Exercise Physiology. November 7-12, 2010. Cape Town, South Africa.
Equine veterinary journal. Supplement    August 19, 2011   Issue 38 1-702 
No abstract available
The effect of previous conditioning exercise on diaphyseal and metaphyseal bone to imposition and withdrawal of training in young Thoroughbred horses.
Veterinary journal (London, England : 1997)    August 19, 2011   Volume 192, Issue 1 34-40 doi: 10.1016/j.tvjl.2011.05.016
Firth EC, Rogers CW, van Weeren PR, Barneveld A, McIlwraith CW, Kawcak CE, Goodship AE, Smith RK.This study recorded the response to training of the diaphysis of the proximal phalangeal bone and the third metacarpal bone (Mc3) and the Mc3 proximal metaphysis. Nineteen 2- and 3-year old horses in training were exposed either to spontaneous exercise at pasture (PASTEX group) or additional imposed exercise (CONDEX group) from a very young age. Quantitative computed tomography scans were analysed for bone mineral content, size, bone mineral density, periosteal and endosteal circumference, cortical thickness and an estimate of bone strength. The bones of the CONDEX horses were bigger and stron...
In vitro electrical activity of the equine pelvic flexure.
Equine veterinary journal. Supplement    August 4, 2011   Issue 39 145-148 doi: 10.1111/j.2042-3306.2011.00396.x
Fintl C, Pearson GT, Mayhew IG, Hudson NP.The generation and maintenance of intestinal motility patterns involve the complex interactions of several components including the gastrointestinal pacemaker cells (interstitial cells of Cajal, ICC). Central to ICC function is the generation of rhythmic pacemaker currents, namely slow waves, which represent the rate limiting step for intestinal smooth muscle contractions. Currently, intracellular slow wave activity has not been demonstrated in the equine colon. Objective: To characterise the in vitro myoelectrical activity of the equine pelvic flexure using intracellular recording techniques....
Method to calibrate phase fluctuation in polarization-sensitive swept-source optical coherence tomography.
Journal of biomedical optics    August 3, 2011   Volume 16, Issue 7 070502 doi: 10.1117/1.3597721
Lu Z, Kasaragod DK, Matcher SJ.We present a phase fluctuation calibration method for polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) using continuous polarization modulation. The method uses a low-voltage broadband polarization modulator driven by a synchronized sinusoidal burst waveform rather than an asynchronous waveform, together with the removal of the global phases of the measured Jones matrices by the use of matrix normalization. This makes it possible to average the measured Jones matrices to remove the artifact due to the speckle noise of the signal in the sample without introducing aux...
A cryogenic clamping technique that facilitates ultimate tensile strength determinations in tendons and ligaments.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    July 21, 2011   Volume 24, Issue 5 370-373 doi: 10.3415/VCOT-10-09-0128
Bowser JE, Elder SH, Rashmir-Raven AM, Swiderski CE.To describe the use of a cryogenic clamp of novel design for tensile strength testing of tendinous and ligamentous tissues with inherently high tensile strength. Methods: Inexpensive, easily machined steel clamps were manufactured to facilitate rapid insertion into a standard wedge-screw grip apparatus installed on a testing system with a control system attached. The deep digital flexor tendon (DDFT) of six horses was trimmed to a uniform dumbbell shape and secured in clamps using partial submersion in liquid nitrogen for approximately 45 seconds and immediately tested. Approximate time betwee...
An ex vivo biomechanical study comparing strength characteristics of a new technique with the three-loop pulley for equine tenorrhaphy.
Veterinary surgery : VS    July 19, 2011   Volume 40, Issue 6 768-773 doi: 10.1111/j.1532-950X.2011.00856.x
Smith RL, Murphy DJ, Day RE, Lester GD.To test single cycle to failure tensile strength characteristics of 6 suture material-pattern combinations in equine superficial digital flexor (SDF) tenorrhaphy, specifically to compare a 10-strand modification of the Savage core suture technique with the 3-loop pulley technique. Methods: Ex vivo mechanical experiment comparing 3 different suture patterns with 2 different materials. Methods: Forelimb and hindlimb SDF tendons (n=48) harvested from adult Thoroughbred and Standardbred horses of mixed age and gender. Methods: Six suture material-pattern combinations were evaluated: (1) 10-strand ...
The effect of lateral heel studs on the kinematics of the equine digit while cantering on grass.
Veterinary journal (London, England : 1997)    July 12, 2011   Volume 192, Issue 2 217-221 doi: 10.1016/j.tvjl.2011.06.003
Harvey AM, Williams SB, Singer ER.This study aimed to assess the effect of lateral heel studs on foot-ground interaction in the horse by quantifying foot slip during stance whilst cantering on a grass surface. It was hypothesised that using studs would decrease foot slip distance on the ground conditions tested. Nine horses were ridden with and without a stud placed laterally in the shoe of each of the 4 feet. High speed video-analysis was used to track hoof markers and to provide data quantifying foot slip distance, slip duration and stance duration. Using studs resulted in a significant decrease in foot slip distance in all ...
Sole depth and weight-bearing characteristics of the palmar surface of the feet of feral horses and domestic Thoroughbreds.
American journal of veterinary research    June 2, 2011   Volume 72, Issue 6 727-735 doi: 10.2460/ajvr.72.6.727
Hampson BA, Connelley AD, de Laat MA, Mills PC, Pollitt CC.To determine solar load-bearing structures in the feet of feral horses and investigate morphological characteristics of the sole in feral horses and domestic Thoroughbreds. Methods: Forelimbs from cadavers of 70 feral horses and 20 domestic Thoroughbreds in Australia. Methods: Left forefeet were obtained from 3 feral horse populations from habitats of soft substrate (SS [n = 10 horses]), hard substrate (HS [10]), and a combination of SS and HS (10) and loaded in vitro. Pressure distribution was measured with a pressure plate. Sole depth was measured at 12 points across the solar plane in feet ...
Cartilage damage involving extrusion of mineralisable matrix from the articular calcified cartilage and subchondral bone.
European cells & materials    May 28, 2011   Volume 21 470-478 doi: 10.22203/ecm.v021a35
Boyde A, Riggs CM, Bushby AJ, McDermott B, Pinchbeck GL, Clegg PD.Arthropathy of the distal articular surfaces of the third metacarpal (Mc3) and metatarsal (Mt3) bones in the Thoroughbred racehorse (Tb) is a natural model of repetitive overload arthrosis. We describe a novel pathology that affects the articular calcified cartilage (ACC) and subchondral bone (SCB) and which is associated with hyaline articular cartilage degeneration. Parasagittal slices cut from the palmar quadrant of the distal condyles of the left Mc3/Mt3 of 39 trained Tbs euthanized for welfare reasons were imaged by point projection microradiography, and backscattered electron (BSE) scann...
A preliminary model study of the equine back including activity of longissimus dorsi muscle.
Equine veterinary journal. Supplement    May 27, 2011   Issue 38 401-406 doi: 10.1111/j.2042-3306.2010.00282.x
Groesel M, Zsoldos RR, Kotschwar A, Gfoehler M, Peham C.Identifying the underlying problem of equine back pain and diseases of the spine are significant problems in veterinary orthopaedics. A study to validate a preliminary biomechanical model of the equine back based on CT images including longissimus dorsi (LD) muscle is therefore important. Objective: Validation of the back model by comparing the shortening of LD muscles in the model with integrated EMG (IEMG) at stance during induced lateral flexion of the spine. Methods: Longissimus dorsi muscle activity at stance has been used for validation. EMG electrodes were placed laterally at the level ...
Heel effects on joint contact force components in the equine digit: a sensitivity analysis.
Equine veterinary journal. Supplement    May 27, 2011   Issue 38 475-481 doi: 10.1111/j.2042-3306.2010.00221.x
Noble P, Lejeune JP, Caudron I, Lejeune P, Collin B, Denoix JM, Serteyn D.Whereas the effect of heel configuration on the tension of the suspensory apparatus is well documented in the literature, there are few reports of joint contact force components in the equine distal forelimb. Objective: To improve understanding of the effect of heel configuration on equine digit joint loading, a sensitivity analysis was performed to compare the effect of a raised heel on joint contact force components in the coffin and fetlock joints during the stance phase of the trot. Methods: Four Warmblood horses were used. An inverse dynamic analysis was carried out using kinematic and ki...
The effect of water height on stride frequency, stride length and heart rate during water treadmill exercise.
Equine veterinary journal. Supplement    May 27, 2011   Issue 38 662-664 doi: 10.1111/j.2042-3306.2010.00194.x
Scott R, Nankervis K, Stringer C, Westcott K, Marlin D.Water treadmill exercise is often incorporated into rehabilitation programmes for horses yet little is known about the biomechanical and physiological responses to water walking. Objective: To establish whether stride frequency (SF) reached steady state as a result of 6 introductory water treadmill sessions and then to investigate the effect of increasing water height on SF, stride length (SL) and heart rate (HR). Methods: Nine horses with no previous experience of water treadmills completed 6 sessions of walking for between 15 and 30 min. Each horse was fitted with a leg mounted accelerometer...
A preliminary modelling study on the equine cervical spine with inverse kinematics at walk.
Equine veterinary journal. Supplement    May 27, 2011   Issue 38 516-522 doi: 10.1111/j.2042-3306.2010.00265.x
Zsoldos RR, Groesel M, Kotschwar A, Kotschwar AB, Licka T, Peham C.The motion of the atlanto-occipital, cervical vertebral and cervicothoracic joints play an important role in equestrian sports and they are also common sites for lesions limiting performance in horses. Objective: To calculate inverse kinematics based on cervical vertebral motion and to develop a model close to the measured neck movements. Methods: Measurements were recorded in 6 horses without neck pain. Reflective markers were placed on both cristae facialis, both sides of cervical vertebra 1, 3 and 6 on the withers and hooves. The neck model was reconstructed from CT scans of the osseus stru...
The association of various speed indices to training responses in Thoroughbred flat racehorses measured with a global positioning and heart rate monitoring system.
Equine veterinary journal. Supplement    May 27, 2011   Issue 38 51-57 doi: 10.1111/j.2042-3306.2010.00272.x
Fonseca RG, Kenny DA, Hill EW, Katz LM.Fitness assessment can be challenging. The use of global positioning systems (GPS) with heart rate (HR) monitors has been promising; however, evaluation of speed parameters during training has not been reported. Objective: To evaluate speed indices during training in Thoroughbreds using a GPS-HR monitor. Methods: Thoroughbreds (n = 102) were assessed during training with data collected each work day (WD; sprinting). Speed indices evaluated included maximal velocity (V(max)), duration at V(max) (V(maxt)), acceleration rate (m/s(2)) from 800 m to V(max) (Acc800-V(max)), the distance (m) 6 (V(max...
Heel movement in horses: comparison between glued and nailed horse shoes at different speeds.
Equine veterinary journal. Supplement    May 27, 2011   Issue 38 431-435 doi: 10.1111/j.2042-3306.2010.00243.x
Yoshihara E, Takahashi T, Otsuka N, Isayama T, Tomiyama T, Hiraga A, Wada S.It has been suggested that the heel of the horse's hoof expands in the stance phase and this reduces the concussion at impact and helps pump blood into the hoof. Therefore, farriers usually leave a gap in the heel region when using the traditional nailed shoe. Recently glued shoes which are attached firmly to the heel have been developed and these could restrict heel movement. Objective: To compare the degree of mediolateral heel movement between glued and nailed shoes. Methods: Seven Thoroughbreds were used. Either their fore- or hind hooves were shod with plain aluminium shoes, attached firs...
Oxygen consumption and gait variables of Arabian endurance horses measured during a field exercise test.
Equine veterinary journal. Supplement    May 27, 2011   Issue 38 1-5 doi: 10.1111/j.2042-3306.2010.00184.x
Cottin F, Metayer N, Goachet AG, Julliand V, Slawinski J, Billat V, Barrey E.Arabian horses have morphological, muscular and metabolic features designed for endurance races. Their gas exchange and gait variables were therefore measured during a field exercise test. This study presents original respiratory and locomotor data recorded in endurance horses under field conditions. Objective: Respiratory gas exchange ratio (RER) of Arabian horses at the speed required to win endurance races (18 km/h for 120-160 km) are <1 and running economy (RE) is also low in order to maintain exercise intensity using aerobic metabolism for long intervals. The purpose of this study was to ...
Influence of shoes with different weights on the motion of the limbs in Icelandic horses during toelt at different speeds.
Equine veterinary journal. Supplement    May 27, 2011   Issue 38 451-454 doi: 10.1111/j.2042-3306.2010.00231.x
Rumpler B, Riha A, Licka T, Kotschwar A, Peham C.Weight boots are commonly used for Icelandic horses to increase the height of the flight arc of the forelimbs in toelt. Objective: To show the influence of weights and toelting speed on the height of the swing phase. Methods: Eight Icelandic horses (mean ± s.d. 12 ± 3 years old, 369 ± 46 kg) were used. Reflecting makers were placed on the dorsal side of each hoof. The motion was collected with a kinematic system (10 cameras, 120 Hz sample rate, 1.3 Mpixels resolution). The horses were ridden in toelt by 2 experienced riders on a treadmill at 2 different speeds (2.96 m/s ± 0.30 and 4.10 m/s...