Analyze Diet

Topic:Horseshoes

Horseshoes are protective devices attached to the hooves of horses to enhance durability and performance. They are typically made from materials such as steel, aluminum, or composite materials and are designed to protect the hoof from wear and tear, provide traction, and support for various equine activities. The application of horseshoes, known as shoeing, is performed by a farrier and involves careful consideration of the horse's hoof anatomy, activity level, and environmental conditions. Horseshoes can be customized to address specific hoof health issues or performance needs. This page compiles peer-reviewed research studies and scholarly articles that explore the design, application, and impact of horseshoes on equine biomechanics, hoof health, and performance.
The influence of different horseshoes and ground substrates on mid-stance hoof orientation at the walk.
Equine veterinary journal    August 17, 2023   Volume 56, Issue 3 598-606 doi: 10.1111/evj.13990
Reilly PT, van Eps A, Stefanovski D, Pfau T.Horseshoes with modified contact surfaces combined with deformable ground substrates are used to change hoof orientation during mid-stance, for example, for therapeutic reasons. Objective: To measure the effect of horseshoes and ground substrates on sagittal and transverse plane hoof orientation at mid-stance using a dorsal hoof wall mounted triaxial accelerometer. Methods: In vivo experiment, randomised crossover design. Methods: Differences in sagittal and transverse plane angles between standing and mid-stance of the left front hoof of six horses walking with regular horseshoes, egg bar, to...
Effect of shoeing horses with eggbar shoes and shoes with wedge pads on blood flow parameters in the lateral digital artery in the Doppler ultrasound.
Polish journal of veterinary sciences    June 30, 2023   Volume 26, Issue 2 185-193 doi: 10.24425/pjvs.2023.145021
Mieszkowska M, Holak P, Zhalniarovich Y, Mieszkowski M, Domagalska-Stomska K.A sound knowledge of horseshoe impact on blood flow parameters is required for making shoeing decisions and selecting the most appropriate types of shoes. The aim of this study was to determine the effect of horse shoeing with egg bar shoes and shoes with wedge pads on blood flow parameters in the lateral palmar digital artery measured by Doppler ultrasound. The study was conducted on 16 horses divided into two groups. Horses from group 1 were shod with egg bar shoes. Horses from group 2 were shod with shoes with wedge pads. Doppler ultrasound parameters of the lateral palmar digital artery at...
Shoe configuration effects on third phalanx and capsule motion of unaffected and laminitic equine hooves in-situ.
PloS one    May 8, 2023   Volume 18, Issue 5 e0285475 doi: 10.1371/journal.pone.0285475
Aoun R, Charles I, DeRouen A, Takawira C, Lopez MJ.Equine shoes provide hoof protection and support weakened or damaged hoof tissues. Two hypotheses were tested in this study: 1) motion of the third phalanx (P3) and hoof wall deformation are greater in laminitic versus unaffected hooves regardless of shoe type; 2) P3 displacement and hoof wall deformation are greatest while unshod (US), less with open-heel (OH), then egg-bar (EB) shoes, and least with heart-bar (HB) shoes for both hoof conditions. Distal forelimbs (8/condition) were subjected to compressive forces (1.0x102-5.5x103 N) while a real-time motion detection system recorded markers o...
Z-Bar Shoeing Demonstrates Potential for Long-Term Foot Pain Management during an Exercise Training Regimen in a Show Jumping Pony with Uniaxial Palmar Pain.
Case reports in veterinary medicine    April 13, 2022   Volume 2022 8468403 doi: 10.1155/2022/8468403
Sanigavatee K, Poochipakorn C, Charoenchanikran P, Joongpan W, Chanda M.Z-bar shoeing has been implemented to relieve uniaxial palmar pain arising from the structures in the affected region. However, there have been no reports on the long-term application of the z-bar shoe during exercise training regimens. A 10-year-old mixed-breed show jumping pony presented with an occasional short stride and abnormal rhythm while turning during routine exercise for three months. Gait analysis conducted by trotting off on both hard and soft surfaces showed no lameness in the straight line on both types of surfaces. However, right forelimb lameness was detected with moderate and...
Comparison of Heel Movement Between two Different Glue-on Type Shoes and Nailed Shoes in Thoroughbreds.
Journal of equine veterinary science    March 24, 2022   Volume 113 103939 doi: 10.1016/j.jevs.2022.103939
Takahashi Y, Yoshihara E, Takahashi T.Gluing an aluminum shoe onto equine hooves has been known to restrict heel movement and might cause interference with shock absorption and blood flow to the hoof. To investigate the effects of new glue-on type shoes on heel movement, 2 experiments that compared forelimb heel movement between conventional nailed shoes and flexible polyurethane glue-on shoes or Hanton-type shoes, which had 2 side clips for adhesive, were conducted on separate days. A displacement sensor was fixed on the heel to measure the forelimb's mediolateral heel movement. Exercise consisted of walking at 1.7 m/s, trotting ...
The effect of horseshoes and surfaces on horse and jockey centre of mass displacements at gallop.
PloS one    November 23, 2021   Volume 16, Issue 11 e0257820 doi: 10.1371/journal.pone.0257820
Horan K, Kourdache K, Coburn J, Day P, Carnall H, Harborne D, Brinkley L, Hammond L, Millard S, Lancaster B, Pfau T.Horseshoes influence how horses' hooves interact with different ground surfaces, during the impact, loading and push-off phases of a stride cycle. Consequently, they impact on the biomechanics of horses' proximal limb segments and upper body. By implication, different shoe and surface combinations could drive changes in the magnitude and stability of movement patterns in horse-jockey dyads. This study aimed to quantify centre of mass (COM) displacements in horse-jockey dyads galloping on turf and artificial tracks in four shoeing conditions: 1) aluminium; 2) barefoot; 3) GluShu; and 4) steel. ...
The Effect of Horse Shoeing with Egg Bar Shoes and Shoes with Wedge Pads on the Results of Thermal Imaging of the Equine Distal Limb.
Animals : an open access journal from MDPI    May 21, 2021   Volume 11, Issue 6 1479 doi: 10.3390/ani11061479
Mieszkowska M, Adamiak Z, Holak P, Głodek J, Jastrzębska E, Wolińska K, Mieszkowski M.The presented manuscript provides reference for practitioners when measuring normal hoof temperature, as well as controlling the temperature after shoeing with particular shoes. The aim of this study was to determine the effect of horse shoeing with egg bar shoes and shoes with wedge pads on hoof temperature measured by thermography. This was a prospective study conducted on 16 horses. The horses were divided into two groups: horses from group 1 were shod with egg bar shoes, while horses from group 2 were shod with shoes with wedge pads. Thermographic examination was performed below the metaca...
Assessment of the effect of horseshoes with and without traction adaptations on the gait kinetics of nonlame horses during a trot on a concrete runway.
American journal of veterinary research    March 26, 2021   Volume 82, Issue 4 292-301 doi: 10.2460/ajvr.82.4.292
Wang P, Takawira C, Taguchi T, Niu X, Nazzal MD, Lopez MJ.To assess the effect of horseshoes with and without traction adaptations on the gait kinetics of nonlame horses during a trot on a concrete runway. Methods: 5 nonlame adult light-breed horses. Methods: Kinetic data were obtained for each horse when it was trotted across a force platform within a concrete runway unshod (control) and shod with standard horseshoes; standard horseshoes with high profile-low surface area calks, with low profile-high surface area calks, and coated with a thin layer of tungsten carbide (TLTC); and plastic-steel composite (PSC) horseshoes. Kinetic data were obtained f...
Effects of sand, asphalt and 3-degree hind toe or heel elevation on horse kinematics.
The Veterinary record    January 24, 2021   Volume 188, Issue 4 e23 doi: 10.1002/vetr.23
Caure S, Bonomelli N, Carro M, Leveillard D, Blanville F, Mortagne P, Cousty M, Weller R.Although the effects of both the surfaces and plantar angles on equine locomotion have been widely discussed, limited scientific data are available. Methods: Our objectives were to determine the effects of two surfaces (asphalt and sand) and of 3-degree hind toe or heel elevation on horse kinematics in an experimental study. Six saddle horses were shod with a reference shoeing (REF), characterized by a fore aluminium (REF F) and hind steel racehorse (REF H) shoeing. Two dimensional kinematic videos compared horse's kinematic parameters when walking and trotting on asphalt and sand. On asphalt,...
Jockey Perception of Shoe and Surface Effects on Hoof-Ground Interactions and Implications for Safety in the Galloping Thoroughbred Racehorse.
Journal of equine veterinary science    November 21, 2020   Volume 97 103327 doi: 10.1016/j.jevs.2020.103327
Horan K, Kourdache K, Coburn J, Day P, Brinkley L, Carnall H, Harborne D, Hammond L, Millard S, Pfau T.Riding racehorses is a high-risk profession and optimizing safety alongside performance is paramount. Horseshoes play a critical role in providing traction with the ground surface and are therefore a major determinant of safety. However, the subjective perceptions of expert riders influence attitudes towards using different shoes and must be taken into consideration before any changes may be implemented. This study used a questionnaire-based method to evaluate jockey opinion of four shoeing conditions (aluminum, steel, GluShu, and barefoot) trialed at gallop over turf and artificial surfaces. ...
Do Metal Shoes Contract Heels?-A Retrospective Study on 114 Horses.
Journal of equine veterinary science    October 16, 2020   Volume 95 103293 doi: 10.1016/j.jevs.2020.103293
Senderska-Płonowska M, Zielińska P, Żak A, Stefaniak T.Heel contraction is an undesired but common condition in domestic horses. Some authors indicate shoeing as a risk factor. There is a correlation between shoeing and a restriction of heel expansion, but the clinical significance is unknown. This study aimed to evaluate the influence of shoeing and other risk factors, such as age, access to paddock, and breed, on heel contraction. This study included 114 horses, 55 of which were barefoot their whole life and 59 had been shod consistently for at least the previous year. The width and length of the frog were measured. Linear mixed-effects models w...
Attenuation From Shoes and Pads in Equine Nuclear Scintigraphy, With Relevance to Solar Views.
Frontiers in veterinary science    September 24, 2020   Volume 7 516718 doi: 10.3389/fvets.2020.516718
Walker L, Martinelli MJ, Rantanen N, Drumond B, Trostle S.Nuclear scintigraphy can be beneficial in the investigation of equine lameness and poor performance. Images obtained through the sole allow for better identification of a region of increased radionuclide uptake in the foot. The presence of shoes or pads may affect these images. To determine the degree of radioactive attenuation different types of shoes and pads of different thickness and materials were evaluated by placing the material directly on the gamma camera detector acquiring flood images from a point source. The study compared five different types of shoes from 3 different shoeing mate...
Trot Accelerations of Equine Front and Hind Hooves Shod with Polyurethane Composite Shoes and Steel Shoes on Asphalt.
Animals : an open access journal from MDPI    December 11, 2019   Volume 9, Issue 12 1119 doi: 10.3390/ani9121119
Moore LV, Zsoldos RR, Licka TF.The present study investigated accelerations of the front and hind hooves of horses comparing two different shoe types. A standard steel shoe, with studs, pins, and in some instances with toe grabs, was compared to a steel shoe covered on the bottom with a layer of polyurethane. Four horses were used; they trotted in hand on an asphalt track at their self-selected speed. The results showed significantly reduced decelerations during the stance phase with the polyurethane-covered shoes (10th percentile median steel -2.77 g, polyurethane -2.46 g; 0.06) and significantly increased decelerations i...
Understanding the Basic Principles of Podiatry.
The Veterinary clinics of North America. Equine practice    July 17, 2018   Volume 34, Issue 2 391-407 doi: 10.1016/j.cveq.2018.04.015
Bras RJ, Redden R.Foot-related lameness is one of the most frequently encountered problems in the equine industry. Therapeutic shoeing is a frequently used preventative discipline for the treatment of many causes of lameness. The primary goal for therapeutic applications is to offset the mechanical limitations and enhance the healing environment. Equine podiatry is a blend of the 2 highly respected professions each contributing to the task at hand, but neither formally educated and trained as collaborative team members with a common thread of podiatry principles.
Effect of three types of horseshoes and unshod feet on selected non-podal forelimb kinematic variables measured by an extremity mounted inertial measurement unit sensor system in sound horses at the trot under conditions of treadmill and soft geotextile surface exercise.
Veterinary record open    June 18, 2018   Volume 5, Issue 1 e000237 doi: 10.1136/vetreco-2017-000237
Stutz JC, Vidondo B, Ramseyer A, Maninchedda UE, Cruz AM.Therapeutic farriery is part of the management of certain orthopaedic conditions. Non-podal parameters are important as most horses shod with therapeutic shoes are expected to perform again and the choice of shoe type may be influenced by the effects they may have on gait. The aim of this prospective study was to evaluate the effects of three different shoe designs and unshod front feet on forelimb non-podal kinematic variables using an extremity mounted inertial measurement unit (IMU) system under conditions of treadmill and overground exercise on a soft geotextile surface at the trot. Ten so...
Immediate effects of an artificial change in hoof angulation on the dorsal metacarpophalangeal joint angle and cross-sectional areas of both flexor tendons.
The Veterinary record    March 29, 2018   Volume 182, Issue 24 692 doi: 10.1136/vr.104700
Hagen J, Kojah K, Geiger M, Vogel M.Corrective shoeing is used to change hoof angulation with the intention to influence the angulation of the digital joints to reduce strain on associated tendons. The objective of this study is to examine how gradual changes in hoof angulation affect the dorsal metacarpophalangeal joint (DMPJ) angulation and cross-sectional areas (CSAs) of the deep digital flexor tendon (DDFT) and superficial digital flexor tendon (SDFT) concerning the individual toe conformation. Forelimbs of 30 horses were examined barefoot and equipped with 5°, 10° and 20° toe wedges (TWs) and heel wedges (HWs). Phalangea...
Correlations between the equine metacarpophalangeal joint angulation and toe conformation in statics.
Open veterinary journal    March 22, 2018   Volume 8, Issue 1 96-103 doi: 10.4314/ovj.v8i1.15
Hagen J, Kojah K, Geiger M.The angulation of the equine fetlock determines the load of associated tendons and probably their predisposition for injuries. However, it is questionable how the individual toe conformation and tendon properties interact with the dorsal metacarpophalangeal joint angle (DMPJ). Data are needed for a tangible evaluation of the equine limb conformation for more specific orthopaedic treatment. The aim was to evaluate the correlation between the DMPJ, toe conformation and cross-sectional area (CSA) of both flexor tendons; the superficial digital flexor tendon (SDFT) and deep digital flexor tendon (...
The influence of aluminium, steel and polyurethane shoeing systems and of the unshod hoof on the injury risk of a horse kick. An ex vivo experimental study.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    August 1, 2017   Volume 30, Issue 5 339-345 doi: 10.3415/VCOT-17-01-0003
Sprick M, Fürst A, Baschnagel F, Michel S, Piskoty G, Hartnack S, Jackson MA.To evaluate the damage inflicted by an unshod hoof and by the various horseshoe materials (steel, aluminium and polyurethane) on the long bones of horses after a simulated kick. Methods: Sixty-four equine radii and tibiae were evaluated using a drop impact test setup. An impactor with a steel, aluminium, polyurethane, or hoof horn head was dropped onto prepared bones. An impactor velocity of 8 m/s was initially used with all four materials and then testing was repeated with a velocity of 12 m/s with the polyurethane and hoof horn heads. The impact process was analysed using a high-speed camera...
Effects of racetrack surface and nail placement on movement between heels of the hoof and horseshoes of racehorses.
American journal of veterinary research    September 1, 2016   Volume 77, Issue 9 983-990 doi: 10.2460/ajvr.77.9.983
Dahl VE, Hitchens PL, Stover SM.OBJECTIVE To determine the effects of racetrack surface and shoe characteristics on formation of wear grooves in the horseshoes of racehorses. SAMPLES 1,121 horseshoes from 242 Thoroughbred racehorses collected during routine horseshoeing procedures at 4 racetracks with dirt or synthetic surfaces. PROCEDURES Data for 1,014 horseshoes from 233 racehorses were analyzed. Horseshoes were photographed, and length and width of grooves formed at the heels of the solar surface of horseshoes were measured on the photographs. Effects of racetrack, racetrack surface, and shoe characteristics (eg, shoe si...
A preliminary case study of the effect of shoe-wearing on the biomechanics of a horse’s foot.
PeerJ    July 14, 2016   Volume 4 e2164 doi: 10.7717/peerj.2164
Panagiotopoulou O, Rankin JW, Gatesy SM, Hutchinson JR.Horse racing is a multi-billion-dollar industry that has raised welfare concerns due to injured and euthanized animals. Whilst the cause of musculoskeletal injuries that lead to horse morbidity and mortality is multifactorial, pre-existing pathologies, increased speeds and substrate of the racecourse are likely contributors to foot disease. Horse hooves have the ability to naturally deform during locomotion and dissipate locomotor stresses, yet farriery approaches are utilised to increase performance and protect hooves from wear. Previous studies have assessed the effect of different shoe desi...
Changes in movement symmetry over the stages of the shoeing process in military working horses.
The Veterinary record    June 29, 2016   Volume 179, Issue 8 195 doi: 10.1136/vr.103516
Pfau T, Daly K, Davison J, Bould A, Housby N, Weller R.Military working horses perform a high proportion of work on road surfaces and are shod frequently to deal with high attrition rates. The authors investigate the influence of shoeing on movement symmetry as an indirect indicator of mechanical differences affecting force production between contralateral limbs. In this quantitative observational study, inertial sensor gait analysis was performed in 23 Irish sport type horses (4-21 years, 1.58-1.85 m) in full ceremonial work at the King's Troop, Royal Horse Artillery. Changes in two movement symmetry measures (SI: symmetry index; MinDiff: dif...
Bar shoes and ambient temperature are risk factors for exercise-induced pulmonary haemorrhage in Thoroughbred racehorses.
Equine veterinary journal    July 14, 2015   Volume 48, Issue 4 438-441 doi: 10.1111/evj.12458
Crispe EJ, Lester GD, Robertson ID, Secombe CJ.Ambient temperature has been identified as a risk factor for exercise-induced pulmonary haemorrhage (EIPH) in racing Thoroughbreds. This warranted a more expansive investigation of climatic conditions on the incidence and severity of EIPH. The impact of other variables such as the type of bit used, tongue ties and nonstandard shoes has not been reported and also warrant investigation. Objective: To examine the effect of various climatic variables as contributing risk factors for EIPH. Other previously uninvestigated variables as well as standard track and population factors will also be examin...
Effects of aluminum hinged shoes on the structure of contracted feet in Thoroughbred yearlings.
Journal of equine science    July 2, 2015   Volume 26, Issue 2 67-71 doi: 10.1294/jes.26.67
Tanaka K, Hiraga A, Takahashi T, Kuwano A, Morrison SE.We applied aluminum hinged shoes (AHSs) to the club foot-associated contracted feet of 11 Thoroughbred yearlings to examine the effects of the shoes on the shape of the hoof and third phalanx (P III). After 3 months of AHS use, the size of the affected hooves increased significantly, reaching the approximate size of the healthy contralateral hooves with respect to the maximum lateral width of the foot, the mean ratio of the bearing border width to the coronary band width, and the mean ratio of the solar surface width to the articular surface width. These results suggest that the AHSs corrected...
Dynamic testing of horseshoe designs at impact on synthetic and dirt Thoroughbred racetrack materials.
Equine veterinary journal    January 20, 2015   Volume 48, Issue 1 97-102 doi: 10.1111/evj.12360
Mahaffey CA, Peterson ML, Thomason JJ, McIlwraith CW.Different horseshoe designs have been developed in an attempt to optimise footing for equine athletes. Horseshoe performance is assumed to be dependent on the surface and gait, but there are limited data on horseshoe performance on different surfaces, independent of gait variation. Objective: To quantify the dynamic loading for 3 aluminium racing shoe designs on Thoroughbred racetrack surface materials, using a biomechanical surface tester. Methods: A flat racing plate, a serrated V-Grip and a shoe with a 6 mm toe grab and 10 mm heel calks were tested on synthetic and dirt surfaces under t...
Kinetics of the forelimb in horses circling on different ground surfaces at the trot.
Veterinary journal (London, England : 1997)    February 11, 2014   Volume 198 Suppl 1 e20-e26 doi: 10.1016/j.tvjl.2013.09.028
Chateau H, Camus M, Holden-Douilly L, Falala S, Ravary B, Vergari C, Lepley J, Denoix JM, Pourcelot P, Crevier-Denoix N.Circling increases the expression of distal forelimb lameness in the horse, depending on rein, diameter and surface properties of the circle. However, there is limited information about the kinetics of horses trotting on circles. The aim of this study was to quantify ground reaction force (GRF) and moments in the inside and outside forelimb of horses trotting on circles and to compare the results obtained on different ground surfaces. The right front hoof of six horses was equipped with a dynamometric horseshoe, allowing the measurement of 3-dimensional GRF, moments and trajectory of the centr...
External loads on the leading and trailing forelimbs of a jumping horse at landing measured with a dynamometric horseshoe.
Computer methods in biomechanics and biomedical engineering    August 16, 2013   Volume 16 Suppl 1 145-146 doi: 10.1080/10255842.2013.815981
Crevier-Denoix N, Camus M, Falala S, Ravary-Plumioen B, Douilly-Holden L, Robin D, Denoix JM, Chateau H, Pourcelot P.No abstract available
Use of a 3D dynamometric horseshoe for the measurement of grip parameters in a horse cantering on right and left circles on two surfaces.
Computer methods in biomechanics and biomedical engineering    October 4, 2012   Volume 15 Suppl 1 132-134 doi: 10.1080/10255842.2012.713656
Camus M, Chateau H, Holden-Douilly L, Robin D, Falala S, Ravary-Plumiöen B, Pourcelot P, Crevier-Denoix N.No abstract available
The biomechanics of the equine foot as it pertains to farriery.
The Veterinary clinics of North America. Equine practice    July 18, 2012   Volume 28, Issue 2 283-291 doi: 10.1016/j.cveq.2012.06.001
Eliashar E.Shoes were originally applied to horses' feet to protect against excessive wear. Over the years, countless types of shoes and farriery techniques have been developed not only as a therapeutic aid to treat lameness but also to maintain or enhance functionality. The past 3 decades have provided equine veterinarians and farriers with new information relating to limb biomechanics and the effects of various farriery methods. This article describes the principles of foot biomechanics and how they are affected by some of the more common farriery and shoeing techniques.
Use of a pressure plate to analyse the toe-heel load redistribution underneath a normal shoe and a shoe with a wide toe in sound warmblood horses at the walk and trot.
Research in veterinary science    February 17, 2012   Volume 93, Issue 2 1026-1031 doi: 10.1016/j.rvsc.2012.01.010
Oomen AM, Oosterlinck M, Pille F, Sonneveld DC, Gasthuys F, Back W.The objective of this study was to use a pressure plate to quantify the toe-heel load redistribution in the forelimbs of sound warmblood horses with normal shoes and shoes with a wide toe and narrow branches, used empirically in the treatment of superficial digital flexor tendon or suspensory ligament injuries. In a crossover-design study, six horses, randomly shod with normal shoes and shoes with a wide toe, were led over a dynamically calibrated pressure plate to record data from both forelimbs. There were no significant differences between both shoes in the toe-heel index of stance time, pe...
Heel effects on joint contact force components in the equine digit: a sensitivity analysis.
Equine veterinary journal. Supplement    May 27, 2011   Issue 38 475-481 doi: 10.1111/j.2042-3306.2010.00221.x
Noble P, Lejeune JP, Caudron I, Lejeune P, Collin B, Denoix JM, Serteyn D.Whereas the effect of heel configuration on the tension of the suspensory apparatus is well documented in the literature, there are few reports of joint contact force components in the equine distal forelimb. Objective: To improve understanding of the effect of heel configuration on equine digit joint loading, a sensitivity analysis was performed to compare the effect of a raised heel on joint contact force components in the coffin and fetlock joints during the stance phase of the trot. Methods: Four Warmblood horses were used. An inverse dynamic analysis was carried out using kinematic and ki...
1 2 3 5