The integration of technology in equine management encompasses a range of tools and systems designed to enhance the care, training, and monitoring of horses. This includes wearable devices that track vital signs and activity levels, providing data for health assessments and performance optimization. Advanced imaging techniques, such as thermography and ultrasonography, aid in the diagnosis and treatment of equine injuries and conditions. Additionally, developments in genetic testing contribute to understanding hereditary traits and potential health risks. This page gathers peer-reviewed research studies and scholarly articles that explore the application, effectiveness, and impact of technology in various aspects of equine care and management.
Rodrigues JB, Garrett C, Norris SL, Albuquerque F, Queijo L, Cooke F, Judge A.Working donkeys represent an important source of energy worldwide. Poor working conditions and equipment affect their ability to work. Poorly designed, ill-fitted harness causes inefficient transfer of power and leads to health and welfare issues. Using technology to assess different types of collars provides a better understanding of those that are most efficient for working donkeys. Methods: Seven different collars were tested using pressure pads. Contact area, median, maximum and peak pressures were obtained for the whole collar and critical points. Eight donkeys pulled 20% and 40% of their...
Vitale V, Vezzosi T, Tognetti R, Fraschetti C, Sgorbini M.Recently, the use of smartphone ECG devices has been reported in humans and animals. Nevertheless, as the electrodes of these devices are inseparable, they can create only a precordial reading in veterinary species. Thus, although the smartphone ECG devices are considered valuable as a screening tool for the detection of some common arrhythmias, they are not always a reliable method for the measurement of the duration of the electrical deflections. The objectives of this study were to evaluate the feasibility of a novel smartphone ECG device, to report the readings obtained recorded simultaneo...
Briggs EV, Mazzà C.Detection of hoof-on and -off events are essential to gait classification in horses. Wearable sensors have been endorsed as a convenient alternative to the traditional force plate-based method. The aim of this study was to propose and validate inertial sensor-based methods of gait event detection, reviewing different sensor locations and their performance on different gaits and exercise surfaces. Eleven horses of various breeds and ages were recruited to wear inertial sensors attached to the hooves, pasterns and cannons. Gait events detected by pastern and cannon methods were compared to the r...
Stewart HL, Siewerdsen JH, Nelson BB, Kawcak CE.Access to volumetric imaging modalities, such as magnetic resonance imaging (MRI) and computed tomography (CT), has increased over the past decade and has revolutionised the way clinicians evaluate equine anatomy. More recent advancements have resulted in the development of multiple commercially available cone-beam CT (CBCT) scanners for equine use. CBCT scanners modify the traditional fan-shaped beam of ionising radiation into a three-dimensional pyramidal- or cone-shaped beam of radiation. This modification enables the scanner to acquire sufficient data to create diagnostic images of a regio...
Deacon LJ, Reef VB, Leduc L, de Solis CN.This pictorial essay aims to display the image quality of pocket-sized ultrasound devices and hospital-based equipment to provide clinicians visual information about the potential uses of point-of-care ultrasonography (POCUS) in equine practice. Twenty-two paired images were obtained using traditional ultrasound equipment and pocket-sized ultrasound devices from patients evaluated at veterinary teaching hospitals. Images of many common ultrasound windows and miscellaneous sonographic abnormalities were obtained using pocket-sized ultrasound equipment.
Slusarewicz P, Slusarewicz JH, Nielsen MK.An automated equine fecal egg count test, known as the Parasight System, was modified for use with small ruminants. Modifications included the introduction of a short centrifugation step in a floatation medium, an adjustment in pre-test sample filtering, and training of an image analysis-based egg counting algorithm to recognize and enumerate trichostrongylid eggs. In preliminary assessments, the modified method produced trichostrongylid egg counts comparable to manual McMaster analyses of the same samples from both ovine and caprine sources. The coefficient of determination (R) for the linear...
Williams ZJ, Sage A, Valberg SJ.The coronavirus pandemic abruptly halted all in-person clerkships, or clinical rotations, for clinical veterinary students across the United States. Online clerkships in radiology offered the opportunity to expand the student's ability to interpret medical images but did not allow for the development of physical hands-on imaging skills recognized as core competencies in veterinary medicine. The present report highlights the value of providing veterinary students with a smartphone-associated Butterfly iQ point-of-care ultrasound during a 3-week self-driven virtual clerkship. During the virtual ...
Serra Bragança FM, Broomé S, Rhodin M, Björnsdóttir S, Gunnarsson V, Voskamp JP, Persson-Sjodin E, Back W, Lindgren G, Novoa-Bravo M, Gmel AI....No abstract available
Zhang S, Li Y, Bao Z, Sun N, Lin S.In this study, the effect of pulsed electric field (PEF) on apparent morphology and molecular structure of shell-like ferritin obtained from horse spleen was determined by circular dichroic (CD), fluorescence spectroscopy, Raman spectroscopy, cold field emission scanning electron microscopy (CF-SEM) and transmission electron microscopy (TEM), and verified by molecule dynamics (MD) simulation. After PEF treatment, the α-helix content of the samples reached a minimum value at 10 kV/cm, which indicated that the ferritin structure has been partially unfolded. However, the α-helix content peaked ...
Hagen J, Jung FT, Brouwer J, Bos R.This study aimed to determine whether a hoof-mounted inertial measurement unit (IMU) system would provide similar timing characteristics and step lengths, in walk and trot on different grounds, compared to those of an established optoelectronic motion system. The right hoof of one horse was equipped with an IMU sensor with an optical reference marker on top. Fifteen steps on firm ground, and five on penetrable ground, were performed at walk and trot. Level of agreement between the two measurement systems was determined by assessing the concordance correlation coefficients, accuracy, and precis...
Schwarz J, Vidondo B, Maninchedda UE, Sprick M, Schöpfer MC, Cruz AM. To assess the inter-evaluator and intra-evaluator reliability of a software program used to extract kinematic variables by a commercially available extremity-mounted inertial measurement unit system in sound horses at the trot under soft and hard ground conditions and treadmill exercise. Thirty adult, sound and healthy French Montagne stallions. Data collection was performed with six IMUs strapped to the distal, metacarpal, metatarsal and tibial regions of every horse. Per surface (treadmill, soft and hard ground) 10 stallions were trotted three times. Prior to the analysis done by six eval...
Starke SD, Miles GC, Channon SB, May SA.Visual assessment of equine lameness is an everyday veterinary task suffering from poor diagnostic accuracy. The aim of this study was to quantify the impact of the perceptual learning game 'LamenessTrainer' on skill development. Thirty-six undergraduate veterinary students engaged in four game modules teaching the assessment of fore- and hindlimb lameness. Computer animations of horses in this game displayed 0% (sound) to 70% (moderately lame) vertical movement asymmetry of head and pelvis. Performance, learning effects, diagnostic accuracy, detection thresholds and survey responses were anal...
Darbandi H, Serra Bragança F, van der Zwaag BJ, Voskamp J, Gmel AI, Haraldsdóttir EH, Havinga P.Speed is an essential parameter in biomechanical analysis and general locomotion research. It is possible to estimate the speed using global positioning systems (GPS) or inertial measurement units (IMUs). However, GPS requires a consistent signal connection to satellites, and errors accumulate during IMU signals integration. In an attempt to overcome these issues, we have investigated the possibility of estimating the horse speed by developing machine learning (ML) models using the signals from seven body-mounted IMUs. Since motion patterns extracted from IMU signals are different between bree...
Navas de Solis C, Gilmour LJ, Coleman MC, Watts AE, Bevevino KE, Glass KG, Hardy J, Chaney KP.To determine the effectiveness of a digital interactive multimedia tutorial (DIMT) for preparing veterinary students to perform ultrasonography in horses. Methods: 42 third-year veterinary students. Methods: Students were randomly assigned to 3 instructional methods: independent study (ie, 45 minutes to read a highlighted textbook chapter), lecture (ie, 45-minute lecture by a faculty member), or digital interactive multimedia tutorial (DIMT; ie, 45-minute narrated, interactive module). Written and practical tests were administered after each instruction session. For the practical test, each st...
Di Tocco J, Sabbadini R, Raiano L, Fani F, Ripani S, Schena E, Formica D, Massaroni C.In recent years, wearable devices for physiological parameter monitoring in sports and physical activities have been gaining momentum. In particular, some studies have focused their attention on using available commercial monitoring systems mainly on horses during training sessions or competitions. Only a few studies have focused on the jockey's physiological and kinematic parameters. Although at a glance, it seems jockeys do not make a lot of effort during riding, it is quite the opposite. Indeed, especially during competitions, they profuse a short but high intensity effort. To this extend, ...
Alberti E, Stucchi L, Pesce V, Stancari G, Ferro E, Ferrucci F, Zucca E.Due to compactness and cheapness, smartphone ECG (sECG) could be very useful to equine practitioners. However, previous studies have evaluated the accuracy of sECG in hospitalised horses only. Different conditions in the field could influence the accuracy of the device. The aim of this study is to compare the accuracy of sECG in field and in hospital conditions. Methods: This is a prospective study. Paired standard base-apex ECG (stECG) and sECG were recorded in hospitalised horses and in subjects examined in field conditions. ECGs were analysed for heart rate and rhythm, presence/type of arrh...
Kjellberg L, Morgan K.Interest in the use of open barns on Swedish horse farms is increasing as an alternative to keeping horses in box stalls and as a 2007 law requires phasing out of tie stalls. To provide adequate forage to satisfy welfare requirements for nutrition, gut health and behavioural needs, the use of automated feeding is also increasing. Studies on forage intake rate report wide variation but provide little information on how to introduce horses to an automatic forage station and on how forage intake rate varies in individual horses fed using an automatic forage station. This study documented the proc...
Mitchell KJ, Schwarzwald CC.Heart rate variability (HRV) analysis has been performed on ECG-derived data sets for more than 170 years but is currently undergoing a rapid evolution, thanks to the expansion of the human and veterinary medical technology sector. Traditional HRV analysis was initially performed to identify changes in vago-sympathetic balance, while the most recent focus has expanded to include the use of complex computer algorithms, neural networks and machine learning technology to identify cardiac arrhythmias, particularly atrial fibrillation (AF). Some of these techniques have recently been translated for...
Kil N, Ertelt K, Auer U.Changes in behaviour are often caused by painful conditions. Therefore, the assessment of behaviour is important for the recognition of pain, but also for the assessment of quality of life. Automated detection of movement and the behaviour of a horse in the box stall should represent a significant advancement. In this study, videos of horses in an animal hospital were recorded using an action camera and a time-lapse mode. These videos were processed using the convolutional neural network Loopy for automated prediction of body parts. Development of the model was carried out in several steps, in...
Salau J, Hildebrandt F, Czycholl I, Krieter J.Sensors delivering information on the position of farm animals have been widely used in precision livestock farming. Global Positioning System (GPS) sensors are already known from applications in military, private and commercial environments, and their application in animal science is increasing. However, as trade-offs between sensor cost, battery life and sensor weight have to be made, GPS based studies scheduling long data collection periods and including a high number of animals, have to deal with problems like high hardware costs and data disruption during recharging of sensors. Furthermor...
Epperly E, Whitty JA.Computed tomography (CT) has revolutionized the veterinarian's ability to image the equine skull and led to improved diagnostic accuracy and clarity for surgical planning. The increased cost for this evaluation is offset by more accurate diagnosis and targeted therapy. As novel technology is developed that allows for increased availability of equine head, the price will continue to decrease and more examinations will be performed. New skills are needed for the veterinarian to accurately interpret this modality. This article reviews the normal CT appearance of the equine skull and presents exam...
Hildebrandt F, Krieter J, Büttner K, Salau J, Czycholl I.Group housing is claimed to possibly provide horses with a species-appropriate movement possibility, and hence, better welfare. Thus, this study analyzed the daily walked distances of 51 horses held in one group in a "HIT Active Stable" (Hinrichs Innovation + Technik) in Northern Germany by using global positioning system (GPS) technology during a 7 ½-month time span. The daily walking distances of the whole group, as well as newcomers, were investigated. The horses traveled an average of 8.43 km/day. Linear mixed models were applied. The observation day had a significant effect on the dail...
Kline KE, Moorman VJ.Monitoring activity level has become popular in people and animals. In the horse, these monitors may be helpful for the detection of disease, monitor limb loading after surgery, and assist in rehabilitation. The objective of this study was to evaluate the accuracy of a commercial activity monitor (AM) (FitBit Zip) in horses. In Part 1, four stalled horses had five AMs placed (head, chest, withers, and left forelimb and hindlimbs) with stride length setting of 60.96 cm and were monitored for 24 hours with AM and video. In Part 2, four stalled horses had two AMs placed (left forelimb and hindl...
Yuan C, Du J, Yue M, Ma T.The control network is an important supporting environment for the control system of the heavy ion accelerator in Lanzhou (HIRFL). It is of great importance to maintain the accelerator system's network security for the stable operation of the accelerator. With the rapid expansion of the network scale and the increasing complexity of accelerator system equipment, the security situation of the control network is becoming increasingly severe. Port scanning detection can effectively reduce the losses caused by viruses and Trojan horses. This article uses Go Concurrency Patterns, combined with tran...
Corradini I, Fernández-Ruiz A, Barba M, Engel-Manchado J.Comparisons between smartphone ECG (SpECG) recordings obtained from the right and left sides of the thorax have not been reported in animals. Objective: To evaluate the screening potential of a SpECG obtained from both sides of the thorax and to compare the degree of agreement between the SpECG and a reference ECG (rECG) for measurement of the duration of baseline electrical deflections recorded over both sides of the thorax. Methods: Fifty horses admitted to the equine hospital, university-owned horses, and horses from an endurance riding facility. Methods: Prospective observational study. Si...
Bressan FF, Bassanezze V, de Figueiredo Pessôa LV, Sacramento CB, Malta TM, Kashima S, Fantinato Neto P, Strefezzi RF, Pieri NCG, Krieger JE....Induced pluripotent stem cells (iPSCs) have enormous potential in developmental biology studies and in cellular therapies. Although extensively studied and characterized in human and murine models, iPSCs from animals other than mice lack reproducible results. Herein, we describe the generation of robust iPSCs from equine and bovine cells through lentiviral transduction of murine or human transcription factors Oct4, Sox2, Klf4, and c-Myc and from human and murine cells using similar protocols, even when different supplementations were used. The iPSCs were analyzed regarding morphology, gene and...
Kallerud AS, Marques-Smith P, Bendiksen HK, Fjordbakk CT.A markerless artificial intelligence (AI) system for lameness detection has recently become available but has not been extensively compared with commonly used inertial measurement unit (IMU) systems for detecting asymmetry under field conditions. Objective: Comparison of classification of asymmetric limbs under field conditions and comparison of normalised asymmetry data using a markerless AI system (SleipAI; recorded on a tripod mounted iPhone 14pro [SL]); the Equinosis Q Lameness Locator (LL); the EquiMoves (EM); and subjective evaluation (SE). Methods: Descriptive clinical study. Methods: S...
Fonte JS, Alonso MA, Junior MPM, Gonçalves MA, Pontes JH, Bordignon V, Fleury PDC, Fernandes CB.This retrospective study aimed at identifying factors that contribute to the success of equine in vitro embryo production by intracytoplasmic sperm injection (ICSI). A total of 7993 ovum pick-up (OPU) sessions were performed, totaling 2540 donor mares and semen from 396 stallions. Oocytes were aspirated at multiple sites in Brazil and were sent to the laboratory, within 6 h from OPU, in pre-maturation medium where they were in vitro matured (IVM) followed by ICSI and in vitro embryo culture for 7-8 days. The number of recovered oocytes, matured oocytes, cleaved embryos and blastocysts were us...
Steiss JE, Yuill GT, White NA, Bowen JM.A force plate system for measurement of the vertical component of the force applied by a horse's limb on ground contact was modified. The modifications included use of steel supporting posts for improved durability and an additional strain gauge on each arm of the Wheatstone bridge for increased sensitivity and temperature compensation. Data from clinically normal horses are provided to indicate the performance obtained with these modifications of the force plate system.
Epperly E, Whitty JA.Computed tomography (CT) has revolutionized the veterinarian's ability to image the equine skull and led to improved diagnostic accuracy and clarity for surgical planning. The increased cost for this evaluation is offset by more accurate diagnosis and targeted therapy. As novel technology is developed that allows for increased availability of equine head, the price will continue to decrease and more examinations will be performed. New skills are needed for the veterinarian to accurately interpret this modality. This article reviews the normal CT appearance of the equine skull and presents exam...
Kelemen Z, Grimm H, Long M, Auer U, Jenner F.Recumbency is a prerequisite for horses achieving rapid eye movement (REM) sleep and completing a full sleep cycle. An inability to lie down due to environmental insecurities or pain results in REM sleep deficiency, which can cause substantial impairment of welfare and health. Therefore, the present study used wearable automated sensor technology on 83 horses housed in an animal sanctuary to measure and compare the recumbency, locomotion, and standing time budgets of geriatric horses with and without chronic lameness to younger adult sound and lame horses. Recumbency times ranged from 0 to 319...
Gray BP, Teale P.A simple, low cost system for the backflushing of capillary gas chromatography (GC) columns has been investigated and integrated into a method for the detection of anabolic steroids in equine urine. The modification to the method was simple to make and quick to setup and optimize. The use of backflushing technology was found to offer significant benefits in terms of sample throughput and improved system robustness.
Nanda S, Dalai AK, Gökalp I, Kozinski JA.The organic wastes such as lignocellulosic biomass, municipal solid waste, sewage sludge and livestock manure have attracted attention as alternative sources of energy. Cattle manure, a waste generated in surplus amounts from the feedlot, has always been a chief environmental concern. This study is focused on identifying the candidacy of horse manure as a next generation feedstock for biofuel production through supercritical water gasification. The horse manure was gasified in supercritical water to examine the effects of temperature (400-600°C), biomass-to-water ratio (1:5 and 1:10) and reac...
Hildebrandt F, Krieter J, Büttner K, Salau J, Czycholl I.Group housing is claimed to possibly provide horses with a species-appropriate movement possibility, and hence, better welfare. Thus, this study analyzed the daily walked distances of 51 horses held in one group in a "HIT Active Stable" (Hinrichs Innovation + Technik) in Northern Germany by using global positioning system (GPS) technology during a 7 ½-month time span. The daily walking distances of the whole group, as well as newcomers, were investigated. The horses traveled an average of 8.43 km/day. Linear mixed models were applied. The observation day had a significant effect on the dail...
Schaer BL, Ryan CT, Boston RC, Nunamaker DM.There is a need to determine accelerations acting on the equine hoof under field conditions in order to better assess the risks for orthopaedic health associated with shoeing practices and/or surface conditions. Objective: To measure the acceleration profiles generated in Thoroughbred racehorses exercising at high speeds over dirt racetracks and specifically to evaluate the effect of a toe grab shoe compared to a flat racing plate, using a newly developed wireless data acquisition system (WDAS). Methods: Four Thoroughbred racehorses in training and racing were used. Based on previous trials, e...
Morrison R, Sutton DG, Ramsoy C, Hunter-Blair N, Carnwath J, Horsfield E, Yam PS.Accelerometers are valid, practical and reliable tools for the measurement of habitual physical activity (PA). Quantification of PA in horses is desirable for use in research and clinical settings. The objective of this study was to evaluate a triaxial accelerometer for objective measurement of PA in the horse by assessment of their practical utility and validity. Horses were recruited to establish both the optimal site of accelerometer attachment and questionnaire designed to explore owner acceptance. Validity and cut-off values were obtained by assessing PA at various gaits. Validation study...
Eerdekens A, Deruyck M, Fontaine J, Damiaans B, Martens L, De Poorter E, Govaere J, Plets D, Joseph W.Equine training activity detection will help to track and enhance the performance and fitness level of riders and their horses. Currently, the equestrian world is eager for a simple solution that goes beyond detecting basic gaits, yet current technologies fall short on the level of user friendliness and detection of main horse training activities. To this end, we collected leg accelerometer data of 14 well-trained horses during jumping and dressage trainings. For the first time, 6 jumping training and 25 advanced horse dressage activities are classified using specifically developed models base...
Bouhali O, Bensmail H, Sheharyar A, David F, Johnson JP.Great advances have been made in human health care in the application of radiomics and artificial intelligence (AI) in a variety of areas, ranging from hospital management and virtual assistants to remote patient monitoring and medical diagnostics and imaging. To improve accuracy and reproducibility, there has been a recent move to integrate radiomics and AI as tools to assist clinical decision making and to incorporate it into routine clinical workflows and diagnosis. Although lagging behind human medicine, the use of radiomics and AI in veterinary diagnostic imaging is becoming more frequent...
Canright A, Bescoby S, Dickson J.Detailed knowledge of anatomical systems is vital for clinical veterinary practice. However, students often find it difficult to transfer skills learned from textbooks to real-life practice. In this study, a three-dimensional computer model representing equine paranasal sinus anatomy (3D-ESM) was created and evaluated for its contribution to student understanding of the 3D dynamic nature of the system. Veterinary students and equine professionals at the University of Bristol were randomly allocated into experimental (3D model) and control (2D lecture) groups. A pre-/post-study design was used ...
Janczarek I, Wilk I.Horses intended for leisure riding do not undergo any selection and most often retired sports horses or defective horses are chosen, as a low selling price determines their purchase by a leisure riding center. Unfortunately, horses bought at low prices usually have low utility value, are difficult to handle, require a special or individual approach and do not provide satisfaction in riding. However, neither modern horse breeding nor scientific research address the need to breed horses for leisure activities. There is no clear definition of a model leisure horse and criteria or information for ...
Guyard KC, Montavon S, Bertolaccini J, Deriaz M.Quantitative information on how well a horse clears a jump has great potential to support the rider in improving the horse's jumping performance. This study investigated the validation of a GPS-based inertial measurement unit, namely Alogo Move Pro, compared with a traditional optical motion capture system. Accuracy and precision of the three jumping characteristics of maximum height (Zmax), stride/jump length (lhorz), and mean horizontal speed (vhorz) were compared. Eleven horse-rider pairs repeated two identical jumps (an upright and an oxer fence) several times ( = 6 to 10) at different hei...
Verdegaal EJMM, Howarth GS, McWhorter TJ, Delesalle CJG.Hyperthermia and exertional heat illness (EHI) are performance and welfare issues for all exercising horses. Monitoring the thermoregulatory response allows for early recognition of metabolic heat accumulation during exercise and the possibility of taking prompt and effective preventative measures to avoid a further increase in core body temperature (Tc) leading to hyperthermia. Skin temperature (Tsk) monitoring is most used as a non-invasive tool to assess the thermoregulatory response pre- and post-exercise, particularly employing infrared thermographic equipment. However, only a few studies...
Parsons KJ, Wilson AM.MP3 recorders are readily available, small, lightweight and low cost, providing the potential for logging analogue hoof mounted accelerometer signals for the characterisation of equine locomotion. These, however, require testing in practice. Objective: To test whether 1) multiple MP3 recorders can maintain synchronisation, giving the ability to synchronise independent recorders for the logging of multiple limbs simultaneously; and 2) features of a foot mounted accelerometer signal attributable to foot-on and foot-off can be accurately identified from horse foot mounted accelerometers logged di...
Montgomery JB, Bracamonte JL, Alam MW, Khan AH, Mohammed SK, Wahid KA.This pilot study assessed wireless capsule endoscopy in horses. Image transmission was achieved with good image quality. Time to exit the stomach was variable and identified as one limitation, together with gaps in image transmission, capsule tumbling, and inability to accurately locate the capsule. Findings demonstrate usefulness and current limitations. Cette étude pilote a évalué l’endoscopie par capsule chez les chevaux. La transmission d’images a permis d’obtenir une bonne qualité d’image. Le temps jusqu’à la sortie de l’estomac était variable et identifié comme une li...
Animal-assisted interventions are considered an innovative rehabilitation approach to improve social, emotional, and physical domains in several diseases. Among such treatments, the equine-assisted activities and therapies have been developed to support the conventional approaches. There is growing evidence on the beneficial effects of hippotherapy, whereas few data are available regarding donkey therapy. Herein, we compare such treatments, hypothesizing their best application field to reach the proper therapeutic outcomes.
May A, Gesell-May S, Müller T, Ertel W.Due to recent developments in artificial intelligence, deep learning, and smart-device-technology, diagnostic software may be developed which can be executed offline as an app on smartphones using their high-resolution cameras and increasing processing power to directly analyse photos taken on the device. Objective: A software tool was developed to aid in the diagnosis of equine ophthalmic diseases, especially uveitis. Methods: Prospective comparison of software and clinical diagnoses. Methods: A deep learning approach for image classification was used to train software by analysing photograph...
Di Tocco J, Sabbadini R, Raiano L, Fani F, Ripani S, Schena E, Formica D, Massaroni C.In recent years, wearable devices for physiological parameter monitoring in sports and physical activities have been gaining momentum. In particular, some studies have focused their attention on using available commercial monitoring systems mainly on horses during training sessions or competitions. Only a few studies have focused on the jockey's physiological and kinematic parameters. Although at a glance, it seems jockeys do not make a lot of effort during riding, it is quite the opposite. Indeed, especially during competitions, they profuse a short but high intensity effort. To this extend, ...
Hagen J, Jung FT, Brouwer J, Bos R.This study aimed to determine whether a hoof-mounted inertial measurement unit (IMU) system would provide similar timing characteristics and step lengths, in walk and trot on different grounds, compared to those of an established optoelectronic motion system. The right hoof of one horse was equipped with an IMU sensor with an optical reference marker on top. Fifteen steps on firm ground, and five on penetrable ground, were performed at walk and trot. Level of agreement between the two measurement systems was determined by assessing the concordance correlation coefficients, accuracy, and precis...
Ryan CT, Schaer BL, Nunamaker DM.A device is needed to safely and wirelessly evaluate accelerations experienced by the horse hoof under a variety of surface conditions with the horse exercising at training or racing speeds. Objective: To develop a miniaturised wireless data acquisition system (WDAS) which reliably records hoof accelerations and the times over which they occur in a minimally invasive manner in the exercising Thoroughbred. Methods: The following criteria were set for device development: production of a lightweight and minimally invasive system, which provides an adequate acceleration range, appropriate frequenc...
Logan AA, Nielsen BD, Hallock DB, Robison CI, Popovich JM.A current trend in equine research is technology development to minimize the subjective nature of gait analysis. One such technology is the Tekscan Hoof System, which records force and area loaded by the hooves during motion. The objective of this study was to determine the test-retest reliability of the Tekscan Hoof System between two sessions, and the recordings within those sessions. Four mature Standardbred geldings wore Tekscan Hoof System sensors on both front hooves, secured by glue-on shoes (SoundHorse Technologies). Horses were exercised in AM and PM sessions. In each session, horses ...
Kjellberg L, Morgan K.Interest in the use of open barns on Swedish horse farms is increasing as an alternative to keeping horses in box stalls and as a 2007 law requires phasing out of tie stalls. To provide adequate forage to satisfy welfare requirements for nutrition, gut health and behavioural needs, the use of automated feeding is also increasing. Studies on forage intake rate report wide variation but provide little information on how to introduce horses to an automatic forage station and on how forage intake rate varies in individual horses fed using an automatic forage station. This study documented the proc...
Kang H, Zsoldos RR, Skinner JE, Gaughan JB, Mellor VA, Sole-Guitart A.The frequent monitoring of a horse’s body temperature post strenuous exercise is critical to prevent or alleviate exertional heat illness (EHI) from occurring. Percutaneous thermal sensing microchip (PTSM) technology has the potential to be used as a means of monitoring a horse’s body temperature during and post-exercise. However, the accuracy of the temperature readings obtained, and their relationship to core body temperature are dependent on where they are implanted. This study aimed to document the relationship between core body temperature, and temperature readings obtained using PTSM...
Stein FJ, Geller SC, Carter JC.To determine whether microchips used for identification migrate after implantation in horses, donkeys, and mules. Methods: Prospective study. Methods: 53 horses, donkeys, and mules. Methods: Twenty horses that had had microchips implanted in the nuchal ligament at a veterinary teaching hospital from 1996 through early 2000 were included (group 1), and the poll-to-withers distance and location of the microchip were determined, measured, and recorded. Additionally, the poll-to-withers distance was measured in 16 horses, 12 donkeys, and 5 mules (group 2), and microchips were implanted in the nuch...
Zhang S, Li Y, Bao Z, Sun N, Lin S.In this study, the effect of pulsed electric field (PEF) on apparent morphology and molecular structure of shell-like ferritin obtained from horse spleen was determined by circular dichroic (CD), fluorescence spectroscopy, Raman spectroscopy, cold field emission scanning electron microscopy (CF-SEM) and transmission electron microscopy (TEM), and verified by molecule dynamics (MD) simulation. After PEF treatment, the α-helix content of the samples reached a minimum value at 10 kV/cm, which indicated that the ferritin structure has been partially unfolded. However, the α-helix content peaked ...