Analyze Diet

Topic:Cadaver Study

Cadaver studies involving horses provide valuable insights into equine anatomy, pathology, and surgical techniques. These studies involve the examination and dissection of deceased horses to better understand the structure and function of various bodily systems. By utilizing cadavers, researchers and veterinary students can gain hands-on experience in identifying anatomical features, understanding disease processes, and refining surgical skills without the ethical concerns associated with live animal experimentation. Cadaver studies also contribute to the development of new diagnostic and therapeutic approaches by allowing for detailed exploration of equine anatomy and pathology. This page compiles peer-reviewed research studies and scholarly articles that explore the methodologies, findings, and applications of cadaver studies in equine science.
Post-mortem ultrasonographic and computed tomographic features of the anatomical variations and acquired pathological bony changes of the lumbosacroiliac region in a mixed population of horses.
Equine veterinary journal    December 8, 2023   doi: 10.1111/evj.14033
Scilimati N, Beccati F, Pepe M, Angeli G, Dall'Aglio C, Di Meo A.Transrectal ultrasonography is the best technique for evaluating the ventral aspect of the lumbosacral and sacroiliac regions yet this diagnostic technique does not always lead to a final diagnosis of back pain in horses. Objective: To describe anatomical variations and acquired pathological bony changes (APBCs) in the lumbosacral and sacroiliac regions detected by ultrasonography (US) and computed tomography (CT) examinations on specimens. We hypothesised that age, body mass, previous use and anatomical variations may be correlated with the presence and/or severity of APBCs. Methods: Descript...
Computer-assisted surgery for placing toggle constructs across the coxofemoral joints of small equids using a minimally invasive approach-A proof-of-concept cadaveric study.
Veterinary surgery : VS    July 26, 2023   doi: 10.1111/vsu.14004
Claeys I, Van der Vekens E, Kümmerle J, de Preux M, Koch C.To develop a minimally invasive technique for placing a toggle construct across the coxofemoral joint of small equids using computer-assisted surgery. Methods: Experimental cadaveric study. Methods: Three pilot specimens: One donkey, one Shetland pony and one Warmblood foal. Six main study specimens: Three Shetland ponies, one American Miniature Horse, one Warmblood foal and one donkey. Methods: Experimental surgeries were performed on both coxofemoral joints of each cadaver. Using a minimally invasive surgical approach, 5.5 mm bone canals were drilled through the femur and acetabulum, trave...
Comparison of cone-beam and fan-beam computed tomography and low-field magnetic resonance imaging for detection of proximal phalanx dorsoproximal osteochondral defects.
Equine veterinary journal    July 24, 2023   doi: 10.1111/evj.13973
Lin ST, Bolas NM, Sargan DR, Restif O, Peter VG, Pokora R, Patrick H, Foote AK, Murray RC.Dorsoproximal osteochondral defects commonly affect the proximal phalanx, but information about diagnosis on computed tomography (CT) and magnetic resonance imaging (MRI) is limited. Objective: To assess CT and MRI diagnoses of osteochondral defects, describe the lesions and compare sensitivity and specificity of the modalities using macroscopic pathology as gold standard. Methods: Cross-sectional study. Methods: Thirty-five equine cadaver limbs underwent standing cone-beam CT (CBCT), fan-beam CT (FBCT), low-field MRI and pathological examination. CT and MR images were examined for proximal ph...
Diagnostic Performance of Multi-Detector Computed Tomography Arthrography and 3-Tesla Magnetic Resonance Imaging to Diagnose Experimentally Created Articular Cartilage Lesions in Equine Cadaver Stifles.
Animals : an open access journal from MDPI    July 14, 2023   Volume 13, Issue 14 doi: 10.3390/ani13142304
Bolz NM, Sánchez-Andrade JS, Torgerson PR, Bischofberger AS.The purpose of the study was to determine the diagnostic performance of computed tomographic arthrography (CTA) and 3-Tesla magnetic resonance imaging (MRI) for detecting artificial cartilage lesions in equine femorotibial and femoropatellar joints. Methods: A total of 79 cartilage defects were created arthroscopically in 15 cadaver stifles from adult horses in eight different locations. In addition, 68 sites served as negative controls. MRI and CTA (80-160 mL iodinated contrast media at 87.5 mg/mL per joint) studies were obtained and evaluated by a radiologist unaware of the lesion distributi...
Single energy metal artifact reduction performs better than virtual monoenergetic dual-energy reconstruction in CT of the equine proximal phalanx. Faulkner JE, Broeckx BJG, Martens A, Raes E, Haardt H, Vanderperren K.Metal artifacts in CT negatively impact the evaluation of surgical implants and the surrounding tissues. The aim of this prospective experimental study was to evaluate the ability of a single energy metal artifact reduction (SEMAR™, Canon) algorithm and virtual monoenergetic (VM) dual-energy CT (DECT) scanning techniques to reduce metal artifacts from stainless steel screws surgically inserted into the equine proximal phalanx. Seven acquisitions of 18 cadaver limbs were performed on a Canon Aquilion One Vision CT scanner (Helical +SEMAR, Volume +SEMAR, Standard Helical, Standard Volume and V...
Three-dimensional models of the equine larynx can be used to perform traditional measures of arytenoid abduction and permit the positioning of modeled implants to demonstrate the anatomic feasibility of placing a rigid implant across the cricoarytenoid joint.
American journal of veterinary research    May 13, 2023   Volume 84, Issue 6 ajvr.22.11.0202 doi: 10.2460/ajvr.22.11.0202
Roe HA, Biedrzycki AH, Davenport PW, Freeman DE, Porter EG, McCarrel TM.To develop 3D models of larynges to compare arytenoid abduction measurements between specimens and models, and to investigate the anatomic feasibility of placing an implant across the cricoarytenoid joint (CAJ) with or without arthrotomy. Methods: Cadaveric equine larynges (n = 9). Methods: Equine larynges underwent sequential CT scans in a neutral position and with 2 arytenoid treatments: bilateral arytenoid abduction (ABD) and bilateral arytenoid abduction after left cricoarytenoid joint arthrotomy (ARTH). Soft tissue, cartilage, and luminal volume 3-dimensional models were generated. Rima g...
Computational fluid dynamic analysis of upper airway procedures in equine larynges.
Frontiers in veterinary science    April 17, 2023   Volume 10 1139398 doi: 10.3389/fvets.2023.1139398
Tucker ML, Wilson DG, Bergstrom DJ, Carmalt JL.Computational fluid dynamics (CFD) has proven useful in the planning of upper airway surgery in humans, where it is used to anticipate the influence of the surgical procedures on post-operative airflow. This technology has only been reported twice in an equine model, with a limited scope of airflow mechanics situations examined. The reported study sought to widen this application to the variety of procedures used to treat equine recurrent laryngeal neuropathy (RLN). The first objective of this study was to generate a CFD model of an box model of ten different equine larynges replicating RLN a...
Blind Versus Ultrasound-Guided Low-Volume Perineural Injection of Tibial and Fibular Nerves in Equine Cadaver Limbs.
Journal of equine veterinary science    March 28, 2023   Volume 126 104299 doi: 10.1016/j.jevs.2023.104299
Colla S, Seabaugh KA, Zanotto GM, Selberg K.Techniques for local anesthesia of the tibial (TN) and superficial and deep fibular nerves (FNs) in horses are well established. Ultrasound-guided perineural blocks can identify the nerve location, reduce the anesthetic volume needed and avoid needle misplacement. The aim of this research was to compare the success of blind perineural injection technique (BLIND) to ultrasound-guided technique (USG). Fifteen equine cadaver hindlimbs were divided into two groups. Perineural injection of the TN and FNs was performed using a mixed solution of radiopaque contrast, saline and food dye. BLIND (n = ...
Post-Mortem Computed Tomographic Features of the Most Caudal Lumbar Vertebrae, Anatomical Variations and Acquired Osseous Pathological Changes, in a Mixed Population of Horses.
Animals : an open access journal from MDPI    February 19, 2023   Volume 13, Issue 4 743 doi: 10.3390/ani13040743
Scilimati N, Angeli G, Di Meo A, Dall'Aglio C, Pepe M, Beccati F.The radiographic, ultrasonographic, and scintigraphic findings of horses with thoracolumbosacral pain have been previously reported. In this study, the computed tomographic appearance of anatomical variations and pathological changes of the equine caudal lumbar region through a post-mortem examination were investigated. A total of 40 horses that had died or were submitted for euthanasia, for reasons unrelated to the study, were included in the study. From all the specimens, the modified vertebral system was adopted to evaluate and describe the four most caudal lumbar vertebrae, which were numb...
Minimally Invasive Arthrodesis of the Equine Proximal Interphalangeal Joint: A Biomechanical Comparison of Three 5.5-mm Cortical Screws Inserted in Lag Fashion and Two 7.0-mm Headless Cannulated Dual-Pitch Compression Screws.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    February 9, 2023   Volume 36, Issue 4 184-192 doi: 10.1055/s-0043-1761244
Rumpel AS, De Carvalho AL, Vassoler JM, Schmidt ML, Mertz CC, Rozo CAC, Campos JK, Alievi MM. The aim of this study was to compare the biomechanical properties of two minimally invasive arthrodesis techniques of the equine proximal interphalangeal (PIP) joint (three transarticular 5.5-mm cortical screws [AO-3TLS] vs. two transarticular 7.0-mm headless cannulated multi-use compression screws [MUC-2TS]) in dynamic non-destructive testing and compression testing to failure. Methods:  The experimental study included six pairs of cadaveric adult equine forelimbs; one limb from each horse was randomly assigned to one of the treatments, and the contralateral limb was submitted to the rem...
Percutaneous full endoscopic foraminotomy for treatment of cervical spinal nerve compression in horses using a uniportal approach: Feasibility study.
Equine veterinary journal    January 10, 2023   Volume 55, Issue 5 788-797 doi: 10.1111/evj.13919
Swagemakers JH, Van Daele P, Mageed M.Cervical spinal nerve insult can be a sequel of osteoarthropathy in horses due to enlargement of the articular processes (AP). Objective: To describe the percutaneous endoscopic cervical foraminotomy procedure in horses. Methods: Ex vivo experimental study and clinical case report. Methods: The technique was performed in three equine cadavers and in two clinical cases with history of forelimb lameness located in the caudal cervical region. Briefly, the horse was positioned in lateral recumbency, with the affected AP joint uppermost. Under fluoroscopic guidance, the endoscopic instruments (Ø 6...
Quantification of equine stifle passive kinematics.
American journal of veterinary research    January 2, 2023   Volume 84, Issue 2 ajvr.22.10.0171 doi: 10.2460/ajvr.22.10.0171
He H, Palm-Vlasak LS, Chen C, Banks SA, Biedrzycki AH.This study aims to quantitatively characterize the passive kinematics of the healthy, soft tissue-intact equine stifle to establish an objective foundation for providing insights into the etiology of stifle disorders and developing a possible surgical treatment for stifle degenerative disease. Methods: 5 whole-horse specimens. Methods: Reflective markers with intracortical bone pins and a motion capture system were used to investigate the stifle joint kinematics. Kinematics of 5 whole-horse specimens euthanized within 2 hours were calculated for internal/external rotation, adduction/abduction,...
Comparison of Two Bandage Splint Constructs in an Ex Vivo Equine Metacarpal Fracture Model.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    December 28, 2022   Volume 36, Issue 2 82-86 doi: 10.1055/s-0042-1759867
Granello ME, Weatherall KM, Lutter JD, Beard WL. The aim of this study was to compare the deflection distance, deflection angle and pre-loading sub-bandage pressure of a transverse, mid-metacarpal fracture in an equine cadaver limb when loaded in bending while stabilized with either a Robert Jones Bandage (RJB) or a single-stack bandage (SS), each containing two orthogonal splints. Methods:  In an ex vivo experimental study, forelimb pairs from eight horses were collected, and one forelimb from each pair was assigned to either the SS or RJB groups. A transverse osteotomy was performed at the midpoint of the metacarpus. After bandaging, ...
Evaluation of locking compression plate fixation of the distal phalanx to the hoof wall as a potential therapy for laminitis.
Equine veterinary journal    September 26, 2022   Volume 55, Issue 4 707-716 doi: 10.1111/evj.13877
Lean NE, Zedler ST, Van Eps AW, Engiles JB, Ford M, Stefanovski D, Walsh DM, Pollitt CC.Surgical stabilisation of the distal phalanx (DP) is a potential therapeutic strategy for severe acute laminitis. Objective: To evaluate the effects of locking compression plate (LCP) fixation of the DP to the dorsal hoof wall. Methods: Ex vivo and in vivo experiments. Methods: A T-shaped LCP was applied to one limb per pair in six pairs of cadaver forelimbs subjected to a combination of thermally induced lamellar failure and vertical load to simulate severe acute laminitis. Standard radiographic measurements were used to compare DP displacement. The LCP was then applied to one forefoot in 12 ...
Ex vivo and in vivo evaluation of a modified interrupted Lembert pattern for small intestinal anastomoses in horses.
Veterinary surgery : VS    September 9, 2022   Volume 52, Issue 3 407-415 doi: 10.1111/vsu.13881
Seitz-Cherner E, Bauck AG, Denagamage T, Freeman DE.To compare single-layer anastomoses (modified continuous Lembert [mod-CL] and modified-interrupted Lembert [mod-IL]) and a 2-layer simple continuous anastomosis (2 L; seromuscular and mucosal) for jejunojejunal anastomoses in equine cadavers and to compare ex vivo to in vivo time to complete the anastomosis and stoma size with a mod-IL pattern. Methods: Measurements in jejunum from cadaver and anesthetized horses. Methods: Ten live horses and 18 equine cadavers. Methods: Time to complete anastomosis, bursting pressures (BP), leakage sites, and anastomotic index (size ratio of anastomotic lume...
Intra- and Interexaminer Measurement Variability Analysis of an Orthodontic Gauge Device to Determine Incisor Occlusal Surface Angles in the Horse.
Veterinary sciences    September 7, 2022   Volume 9, Issue 9 481 doi: 10.3390/vetsci9090481
Kau S, Motter KS, Moser VJ, Kunz JR, Pellachin M, Hartl B.Incisor malocclusions are common in horses. As yet, an evidence-based understanding of incisor occlusal surface angle dynamics and normocclusal range is missing. Orthodontic measuring devices could help unravel this information objectively but imply measurement validation. We evaluated intra- and interexaminer variability of repeated sagittal and transversal incisor occlusal surface angle measures using a commercial orthodontic gauge device (). Five examiners (two experienced, three inexperienced) measured six cadaver heads on 2 consecutive days in a blinded block-randomization design, resulti...
Ex-vivo articular cartilage removal from equine proximal interphalangeal joints using cannulated drill bits.
The Canadian veterinary journal = La revue veterinaire canadienne    September 6, 2022   Volume 63, Issue 9 967-970 
Hall NP, Heaton KT, Farnsworth KD, Ragle CA.This report evaluates the use of 4.5- and 5.5-mm cannulated drill bits for articular cartilage removal from the proximal interphalangeal joints of equine cadaver limbs. Limbs from 8 equine cadavers, all with normal proximal interphalangeal joints. Proximal interphalangeal joints of 32 limbs from 8 equine cadavers were drilled using either 4.5- or 5.5-mm cannulated drill bits. Pastern joints were then disarticulated, and intra-articular drilling was evaluated by visual inspection. Post-drilling evaluation revealed complete intra-articular drilling occurred in all 32 joints. Canulated 4.5- and 5...
Proximal sesamoid bone microdamage is localized to articular subchondral regions in Thoroughbred racehorses, with similar fracture toughness between fracture and controls.
Veterinary surgery : VS    June 7, 2022   Volume 51, Issue 6 952-962 doi: 10.1111/vsu.13816
Luedke LK, Ilevbare P, Noordwijk KJ, Palomino PM, McDonough SP, Palmer SE, Basran PS, Donnelly E, Reesink HL.To determine whether proximal sesamoid bone (PSB) microdamage and fracture toughness differ between Thoroughbred racehorses sustaining PSB fracture and controls. Methods: Cadaveric case-control. Methods: Twenty-four Thoroughbred racehorses (n = 12 PSB fracture, n = 12 control). Methods: Proximal sesamoid bones were dissected, and gross pathological changes and morphological measurements were documented. High-speed exercise history data were evaluated. Microdamage was assessed in fracture, fracture-contralateral limb (FXCL) and control PSBs using whole bone lead uranyl acetate (LUA) stainin...
Influence of unilateral and bilateral vocal cordectomy on airflow across cadaveric equine larynges at different Rakestraw grades of arytenoid abduction.
Veterinary surgery : VS    May 24, 2022   Volume 51, Issue 6 974-981 doi: 10.1111/vsu.13823
Lean NE, Bertin FR, Ahern BJ.To assess the effect of vocal cordectomy on airflow across equine larynges at different Rakestraw grades of arytenoid abduction using a unidirectional airflow model. Methods: Ex vivo, repeated measures. Methods: Twenty cadaveric equine larynges. Methods: The right arytenoid cartilage was maximally abducted in all larynges. Each larynx was assigned a Rakestraw grade A or B, and the left arytenoid was abducted accordingly. Each larynx was tested under 3 conditions: intact, left vocal cordectomy (LVC), and bilateral vocal cordectomy (BVC). Translaryngeal pressure and airflow were measured, and di...
The Equine Temporomandibular Joint: Comparisons Between Standard and Needle Arthroscopic Examination of Cadaver Specimens and Standing Horses.
Frontiers in veterinary science    April 26, 2022   Volume 9 876041 doi: 10.3389/fvets.2022.876041
Carmalt JL, Pimentel KL.Definitive diagnosis of equine temporomandibular joint osteoarthritis (TMJ-OA) may require advanced diagnostic imaging. Arthroscopy is a modern, minimally invasive, diagnostic, and treatment modality. Standing arthroscopic treatment of joint disease is a relatively recent advance in equine surgery, despite which there are few published comparisons between the available arthroscopic systems. Unassigned: To compare and contrast two arthroscopic systems for assessing the equine temporomandibular joint compartments in cadavers and standing horses. Unassigned: Experimental study. Unassigned: Phase ...
Effect of single and double hemitenotomy on equine deep digital flexor tendon length and strength in experimental load challenges.
Veterinary surgery : VS    April 18, 2022   Volume 51, Issue 7 1153-1160 doi: 10.1111/vsu.13808
Zetterström SM, Boone LH, Farag R, Weimar WH, Caldwell FJ.To evaluate a double hemitenotomy (DHT) technique as an alternative to complete deep digital flexor (DDFT) tenotomy. Methods: Experimental ex vivo study. Methods: Isolated DDFTs (n = 30) and cadaveric forelimbs (n = 16). Methods: In part 1, 15 isolated DDFT pairs were used. Two hemitenotomies were created in 1 DDFT while the other served as reference. Monotonic tensile load was applied. Tendon lengthening, load reduction, and load at failure were recorded. In part 2, 16 cadaveric forelimb pairs were subjected to DHT followed by complete tenotomy (CT) under monotonic compressive load. Diffe...
Three-Dimensional Modeling and In Silico Kinematic Evaluation of Interspinous Ligament Desmotomy in Horses.
Frontiers in bioengineering and biotechnology    April 1, 2022   Volume 10 817300 doi: 10.3389/fbioe.2022.817300
Biedrzycki AH, Elane GL. Interspinous ligament desmotomy (ISLD) has been shown to improve the comfort of horses diagnosed with overriding dorsal spinous processes (DSP), but its effects on spine mobility are unknown. To objectively quantify the change in mobility of thoracic vertebrae following ISLD using CT and medical modeling software. Prospective cadaveric manipulation of seven equine thoracolumbar spines collected from T11-L1. Spines were collected from T11-L1 with the musculature intact. Flexion and extension phases were achieved with a ratchet device calibrated to 2000N. Bone volume CT scans were performed ...
Early incisor lesions and Equine Odontoclastic Tooth Resorption and Hypercementosis: Reliability of radiographic findings.
Equine veterinary journal    March 28, 2022   Volume 55, Issue 2 261-269 doi: 10.1111/evj.13577
Albers L, Albers J, Dullin C, Staszyk C, Bienert-Zeit A.In clinical practice, early diagnosis of Equine Odontoclastic Tooth Resorption and Hypercementosis (EOTRH) and other resorptive incisor diseases is difficult to achieve. The radiographic appearance of subtle pathological changes has not been described in detail and might be confused with age-related changes. Objective: The study was performed to define typical radiographic signs of early incisor lesions and to evaluate the reliability of the radiographic findings. Methods: Descriptive and comparative study using post mortem clinical, radiographic, macroscopic and µCT examination. Methods: The...
Influence of screw head diameter on ex vivo fixation of equine lateral condylar fractures with 5.5 mm cortical screws.
Veterinary surgery : VS    March 18, 2022   Volume 51, Issue 4 576-591 doi: 10.1111/vsu.13797
Constant C, Zderic I, Arens D, Pugliese B, Gehweiler D, Gueorguiev-Rüegg B, Zeiter S.To determine the influence of screw head diameter on equine condylar fracture fixation with 5.5 mm cortical screws. Methods: Ex vivo, biomechanical study, blinded, matched-pair design. Methods: Fifteen pairs of equine third metacarpal (MC3) bones. Methods: Lateral condylar fractures were simulated by parasagittal osteotomies and repaired pairwise by 2 × 5.5 mm cortical screws of 8 mm (standard) or 10 mm (modified) head diameter. Interfragmentary compression at maximum screw insertion torque was measured. The instrumented specimens were pairwise stratified for biomechanical testing u...
X-ray tube operators can be exposed to equal or higher scattered radiation doses to the hand as cassette holders during diagnostic radiographic procedures of the equine vertebral column and limbs.
American journal of veterinary research    March 3, 2022   Volume 83, Issue 5 412-418 doi: 10.2460/ajvr.21.08.0134
Belotta AF, Mayer MN, Waldner CL, Sidhu NP, Robinson KA, Carmalt JL, Freitas FP, Koehncke NK.The objectives of this study were to investigate scattered radiation doses to the hands of equine workers holding the cassette and the x-ray tube by hand, for both limb and vertebral column studies, and to compare the scattered radiation attenuation of lead with radiation protection lead-free gloves. Radiation doses to the hands of the cassette holder in the primary beam were also investigated. Methods: A whole-body horse cadaver. Methods: A portable x-ray unit was used to simulate 6 radiographic study types in the horse cadaver. Doses were measured with no shielding and, for cassette holders,...
Ex vivo biomechanical evaluation of polyester and polyblend suture techniques to perform equine laryngoplasty.
Veterinary surgery : VS    February 7, 2022   Volume 51, Issue 3 497-508 doi: 10.1111/vsu.13777
Pressanto MC, Pascoletti G, Perkins JD, Zanetti EM, Beccati F, Santalucia V, Pepe M.To validate the use of a polyblend tape suture in equine laryngoplasty (PL). Methods: Experimental study. Methods: Thirty-two cadaveric larynges. Methods: Each larynx was randomly assigned to 1 of 4 groups: PL with polyblend tape suture (TigerTape), without (TT) or with a cannula (TTC) in the muscular process of the arytenoid cartilage, and PL with polyester suture (Ethibond), without (EB) or with a cannula (EBC). Construct stiffness, total migration, creep, and drift values were measured after 3000 cycles. The specimens were then loaded to failure to assess their residual properties: load a...
Dynamic three-dimensional computed tomographic imaging facilitates evaluation of the equine cervical articular process joint in motion.
Equine veterinary journal    January 21, 2022   Volume 55, Issue 1 83-91 doi: 10.1111/evj.13560
Schulze N, Werpy N, Gernhardt J, Fritsch G, Hildebrandt T, Vanderperren K, Klopfleisch R, Ben Romdhane R, Lischer C, Ehrle A.Dynamic computed tomography (CT) imaging has been introduced in human orthopaedics and is continuing to gain popularity. With dynamic CT, video sequences of anatomical structures can be evaluated in motion. Objective: To investigate the feasibility of dynamic CT for diagnostic imaging of the equine cervical articular process joints (APJs) and to give a detailed description of the APJ movement pattern. Methods: Descriptive cadaver imaging. Methods: Cervical specimens of twelve Warmblood horses were included. A custom-made motorised testing device was used to position and manipulate the neck spe...
Comparing Blind and Ultrasound-Guided Retrobulbar Nerve Blocks in Equine Cadavers: The Training Effect.
Animals : an open access journal from MDPI    January 9, 2022   Volume 12, Issue 2 154 doi: 10.3390/ani12020154
Hermans H, Lloyd-Edwards RA, Ferrão-van Sommeren AJH, Tersmette AA, Schouten JCM, Serra Bragança FM, van Loon JPAM.In standing ophthalmic surgery in horses, a retrobulbar nerve block (RNB) is often placed blindly for anesthesia and akinesia. The ultrasound (US)-guided RNB may have fewer complications, but the two techniques have only been compared once in equine cadavers. This study compares the techniques for success and complication rates and analyzes the effect of training on US guidance. Twenty-two equine cadavers were divided into three groups: blind RNBs were performed bilaterally in eight cadavers, US-guided RNBs were performed bilaterally in seven cadavers, and after US-guided training, blind RNBs ...
Comparison of Bone Mineral Content of the Equine Third Metacarpal to Total Radiographic Bone Aluminum Equivalents From Unprocessed Digital Radiographs.
Journal of equine veterinary science    December 16, 2021   Volume 110 103837 doi: 10.1016/j.jevs.2021.103837
Emmert BJ, Robison CI, Pritchard A, Nielsen BD.Digital radiographs are common for estimating bone mineral content (BMC) in horses with radiographic bone aluminum equivalents (RBAE). Processing algorithms are used to produce clearer images of digital radiographs in clinical settings, but this distorts RBAE. This study compared RBAE from digital radiographs to BMC from bone ash, and physical and digital morphology measurements. Digital radiographs were taken of six third metacarpals (MCIII) from equine cadavers with an aluminum step wedge penetrometer. A 2-cm transverse section of bone was digitally analyzed and excised from each MCIII. For ...
In vitro motions of the medial and lateral proximal sesamoid bones under mid-stance load conditions are consistent with racehorse fracture configurations.
Journal of biomechanics    November 27, 2021   Volume 130 110888 doi: 10.1016/j.jbiomech.2021.110888
Shaffer SK, Shelly K, Garcia TC, Samol MA, Hill AE, Fyhrie DP, Stover SM.Proximal sesamoid bone (PSB) fractures in racehorses are likely fatigue fractures that occur due to repetitive loads and stress remodeling. The loading circumstances that may induce damage in the PSBs are not well understood. The goal of this study was to determine in three-dimensions, PSB motions relative to the opposing metacarpal condyle during simulated mid-stance loads. Seven equine cadaveric forelimbs were axially loaded in a material testing system to simulate standing and mid-stance walk, trot, and gallop load conditions (1.8-10.5 kN). Joint angles were determined by tracking the posit...
1 2 3 14