Noninvasive procedures in horses refer to diagnostic and therapeutic techniques that do not require incision into the body or removal of tissue. These procedures are designed to minimize discomfort and risk to the animal while providing valuable information for veterinary care. Common noninvasive methods include ultrasonography, thermography, and endoscopy, which allow for the examination of internal structures without surgery. Additionally, techniques such as laser therapy and extracorporeal shock wave therapy are employed for treatment purposes. These procedures are beneficial for assessing and managing a variety of conditions, including musculoskeletal disorders and soft tissue injuries. This page compiles peer-reviewed research studies and scholarly articles that explore the application, effectiveness, and advancements of noninvasive procedures in equine medicine.
Crecan CM, Peștean CP.Objective gait analysis provides valuable information about the locomotion characteristics of sound and lame horses. Due to their high accuracy and sensitivity, inertial measurement units (IMUs) have gained popularity over objective measurement techniques such as force plates and optical motion capture (OMC) systems. IMUs are wearable sensors that measure acceleration forces and angular velocities, providing the possibility of a non-invasive and continuous monitoring of horse gait during walk, trot, or canter during field conditions. The present narrative review aimed to describe the inertial ...
Medill SA, Janz DM, McLoughlin PD.Steroid-hormone concentrations from non-invasively obtained biomarkers, like hair, can provide a representation of circulating hormones diffused over relatively long time periods (e.g., weeks or months). The hormone cortisol is often associated with physiological or even psychological stress, while testosterone is strongly associated with male development and reproductive success. Increasingly, studies are using hormone levels derived from hair to make inferences among both domestic animals and wildlife. For horses, all previous hair hormone analysis has been done on companion or working anima...
Piketh G, Williams A, Schliewert EC.Electrocardiography is the method used to monitor the electrical impulses in the heart. These diagnostics are increasingly making use of smartphone-based technologies. The objective of this research was to determine whether the Alivecor KardiaMobile (ECG) smartphone-modulated electrocardiographic device, a novel ECG device, can be used to obtain reliable electrocardiogram (ECG) readings in horses. The device was initially tested in 36 Nooitgedacht pony mares to determine the best site of application, method of skin preparation, and ECG device orientation for reliable ECG tracings. Once the mos...
Gao Y, Yoshida S, Takeyama A, Tagami M, Rajabi-Toustani R, Tsogtgerel M, Nambo Y.Ultrasound examination during late gestation is one of the best methods for monitoring potential pregnancy risks. Enlarged bladder is a urological disorder rarely observed in equine fetuses. This clinical case report aimed to present a case illustrating the development of equine fetal enlarged bladder using transabdominal ultrasound examinations and maternal hormone evaluation during gestation. An 8-year-old Hokkaido native pony was impregnated by embryo transfer, and at 215 days of gestation, abnormalities of the fetal bladder were detected. The bladder volume increased with gestational age, ...
Epper P, Glüge S, Vidondo B, Wróbel A, Ott T, Sieme H, Kaeser R, Burger D.To successfully inseminate mares, precise detection of ovulation time is crucial, especially when using frozen-thawed semen. Monitoring body temperature, as has been described in women, could be a noninvasive way to detect ovulation. The objective of this study was to investigate the relationship between the time of ovulation and the variation of body temperature in mares based on automatic continuous measurements during estrus. The experimental group included 21 mares for 70 analyzed estrous cycles. When the mares showed estrous behavior, they were administered intramuscular deslorelin acet...
Yassin AM, AbuBakr HO, Abdelgalil AI, Farid OA, El-Behairy AM, Gouda EM.One of the most orthopedic problems seen in the equine is osteoarthritis (OA). The present study tracks some biochemical, epigenetic, and transcriptomic factors along different stages of monoiodoacetate (MIA) induced OA in donkeys in serum and synovial fluid. The aim of the study was the detection of sensitive noninvasive early biomarkers. OA was induced by a single intra-articular injection of 25 mg of MIA into the left radiocarpal joint of nine donkeys. Serum and synovial samples were taken at zero-day and different intervals for assessment of total GAGs and CS levels as well as miR-146b, m...
Renaudin CD, Conley AJ.Methods to diagnose and monitor equine pregnancy continue to advance with improved instrumentation enabling the development of novel, non-invasive approaches to assess fetal well-being and viability using ultrasound and endocrine testing. From early embryonic loss to placentitis, that is typically encountered later in gestation, fetal viability and development as well as placental function can be evaluated using two fundamentally different, structural and functional, approaches. Ultrasound provides structural information on embryonic and fetal growth using such parameters as combined thickness...
Khairoun A, Hawkins JF, Moore GE, Lescun TB, Adams SB.Superficial digital flexor tendinitis (SDFT) and proximal suspensory desmitis (PSD) are common causes of lameness in horses. Current treatment options include rest, controlled exercise, administration of anti-inflammatories, intralesional injections, surgery, and electrohydraulic shock wave therapy (ESWT). ESWT is safe, noninvasive, and is used to treat a variety of musculoskeletal abnormalities. Medical records between 2010 and 2021 were reviewed. Horses were separated into two categories: (group 1: ≥ 3 ESWT treatments; group 2: < 3 ESWT treatments). Our objective was to examine the effe...
Darbandi H, Munsters C, Parmentier J, Havinga P.Detection of fatigue helps prevent injuries and optimize the performance of horses. Previous studies tried to determine fatigue using physiological parameters. However, measuring the physiological parameters, e.g., plasma lactate, is invasive and can be affected by different factors. In addition, the measurement cannot be done automatically and requires a veterinarian for sample collection. This study investigated the possibility of detecting fatigue non-invasively using a minimum number of body-mounted inertial sensors. Using the inertial sensors, sixty sport horses were measured during walk ...
Easterwood L, Cohen ND.Evaluating the body temperature of horses is an essential tool for monitoring horse health and biosecurity in groups of horses. Temperatures of horses and foals are determined most often using rectal thermometry. Rectal thermometry has limitations that include safety considerations for horses and humans. Thus, we investigated the agreement between a noncontact infrared thermometer (NCIT) and a rectal digital thermometer in 142 horses and 34 foals. For each horse and foal, measurements using the NCIT were collected from the forehead (n = 2) or neck (n = 1) and with a rectal digital thermome...
Golzari K, Kong Y, Reed SA, Posada-Quintero HF.The continuous monitoring of stress, pain, and discomfort is key to providing a good quality of life for horses. The available tools based on observation are subjective and do not allow continuous monitoring. Given the link between emotions and sympathetic autonomic arousal, heart rate and heart rate variability are widely used for the non-invasive assessment of stress and pain in humans and horses. However, recent advances in pain and stress monitoring are increasingly using electrodermal activity (EDA), as it is a more sensitive and specific measure of sympathetic arousal than heart rate var...
Midon M, Yamada DI, Zangirolami Filho D, Simionato GC, Feringer Junior WH, Conde G, Hofmeister EH.This study evaluated the agreement between invasive blood pressure (IBP) values measured in three different arteries and by an oscillometric device (NIBP) with the ones from the transverse facial artery (FA). Six horses (424.2 ± 40.7 kg) were sedated with xylazine (0.6 mg/kg IV), induced with ketamine (2 mg/kg IV) and midazolam (0.1 mg/kg IV), and maintained with isoflurane (1.2 MAC) for 90 minutes in lateral recumbency. FA, auricular artery (AA), lateral digital artery (LDA), and metatarsal artery (MA) were catheterized, and a standard adult cuff was placed on the tail. IBP and NIBP values w...
Naboulsi R, Cieślak J, Headon D, Jouni A, Negro JJ, Andersson G, Lindgren G.Gene expression differences can assist in characterizing important underlying genetic mechanisms between different phenotypic traits. However, when population-dense tissues are studied, the signals from scarce populations are diluted. Therefore, appropriately choosing a sample collection method that enriches a particular type of effector cells might yield more specific results. To address this issue, we performed a polyA-selected RNA-seq experiment of domestic horse () plucked-hair samples and skin biopsies. Then, we layered the horse gene abundance results against cell type-specific marker ge...
Kang H, Sole-Guitart A, Mellor VA, Gaughan JB, Zsoldos RR.Continuous accurate attainment of the body temperature of foals is important to detect early stages of severe heat stress or fever due to a systemic illness. Among a number of methods to measure body temperature, measuring rectal temperature with a digital thermometer is most frequently used due to being relatively fast and simple method. It is also comparatively accurate and correlates well with the core body temperature. However, this method requires restraining the foal for a few seconds to obtain the temperature, and it can be dangerous for the handling person. Percutaneous thermal sensing...
Collinet A, Grimm P, Jacotot E, Julliand V.Large intestine barrier disturbances can have serious consequences for the health of horses. The loss of mucosal integrity that leads to increased intestinal permeability may result from a local inflammatory immune response following alterations of the microbiota, known as dysbiosis. Therefore, our research aimed to identify noninvasive biomarkers for studying the intestinal permeability and the local inflammatory immune response in horses. Regarding the biomarkers used in other mammalian species, we measured the concentrations of lipopolysaccharides (LPS), reflected by 3-OH C14, C16, and C18 ...
Matsumoto T, Okumura S, Hirata S.This study aimed to apply radar technology to a large quadruped animal. We first developed a non-contact respiration measurement system using millimeter-wave array radar for a horse in standing position. Specifically, we measured the respiration of a stationary domestic horse in stables. Simultaneously, we measured the respiration rate using infrared thermography and developed a method for analyzing the radar information while verifying the rate of agreement. Our results suggested that the radar technology detected breathing and accurately measured the respiration of a horse, despite variation...
Stas EKL, Hermans H, Slenter IJM, Veraa S, Ensink JM.Iris cysts in horses are often asymptomatic and noticed incidentally. However, cysts can cause local corneal oedema and erratic behaviour like shying, decreased performance and head-shaking. Objective: To describe the use of diode laser as a noninvasive treatment option for iris cysts in the horse and to document factors influencing its efficacy, associated complications, long-term outcome and rate of recurrence. Methods: Retrospective case series. Methods: Case records of horses treated for iris cysts by diode laser at the Utrecht University Equine Clinic were reviewed between 2008 and 2020. ...
Pasquiet B, Biau S, Trébot Q, Debril JF, Durand F, Fradet L.Detecting fatigue during training sessions would help riders and trainers to optimize their training. It has been shown that fatigue could affect movement patterns. Inertial measurement units (IMUs) are wearable sensors that measure linear accelerations and angular velocities, and can also provide orientation estimates. These sensors offer the possibility of a non-invasive and continuous monitoring of locomotion during training sessions. However, the indicators extracted from IMUs and their ability to show these locomotion changes are not known. The present study aims at defining which kinemat...
Magalhaes HB, Canisso IF.Practitioners are frequently requested to diagnose and stage pregnancy in donkeys with unknown breeding dates; however, scant work has been done to stage pregnancy in the species. Therefore, this study aimed to determine the association between measurements of fetal aortic, thoracic, and heartbeat with gestational age in donkeys carrying and delivering healthy foals. Multiparous Dezhou donkeys (n = 50) ranging from 4 to 16 years were enrolled in the study by 150 days of gestation. Transabdominal ultrasonography coupled with a 3.5 MHz sectorial convex transducer was performed at 30 day-interv...
Giannetto C, Di Pietro S, Pennisi M, Acri G, Piccione G, Giudice E.In clinical practice, an important aspect of animal health status evaluation is the body temperature recording obtained using different methods. Within them, the non-contact and non-invasive infrared thermometer can provide an accurate estimation of body temperature improving the quality of care and medical decision. To evaluate the use of the monitoring of auricular temperature to improve the quality of care and medical decision. To evaluate the use of the monitoring of auricular temperature as indices of body temperature, as well as rectal temperature in eleven clinically healthy mixed bred ...
Salem M, El-Shafaey ES, Farag AMM, El-Khodery S, Al Mohamad Z, Abass M.This study was conducted to establish a detailed anatomic reference for the carpal joint of apparently healthy donkeys using ultrasonography (US), computed tomographic (CT), and magnetic resonance imaging (MRI). Ten orthopedically sound adult donkeys were used for US examination of the carpal joint in each forelimb. Additionally, the carpi of ten donkey cadavers were subjected to CT and MRI examinations. The carpal joint was divided into four zones to simplify examination. US assessment of the carpal joint included transverse and longitudinal sonograms. CT was performed using three planes: axi...
Price D, Barnum S, Mize J, Pusterla N.The purpose of this study was to explore sampling options for a reliable and logistically more feasible protocol during a large EHV-1 outbreak. Seventeen horses with clinical infection as well as nineteen healthy herdmates, all part of an EHM outbreak, were enrolled in the study. Each horse was sampled two-four times at intervals of 2-6 days during the outbreak. All samples were collected using 6'' rayon-tipped swabs. Nasal secretions were used as the diagnostic sample of choice. Additional samples, including swabs from the muzzle/nares, swabs from the front limbs, rectal swabs, swabs of the f...
Lelláková M, Lešková L, Florián M, Mesarčová L, Skurková L, Peťková B, Takáčová D, Kottferová J.The determination of cortisol concentrations in animal hair appears to be a relatively simple and non-invasive method of assessing chronic stress. This method has advantages but it also has some drawbacks. We discovered that there are specific coat properties and individual factors in animlas that can affect corisol levels and skew the interpretation of results. We removed horsehair from 8 different areas of the body (chest, left saddle, right saddle, right thoracic fetlock, and left thoracic fetlock, the mane was also sampled at the withers, just behind the ears, and the tail strand) in 31 ho...
Wrangberg T, Kendall A. Proper identification of healthy subjects is essential in case-control studies. However, standardized definitions of healthy controls are lacking in equine orthopaedic research. Objective: The aim of this study was to define the non-invasive methods used for selecting healthy control horses in osteoarthritis (OA), desmitis and tendinitis research. Methods: Systematic review. Case-control studies with a healthy control group and longitudinal studies where horses had to be healthy at the start were included. Studies where joints were visualized by arthroscopy or post-mortem examination ...
Gamucci F, Pallante M, Molle S, Merlo E, Bertuglia A.Superficial skeletal muscle activation is associated with an electric activity. Bidimensional High-Density Surface Electromyography (HD-sEMG) is a non-invasive technique that uses a grid of equally spaced electrodes applied on the skin surface to detect and portray superficial skeletal muscle activation. The goal of the study was to evaluate the feasibility of HD-sEMG to detect electrical activation of skeletal muscle and its application during rehabilitation exercises in horses. To fulfil this aim, activation of the superficial descending pectoral and external abdominal oblique core muscles w...
Gavriliuc S, Reza S, Jeong C, Getachew F, McLoughlin PD, Poissant J.The development of high-throughput sequencing has prompted a transition in wildlife genetics from using microsatellites toward sets of single nucleotide polymorphisms (SNPs). However, genotyping large numbers of targeted SNPs using non-invasive samples remains challenging due to relatively large DNA input requirements. Recently, target enrichment has emerged as a promising approach requiring little template DNA. We assessed the efficacy of Tecan Genomics' Allegro Targeted Genotyping (ATG) for generating genome-wide SNP data in feral horses using DNA isolated from fecal swabs. Total and host-sp...
Bizzotto D, Paganini S, Stucchi L, Avallone MP, Ramirez EM, Pompilio PP, Ferrucci F, Lavoie JP, Dellacà RL.. The assessment of lung mechanics in horses is nowadays based on invasive methods that may require sedation. The forced oscillation technique (FOT) allows the non-invasive assessment of respiratory mechanics during spontaneous breathing, but current devices are complex, cumbersome, expensive, and difficult to be applied in horses.. We developed a portable FOT device based on a novel approach in which the pressure waveforms are generated by a servo-controlled ducted fan. This new approach allows the design of devices that are more sturdy, compact, and portable compared to already existing appr...
Pratt S, Barnes TS, Cowling N, de Klerk K, Rainger J, Sole-Guitart A, Woldeyohannes S, Goodwin W.To compare arterial blood pressure (ABP) measured invasively (IBP) to ABP measured non-invasively (NIBP) via oscillometry in healthy anaesthetised and standing horses using the Bionet BM7Vet. Fourteen horses were anaesthetised for elective procedures (anaesthetised group) and 10 horses were enrolled for standing blood pressure manipulation (standing group). In both groups, IBP and NIBP-corrected to heart level were measured every 3 min using the Bionet BM7Vet. The overall mean difference (bias), standard deviation and limits of agreement (LOA) were calculated for paired IBP and NIBP systolic (...
Scardia A, Mariani Pimenta EL, Ross Russell RI, Jones GJ, Staffieri F.The aim of this study was to evaluate the validity of the SpO/FiO diagram in estimating gas exchange in horses under general anaesthesia. In this prospective, controlled clinical study were included 10 horses under general anaesthesia. FiO was progressively reduced with the following steps: 0.6, 0.4, 0.3 and 0.21; SpO was recorded at each step. An arterial blood sample was collected at the steps of 1.0 and 0.21, to calculate intrapulmonary shunt with the Fshunt formula. The Fshunt value calculated at 0.21 FiO was defined as "Fshunt 0.21", the one calculated at 1.0 FiO as "Fshunt 1.0". The FiO ...
Lelláková M, Pavľak A, Lešková L, Florián M, Skurková L, Mesarčová L, Kottferová L, Takáčová D, Kottferová J.To assess stress in horses, a method of monitoring eye blinks (full and half) and eyelid twitches while collecting saliva and blood samples before and after annual intensive police training was carried out. This noninvasive monitoring method was used to determine whether blood collection, which is considered invasive, is more stressful for horses than saliva collection. We discovered no significant difference in stress related manifestations between saliva sampling and blood collection in our study. In both cases, sampling (blood and saliva) reduced the number of full and half eye blinks. Base...
von Borell E, Langbein J, Després G, Hansen S, Leterrier C, Marchant J, Marchant-Forde R, Minero M, Mohr E, Prunier A, Valance D, Veissier I.Measurement of heart rate variability (HRV) is a non-invasive technique that can be used to investigate the functioning of the autonomic nervous system, especially the balance between sympathetic and vagal activity. It has been proven to be very useful in humans for both research and clinical studies concerned with cardiovascular diseases, diabetic autonomic dysfunction, hypertension and psychiatric and psychological disorders. Over the past decade, HRV has been used increasingly in animal research to analyse changes in sympathovagal balance related to diseases, psychological and environmental...
Webb JG, Chandavimol M, Thompson CR, Ricci DR, Carere RG, Munt BI, Buller CE, Pasupati S, Lichtenstein S.Percutaneous aortic valve implantation by an antegrade transvenous approach has been described but is problematic. Retrograde prosthetic aortic valve implantation via the femoral artery has potential advantages. Percutaneous prosthetic aortic valve implantation via the femoral arterial approach is described and the initial experience reported. Results: The valve prosthesis is constructed from a stainless steel stent with an attached trileaflet equine pericardial valve and a fabric cuff. After routine aortic balloon valvuloplasty, a 22F or 24F sheath is advanced from the femoral artery to the a...
Peeters M, Sulon J, Beckers JF, Ledoux D, Vandenheede M.In horses, serum cortisol concentration is considered to provide an indirect measurement of stress. However, it includes both free and bound fractions. The sampling method is also invasive and often stressful. This is not the case for salivary cortisol, which is collected using a more welfare-friendly method and represents a part of the free cortisol fraction, which is the biologically active form. Objective: To compare salivary and serum cortisol assays in horses, in a wide range of concentrations, using an adrenocorticotropic hormone (ACTH) stimulation test, in order to validate salivary cor...
De Schauwer C, Goossens K, Piepers S, Hoogewijs MK, Govaere JL, Smits K, Meyer E, Van Soom A, Van de Walle GR.Mesenchymal stromal cells (MSCs) have been extensively studied for their promising capabilities in regenerative medicine. Although bone marrow is the best-known source for isolating equine MSCs, non-invasive alternative sources such as umbilical cord blood (UCB), umbilical cord matrix (UCM), and peripheral blood (PB) have also been reported. Methods: Equine MSCs from three non-invasive alternative sources were isolated from six individual mares (PB) and their foals (UCB and UCM) at parturition. To minimize inter-horse variability, the samples from the three sources were matched within the same...
Turner TA.Thermography has been shown to be a practical aid in the clinical evaluation of lameness. This modality specifically increases the accuracy of diagnosis. Thermography represents skin temperature, usually pictorially. The techniques involve contacting and noncontacting modalities. Noncontacting thermography, which detects infrared radiation, is the most accurate. In order to be accurate, thermography must be performed in a temperature-controlled, draft-free area. The area should be protected from sunlight to avoid erroneous heating of the skin, and the hair length should be uniform. Thermograph...
Comin A, Veronesi MC, Montillo M, Faustini M, Valentini S, Cairoli F, Prandi A.Stimulation of the hypothalamic-pituitary-adrenal (HPA) axis and elevated cortisol concentrations in fetal plasma are associated with foal maturity, viability and adaptation to independent life. However, non-invasive measurement of cortisol in hair samples has not yet been validated in horses. The current study developed a radioimmunoassay to analyse cortisol in horse hair and was used to measure cortisol hair concentration at birth and at 30 and 60 days of age as a retrospective study of HPA axis activity. Cortisol was detectable in the hair of foals from birth until 2 months, but decreased w...
Haussler KK, Erb HN.An objective measure of neck, back and croup pain is needed in horses with musculoskeletal injuries, vague upper limb lameness or poor performance. Objective: To establish mechanical nociceptive thresholds (MNTs) within the axial skeleton and evaluate the effects of subject status and ridden exercise. Methods: Thirty-six mature horses (10 nonridden; 26 actively ridden) were used to assess MNTs evoked by a pressure algometer (PA) with a 1 cm2 rubber plunger tip at 62 midline and bilaterally symmetrical anatomical landmarks along the axial skeleton. Pressure was applied at a uniform rate of appl...
Goodwin S.Body temperature of goats, horses, and sheep was measured, using 3 methods. Tympanic temperature was measured with a tympanic infrared thermometer, subcutaneous temperature was measured with an implantable microchip transponder, and rectal temperature was measured with a digital thermometer. For goats, rectal and subcutaneous temperatures were significantly higher than tympanic temperatures, but rectal and subcutaneous temperatures did not differ significantly. For horses and sheep, rectal temperatures were significantly higher than tympanic and subcutaneous temperatures, and tympanic temperat...
Witkowska-Piłaszewicz O, Maśko M, Domino M, Winnicka A.In horse racing the most acceptable way to objectively evaluate adaptation to increased exertion is to measure lactate blood concentration. However, this may be stressful for the horse, therefore, a simple, noninvasive procedure to monitor race progress is desirable. Forty Thoroughbreds attended race training, with blood samples collected at rest, immediately after, and 30 min after exercise. The lactate concentration was determined 60 s after blood collection using an Accusport. Thermal imaging of the neck and trunk areas was performed following international veterinary standards from a dista...
Merkies K, Ready C, Farkas L, Hodder A.Physiological changes provide indices of stress responses, however, behavioural measures may be easier to determine. Spontaneous eye blink rate has potential as a non-invasive indicator of stress. Eyelid movements, along with heart rate (HR) and behaviour, from 33 horses were evaluated over four treatments: (1) control-horse in its normal paddock environment; (2) feed restriction-feed was withheld at regular feeding time; (3) separation-horse was removed from visual contact with their paddock mates; and (4) startle test-a ball was suddenly thrown on the ground in front of the horse. HR data wa...
Ugryumova N, Jacobs J, Bonesi M, Matcher SJ.To investigate a novel optical method to determine the three dimensional (3-D) structure of articular cartilage collagen non-destructively. Methods: Polarization-sensitive optical coherence tomography was used to determine the apparent optical birefringence of articular cartilage for a number of different illumination directions. A quantitative method based on the theory of light propagation in uniaxial crystalline materials was validated on equine flexor tendon. Qualitative maps of fiber polar and azimuthal orientation at sites on the posterior and anterior segments of the equine third metaca...
Williams DC, Aleman M, Holliday TA, Fletcher DJ, Tharp B, Kass PH, Steffey EP, LeCouteur RA.The influence of sleep on the equine electroencephalogram (EEG) has not been well documented. Objective: The objectives were to develop a noninvasive method of electrode placement for recording the EEG in horses and to establish normal EEG parameters for the various states of vigilance. Findings are compared with previously published reports on equine sleep based on electrocorticography (ECoG). Methods: Five neurologically normal horses. Methods: Overnight EEGs were recorded digitally in association with simultaneous videotaping of the horses' behavior. Data were analyzed by visual inspection,...
Pease A, Behan A, Bohart G.Horses with intracranial lesions and severe ataxia are not good anesthesia candidates; however, only one method to obtain cerebrospinal fluid (CSF) from the cervical region in a standing horse has been reported. This method is not performed routinely due to the difficulty for sample acquisition. Our hypothesis is that standing cervical centesis can be performed in horses without complication. Ultrasound-guided centesis of the CSF between C1 and C2 in 11 clinically normal horses and two horses with neurologic signs were performed. Horses were sedated and ultrasound was used to identify the suba...
Richard EA, Fortier GD, Denoix JM, Art T, Lekeux PM, Van Erck E.Inflammatory airway disease (IAD) is a nonseptic condition of the lower respiratory tract. Its negative impact on respiratory function has previously been described using either forced expiration or forced oscillations techniques. However, sedation or drug-induced bronchoconstriction were usually required. The impulse oscillometry system (IOS) is a noninvasive and sensitive respiratory function test validated in horses, which could be useful to evaluate IAD-affected horses without further procedures. Objective: To determine the sensitivity of IOS in detecting alterations of the respiratory fun...
Redaelli V, Luzi F, Mazzola S, Bariffi GD, Zappaterra M, Nanni Costa L, Padalino B.The aim of this pilot study was to document the effects of endurance training at different intensities on heart rate (HR), blood count, serum cortisol, and maximal temperatures of different body locations, namely eye, crown, pastern pasterns, and muscle (, measured by infrared thermography technique (IRT) in horses trained for endurance. Possible associations among the studied parameters were also investigated. Our hypothesis was that temperature, measured by IRT after endurance training of different intensities would vary depending on the intensity and would be positively correlated with HR...
Anderson JR, Phelan MM, Clegg PD, Peffers MJ, Rubio-Martinez LM.Osteoarthritis (OA), osteochondrosis (OC), and synovial sepsis in horses cause loss of function and pain. Reliable biomarkers are required to achieve accurate and rapid diagnosis, with synovial fluid (SF) holding a unique source of biochemical information. Nuclear magnetic resonance (NMR) spectroscopy allows global metabolite analysis of a small volume of SF, with minimal sample preprocessing using a noninvasive and nondestructive method. Equine SF metabolic profiles from both nonseptic joints (OA and OC) and septic joints were analyzed using 1D H NMR spectroscopy. Univariate and multivariate ...
Fuller CJ, Barr AR, Sharif M, Dieppe PA.To investigate the relationship between biochemical markers in the synovial fluid of osteoarthritic and contralateral equine joints and gross articular cartilage pathology. Methods: Twenty-two horses underwent bilateral arthroscopy of their carpal or metacarpophalangeal joints following recent onset lameness. The degree of cartilage damage in each joint was scored and synovial fluid, from both the clinically affected and the contralateral joint, was collected. Bone specific alkaline phosphatase (BAP), 5D4 epitope of keratan sulphate (KS), total glycosaminoglycans (GAG) and hyaluronan (HA) were...
Ortega-Ferrusola C, Gracia-Calvo LA, Ezquerra J, Pena FJ.Doppler ultrasonography is an important tool in the andrological evaluation in humans; however, this method is not so extensively used by equine andrologists. Spectral or pulse Doppler is a useful non-invasive method for the early diagnosis of subfertility problems in the male, especially those triggered by vascular disturbance. The identification of any disturbance in the blood flow of the testis is crucial for a correct diagnosis of various testicular and scrotal disorders but also to monitor the therapeutic outcome following treatment. The aim of this review is to provide an update on the c...
Soroko M, Zaborski D, Dudek K, Yarnell K, Górniak W, Vardasca R.The impact of a rider's and saddle's mass on saddle thermal pattern distribution was evaluated using infrared thermography (IRT). Eighteen racehorses were ridden by four riders with their own saddle. Images of the saddle panels were captured at each of six thermographic examinations. On each image, six regions of interest (ROIs) were marked on the saddle panels. The mean temperature for each ROI was extracted. To evaluate the influence of load on saddle fit, 4 indicators were used: ΔTmax (difference between the mean temperature of the warmest and coolest ROI); standard deviation of the mean t...
Nollet H, Van Ham L, Deprez P, Vanderstraeten G.Transcranial magnetic stimulation is rapidly developing as a powerful, non-invasive tool for studying the descending motor tracts in humans. The applications of the test in animals are for the moment restricted to small animals. However, this non-invasive, sensitive and painless technique appears promising as a test of motor tract function in horses where the neurological examination is mainly restricted to clinical evaluation and some ancillary tests, such as radiography, cerebrospinal fluid analysis and electromyography. In this review, we want to discuss the history, basic principles, techn...
Schwarzwald CC, Schober KE, Bonagura JD.Noninvasive assessment of left ventricular (LV) function is incompletely studied in horses. Objective: The goals of this study were to investigate the feasibility, techniques, and reliability of tissue Doppler imaging (TDI) for characterization of LV radial wall motion in healthy horses. Methods: Three Standardbreds, 3 Thoroughbreds; age 8-14 years; body weight 517-606 kg. Methods: Repeated echocardiographic examinations were performed by 2 observers in unsedated horses using TDI. Test reliability was determined by estimating measurement variability, within-day interobserver variability, and b...
Yarnell K, Fleming J, Stratton TD, Brassington R.Infrared thermography (IRT) was used to assess surface temperature change as an indirect measure of muscle activity and exercise associated changes in blood flow in the working hind limb muscles of horses (n=7) undergoing water treadmill exercise. Three treatments were investigated including the treadmill ran dry (TD), water at the height of the proximal interphalangeal joint (PIP) and water at the height of the carpus (CP). Maximum skin surface temperature was recorded from the region of the semitendinosus muscle during exercise at each water height. There was a significant difference in surf...
Jansson A, Lindgren G, Velie BD, Solé M.Infrared thermography (IRT) is a popular technology used for the detection of thermal changes given its non-invasive nature and lack of direct contact with the individual. Accordingly, the maximal eye temperature (MaxET) measured with IRT has been extensively applied in equine research. However, there is little information available about the potential limitations of the MaxET in field studies. Thus, the aims of this study were to 1) quantify the individual variation of MaxET in field conditions and the effects of individual, breed, body size (height at withers), eye side, sex and age, 2) dete...
Leng J, Proudman C, Darby A, Blow F, Townsend N, Miller A, Swann J.Equine grass sickness (EGS) is a frequently fatal disease of horses, responsible for the death of 1 to 2% of the U.K. horse population annually. The etiology of this disease is currently uncharacterized, although there is evidence it is associated with Clostridium botulinum neurotoxin in the gut. Prevention is currently not possible, and ileal biopsy diagnosis is invasive. The aim of this study was to characterize the fecal microbiota and biofluid metabolic profiles of EGS horses, to further understand the mechanisms underlying this disease, and to identify metabolic biomarkers to aid in diagn...
Schwarzwald CC, Schober KE, Berli AS, Bonagura JD.Noninvasive assessment of left-ventricular (LV) function is clinically relevant, but is incompletely studied in horses. Objective: To document the feasibility, describe the techniques, and determine the reliability of 2D speckle tracking (2DST) for characterization of LV radial and circumferential wall motion in horses. Methods: Three Standardbreds, 3 Thoroughbreds; age 8-14 years; body weight 517-606 kg. Methods: Observational study. Repeated 2-dimensional echocardiographic examinations were performed in unsedated horses by 2 observers and subsequently analyzed by 2DST. Test reliability was d...
Heliczer N, Lorello O, Casoni D, Navas de Solis C.Blood pressure is relevant to the diagnosis and management of many medical, cardiovascular and critical diseases. The accuracy of many commonly used noninvasive blood pressure (NIBP) monitors and the accuracy of NIBP measurements in hypo- and hypertensive standing horses has not been determined. Objective: The objective of this study was to investigate the accuracy of an oscillometric BP monitor in standing horses before and during pharmacologically induced hyper- and hypotension and to compare results in standing and anesthetized horses. Methods: Eight standing mares from a research herd (SG)...
Bollwein H, Maierl J, Mayer R, Stolla R.Color Doppler ultrasound was used transrectally in 6 mares to locate both the left and right Aa. uterinae and to obtain flow velocity waveforms at defined times (Days 0, 5, 10, 15 and 20) during 4 estrous cycles. Blood flow reflected by the resistance index (RI) was determined for both arteries on 120 occasions. As there was no significant difference and a high correlation in the RI values between the left and right arteries (paired Student's t-test, correlation coefficient r > 0.94; P < 0.05), the average RI value was used for subsequent analyses. There were correlations between RI valu...
Kinnunen S, Laukkanen R, Haldi J, Hanninen O, Atalay M.Endurance training induces changes in autonomic nervous system functions. High intensity training includes the risk of overtraining, in man and horse. Heart rate variability (HRV) is a noninvasive measurement of the autonomic regulation of the heart rate, which is quick and easy to measure with modern telemetric technology. Objective: Since HRV is affected by changes in the autonomic nervous system, it might be an early stage indicator of poor recovery from a previous bout of exercise or overreaching or overtraining in horses in general. Methods: The aim of the study was to monitor recovery an...
Cousillas H, Oger M, Rochais C, Pettoello C, Ménoret M, Henry S, Hausberger M.Electroencephalography (EEG) that has been extensively studied in humans presents also a large interest for studies on animal brain processes. However, since the quality of the recordings is altered by muscular activity, most EEG recordings on animals are obtained using invasive methods with deeply implanted electrodes. This requires anesthesia and can thus only be used in laboratory or clinical settings. As EEG is a very useful tool both for detecting brain alterations due to diseases or accidents and to evaluate the arousal and attentional state of the animal, it seemed crucial to develop a ...
Aurich C, Schneider J.In the equine species, sex determination of the conceptus is of growing interest for the breeding industry. In horses, the sex ratio of the offspring depends on changes in body condition of the mother at conception and under natural conditions may thus markedly deviate from an expected 1:1 ratio. Insemination with sex-sorted spermatozoa allows a pronounced shift of the sex ratio but at present pregnancy rates are low and vary considerably under field conditions. In equine embryo transfer programmes, sex determination in embryos before transfer via genetic methods is a promising approach with h...