Analyze Diet

Topic:Biomechanics

Biomechanics in horses refers to the study of the mechanical principles that govern movement and physical function in equine species. This field encompasses the analysis of gait, locomotion, and the forces exerted by and upon the horse's musculoskeletal system. Biomechanical studies often involve the use of motion capture technology, force plates, and computer modeling to assess how horses move and how various factors, such as conformation, training, and health status, influence their performance and soundness. Research in equine biomechanics contributes to understanding injury prevention, rehabilitation, and performance optimization. This page compiles peer-reviewed research studies and scholarly articles that explore the mechanics of movement, the impact of external and internal forces, and the applications of biomechanical analysis in equine care and management.
Linear kinematics at take-off in horses jumping the wall in an international Puissance competition.
Sports biomechanics    September 6, 2005   Volume 4, Issue 2 149-162 doi: 10.1080/14763140508522860
Powers P.Sagittal plane SVHS video recordings (50 Hz) were made of horses jumping the wall at an international Puissance competition. Video sequences were manually digitized and six kinematic variables at take-off were analyzed. Nine horses started the competition with the fence height at 1.80 m, and two horses attempted the fence in the fifth and final round with the fence height at 2.27 m. For successful performances, fence height was correlated with the following take-off variables: vertical velocity of the centre of mass (r = 0.45, p = 0.03); height of centre of mass (r = 0.44, p = 0.04); distance ...
Can jumping capacity of adult show jumping horses be predicted on the basis of submaximal free jumps at foal age? A longitudinal study.
Veterinary journal (London, England : 1997)    September 1, 2005   Volume 170, Issue 2 212-221 doi: 10.1016/j.tvjl.2004.06.009
Bobbert MF, Santamaría S, van Weeren PR, Back W, Barneveld A.The purpose of this study was to quantify performance characteristics of good jumping horses, and to determine whether these were already detectable at foal age. Kinematic data were collected of horses performing free jumps over a 0.60 m high fence at six months of age and of these same horses jumping with a rider over a 1.15 m high fence at five years of age. At five years of age the horses were divided into three groups on the basis of a puissance competition: a group of seven best jumpers that made no errors and in the end cleared a 1.50 m high fence, a group of nine worst jumpers that were...
Mechanical and functional properties of the equine superficial digital flexor tendon.
Veterinary journal (London, England : 1997)    September 1, 2005   Volume 170, Issue 2 184-192 doi: 10.1016/j.tvjl.2004.03.021
Dowling BA, Dart AJ.The in vitro and in vivo mechanical properties of the superficial digital flexor tendon have been described. To date the focus has been on single load to failure testing, however refined in vivo methods may prove useful to evaluate the effects of treatment and exercise on tendons. During maximal exercise, the adult superficial digital flexor tendon operates close to its functional limits with a narrow biomechanical safety margin. This combined with exercise and age associated microdamage, and a limited adaptive ability may increase the risk of fatigue failure. Studies evaluating treatment regi...
Respiratory mechanics in Standardbred horses with sub-clinical inflammatory airway disease and poor athletic performance.
Veterinary journal (London, England : 1997)    August 29, 2005   Volume 173, Issue 1 144-150 doi: 10.1016/j.tvjl.2005.07.020
Pirrone F, Albertini M, Clement MG, Lafortuna CL.The aim of this study was to investigate and quantify respiratory mechanical dysfunctions in Standardbred horses with both poor performance and bronchoalveolar lavage fluid cytology characteristic of inflammatory airway disease (IAD). A control group of healthy Standardbred horses was compared. Respiratory mechanics and breathing pattern were examined at rest and during hyperventilation induced using a rebreathing method. At rest, respiratory mechanics and breathing pattern were superimposable in both groups. In IAD horses, rebreathing increased ventilation, with larger tidal volumes and lower...
Effects of recombinant equine growth hormone on in vitro biomechanical properties of the superficial digital flexor tendon of Standardbred yearlings in training.
Veterinary surgery : VS    August 24, 2005   Volume 34, Issue 3 253-259 doi: 10.1111/j.1532-950X.2005.00038.x
Gerard MP, Hodgson DR, Rose RJ, Walsh WR.To determine whether recombinant equine growth hormone (rEGH) would alter the in vitro biomechanical properties of the forelimb superficial digital flexor tendon (SDFT) in exercising young Standardbred horses. Methods: Randomized complete block design. Methods: Twelve Standardbred yearlings. Methods: Horses were trained for 12 weeks on a high-speed treadmill (10% positive incline). rEGH was administered intramuscularly (IM) daily (10 microg/kg during week 4; 20 microg/kg for weeks 5-9) to 6 horses (treated group), whereas 6 horses (control group) were administered an equivalent daily volume of...
Assessment of stiffness and strength of 4 different implants available for equine fracture treatment: a study on a 20 degrees oblique long-bone fracture model using a bone substitute.
Veterinary surgery : VS    August 24, 2005   Volume 34, Issue 3 231-238 doi: 10.1111/j.1532.950X.2005.00035.x
Florin M, Arzdorf M, Linke B, Auer JA.To compare the mechanical properties of 4 stabilization methods for equine long-bone fractures: dynamic compression plate (DCP), limited contact-DCPlate (LC-DCP), locking compression plate (LCP), and the clamp-rod internal fixator (CRIF--formerly VetFix). Methods: In vitro mechanical study. Methods: Bone substitute material (24 tubes) was cut at 20 degrees to the long axis of the tube to simulate an oblique mid-shaft fracture. Methods: Tubes were divided into 4 groups (n=6) and double plated in an orthogonal configuration, with 1 screw of 1 implant being inserted in lag fashion through the "fr...
Influence of age, site, and degenerative state on the speed of sound in equine articular cartilage.
American journal of veterinary research    August 23, 2005   Volume 66, Issue 7 1175-1180 doi: 10.2460/ajvr.2005.66.1175
Brommer H, Laasanen MS, Brama PA, van Weeren PR, Barneveld A, Helminen HJ, Jurvelin JS.To determine the speed of sound (SOS) in equine articular cartilage and investigate the influence of age, site in the joint, and cartilage degeneration on the SOS. Methods: Cartilage samples from 38 metacarpophalangeal joints of 38 horses (age range, 5 months to 22 years). Methods: Osteochondral plugs were collected from 2 articular sites of the proximal phalanx after the degenerative state was characterized by use of the cartilage degeneration index (CDI) technique. The SOS was calculated (ratio of needle-probe cartilage thickness to time of flight of the ultrasound pulse), and relationships ...
Biochemical analysis of the articular cartilage and subchondral and trabecular bone of the metacarpophalangeal joint of horses with early osteoarthritis.
American journal of veterinary research    August 23, 2005   Volume 66, Issue 7 1238-1246 doi: 10.2460/ajvr.2005.66.1238
van der Harst MR, DeGroot J, Kiers GH, Brama PA, van de Lest CH, van Weeren PR.To assess whether site-related changes in biochemical composition are present in the cartilage and subchondral and trabecular bone of the metacarpophalangeal joint of horses with early osteoarthritis. Methods: Right metacarpophalangeal joints from 59 mature warmblood horses. Methods: Biochemical data (cross-link, amino acid, DNA, and ash contents; denatured collagen and glycosaminoglycan [GAG] concentrations; bone mineral density; and mineral composition) were obtained from 2 differently loaded sites of phalanx I cartilage and subchondral and trabecular bone samples; data were compared with pr...
Extracellular matrix composition of the equine superficial digital flexor tendon: relationship with age and anatomical site.
Journal of veterinary medicine. A, Physiology, pathology, clinical medicine    August 20, 2005   Volume 52, Issue 7 333-338 doi: 10.1111/j.1439-0442.2005.00742.x
Lin YL, Brama PA, Kiers GH, van Weeren PR, DeGroot J.The objectives of the present study were to test the hypotheses that: (1) the composition of the extracellular matrix of the equine superficial digital flexor tendon (SDFT) shows great functional similarities with articular cartilage, i.e. that significant differences exist in biochemical composition of differently loaded areas (which in the case of tendons may be more apparent as tendon shows more obvious differences than cartilage); and (2) that, as in articular cartilage, no substantial alterations in biochemical composition take place during ageing once adulthood has been attained. Tendon ...
Biochemical and biomechanical properties of lesion and adjacent articular cartilage after chondral defect repair in an equine model.
The American journal of sports medicine    August 10, 2005   Volume 33, Issue 11 1647-1653 doi: 10.1177/0363546505275487
Strauss EJ, Goodrich LR, Chen CT, Hidaka C, Nixon AJ.Chondral defects may lead to degradative changes in the surrounding cartilage, predisposing patients to developing osteoarthritis. Objective: To quantify changes in the biomechanical and biochemical properties of the articular cartilage adjacent to chondral defects after experimental defect repair. Methods: Controlled laboratory study. Methods: Specimens were harvested from tissue within (lesion), immediately adjacent to, and at a distance from (remote area) a full-thickness cartilage defect 8 months after cartilage repair with genetically modified chondrocytes expressing insulin-like growth f...
A non-invasive method of tendon force measurement.
Journal of biomechanics    August 9, 2005   Volume 38, Issue 10 2124-2129 doi: 10.1016/j.jbiomech.2004.09.012
Pourcelot P, Defontaine M, Ravary B, Lemâtre M, Crevier-Denoix N.The ability to measure the forces exerted in vivo on tendons and, consequently, the forces produced by muscles on tendons, offers a unique opportunity to investigate questions in disciplines as varied as physiology, biomechanics, orthopaedics and neuroscience. Until now, tendon loads could be assessed directly only by means of invasive sensors implanted within or attached to these collagenous structures. This study shows that the forces acting on tendons can be measured, in a non-invasive way, from the analysis of the propagation of an acoustic wave. Using the equine superficial digital flexor...
Design and demonstration of a dynamometric horseshoe for measuring ground reaction loads of horses during racing conditions.
Journal of biomechanics    August 9, 2005   Volume 38, Issue 10 2102-2112 doi: 10.1016/j.jbiomech.2004.08.024
Roland ES, Hull ML, Stover SM.Because musculoskeletal injuries to racehorses are common, instrumentation for the study of factors (e.g. track surface), which affect the ground reaction loads in horses during racing conditions, would be useful. The objectives of the work reported by this paper were to (1) design and construct a novel dynamometric horseshoe that is capable of measuring the complete ground reaction loading during racing conditions, (2) characterize static and dynamic measurement errors, and (3) demonstrate the usefulness of the instrument by collecting example data during the walk, trot, canter, and gallop fo...
Linear and temporal stride characteristics of 3-day event horses at a CCI*** 3-day event horse inspection.
New Zealand veterinary journal    July 21, 2005   Volume 47, Issue 6 193-197 doi: 10.1080/00480169.1999.36142
Rogers CW, Davies AS, Pfeiffer DU, Davie PS.To quantify the linear and temporal characteristics of the trot of 3-day event horses during the preliminary horse inspection of an advanced grade CCI*** 3-day event. Methods: A cross sectional study was made of the kinematics of 24 3-day-event horses during the first horse inspection at a CCI*** level S-day event. Video footage was digitised and linear and temporal measurements were made. Results: The horses trotted for an average of 10.44+/-1.55 strides. Spatial measurements were made on an average of 5.66+/-0.92 consecutive strides when the horses were within the calibration zone. The horse...
Saddle pressure measuring: validity, reliability and power to discriminate between different saddle-fits.
Veterinary journal (London, England : 1997)    July 12, 2005   Volume 172, Issue 2 265-273 doi: 10.1016/j.tvjl.2005.05.009
de Cocq P, van Weeren PR, Back W.Saddle-fit is recognised as an important factor in the pathogenesis of back problems in horses and is empirically being evaluated by pressure measurements in clinical practice, although not much is known about the validity, reliability and usability of these devices in the equine field. This study was conducted to assess critically a pressure measurement system marketed for evaluating saddle fit. Validity was tested by calculating the correlation coefficient between total measured pressure and the weight of 28 different riders. Reliability and discriminative power with respect to different sad...
Osteon interfacial strength and histomorphometry of equine cortical bone.
Journal of biomechanics    July 12, 2005   Volume 39, Issue 9 1629-1640 doi: 10.1016/j.jbiomech.2005.05.006
Bigley RF, Griffin LV, Christensen L, Vandenbosch R.The interfacial strength of secondary osteons from the diaphysis of the Thoroughbred equine third metacarpal was evaluated using the fiber pushout test. The pushout was performed on 300-500 microm sections of 4x4x15 mm bone blocks machined from four anatomic regions of the cortex. Pushout strength was evaluated from proximal to distal location within the diaphysis on four osteon types classified under polarized light on adjacent histologic sections from each block. The shear strength of the interfaces were estimated from shear lag theory. Differences were found in the interfacial strength of o...
Femoral asymmetry in the Thoroughbred racehorse.
Australian veterinary journal    July 1, 2005   Volume 83, Issue 6 367-370 doi: 10.1111/j.1751-0813.2005.tb15636.x
Pearce GP, May-Davis S, Greaves D.To investigate the occurrence of geometrical asymmetries in the macro-architecture of left and right femurs from Thoroughbred racehorses previously used in competitive training and racing in New South Wales, Australia. Methods: Detailed postmortem measurements were made of 37 characteristics of left and right femurs from eleven Thoroughbred racehorses euthanased for reasons unrelated to the study. Measurements focused on articulating surfaces and sites of attachment of muscles and ligaments known to be associated with hindlimb locomotion. Results: Five measurements were significantly larger in...
An in vitro study on spontaneous myometrial contractility in the mare during estrus and diestrus.
Theriogenology    July 1, 2005   Volume 65, Issue 3 517-527 doi: 10.1016/j.theriogenology.2005.05.048
Hirsbrunner G, Reist M, Couto SS, Steiner A, Snyder J, Vanleeuwen E, Liu I.Uterine smooth muscle specimens were collected from euthanatized mares in estrus and diestrus. Longitudinal and circular specimens were mounted in organ baths and the signals transcribed to a Grass polygraph. After equilibration time and 2 g preload, their physiologic isometric contractility was recorded for a continuous 2.0 h. Area under the curve, frequency and time occupied by contractions were studied. Differences between cycle phases, between muscle layers, and over the recorded time periods were statistically evaluated using linear mixed-effect models. In the mare, physiologic contractil...
Comparison of girth materials, girth tensions and their effects on performance in racehorses.
Australian veterinary journal    June 24, 2005   Volume 83, Issue 1-2 68-74 doi: 10.1111/j.1751-0813.2005.tb12200.x
Bowers J, Slocombe RF.To compare the effect of girth materials and commonly used girth tensions on athletic performance of race-horses and to test the length tension properties of commercially available girths. Methods: Seven horses were exercised at speeds to produce 95% of maximal heart rates on 15 occasions using a randomised block design, and girthed with 5 different girths at 3 nominal tensions of 6, 12 or 18 kg. The girths used were a standard elastic race girth, an 'American' elastic race girth, an elastic race girth twice the normal width, a standard canvas race girth and a canvas race girth at twice the no...
Musculoskeletal modeling and dynamic simulation of the thoroughbred equine forelimb during stance phase of the gallop.
Journal of biomechanical engineering    June 24, 2005   Volume 127, Issue 2 318-328 doi: 10.1115/1.1865196
Swanstrom MD, Zarucco L, Hubbard M, Stover SM, Hawkins DA.Because thoroughbred racehorses have a high incidence of forelimb musculoskeletal injuries, a model was desired to screen potential risk factors for injuries. This paper describes the development of a musculoskeletal model of the thoroughbred forelimb and a dynamic simulation of the motion of the distal segments during the stance phase of high-speed (18 m/s) gallop. The musculoskeletal model is comprised of segment, joint, muscle-tendon, and ligament information. The dynamic simulation incorporates a proximal forward-driving force, a distal ground reaction force model, muscle activations, and ...
A method for deriving displacement data during cyclical movement using an inertial sensor.
The Journal of experimental biology    June 18, 2005   Volume 208, Issue Pt 13 2503-2514 doi: 10.1242/jeb.01658
Pfau T, Witte TH, Wilson AM.Biomechanical studies often employ optical motion capture systems for the determination of the position of an object in a room-based coordinate system. This is not ideal for many types of study in locomotion since only a few strides may be collected per ;trial', and outdoor experiments are difficult with some systems. Here, we report and evaluate a novel approach that enables the user to determine linear displacements of a proprietary orientation sensor during cyclical movement. This makes experiments outside the constraints of the laboratory possible, for example to measure mechanical energy ...
Functional specialisation of pelvic limb anatomy in horses (Equus caballus).
Journal of anatomy    June 18, 2005   Volume 206, Issue 6 557-574 doi: 10.1111/j.1469-7580.2005.00420.x
Payne RC, Hutchinson JR, Robilliard JJ, Smith NC, Wilson AM.We provide quantitative anatomical data on the muscle-tendon units of the equine pelvic limb. Specifically, we recorded muscle mass, fascicle length, pennation angle, tendon mass and tendon rest length. Physiological cross sectional area was then determined and maximum isometric force estimated. There was proximal-to-distal reduction in muscle volume and fascicle length. Proximal limb tendons were few and, where present, were relatively short. By contrast, distal limb tendons were numerous and long in comparison to mean muscle fascicle length, increasing potential for elastic energy storage. W...
Third metacarpal bone laterality asymmetry and midshaft dimensions in Thoroughbred racehorses.
Australian veterinary journal    May 24, 2005   Volume 83, Issue 4 224-226 doi: 10.1111/j.1751-0813.2005.tb11657.x
Davies HM, Watson KM.The aims of this study were to test whether longer third metacarpal (MC3) bones had thicker dorsal cortices in a group of racehorses that were exercising at similar maximum speeds, and to establish if horses with larger differences in length between their right and left MC3 bones showed larger differences in the dorsal cortical thickness between the two limbs. Methods: An observational study. Methods: Forty Thoroughbred racehorses aged between 2 and 6 years and in training at racing speed at two racing stables were used. Two sets of radiographs of each left and right metacarpus of each horse w...
Up-regulation of site-specific remodeling without accumulation of microcracking and loss of osteocytes.
Bone    May 24, 2005   Volume 37, Issue 1 16-24 doi: 10.1016/j.bone.2004.12.016
Da Costa Gómez TM, Barrett JG, Sample SJ, Radtke CL, Kalscheur VL, Lu Y, Markel MD, Santschi EM, Scollay MC, Muir P.Functional adaptation of bone normally protects the skeleton from fracture during daily activity. Accumulation of microcracking and loss of osteocytes have been implicated in the regulation and initiation of targeted (reparative) remodeling of bone and, in certain situations, the development of fatigue or stress fracture. We performed a histologic study of the dorsal cortex of the mid-diaphysis of the third metacarpal (Mc-III) bone of Thoroughbred racehorses after bones were bulk-stained in basic fuchsin and transverse calcified sections were prepared. The Thoroughbred racehorse is an extreme ...
Relationships between hoof-acceleration patterns of galloping horses and dynamic properties of the track.
American journal of veterinary research    May 20, 2005   Volume 66, Issue 4 589-595 doi: 10.2460/ajvr.2005.66.589
Ratzlaff MH, Wilson PD, Hutton DV, Slinker BK.To define relationships between hoof-acceleration patterns of galloping horses and dynamic properties of the track. Methods: 8 Thoroughbred horses without lameness. Methods: Acceleration-time curves were recorded by use of accelerometers attached to each hoof as each horse galloped over the track straightaway. Four sessions were conducted for each horse, with the track surface modified by sequentially adding water before each session. These acceleration-time curves were analyzed to determine peak accelerations during the support phase of the stride. Track dynamic properties (hardness, rebound,...
Evaluation of displacement of the digital cushion in response to vertical loading in equine forelimbs.
American journal of veterinary research    May 20, 2005   Volume 66, Issue 4 623-629 doi: 10.2460/ajvr.2005.66.623
Taylor DD, Hood DM, Potter GD, Hogan HA, Honnas CM.To evaluate patterns of digital cushion (DC) displacement that occur in response to vertical loading of the distal portion of the forelimb in horses. Sample Population-Forelimbs from 10 horses with normal feet. Methods: Patterns of DC displacement induced by in vitro vertical limb loading were determined. Load-induced displacement of the DC was defined as the magnitude and direction of displacement of 6 radio-dense, percutaneously implanted markers in specific regions of the DC. The effects of solar support and nonsupport on displacement of the DC were compared. Results: Regional displacement ...
Computer-assisted kinematic evaluation of induced compensatory movements resembling lameness in horses trotting on a treadmill.
American journal of veterinary research    May 20, 2005   Volume 66, Issue 4 646-655 doi: 10.2460/ajvr.2005.66.646
Kelmer G, Keegan KG, Kramer J, Wilson DA, Pai FP, Singh P.To characterize compensatory movements of the head and pelvis that resemble lameness in horses. Methods: 17 adult horses. Methods: Kinematic evaluations were performed while horses trotted on a treadmill before and after shoe-induced lameness. Lameness was quantified and the affected limb determined by algorithms that measured asymmetry in vertical movement of the head and pelvis. Induced primary lameness and compensatory movements resembling lameness were assessed by the Friedman test. Association between induced lameness and compensatory movements was examined by regression analysis. Results...
Effect of exercise on age-related changes in collagen fibril diameter distributions in the common digital extensor tendons of young horses.
American journal of veterinary research    May 20, 2005   Volume 66, Issue 4 564-568 doi: 10.2460/ajvr.2005.66.564
Edwards LJ, Goodship AE, Birch HL, Patterson-Kane JC.To determine whether specific treadmill exercise regimens would accelerate age-related changes in collagen fibril diameter distributions in the common digital extensor tendon (CDET) of the forelimbs of young Thoroughbreds. Methods: 24 female Thoroughbreds. Methods: Horses were trained for 18 weeks (6 horses; short term) or 18 months (5 horses; long term) on a high-speed treadmill; 2 age-matched control groups (6 horses/group) performed walking exercise only. Horses were (mean +/- SD) 24 +/- 1 months and 39 +/- 1 months old at termination of the short-term and long-term regimens, respectively. ...
The effects of hormone replacement on the biomechanical properties of the uterosacral and round ligaments in the monkey model.
American journal of obstetrics and gynecology    May 20, 2005   Volume 192, Issue 5 1741-1751 doi: 10.1016/j.ajog.2004.10.639
Vardy MD, Gardner TR, Cosman F, Scotti RJ, Mikhail MS, Preiss-Bloom AO, Williams JK, Cline JM, Lindsay R.The purpose of this study was to determine effects of ovariectomy (OVX) and conjugated equine estrogens plus medroxyprogesterone acetate (CEE/MPA), or ethinyl estradiol plus norethindrone acetate (EE/NA) on biomechanics of uterosacral (USL) and round (RL) ligaments in postmenopausal (PMP) monkeys. Methods: This was a randomized, triple blind, placebo-controlled study. OVX monkeys received 12 months no treatment (Pbo) (n = 19), CEE/MPA (n = 19), or EE/NA (n = 21). USL and RL step strains and stress-relaxation data were curve-fitted, giving strain-dependent tensile modulus (TM) from 0% to 30%. R...
Electromyographic activity of the stylopharyngeus muscle in exercising horses.
Equine veterinary journal    May 17, 2005   Volume 37, Issue 3 232-235 doi: 10.2746/0425164054530759
Tessier C, Holcombe SJ, Stick JA, Derksen FJ, Boruta D.There is a need to understand the process which leads to failure of recruitment of the stylopharyngeus muscle in clinical cases of nasopharygeal collapse. We therefore studied the timing and intensity of stylopharyngeus muscle activity during exercise in horses. Objective: To measure the electromyographic (EMG) activity of the stylopharyngeus muscle in exercising horses and correlate it with the breathing pattern. Methods: Five horses were equipped with a bipolar fine wire electrode placed on the stylopharyngeus muscle and a pharyngeal catheter. The horses exercised on a treadmill at speeds co...
Arthrodesis of the equine proximal interphalangeal joint: a mechanical comparison of 2 parallel 5.5 mm cortical screws and 3 parallel 5.5 mm cortical screws.
Veterinary surgery : VS    April 30, 2005   Volume 34, Issue 2 142-147 doi: 10.1111/j.1532-950X.2005.00022.x
Read EK, Chandler D, Wilson DG.To compare the biomechanical characteristics and mode of failure of 2 techniques using parallel 5.5 mm screws for pastern joint arthrodesis in horses. Methods: Randomized block design, for horse (1-5), method of fixation (two 5.5 mm screws versus three 5.5 mm screws), side (right, left), and end (front, hind). Constructs were tested to failure in 3-point bending. Methods: Twenty limbs (5 cadavers). Methods: A combined aiming device was used to facilitate screw placement. Two parallel 5.5 mm screws were inserted in lag fashion in 1 limb of a pair, and three 5.5 mm screws were inserted in the co...
1 52 53 54 55 56 85