Analyze Diet

Topic:Biomechanics

Biomechanics in horses refers to the study of the mechanical principles that govern movement and physical function in equine species. This field encompasses the analysis of gait, locomotion, and the forces exerted by and upon the horse's musculoskeletal system. Biomechanical studies often involve the use of motion capture technology, force plates, and computer modeling to assess how horses move and how various factors, such as conformation, training, and health status, influence their performance and soundness. Research in equine biomechanics contributes to understanding injury prevention, rehabilitation, and performance optimization. This page compiles peer-reviewed research studies and scholarly articles that explore the mechanics of movement, the impact of external and internal forces, and the applications of biomechanical analysis in equine care and management.
Spatial distribution of osteocyte lacunae in equine radii and third metacarpals: considerations for cellular communication, microdamage detection and metabolism.
Cells, tissues, organs    December 7, 2005   Volume 180, Issue 4 215-236 doi: 10.1159/000088938
Skedros JG, Grunander TR, Hamrick MW.Osteocytes, which are embedded in bone matrix, are the most abundant cells in bone. Despite the ideal location of osteocytes to sense the local environment and influence bone remodeling, their functions, and the relative importance of these functions, remain controversial. In this study, we tested several hypotheses that address the possibilities that population densities of osteocyte lacunae (Ot.Lc.N/B.Ar) correlate with strain-, remodeling- or metabolism-related aspects of the local biomechanical environments of mid-third diaphyseal equine radii and third metacarpals from skeletally mature a...
Changes in location of centre of pressure and hoof-unrollment pattern in relation to an 8-week shoeing interval in the horse.
Equine veterinary journal    November 22, 2005   Volume 37, Issue 6 536-540 doi: 10.2746/042516405775314925
Van Heel MC, Moleman M, Barneveld A, Van Weeren PR, Back W.In order to optimise shoeing and shoeing conditions, it is essential to know how the horse adapts to a common shoeing interval. Objective: To measure changes in location of the centre of pressure (CoP) and hoof-unrollment pattern during a shoeing interval and to assess whether these changes in CoP result directly from changes in hoof conformation or are also influenced by compensatory mechanisms. Methods: Eighteen horses were trotted over a pressure-force measurement system shortly after shoeing and 8 weeks later. The position of the CoP was measured and also predicted using calculations based...
Coordination dynamics of the horse-rider system.
Journal of motor behavior    November 11, 2005   Volume 37, Issue 6 418-424 doi: 10.3200/JMBR.37.6.418-424
Lagarde J, Kelso JA, Peham C, Licka T.The authors studied the interaction between rider and horse by measuring their ensemble motions in a trot sequence, comparing 1 expert and 1 novice rider. Whereas the novice's movements displayed transient departures from phase synchrony, the expert's motions were continuously phase-matched with those of the horse. The tight ensemble synchrony between the expert and the horse was accompanied by an increase in the temporal regularity of the oscillations of the trunk of the horse. Observed differences between expert and novice riders indicated that phase synchronization is by no means perfect bu...
Association between subjective lameness grade and kinetic gait parameters in horses with experimentally induced forelimb lameness.
American journal of veterinary research    November 9, 2005   Volume 66, Issue 10 1805-1815 doi: 10.2460/ajvr.2005.66.1805
Ishihara A, Bertone AL, Rajala-Schultz PJ.To evaluate the association between subjective lameness grades and kinetic gait parameters and assess the variability in kinetic parameters in horses with experimentally induced forelimb lameness. Methods: 32 horses. Methods: Forelimb lameness was induced in each horse via injection of lipopolysaccharide into 1 metacarpophalangeal joint (40 experimental trials). Subjective lameness grading and 13 kinetic gait parameters (force plate analysis) were assessed before (baseline) and at 12, 18, and 24 hours after lipopolysaccharide injection. While horses were trotting, kinetic gait analysis was per...
Effects of radial shock waves on membrane permeability and viability of chondrocytes and structure of articular cartilage in equine cartilage explants.
American journal of veterinary research    November 9, 2005   Volume 66, Issue 10 1757-1763 doi: 10.2460/ajvr.2005.66.1757
Byron CR, Benson BM, Stewart AA, Stewart MC.To investigate in vitro effects of radial shock waves on membrane permeability, viability, and structure of chondrocytes and articular cartilage. Methods: Cartilage explants obtained from the third metacarpal and metatarsal bones of 6 horses. Methods: Equine cartilage was subjected to radial shock waves and then maintained as explants in culture for 48 hours. Treatment groups consisted of a negative control group; application of 500, 2,000, and 4,000 impulses by use of a convex handpiece (group A); and application of 500, 2,000, and 4,000 impulses by use of a concave handpiece (group B). Effec...
Evaluation of subchondral bone mineral density associated with articular cartilage structure and integrity in healthy equine joints with different functional demands.
American journal of veterinary research    November 9, 2005   Volume 66, Issue 10 1823-1829 doi: 10.2460/ajvr.2005.66.1823
Lewis CW, Williamson AK, Chen AC, Bae WC, Temple MM, Wong WV, Nugent GE, James SP, Wheeler DL, Sah RL, Kawcak CE.To determine and correlate subchondral bone mineral density and overlying cartilage structure and tensile integrity in mature healthy equine stifle (low magnitude loading) and metacarpophalangeal (high magnitude loading) joints. Methods: 8 healthy horses, 2 to 3 years of age. Methods: Osteochondral samples were acquired from the medial femoral condyle (FC) and medial trochlear ridge (TR) of the stifle joint and from the dorsal (MC3D) and palmar (MC3P) aspects of the distal medial third metacarpal condyles of the metacarpophalangeal joint. Articular cartilage surface fibrillation (evaluated via...
A novel method to estimate the stiffness of the equine back.
Journal of biomechanics    November 8, 2005   Volume 39, Issue 15 2845-2849 doi: 10.1016/j.jbiomech.2005.09.019
Peham C, Schobesberger H.Diagnosis of back problems in equine orthopedics can be a difficult task. The aim of our study was to develop a new method for estimating the stiffness of the equine back in vivo. We measured the activity of the long back muscle at two locations on both sides at thoracic vertebrae T12 and T16 of 15 horses flexing and extending their back at stance using telemetric surface electromyography, while simultaneously recording the motion of the back with a video camera system. Out of these paired data sets we computed a transfer function in the frequency domain and evaluated its capability of capturi...
Role of endochondral ossification of articular cartilage and functional adaptation of the subchondral plate in the development of fatigue microcracking of joints.
Bone    November 4, 2005   Volume 38, Issue 3 342-349 doi: 10.1016/j.bone.2005.08.020
Muir P, McCarthy J, Radtke CL, Markel MD, Santschi EM, Scollay MC, Kalscheur VL.The mechanisms that regulate functional adaptation of the articular ends of long bones are poorly understood. However, endochondral ossification of articular cartilage and modeling/remodeling of the subchondral plate and epiphyseal trabeculae are important components of the adaptive response. We performed a histologic study of the distal end of the third metacarpal/metatarsal bone of Thoroughbreds after bones were bulk-stained in basic fuchsin and calcified sections were prepared. The Thoroughbred racehorse is a model of an extreme athlete which experiences particularly high cyclic strains in ...
Determining effective centroid position in biomechanical testing: a technique for simplifying whole bone analysis.
Journal of biomechanical engineering    October 27, 2005   Volume 127, Issue 5 736-741 doi: 10.1115/1.1993663
Whan G, Runciman RJ, Hurtig M.Whole bone in vitro biomechanical compressive testing can be complicated by three factors: sample asymmetry, heterogeneous material properties, and unknown effective centroid location. Methods: The technique presented here facilitates the calculation of effective centroid position, modulus of elasticity and equivalent uniform strain magnitude for a cross section of bone from a simple whole bone compressive test. Simplification of section response to load is achieved through a combination of linear beam and simple planer geometry theory. The technique requires three longitudinal strain gauges b...
Functional consequences of cartilage degeneration in the equine metacarpophalangeal joint: quantitative assessment of cartilage stiffness.
Equine veterinary journal    September 17, 2005   Volume 37, Issue 5 462-467 doi: 10.2746/042516405774480012
Brommer H, Laasanen MS, Brama PA, van Weeren PR, Helminen HJ, Jurvelin JS.No quantitative data currently exist on the relationship of the occurrence of cartilage degeneration and changes in site-specific biomechanical properties in the metacarpophalangeal (MCP) joint in the horse. Objective: To gain insight into the biomechanical consequences of cartilage deterioration at 2 differently loaded sites on the proximal articular surface of the proximal phalanx (P1). Objective: Static and dynamic stiffness of articular cartilage decreases significantly in degenerated cartilage. Methods: Cartilage degeneration index (CDI) values were measured at the lateral dorsal margin (...
Membrane-coating granules and the intercellular cementing substance (membrane-coating material) in the epidermis in different regions of the equine hoof.
Anatomia, histologia, embryologia    September 15, 2005   Volume 34, Issue 5 298-306 doi: 10.1111/j.1439-0264.2005.00616.x
Anthauer K, Mülling C, Budras KD.This study aimed to carry out a comprehensive morphological examination of the structure and ultrastructure of the membrane-coating granules (MCG) and membrane-coating material (MCM) common to all hoof segments as well as segment-specific features in the MCG and MCM regarding their synthesis, structure and biochemical composition. Tissue samples from the hooves of the left front and right hind limb of 20 adult riding horses were used. Samples were preserved and embedded for histological routine methods as well as for histochemical techniques and tracer techniques for light and electron microsc...
Linear kinematics at take-off in horses jumping the wall in an international Puissance competition.
Sports biomechanics    September 6, 2005   Volume 4, Issue 2 149-162 doi: 10.1080/14763140508522860
Powers P.Sagittal plane SVHS video recordings (50 Hz) were made of horses jumping the wall at an international Puissance competition. Video sequences were manually digitized and six kinematic variables at take-off were analyzed. Nine horses started the competition with the fence height at 1.80 m, and two horses attempted the fence in the fifth and final round with the fence height at 2.27 m. For successful performances, fence height was correlated with the following take-off variables: vertical velocity of the centre of mass (r = 0.45, p = 0.03); height of centre of mass (r = 0.44, p = 0.04); distance ...
Can jumping capacity of adult show jumping horses be predicted on the basis of submaximal free jumps at foal age? A longitudinal study.
Veterinary journal (London, England : 1997)    September 1, 2005   Volume 170, Issue 2 212-221 doi: 10.1016/j.tvjl.2004.06.009
Bobbert MF, Santamaría S, van Weeren PR, Back W, Barneveld A.The purpose of this study was to quantify performance characteristics of good jumping horses, and to determine whether these were already detectable at foal age. Kinematic data were collected of horses performing free jumps over a 0.60 m high fence at six months of age and of these same horses jumping with a rider over a 1.15 m high fence at five years of age. At five years of age the horses were divided into three groups on the basis of a puissance competition: a group of seven best jumpers that made no errors and in the end cleared a 1.50 m high fence, a group of nine worst jumpers that were...
Mechanical and functional properties of the equine superficial digital flexor tendon.
Veterinary journal (London, England : 1997)    September 1, 2005   Volume 170, Issue 2 184-192 doi: 10.1016/j.tvjl.2004.03.021
Dowling BA, Dart AJ.The in vitro and in vivo mechanical properties of the superficial digital flexor tendon have been described. To date the focus has been on single load to failure testing, however refined in vivo methods may prove useful to evaluate the effects of treatment and exercise on tendons. During maximal exercise, the adult superficial digital flexor tendon operates close to its functional limits with a narrow biomechanical safety margin. This combined with exercise and age associated microdamage, and a limited adaptive ability may increase the risk of fatigue failure. Studies evaluating treatment regi...
Respiratory mechanics in Standardbred horses with sub-clinical inflammatory airway disease and poor athletic performance.
Veterinary journal (London, England : 1997)    August 29, 2005   Volume 173, Issue 1 144-150 doi: 10.1016/j.tvjl.2005.07.020
Pirrone F, Albertini M, Clement MG, Lafortuna CL.The aim of this study was to investigate and quantify respiratory mechanical dysfunctions in Standardbred horses with both poor performance and bronchoalveolar lavage fluid cytology characteristic of inflammatory airway disease (IAD). A control group of healthy Standardbred horses was compared. Respiratory mechanics and breathing pattern were examined at rest and during hyperventilation induced using a rebreathing method. At rest, respiratory mechanics and breathing pattern were superimposable in both groups. In IAD horses, rebreathing increased ventilation, with larger tidal volumes and lower...
Effects of recombinant equine growth hormone on in vitro biomechanical properties of the superficial digital flexor tendon of Standardbred yearlings in training.
Veterinary surgery : VS    August 24, 2005   Volume 34, Issue 3 253-259 doi: 10.1111/j.1532-950X.2005.00038.x
Gerard MP, Hodgson DR, Rose RJ, Walsh WR.To determine whether recombinant equine growth hormone (rEGH) would alter the in vitro biomechanical properties of the forelimb superficial digital flexor tendon (SDFT) in exercising young Standardbred horses. Methods: Randomized complete block design. Methods: Twelve Standardbred yearlings. Methods: Horses were trained for 12 weeks on a high-speed treadmill (10% positive incline). rEGH was administered intramuscularly (IM) daily (10 microg/kg during week 4; 20 microg/kg for weeks 5-9) to 6 horses (treated group), whereas 6 horses (control group) were administered an equivalent daily volume of...
Assessment of stiffness and strength of 4 different implants available for equine fracture treatment: a study on a 20 degrees oblique long-bone fracture model using a bone substitute.
Veterinary surgery : VS    August 24, 2005   Volume 34, Issue 3 231-238 doi: 10.1111/j.1532.950X.2005.00035.x
Florin M, Arzdorf M, Linke B, Auer JA.To compare the mechanical properties of 4 stabilization methods for equine long-bone fractures: dynamic compression plate (DCP), limited contact-DCPlate (LC-DCP), locking compression plate (LCP), and the clamp-rod internal fixator (CRIF--formerly VetFix). Methods: In vitro mechanical study. Methods: Bone substitute material (24 tubes) was cut at 20 degrees to the long axis of the tube to simulate an oblique mid-shaft fracture. Methods: Tubes were divided into 4 groups (n=6) and double plated in an orthogonal configuration, with 1 screw of 1 implant being inserted in lag fashion through the "fr...
Influence of age, site, and degenerative state on the speed of sound in equine articular cartilage.
American journal of veterinary research    August 23, 2005   Volume 66, Issue 7 1175-1180 doi: 10.2460/ajvr.2005.66.1175
Brommer H, Laasanen MS, Brama PA, van Weeren PR, Barneveld A, Helminen HJ, Jurvelin JS.To determine the speed of sound (SOS) in equine articular cartilage and investigate the influence of age, site in the joint, and cartilage degeneration on the SOS. Methods: Cartilage samples from 38 metacarpophalangeal joints of 38 horses (age range, 5 months to 22 years). Methods: Osteochondral plugs were collected from 2 articular sites of the proximal phalanx after the degenerative state was characterized by use of the cartilage degeneration index (CDI) technique. The SOS was calculated (ratio of needle-probe cartilage thickness to time of flight of the ultrasound pulse), and relationships ...
Biochemical analysis of the articular cartilage and subchondral and trabecular bone of the metacarpophalangeal joint of horses with early osteoarthritis.
American journal of veterinary research    August 23, 2005   Volume 66, Issue 7 1238-1246 doi: 10.2460/ajvr.2005.66.1238
van der Harst MR, DeGroot J, Kiers GH, Brama PA, van de Lest CH, van Weeren PR.To assess whether site-related changes in biochemical composition are present in the cartilage and subchondral and trabecular bone of the metacarpophalangeal joint of horses with early osteoarthritis. Methods: Right metacarpophalangeal joints from 59 mature warmblood horses. Methods: Biochemical data (cross-link, amino acid, DNA, and ash contents; denatured collagen and glycosaminoglycan [GAG] concentrations; bone mineral density; and mineral composition) were obtained from 2 differently loaded sites of phalanx I cartilage and subchondral and trabecular bone samples; data were compared with pr...
Extracellular matrix composition of the equine superficial digital flexor tendon: relationship with age and anatomical site.
Journal of veterinary medicine. A, Physiology, pathology, clinical medicine    August 20, 2005   Volume 52, Issue 7 333-338 doi: 10.1111/j.1439-0442.2005.00742.x
Lin YL, Brama PA, Kiers GH, van Weeren PR, DeGroot J.The objectives of the present study were to test the hypotheses that: (1) the composition of the extracellular matrix of the equine superficial digital flexor tendon (SDFT) shows great functional similarities with articular cartilage, i.e. that significant differences exist in biochemical composition of differently loaded areas (which in the case of tendons may be more apparent as tendon shows more obvious differences than cartilage); and (2) that, as in articular cartilage, no substantial alterations in biochemical composition take place during ageing once adulthood has been attained. Tendon ...
Biochemical and biomechanical properties of lesion and adjacent articular cartilage after chondral defect repair in an equine model.
The American journal of sports medicine    August 10, 2005   Volume 33, Issue 11 1647-1653 doi: 10.1177/0363546505275487
Strauss EJ, Goodrich LR, Chen CT, Hidaka C, Nixon AJ.Chondral defects may lead to degradative changes in the surrounding cartilage, predisposing patients to developing osteoarthritis. Objective: To quantify changes in the biomechanical and biochemical properties of the articular cartilage adjacent to chondral defects after experimental defect repair. Methods: Controlled laboratory study. Methods: Specimens were harvested from tissue within (lesion), immediately adjacent to, and at a distance from (remote area) a full-thickness cartilage defect 8 months after cartilage repair with genetically modified chondrocytes expressing insulin-like growth f...
A non-invasive method of tendon force measurement.
Journal of biomechanics    August 9, 2005   Volume 38, Issue 10 2124-2129 doi: 10.1016/j.jbiomech.2004.09.012
Pourcelot P, Defontaine M, Ravary B, Lemâtre M, Crevier-Denoix N.The ability to measure the forces exerted in vivo on tendons and, consequently, the forces produced by muscles on tendons, offers a unique opportunity to investigate questions in disciplines as varied as physiology, biomechanics, orthopaedics and neuroscience. Until now, tendon loads could be assessed directly only by means of invasive sensors implanted within or attached to these collagenous structures. This study shows that the forces acting on tendons can be measured, in a non-invasive way, from the analysis of the propagation of an acoustic wave. Using the equine superficial digital flexor...
Design and demonstration of a dynamometric horseshoe for measuring ground reaction loads of horses during racing conditions.
Journal of biomechanics    August 9, 2005   Volume 38, Issue 10 2102-2112 doi: 10.1016/j.jbiomech.2004.08.024
Roland ES, Hull ML, Stover SM.Because musculoskeletal injuries to racehorses are common, instrumentation for the study of factors (e.g. track surface), which affect the ground reaction loads in horses during racing conditions, would be useful. The objectives of the work reported by this paper were to (1) design and construct a novel dynamometric horseshoe that is capable of measuring the complete ground reaction loading during racing conditions, (2) characterize static and dynamic measurement errors, and (3) demonstrate the usefulness of the instrument by collecting example data during the walk, trot, canter, and gallop fo...
Linear and temporal stride characteristics of 3-day event horses at a CCI*** 3-day event horse inspection.
New Zealand veterinary journal    July 21, 2005   Volume 47, Issue 6 193-197 doi: 10.1080/00480169.1999.36142
Rogers CW, Davies AS, Pfeiffer DU, Davie PS.To quantify the linear and temporal characteristics of the trot of 3-day event horses during the preliminary horse inspection of an advanced grade CCI*** 3-day event. Methods: A cross sectional study was made of the kinematics of 24 3-day-event horses during the first horse inspection at a CCI*** level S-day event. Video footage was digitised and linear and temporal measurements were made. Results: The horses trotted for an average of 10.44+/-1.55 strides. Spatial measurements were made on an average of 5.66+/-0.92 consecutive strides when the horses were within the calibration zone. The horse...
Saddle pressure measuring: validity, reliability and power to discriminate between different saddle-fits.
Veterinary journal (London, England : 1997)    July 12, 2005   Volume 172, Issue 2 265-273 doi: 10.1016/j.tvjl.2005.05.009
de Cocq P, van Weeren PR, Back W.Saddle-fit is recognised as an important factor in the pathogenesis of back problems in horses and is empirically being evaluated by pressure measurements in clinical practice, although not much is known about the validity, reliability and usability of these devices in the equine field. This study was conducted to assess critically a pressure measurement system marketed for evaluating saddle fit. Validity was tested by calculating the correlation coefficient between total measured pressure and the weight of 28 different riders. Reliability and discriminative power with respect to different sad...
Osteon interfacial strength and histomorphometry of equine cortical bone.
Journal of biomechanics    July 12, 2005   Volume 39, Issue 9 1629-1640 doi: 10.1016/j.jbiomech.2005.05.006
Bigley RF, Griffin LV, Christensen L, Vandenbosch R.The interfacial strength of secondary osteons from the diaphysis of the Thoroughbred equine third metacarpal was evaluated using the fiber pushout test. The pushout was performed on 300-500 microm sections of 4x4x15 mm bone blocks machined from four anatomic regions of the cortex. Pushout strength was evaluated from proximal to distal location within the diaphysis on four osteon types classified under polarized light on adjacent histologic sections from each block. The shear strength of the interfaces were estimated from shear lag theory. Differences were found in the interfacial strength of o...
Femoral asymmetry in the Thoroughbred racehorse.
Australian veterinary journal    July 1, 2005   Volume 83, Issue 6 367-370 doi: 10.1111/j.1751-0813.2005.tb15636.x
Pearce GP, May-Davis S, Greaves D.To investigate the occurrence of geometrical asymmetries in the macro-architecture of left and right femurs from Thoroughbred racehorses previously used in competitive training and racing in New South Wales, Australia. Methods: Detailed postmortem measurements were made of 37 characteristics of left and right femurs from eleven Thoroughbred racehorses euthanased for reasons unrelated to the study. Measurements focused on articulating surfaces and sites of attachment of muscles and ligaments known to be associated with hindlimb locomotion. Results: Five measurements were significantly larger in...
An in vitro study on spontaneous myometrial contractility in the mare during estrus and diestrus.
Theriogenology    July 1, 2005   Volume 65, Issue 3 517-527 doi: 10.1016/j.theriogenology.2005.05.048
Hirsbrunner G, Reist M, Couto SS, Steiner A, Snyder J, Vanleeuwen E, Liu I.Uterine smooth muscle specimens were collected from euthanatized mares in estrus and diestrus. Longitudinal and circular specimens were mounted in organ baths and the signals transcribed to a Grass polygraph. After equilibration time and 2 g preload, their physiologic isometric contractility was recorded for a continuous 2.0 h. Area under the curve, frequency and time occupied by contractions were studied. Differences between cycle phases, between muscle layers, and over the recorded time periods were statistically evaluated using linear mixed-effect models. In the mare, physiologic contractil...
Comparison of girth materials, girth tensions and their effects on performance in racehorses.
Australian veterinary journal    June 24, 2005   Volume 83, Issue 1-2 68-74 doi: 10.1111/j.1751-0813.2005.tb12200.x
Bowers J, Slocombe RF.To compare the effect of girth materials and commonly used girth tensions on athletic performance of race-horses and to test the length tension properties of commercially available girths. Methods: Seven horses were exercised at speeds to produce 95% of maximal heart rates on 15 occasions using a randomised block design, and girthed with 5 different girths at 3 nominal tensions of 6, 12 or 18 kg. The girths used were a standard elastic race girth, an 'American' elastic race girth, an elastic race girth twice the normal width, a standard canvas race girth and a canvas race girth at twice the no...
Musculoskeletal modeling and dynamic simulation of the thoroughbred equine forelimb during stance phase of the gallop.
Journal of biomechanical engineering    June 24, 2005   Volume 127, Issue 2 318-328 doi: 10.1115/1.1865196
Swanstrom MD, Zarucco L, Hubbard M, Stover SM, Hawkins DA.Because thoroughbred racehorses have a high incidence of forelimb musculoskeletal injuries, a model was desired to screen potential risk factors for injuries. This paper describes the development of a musculoskeletal model of the thoroughbred forelimb and a dynamic simulation of the motion of the distal segments during the stance phase of high-speed (18 m/s) gallop. The musculoskeletal model is comprised of segment, joint, muscle-tendon, and ligament information. The dynamic simulation incorporates a proximal forward-driving force, a distal ground reaction force model, muscle activations, and ...
1 52 53 54 55 56 86