Analyze Diet

Topic:Biomechanics

Biomechanics in horses refers to the study of the mechanical principles that govern movement and physical function in equine species. This field encompasses the analysis of gait, locomotion, and the forces exerted by and upon the horse's musculoskeletal system. Biomechanical studies often involve the use of motion capture technology, force plates, and computer modeling to assess how horses move and how various factors, such as conformation, training, and health status, influence their performance and soundness. Research in equine biomechanics contributes to understanding injury prevention, rehabilitation, and performance optimization. This page compiles peer-reviewed research studies and scholarly articles that explore the mechanics of movement, the impact of external and internal forces, and the applications of biomechanical analysis in equine care and management.
Effect of rider and riding style on deformation of the front hoof wall in warmblood horses.
Equine veterinary journal. Supplement    February 5, 1999   Issue 26 81-85 doi: 10.1111/j.2042-3306.1998.tb05125.x
Summerley HL, Thomason JJ, Bignell WW.A rider modifies the weight distribution and dynamic balance of the horse. But what effect does a rider have on the mechanical behaviour of the hoof during each stance phase? Does riding style have any effect on this behaviour? We attempted to answer these questions using strains recorded from 5 rosette strain gauges glued to the surface of the front hooves of 4 Warmblood horses. Comparisons were made between strains with and without a rider, and when the rider was sitting, rising at a trot, or in a forward seated position. The change in strains from trot to lead or nonlead at a canter, and th...
Variation in surface strain on the equine hoof wall at the midstep with shoeing, gait, substrate, direction of travel, and hoof shape.
Equine veterinary journal. Supplement    February 5, 1999   Issue 26 86-95 doi: 10.1111/j.2042-3306.1998.tb05126.x
Thomason JJ.Objectives were to examine the deformation of the healthy equine front hoof during locomotion, by recording strains on its outer surface, and to test whether its mechanical behaviour is significantly altered under different locomotory conditions and variation in hoof shape. Strains were recorded in vivo from 5 rosette gauges around the circumference of the right forehooves of 12 horses. The magnitudes and orientations of principal strains at the midstep were compared statistically for different conditions of shoeing (shod vs. unshod), gait (walk vs. trot), substrate (treadmill vs. ground), and...
Finite element analysis of static loading in donkey hoof wall.
Equine veterinary journal. Supplement    February 5, 1999   Issue 26 103-110 doi: 10.1111/j.2042-3306.1998.tb05128.x
Newlyn HA, Collins SN, Cope BC, Hopegood L, Latham RJ, Reilly JD.A finite element model of donkey hoof wall was constructed from measurements taken directly from the hoof capsule of the left forefoot. The model was created with a 2 mm mesh and consisted of 11,608 nodes. A linear elastic analysis was conducted assuming isotropic material properties in response to a 375 newton (N) load, to simulate static loading. The load was applied to the wall via 400 laminae in order to simulate the way in which the pedal bone is suspended within the donkey hoof capsule. Displacement, stress concentration, principal strain, and force distribution across the hoof wall were...
In vitro attenuation of impact shock in equine digits.
Equine veterinary journal. Supplement    February 5, 1999   Issue 26 96-102 doi: 10.1111/j.2042-3306.1998.tb05127.x
Lanovaz JL, Clayton HM, Watson LG.This study was designed to test the impact characteristics of the equine digit in vitro with the objective of providing a better understanding of the role of the digital structures in the attenuation of impact shock. Uni-axial accelerometers were mounted on cadaver digits on the distolateral hoof wall, the proximolateral hoof wall, the dorsal surface of the second phalanx, and the mid-lateral first phalanx. The hoof-mounted accelerometers were aligned with the hoof tubules while the bone-mounted accelerometers were oriented along the longitudinal axis of the bone. Each digit was mounted in a t...
Exploring the possible functions of equine hoof wall tubules.
Equine veterinary journal. Supplement    February 5, 1999   Issue 26 10-14 doi: 10.1111/j.2042-3306.1998.tb05116.x
Kasapi MA, Gosline JM.Possible functions of equine hoof wall tubules were investigated in this study. Hydration tests were conducted on blocks of hoof wall tissue in order to test the hypothesis that hollow tubules facilitate the conduction of water vapour distally. Although water loss or gain was inhibited through the outer wall surface, the increase in surface area provided by medullary spaces was ineffective in facilitating hydration through the face with exposed tubule ends. Rather, hollow tubules appear to allow for a higher dehydration rate through their exposed ends. Analysis of medullary space indicates tha...
Effects of season and diet on tensile strength and mineral content of the equine hoof wall.
Equine veterinary journal. Supplement    February 5, 1999   Issue 26 46-50 doi: 10.1111/j.2042-3306.1998.tb05121.x
Ley WB, Scott Pleasant R, Dunnington EA.Studies evaluating nutritional and seasonal influences on hoof strength and composition in horses, as well as the scientific justification for feeding supplements to improve hoof quality, are lacking. The horseman and veterinarian need controlled studies in this area to make informed decisions. This project quantified, in 2 trials, relative elasticity, tensile strength, % moisture, and mineral composition of hooves of 48 mature Thoroughbred mares maintained on different nutritional/management regimens, sampled quarterly over 12 month periods. Tensile strength was positively associated with sul...
The development of microcracking and failure in bone depends on the loading mode to which it is adapted.
The Journal of experimental biology    February 4, 1999   Volume 202, Issue Pt 5 543-552 doi: 10.1242/jeb.202.5.543
Reilly GC, Currey JD.During locomotion, the anterior cortex of the equine radius is loaded predominantly in tension, the posterior predominantly in compression. The anterior cortex is relatively strong in tension, the posterior in compression. We investigated the pattern of failure of specimens from the two cortices using laser scanning confocal microscopy. All specimens were loaded in four-point bending to increasingly higher loads. We quantified the amount of diffuse microcracking on the tensile side of these specimens by observing the amount of light emitted under laser illumination. The amount of light emitted...
Micromechanics of the equine hoof wall: optimizing crack control and material stiffness through modulation of the properties of keratin.
The Journal of experimental biology    January 23, 1999   Volume 202, Issue Pt 4 377-391 doi: 10.1242/jeb.202.4.377
Kasapi MA, Gosline JM.Small-scale components of the equine hoof wall were tested to determine their mechanical roles in the morphological hierarchy. Macroscale tensile tests conducted on samples of the inner wall tubules and intertubular material showed a sixfold difference in mean initial stiffnesses (0.47 and 0.08 GPa, respectively), indicating that the inner wall tubules stiffen the wall along its longitudinal axis. The similarity in material properties of tubule and intertubular samples from the mid-wall suggests that tubules in this region offer only minor reinforcement along the longitudinal axis. Microscale ...
A comparison of porosity, fabric and fractal dimension as predictors of the Young’s modulus of equine cancellous bone.
Medical engineering & physics    January 15, 1999   Volume 20, Issue 8 588-593 doi: 10.1016/s1350-4533(98)00063-0
Haire TJ, Hodgskinson R, Ganney PS, Langton CM.The purpose of this study was to compare the structural parameters of fabric and fractal dimension as predictors of the Young's modulus of equine cancellous bone. Eight 15 mm cubes of cancellous bone were obtained from three equine third metacarpal bones. Young's modulus was determined for the three orthogonal directions. The fabric and fractal dimension were calculated for each of the six exposed faces of each cube. Fractal dimension plus porosity provided a higher explanatory power for Young's modulus (R2 = 78.7%. P < 0.0001) than fabric plus porosity (R2 = 69.2%, P < 0.0001). Fractal ...
Equine developmental osteochondral lesions: the role of biomechanics.
Veterinary journal (London, England : 1997)    January 12, 1999   Volume 156, Issue 3 167-168 doi: 10.1016/s1090-0233(98)80119-6
Whitton RC.No abstract available
Kinematics of the equine back: a method to study the thoracolumbar flexion-extension movements at the trot.
Veterinary research    December 16, 1998   Volume 29, Issue 6 519-525 
Pourcelot P, Audigié F, Degueurce C, Denoix JM, Geiger D.This study was conducted to evaluate a method for quantifying the flexion-extension movements of the back of horses trotting on a track in the conditions of the clinical lameness examination. Using a 3-D kinematic analysis system, the successive positions of four markers placed at regular intervals between the withers and the tuber sacrale were recorded. To isolate the flexion-extension movements of the back, the positions of these four markers were recomputed in a trunk-related co-ordinate system of the horse. Then, for each frame, the equation of the third-order polynomial that best fitted t...
Angular kinematic patterns of limbs in elite and riding horses at trot.
Equine veterinary journal    December 9, 1998   Volume 30, Issue 6 528-533 doi: 10.1111/j.2042-3306.1998.tb04529.x
Morales JL, Manchado M, Vivo J, Galisteo AM, Agüera E, Miró F.Normal speed videography was used to determine the angular parameters of 28 Spanish Thoroughbreds at trot. Horses were divided into 3 groups: Group UT, comprising 9 animals (provided by the VII National Stud, Cordoba, Spain) which had undergone no specific training programme and which were hand led at the trot; Group T, formed by 19 horses considered to be highly bred and trained, and which were also hand led; and Group RT, comprising the same horses as the latter group but this time trotted by a rider. Each animal was filmed 6 times from the right-hand side, using a Hi8 (25 Hz) video camera. ...
The effect of foot imbalance on point of force application in the horse.
Equine veterinary journal    December 9, 1998   Volume 30, Issue 6 540-545 doi: 10.1111/j.2042-3306.1998.tb04531.x
Wilson AM, Seelig TJ, Shield RA, Silverman BW.Foot imbalance is believed to be a common cause of musculoskeletal injury in the horse; its biomechanical effects are, however, poorly understood. Wedges (angle 3.7 and 5 degrees) were attached to modified shoes to elevate one aspect of both front feet of Thoroughbred-type horses. The point of force application during weightbearing was determined at trot using a forceplate system. A total of 8 horses were studied with a minimum of 4 providing data for each wedge condition. The results demonstrated that application of a standard steel horse shoe to a balanced foot has minimal effect on the poin...
A comparison of the Synthes 4.5-mm cannulated screw and the Synthes 4.5-mm standard cortex screw systems in equine bone.
Veterinary surgery : VS    December 9, 1998   Volume 27, Issue 6 540-546 doi: 10.1111/j.1532-950x.1998.tb00529.x
Colgan SA, Hecker AT, Kirker-Head CA, Hayes WC.To determine risk of failure of the Synthes 4.5-mm cannulated screw system instrumentation in equine bone and to compare its application with the Synthes 4.5-mm standard cortex screw system. Methods: The maximum insertion torque of the cannulated and standard cortex screw systems were compared with the ultimate torsional strengths of the equipment. Pullout strength and ultimate tensile load of cannulated and standard cortex screws were also determined. Methods: Paired equine cadaver third metacarpal and third carpal bones. Methods: Maximum insertion torque and ultimate torsional strengths were...
Intra-articular pressure, elastance and range of motion in healthy and injured racehorse metacarpophalangeal joints.
Equine veterinary journal    December 9, 1998   Volume 30, Issue 6 520-527 doi: 10.1111/j.2042-3306.1998.tb04528.x
Strand E, Martin GS, Crawford MP, Kamerling SG, Burba DJ.The objective of this study was to determine if intraarticular pressure, elastance of the soft tissue forming the dorsal pouch, and range of motion in flexion measurements are significantly different in Thoroughbred metacarpophalangeal joints with clinical evidence of idiopathic synovitis, primary synovitis, synovitis/capsulitis, or osteoarthritis relative to clinically normal joints. Forty-two metacarpophalangeal joints, in 25 active or retired Thoroughbred racehorses, were categorised by palpation and visual inspection of the palmar pouch into one of 4 increasing grades of distention. Intra-...
The influence of speed and height at the withers on the kinematics of sound horses at the hand-led trot.
Veterinary research communications    November 12, 1998   Volume 22, Issue 6 415-423 doi: 10.1023/a:1006105614177
Galisteo AM, Cano MR, Morales JL, Vivo J, Miró F.The influence of speed and height at the withers on some biokinematic stride parameters (linear, temporal and angular) was measured in 15 Spanish Thoroughbreds (Andalusian Purebred) trotted hand-led along a track; analysis was made of the correlation between speed and height at the withers and of some biokinematic parameters of equine locomotion. Both height at the withers and speed were positively and significantly correlated to the linear parameters examined. Temporal parameters did not reveal a significant correlation with the height at the withers. The correlations with the angular paramet...
In-shoe foot force sensor to assess hoof balance determined by radiographic method in ponies trotting on a treadmill.
The veterinary quarterly    November 12, 1998   Volume 20, Issue 4 131-135 doi: 10.1080/01652176.1998.9694857
Caudron I, Grulke S, Farnir F, Vanschepdael P, Serteyn D.Adaptation of an in-foot shoe force sensor and the gait analysis system 'Fscan' makes it possible to monitor the distribution of the vertical forces under the equine foot in motion. The aim of this study is to investigate the effects of two different trimmings on forces under the foot during the trot. The first one increased the height of the lateral hoof wall and the second one restored the mediolateral balance of the foot. These two trimmings were examined by using a radiographical method that quantifies the interphalangeal articular asymmetries due to asymmetrical bearing. The location of t...
Speed dependency of motion pattern consistency.
Journal of biomechanics    November 5, 1998   Volume 31, Issue 9 769-772 doi: 10.1016/s0021-9290(98)00040-2
Peham C, Licka T, Mayr A, Scheidl M, Girtler D.Treadmills are widely used in equine motion analysis. For the evaluation of the trot of a horse, a trotting speed with low variation between motion cycles is necessary to make the measurements reproducible. The aim of this study is to show how an individual 'optimum' trotting speed for lameness quantification can be determined. In this study, the stability of a horse's gait pattern was evaluated by calculating the standard deviation (S.D.) of motion-cycle speed (MCS). In trot, eighteen horses were analysed at several speeds. The measurements were taken with the ExpertVision System (Motion Anal...
Radiographic assessment of equine interphalangeal joints asymmetry: articular impact of phalangeal rotations (Part I).
Zentralblatt fur Veterinarmedizin. Reihe A    October 30, 1998   Volume 45, Issue 6-7 319-325 doi: 10.1111/j.1439-0442.1998.tb00834.x
Caudron I, Grulke S, Farnir F, Aupaix R, Serteyn D.This study is part of a work to develop a radiographic method that defines objectively the individual conformation of an equine digit and its appropriate trimming. The authors used isolated distal limbs on a rotation support to study the influence of induced foot rotations on several angles measured from specific radiographs. The results of this work enabled the authors to quantify the rotation of the proximal phalanx compared to the distal, and to determine exactly the possible rotation in the distal interphalangeal joint. It was also observed that, faced with a forced rotation of the foot, t...
Muscle-tendon stresses and elastic energy storage during locomotion in the horse.
Comparative biochemistry and physiology. Part B, Biochemistry & molecular biology    October 27, 1998   Volume 120, Issue 1 73-87 doi: 10.1016/s0305-0491(98)00024-8
Biewener AA.The stresses acting in muscle-tendon units and ligaments of the forelimb and hindlimb of horses were determined over a range of speed and gait based on recordings of ground reaction forces and limb kinematics. Maximum stresses of 40-50 MPa were calculated to act in several of the principal forelimb (superficial digital flexor (SDF), deep digital flexor (DDF), ulnaris lateralis (UL) and flexor carpi ulnaris/radialis (FCU/R)) and hindlimb tendons (plantaris, DDF) at the fastest galloping speeds recorded (up to 7.4 m s-1). Smaller stresses were found for the gastrocnemius (GAST) tendon (30 MPa) a...
[The variability and heritability of the indices of speed and exterior characters in horses of the Orlov trotter breed].
TSitologiia i genetika    October 23, 1998   Volume 32, Issue 2 88-91 
Maĭboroda SN.Study of the variability and heritability of sprightliness and exterior characteristics which are the constituent factors of capacity for work of trotting horse breed, permits predicting and planning the direction of selection work in the breed, and determining the efficiency of animals selection according to phenotype. To increase the level of capacity for work of Orloff trotting horse breed, according to the paper data, more consideration should be given to correctness of the exterior, as a biomechanical basis of the horse motion.
Net joint moments and powers in the equine forelimb during the stance phase of the trot.
Equine veterinary journal    October 3, 1998   Volume 30, Issue 5 384-389 doi: 10.1111/j.2042-3306.1998.tb04505.x
Clayton HM, Lanovaz JL, Schamhardt HC, Willemen MA, Colborne GR.The objective of this study was to provide normative data describing the net joint moments and joint powers for the stance phase of the forelimb in trotting horses. Kinematic and force plate data, synchronised in time and space, were collected for the right forelimb of 6 Warmblood horses moving at a trot. The 3-D kinematic data were collapsed onto a sagittal plane, and were combined with the vertical and longitudinal ground reaction forces and with segment morphometric data to calculate net joint moments in the sagittal plane across the distal interphalangeal (coffin), metacarpophalangeal (fet...
An objective method for evaluating the flexibility of the back of standing horses.
Equine veterinary journal    October 3, 1998   Volume 30, Issue 5 412-415 doi: 10.1111/j.2042-3306.1998.tb04511.x
Licka T, Peham C.The spinal movements in maximum arching, dipping and left and right lateral flexion were measured in 10 horses without signs of back pain. A system for motion analysis (Expert Vision System) was used to identify the position of the markers placed on the head, the spinous processes of T5, T10, T16, L3, and on 2 of the sacral spines. By definition, the maximum of the spinal movement was set when the T16 marker reached its maximum deviation from the start position. The difference between start position and maximum position was presented as per cent of the horse's height at the withers. At T16 the...
Effect of three types of half-limb casts on in vitro bone strain recorded from the third metacarpal bone and proximal phalanx in equine cadaver limbs.
American journal of veterinary research    September 15, 1998   Volume 59, Issue 9 1188-1193 
Schneider RK, Ratzlaff MC, White KK, Hopper SA.To determine effect of 3 half-limb casts on bone strains recorded from the proximal phalanx (P-1) and third metacarpal bone (MCIII) of equine cadaver limbs, using a mechanical testing machine. Methods: 12 equine cadaver limbs and 4 live horses. Methods: Bone strains were recorded at middorsal P-1 and the dorsal cortical aspect of the distal third of MCIII while limbs were variably loaded with 100 to 1,000 lb of force. To determine ability of the cast to protect the distal portion of the limb from weight-bearing loads, strains were recorded with the limb in 1 of the 3 casts and with it unsuppor...
Mechanical properties of the tendinous equine interosseus muscle are affected by in vivo transducer implantation.
Journal of biomechanics    September 4, 1998   Volume 31, Issue 5 485-490 doi: 10.1016/s0021-9290(98)00023-2
Jansen MO, Schamhardt HC, van den Bogert AJ, Hartman W.Liquid metal strain gauges (LMSGs) were implanted in the tendinous interosseous muscle, also called suspensory ligament (SL), in the forelimbs of 6 ponies in order to quantify in vivo strains and forces. Kinematics and ground reaction forces were recorded simultaneously with LMSG signals at the walk and the trot prior to implantation, and 3 and 4 days thereafter. The ponies were euthanised and tensile and failure tests were performed on the instrumented tendons and on the tendons of the contra lateral limb, which were instrumented post mortem. The origo-insertional (OI) strain of the SL was co...
A model equation for the prediction of mechanical internal work of terrestrial locomotion.
Journal of biomechanics    September 4, 1998   Volume 31, Issue 5 463-468 doi: 10.1016/s0021-9290(98)00038-4
Minetti AE.By refining a previously published model, a simple equation for the estimation of the mechanical internal work during locomotion is presented. The only input variables are the progression speed, the stride frequency and the duty factor, i.e. the fraction of the stride duration at which a foot is in contact with the ground. The inclusion of this last variable, easily measurable, allows to obtain a single equation for both walking and running. The model predictions have been compared with the mechanical internal work experimentally obtained on humans in several conditions: speeds (range 0.8-3.3 ...
Effect of density and weight of load on the energy cost of carrying loads by donkeys and ponies.
Tropical animal health and production    August 28, 1998   Volume 30, Issue 1 67-78 doi: 10.1023/a:1005021729061
Pearson RA, Dijkman JT, Krecek RC, Wright P.Two experiments were designed to compare the energy used in carrying loads by donkeys and ponies. In the first experiment 3 donkeys and 3 ponies were compared on treadmills in the UK. Density of load (lead shot or straw) had no significant effect on the energy cost of carrying loads; however, the energy cost of carrying a load decreased significantly (p < 0.001) as the weight of the load increased (in donkeys 6.44, 4.35 and 3.03 J/kg load/m, in ponies 5.82, 3.75 and 3.68 J/kg load/m, for loads of 13, 20 and 27 kg/100 kg liveweight (M) respectively). Differences between species were not sign...
Asymmetry in placement of bilateral skin markers on horses and effects of asymmetric skin marker placement on kinematic variables.
American journal of veterinary research    August 26, 1998   Volume 59, Issue 8 938-944 
Audigié F, Pourcelot P, Degueurce C, Denoix JM, Geiger D, Bortolussi C.To evaluate asymmetry in placement of bilateral skin markers on horses and to determine effect of asymmetric skin marker placement on kinematic variables for trotting horses. Methods: 10 horses for evaluation of asymmetry in marker placement; 1 horse for evaluation of effects on kinematic variables. Methods: Asymmetry in marker placement was assessed by attaching markers to horses and comparing radiographs of left and right limbs. An experimental model was developed to determine effects on kinematic variables; accuracy of the model was validated experimentally. Using kinematic data from a clin...
The effects of intra-articular methylprednisolone and exercise on the mechanical properties of articular cartilage in the horse.
Osteoarthritis and cartilage    August 6, 1998   Volume 6, Issue 2 106-114 doi: 10.1053/joca.1997.0100
Murray RC, DeBowes RM, Gaughan EM, Zhu CF, Athanasiou KA.Intra-articular corticosteroids are widely used as anti-inflammatory agents for symptomatic management of arthritis, but their administration with concurrent exercise remains controversial. Biochemical and morphologic analysis of treated cartilage has revealed conflicting results, but previous biomechanical assessment has not been undertaken. Objective: To compare the biomechanical properties of intra-articular methylprednisolone acetate (MPA) and diluent treated cartilage in treadmill exercised horses. Methods: Eight 2-year-old female horses had MPA or diluent administered into contralateral ...
Measurement of the lateral thoracic reflex latency in ponies.
Journal of veterinary internal medicine    August 1, 1998   Volume 12, Issue 4 310-312 doi: 10.1111/j.1939-1676.1998.tb02127.x
Hahn CN, Mayhew IG, Washbourne JR.Lateral thoracic nerve reflex latencies values were measured in ponies using a simple, non-invasive technique. The reflex was elicited using an external triggering hammer attached to an electrodiagnostic unit. The resulting evoked, compound muscle action potentials were recorded with electrodes, which were placed over the 6th ribs or 11th rib level with the axilla. Two superimposed repeats of 4 signal-averaged sweeps of 50 or 100 milliseconds were recorded and the estimated reflex pathway was measured for each subject in order to calculate the reflex latencies and latency velocities. Mean left...
1 65 66 67 68 69 85