Orthopedics in horses involves the study and treatment of disorders affecting the musculoskeletal system, including bones, joints, ligaments, tendons, and muscles. This field addresses a range of conditions, from developmental disorders and degenerative diseases to traumatic injuries. Common orthopedic issues in horses include fractures, osteoarthritis, tendonitis, and ligament injuries. Diagnostic techniques such as radiography, ultrasonography, and MRI are employed to assess these conditions. Treatment options may include surgical intervention, physical therapy, and pharmacological management. This page compiles peer-reviewed research studies and scholarly articles that explore the diagnosis, treatment, and management of orthopedic conditions in equine patients.
Nash RA, Nunamaker DM, Boston R.To evaluate stiffness and bone-pin interface stress for a transcortical tapered-sleeve pin (TSP) that incorporates bilateral tapered sleeves over a transcortical pin. Methods: 14 third metacarpal bones (MCIII) collected from adult horses of various breeds. Methods: Each MCIII was cut in half to provide 2 test specimens. Pins (conventional and TSP) of 3 diameters (6.35, 7.94, and 9.50 mm) were inserted in specimens (3 specimens for each diameter and each type of pin). The test fixture simulated a typical sidebar-span skeletal fixation device for horses. Single cycle load-deflection tests were p...
Watt BC, Edwards RB, Markel MD, McCabe R, Wilson DG.To compare the biomechanical characteristics and mode of failure of 2 parallel-screw techniques for proximal interphalangeal joint arthrodesis in horses. Methods: Randomized block design, blocking for horse (1-5), method of screw fixation (three 4.5-mm vs two 5.5-mm), side (left limb vs right limb), and end (front limb vs hind limb). Constructs were loaded to failure in 3-point bending in a dorsal-to-palmar (plantar) direction. Methods: Twenty limbs (10 limb pairs) from 5 equine cadavers. Methods: A combined aiming device was used to facilitate consistent screw placement. Three parallel 4.5-mm...
Rahm C, Ito K, Auer J.To compare acute fixation stability and insertion effort of cortex bone screws with and without a shaft inserted in lag fashion in equine metacarpal (metatarsal, MC(T)III) bone. Methods: Screw types with independent variables of screw diameter (4.5 or 5.5 mm) and shaft type (without shaft, with 20-mm shaft, or with 25-mm shaft) were studied. Bone specimens cut from distal equine MC(T)III condyles were used. After screw insertion in lag fashion into 2 bone blocks with an instrumented device, shear tests were conducted in a mechanical testing machine. Outcome variables of peak insertion torque, ...
Eggleston RB, Mueller PO, Chambers JN, Bentley A.Numerous techniques for surgical correction of angular limb deformities in horses involving an osteotomy of the affected bone and stabilization with an internal fixation device have been described. However, because the osteotomy typically has to be performed at the level of the physis, leaving little bone between the physis and the nearest joint, stabilizing the osteotomy by use of internal fixation devices may be difficult. In horses with severe chronic angular limb deformities, the amount of soft-tissue contracture may make it impossible to correct the deformity during a single procedure wit...
Morisset S, McClure SR, Hillberry BM, Fisher KE.To compare the in vitro holding power and associated microstructural damage of 2 large-animal centrally threaded positive-profile transfixation pins in the diaphysis of the equine third metacarpal bone. Methods: 25 pairs of adult equine cadaver metacarpal bones. Methods: Centrally threaded positive-profile transfixation pins of 2 different designs (ie, self-drilling, self-tapping [SDST] vs nonself-drilling, nonself-tapping [NDNT] transfixation pins) were inserted into the middiaphysis of adult equine metacarpal bones. Temperature of the hardware was measured during each step of insertion with ...
Ohta M, Oku K, Yamanaka T, Mizuno Y.Eighty-five thoroughbred racehorses with various types of fracture were subjected to arthroscopic surgery (44 horses) or internal fixation (41 horses) under sevoflurane anesthesia. The mean end-tidal sevoflurane concentration during anesthesia ranged from 2.5 to 2.8%. PaCO2 was maintained between 50 and 65 mmHg by controlled ventilation. The mean arterial blood pressure was maintained above 65 mmHg by infusion of dobutamine and fluids, however, heart rate significantly increased with time. Recovery from anesthesia was calm and smooth in almost all cases. No apparent complication was observed d...
Long CD, Galuppo LD, Waters NK, Hornof WJ.The aim of this study was to evaluate the diagnostic value of 99mTc-HMPAO leukocyte scintigraphy (LS) by means of a retrospective review of its use in 14 horses that were evaluated for orthopedic infection as a cause of lameness. A total of 17 LS exams were performed in 14 horses. LS studies were positive in 10 of 14 horses. A bacterial infection was confirmed with cytology or culture in 9 of 10 positive horses. Negative LS studies occurred in 4 of 14 horses. Necropsy confirmed the lack of infection in 2 of the 4 horses. Other clinical data and a favorable clinical outcome supported a negative...
Woodie JB, Ruggles AJ, Litsky AS.To evaluate 2 methods of midbody proximal sesamoid bone repair--fixation by a screw placed in lag fashion and circumferential wire fixation--by comparing yield load and the adjacent soft-tissue strain during monotonic loading. Methods: Experimental study. Methods: 10 paired equine cadaver forelimbs from race-trained horses. Methods: A transverse midbody osteotomy of the medial proximal sesamoid bone (PSB) was created. The osteotomy was repaired with a 4.5-mm cortex bone screw placed in lag fashion or a 1.25-mm circumferential wire. The limbs were instrumented with differential variable relucta...
McD○ LA, Stover SM, Taylor KT.To determine cyclic biomechanical properties of gap osteotomized adult equine tibiae stabilized with an equine interlocking nail (EIN). Methods: In vitro experimental biomechanical investigation. Methods: Thirteen adult equine cadaveric tibiae. Methods: Adult equine tibiae with transverse, midshaft, 1-cm gap osteotomies, stabilized with an equine interlocking nail, underwent cyclic biomechanical testing in vitro under axial compression, 4-point bending, and torsion. Different specimens were subjected to different load levels that represented estimated in vivo loads at 2 Hz for 740,000 cycles. ...
McD○ LA, Stover SM, Bach JM, Taylor KT.To determine the mechanical properties of Equine Interlocking Nail (EIN; JD Wheat Veterinary Orthopedic Research Laboratory, University of California, Davis) stabilized osteotomized tibiae and compare these variables with estimated in vivo loads. Methods: In vitro biomechanical investigation. Methods: Twelve adult equine cadaveric tibiae. Methods: EIN-stabilized tibiae were tested monotonically under compression, 3- and 4-point bending, and torsion. Mechanical properties were compared with estimated in vivo loads. Results: EIN-tibial composite mean compressive yield load (11 kN) and bending mo...
Ehrlich PJ, Dohoo IR, O'Callaghan MW.To document anatomic patterns of scintigraphic uptake and related orthopedic disease associated with racing activity in Standardbred horses. Methods: Retrospective study. Methods: 64 Standardbred horses evaluated for lameness. Methods: Medical records at the time of discharge were reviewed, and information regarding signalment; history; results of lameness examination, scintigraphy, and radiography; diagnosis; and treatment were obtained. Results: 274 areas of increased radiopharmaceutical uptake were identified. Scintigrams of 218 limbs (106 forelimbs, 112 hind limbs) were available for revie...
Peham C, Licka T, Girtler D, Scheidl M.The aim of this study was to compare supporting forelimb lameness determined by a motion analysis system with the subjective grading of a trained equine orthopaedic surgeon. Trotting on a treadmill, 29 individuals with a supporting forelimb lameness were measured with the SELSPOT II system and judged by the clinician. The vertical motion of the head was measured, analysed using Fourier transform, and the percentages of symmetry determined. The veterinarian evaluated the lameness and graded it according to a clinical routine. Veterinarian and system for motion analysis assigned the lameness to ...
Lopez MJ, Wilson DG, Vanderby R, Markel MD.To compare the mechanical properties of two stabilization methods for ostectomized equine third metacarpi (MC3): (1) an interlocking nail system and (2) two dynamic compression plates. Animal or Sample Population-Ten pairs of adult equine forelimbs intact from the midradius distally. Methods: Ten pairs of equine MC3 were divided into two test groups (five pairs each): caudocranial four-point bending and torsion. Interlocking nails (6 hole, 13-mm diameter, 230-mm length) were placed in one randomly selected bone from each pair. Two dynamic compression plates one dorsally (12 hole, 4.5-mm broad)...
Frisbie DD, Trotter GW, Powers BE, Rodkey WG, Steadman JR, Howard RD, Park RD, McIlwraith CW.To evaluate the effect of arthroscopic subchondral bone microfracture on healing of large chondral defects in horses. Methods: Short- (4 months) and long-term (12 months) in vivo experimental chondral defect model. Methods: 10 horses, aged 2 to 5 years. Methods: Each horse had a 1 cm2 full-thickness chondral defect created in both radial carpal bones and both medial femoral condyles. One carpus and one femoral condyle of each horse had the subchondral bone plate under the defect perforated using an orthopedic awl. All horses were exercised, five horses were evaluated after 4 months and five ho...
Black A, Schoknecht PA, Ralston SL, Shapses SA.Biochemical markers of bone turnover provide sensitive, rapid, and noninvasive monitoring of bone resorption and formation. Serum concentrations of osteocalcin (OC) reflect rates of bone formation, and urinary concentrations of the pyridinium crosslinks pyridinoline (Pyd) and deoxypyridinoline (Dpd) are specific and sensitive markers of bone resorption. These markers are age-dependent and are used to detect and monitor changes in the rates of bone turnover in a variety of orthopedic diseases in humans and may prove to have similar application in horses. This study examined age differences and ...
Willemen MA, Savelberg HH, Barneveld A.This study quantifies both the intended effect of orthopaedic shoeing to decrease the load on the navicular bone and the eventual undesired effects on gait performance. The compressive force exerted by the deep digital flexor tendon on the navicular bone and on the quality of the trot and redistribution of forces over the flexor tendons and the suspensory ligament were studied as a function of orthopaedic shoeing in 12 sound Dutch Warmblood horses. A modified CODA-3 gait analysis system and a force plate were used to quantify objectively the load on the lower limb. The quality of the trot was ...
Colgan SA, Hecker AT, Kirker-Head CA, Hayes WC.To determine risk of failure of the Synthes 4.5-mm cannulated screw system instrumentation in equine bone and to compare its application with the Synthes 4.5-mm standard cortex screw system. Methods: The maximum insertion torque of the cannulated and standard cortex screw systems were compared with the ultimate torsional strengths of the equipment. Pullout strength and ultimate tensile load of cannulated and standard cortex screws were also determined. Methods: Paired equine cadaver third metacarpal and third carpal bones. Methods: Maximum insertion torque and ultimate torsional strengths were...
Ehrlich PJ, Seeherman HJ, O'Callaghan MW, Dohoo IR, Brimacombe M.To determine anatomic patterns and clinical importance of increased radiopharmaceutical uptake in bones of horses used for show jumping, hunting, and eventing. Methods: Retrospective study. Methods: 141 horses evaluated because of lameness. Methods: Medical records were reviewed, and information on results of physical examination, radiography, and scintigraphy were obtained. Scintigrams were evaluated to identify areas of increased radio-pharmaceutical uptake. Results: 834 areas of increased radiopharmaceutical uptake were identified. Scintigraphy of the vertebral column was performed in 78 ho...
Schneider RK, Ratzlaff MC, White KK, Hopper SA.To determine effect of 3 half-limb casts on bone strains recorded from the proximal phalanx (P-1) and third metacarpal bone (MCIII) of equine cadaver limbs, using a mechanical testing machine. Methods: 12 equine cadaver limbs and 4 live horses. Methods: Bone strains were recorded at middorsal P-1 and the dorsal cortical aspect of the distal third of MCIII while limbs were variably loaded with 100 to 1,000 lb of force. To determine ability of the cast to protect the distal portion of the limb from weight-bearing loads, strains were recorded with the limb in 1 of the 3 casts and with it unsuppor...
Pearce SG, Firth EC, Grace ND, Fennessy PF.The effect of copper status on the evidence of bone and cartilage lesions was investigated in 21 Thoroughbred foals. The foals and their dams were grazed on pasture containing 4.4-8.6 mg Cu/kg dry matter (DM). Four treatment groups were created by randomly allocating mares and their foals to either copper supplemented (0.5 mg Cu/kg liveweight (LW)/day), or control (pasture only) groups. This experimental design allowed the effect of copper supplementation of mare and foal to be examined independently. Parameters of bone and cartilage development were assessed in the foals both in vivo, and at ...
Sedrish SA, Moore RM, Kelly K, Martin GS, Burba DJ.To determine and compare the in vitro pullout strength of 5.5-mm cortical versus 6.5-mm cancellous bone screws inserted in the diaphysis and metaphysis of adult equine third metacarpal (MCIII) bones, in threaded 4.5-mm cortical bone screw insertion holes that were then overdrilled with a 4.5-mm drill bit to provide information relevant to the selection of a replacement screw if a 4.5-mm cortical screw is stripped. Methods: In vitro pullout tests of 5.5-mm cortical and 6.5-mm cancellous screws in equine MCIII bones. Methods: Two independent cadaver studies each consisting of 14 adult equine MCI...
Becker CK, Savelberg HH, Buchner HH, Barneveld A.To evaluate clinical and biomechanical consequences of desmotomy of the accessory ligament (AL) of the deep digital flexor tendon (DDFT) of equine forelimbs and determine whether this procedure is a viable treatment for chronic desmitis of the AL-DDFT. Methods: 6 adult Standardbred trotters. Methods: Biomechanical recordings obtained before and 6 months after desmotomy were compared. Walk and trot joint angles, ground reaction forces, peak joint moments, and tendon forces were assessed. Results: Within 10 days after surgery, all horses were sound at a trot. Swelling, increased carpal flexion i...
Hopper SA, Schneider RK, Ratzlaff MH, White KK, Johnson CH.To determine the ability of a full-limb transfixation pin cast to protect the distal portion of the equine forelimb from weight-bearing forces by measuring bone strain in vitro on cadaver limbs loaded in a mechanical testing machine. Methods: 6 forelimbs from 6 horses. Methods: Each limb was instrumented with 3 unidirectional metal foil electrical resistant strain gauges. Gauges were placed on the dorsal aspect of the distal portion of the radius and the mid-dorsal portion of the cortex of the third metacarpal bone and the first phalanx. Each limb was tested 3 times, once supported with a tran...
Frankel HL, Haskell R, Digiacomo JC, Rotondo M.A 3-year chart survey and questionnaire was conducted of equestrian-injured patients at a regional trauma center to determine patterns and consequences of injury and rate of recidivism. Ninety-two patients (95 encounters) were treated; most were young (mean age, 27 +/- 11 years) women (84%) riders sustaining falls (80%). Most injuries were orthopedic (47%); 19 per cent of patients required hospital admission. There was one death. Helmet use was documented in only 34 per cent. Eighty-one per cent of patients responded to a follow-up telephone survey; 36 per cent recounted additional accidents (...
Murray RC, Gaughan EM, Debowes RM, Hoskinson JJ.To assess feasibility of insertion of 4.5-mm Herbert cannulated bone screws (HS) using fluoroscopic guidance and compare the mechanical shear strength of these HS and 4.5-mm AO cortical bone screws (AO) for fixation of dorsal plane slab osteotomies in equine cadaver third carpal bones (C3). Methods: Eight equine cadavers. Methods: Bone mineral composition and density of contralateral C3 were confirmed to be equivalent using dual-energy x-ray absorptiometry. A standard 10-mm C3 slab osteotomy was reduced using HS or AO instrumentation under fluoroscopic guidance. Specimens were loaded in shear ...
Hogan PM, McIlwraith CW, Honnas CM, Watkins JP, Bramlage LR.Subchondral cystic lesions (SCLs) in the condyle of the third metacarpal bone (MCIII) were surgically treated in 15 horses. The median age at presentation was 18 months (range 10 months-12 years) with 10 of 15 horses less than age 2 years. The SCLs were confined to the front limbs in all cases with 2 horses having bilateral lesions. Lesions were isolated to the medial condyle(s) of MCIII in 13 of 15 horses; a cystic lesion occurred in the lateral condyle in one horse and in the sagittal ridge in one horse. One horse with bilateral lesions had an additional cystic lesion located in the right me...
Caudron I, Miesen M, Grulke S, Vanschepdael P, Leroy P, Serteyn D.The authors used a new radiological method to assess asymmetrical articular compression of the interphalangeal joints. This method was based on the measurements of 3 angles obtained on dorsopalmar radiographs. Variations of these angles were studied during experimental asymmetrical bearing on unshod feet. It was concluded that 2 angles were interesting parameters to assess asymmetrical articular compression and to define the position of the phalanx in the horny box. Furthermore, variations of these angles induced by experimental asymmetrical bearing were compared without shoe, with a standard ...
van Zadelhoff C, Ehrle A, Merle R, Jahn W, Lischer C.Scintigraphy is a standard diagnostic method for evaluating horses with back pain due to suspected thoracic processus spinosus pathology. Lesion detection is based on subjective or semi-quantitative assessments of increased uptake. This retrospective, analytical study is aimed to compare semi-quantitative and subjective methods in the evaluation of scintigraphic images of the processi spinosi in the equine thoracic spine. Scintigraphic images of 20 Warmblood horses, presented for assessment of orthopedic conditions between 2014 and 2016, were included in the study. Randomized, blinded image ev...
Dubuc J, Da Silveira EA.A 3-week old Hanoverian foal was presented with bilateral moderate to severe carpal valgus. The deviations were 10 and 14 degrees, respectively for the left and right carpi and orthogonal radiographs of both front limbs highlighted bilateral persistent ulnar remnants. A partial resection of the ulnar remnants and periosteal transection on the disto-lateral aspect of the radius were performed bilaterally under general anesthesia. The valgus deviations began to improve within the first month and the limbs were almost straight (2 degrees for the left and right carpi) 5 1/2 months after surgery. T...
Strömberg B.Thermography in veterinary medicine has hitherto been proven to be a method of great value in the detection of orthopaedic lesions in racehorses. Lesions of the musculo-skeletal system affecting tendons, joints, bones and skeletal muscle can be demonstrated and documented at an early stage thereby preventing the development of more serious lesions.
Long CD, Galuppo LD, Waters NK, Hornof WJ.The aim of this study was to evaluate the diagnostic value of 99mTc-HMPAO leukocyte scintigraphy (LS) by means of a retrospective review of its use in 14 horses that were evaluated for orthopedic infection as a cause of lameness. A total of 17 LS exams were performed in 14 horses. LS studies were positive in 10 of 14 horses. A bacterial infection was confirmed with cytology or culture in 9 of 10 positive horses. Negative LS studies occurred in 4 of 14 horses. Necropsy confirmed the lack of infection in 2 of the 4 horses. Other clinical data and a favorable clinical outcome supported a negative...
Edwards GB, Jones DG.The use of a thermoplastic linear polyester polymer orthopaedic tape in the treatment of six horses, one donkey and a bull with a variety of orthopaedic problems requiring immobilisation of a limb is described.
Senior JM, Pinchbeck GL, Dugdale AH, Clegg PD.The records of 496 orthopaedic operations on 428 horses were reviewed to estimate the prevalence of, and identify the risk factors for, the development of colic in horses after surgery. Colic was defined as any recognised sign of abdominal pain that could not be attributed to a concurrent disease. Fourteen of the horses developed colic; eight of them were undiagnosed, three were classified as impactions, one as tympanic colic of the colon, one as incarceration of the small intestine in the epiploic foramen, and one as left dorsal displacement of the colon in the nephrosplenic space. Morphine w...
Caudron I, Miesen M, Grulke S, Vanschepdael P, Leroy P, Serteyn D.The authors used a new radiological method to assess asymmetrical articular compression of the interphalangeal joints. This method was based on the measurements of 3 angles obtained on dorsopalmar radiographs. Variations of these angles were studied during experimental asymmetrical bearing on unshod feet. It was concluded that 2 angles were interesting parameters to assess asymmetrical articular compression and to define the position of the phalanx in the horny box. Furthermore, variations of these angles induced by experimental asymmetrical bearing were compared without shoe, with a standard ...
Granello ME, Weatherall KM, Lutter JD, Beard WL. The aim of this study was to compare the deflection distance, deflection angle and pre-loading sub-bandage pressure of a transverse, mid-metacarpal fracture in an equine cadaver limb when loaded in bending while stabilized with either a Robert Jones Bandage (RJB) or a single-stack bandage (SS), each containing two orthogonal splints. Methods: In an ex vivo experimental study, forelimb pairs from eight horses were collected, and one forelimb from each pair was assigned to either the SS or RJB groups. A transverse osteotomy was performed at the midpoint of the metacarpus. After bandaging, ...
Nash RA, Nunamaker DM, Boston R.To evaluate stiffness and bone-pin interface stress for a transcortical tapered-sleeve pin (TSP) that incorporates bilateral tapered sleeves over a transcortical pin. Methods: 14 third metacarpal bones (MCIII) collected from adult horses of various breeds. Methods: Each MCIII was cut in half to provide 2 test specimens. Pins (conventional and TSP) of 3 diameters (6.35, 7.94, and 9.50 mm) were inserted in specimens (3 specimens for each diameter and each type of pin). The test fixture simulated a typical sidebar-span skeletal fixation device for horses. Single cycle load-deflection tests were p...
Baller LS, Hendrickson DA.Pain management is an extremely vital part of equine orthopedic surgery. Providing optimum analgesia for the patient will decrease recovery time, decrease physiologic stress on the animal, and provide maximum comfort during the post-operative period. The major analgesic drug categories and routes covered are nonsteroidal anti-inflammatory drugs, local anesthetics, intra-articular drugs, and epidurals.
Hodgson DS, Dunlop CI.We have discussed anesthetic techniques, special considerations, and expected complications involved in anesthetizing horses for abdominal, orthopedic, and head and neck surgery, and myelography and have described expected physiologic dysfunction that may require changes in anesthetic technique or supportive measures. The objective is high-quality patient care and reduction in anesthesia-related morbidity and death.
Gillis JP, Zardiackas LD, Gilbert JA, St John KR.Paired equine third metacarpal bones were drilled and tapped for 4.5 mm and 5.5 mm cortical screws. Tapping was done by hand or with an air-driven reversible orthopedic drill. Screws were inserted and subjected to extraction forces to failure of the osseous threads or the screws. There was no difference in holding power of either screw size between hand-tapped and power-tapped holes.
Martin BB, Reef VB.The successful conservative treatment of an open, displaced fracture of the radius of a horse suggests that conservative treatment should not be ignored when surgery is not an option. The importance of proper soft-tissue management and the use of broad-spectrum antimicrobial treatment in the management of orthopedic injuries is emphasized.
Barton CK, Goodrich LR.The use of radiofrequency energy (RFE) has become increasingly popular in equine orthopedic surgery in recent years, particularly for the debridement of cartilage lesions and soft tissue resection. However, despite considerable advancements in the technology, the safety and efficacy of RFE have continued to be questioned. While studies investigating the use of RFE for chondroplasty in the equine population are lacking, there is an abundance of research studies in the human literature assessing its effect on healthy chondrocytes, and researchers are seeking to develop guidelines to minimize col...
Kidd JA, Lamas L, Henson FM.To report repair of a longitudinal scapular fracture in a horse. Methods: Case report. Methods: A 2-year-old Paint Horse colt. Methods: A longitudinal scapular fracture was surgically repaired using four 4.5 mm dynamic compression plates. Results: An acute longitudinal scapular fracture repaired surgically returned the horse to soundness within 6 months. Conclusions: Internal fixation of longitudinal scapular fracture is possible with multiple 3-5 hole dynamic compression plates. Conclusions: Longitudinal fractures of the scapula should be considered when there is lateral instability of the sh...
Lopez MJ, Wilson DG, Vanderby R, Markel MD.To compare the mechanical properties of two stabilization methods for ostectomized equine third metacarpi (MC3): (1) an interlocking nail system and (2) two dynamic compression plates. Animal or Sample Population-Ten pairs of adult equine forelimbs intact from the midradius distally. Methods: Ten pairs of equine MC3 were divided into two test groups (five pairs each): caudocranial four-point bending and torsion. Interlocking nails (6 hole, 13-mm diameter, 230-mm length) were placed in one randomly selected bone from each pair. Two dynamic compression plates one dorsally (12 hole, 4.5-mm broad)...
Kneipp MLA, Sousa LN, Cota LO, Malacarne BD, Winter IC, Santana CH, Santos RL, Xavier ABS, Faleiros RR, Carvalho AM.Coxofemoral dysplasia is a condition characterized by the abnormal development and flattening of the femoral head and deformities in the acetabulum, leading to joint instability. Although described in various animal species, it is uncommon and rarely reported in horses. This article presents a case of incapacitating coxofemoral dysplasia diagnosed in a four-month-old foal Mangalarga Marchador, which exhibited lameness in the hind limbs, thoracolumbar kyphosis, gluteal muscle atrophy, and pronounced sensitivity during pelvic limb flexion. The clinical diagnosis indicative of bilateral coxofemor...
Ellis KL, Giancola S.Rehabilitation for tendon/ligament injury requires a multimodal approach to reduce pain, restore range of motion, improve proprioception/neuromotor control, and improve strength/endurance. Multiple tools are available to accomplish these goals. The rehabilitation program must be tailored to the individual patient regardless of injury type in order to return the horse to full athletic activity and reduce the risk of reinjury.
McD○ LA, Stover SM, Bach JM, Taylor KT.To determine the mechanical properties of Equine Interlocking Nail (EIN; JD Wheat Veterinary Orthopedic Research Laboratory, University of California, Davis) stabilized osteotomized tibiae and compare these variables with estimated in vivo loads. Methods: In vitro biomechanical investigation. Methods: Twelve adult equine cadaveric tibiae. Methods: EIN-stabilized tibiae were tested monotonically under compression, 3- and 4-point bending, and torsion. Mechanical properties were compared with estimated in vivo loads. Results: EIN-tibial composite mean compressive yield load (11 kN) and bending mo...
Horne CR, Redding WR.The location of a suspensory ligament (SL) injury heavily influences the clinical presentation, prognosis, and treatment options. Diagnostic imaging is necessary to provide an accurate diagnosis and is critical to ensure the institution of the most appropriate treatment. The hindlimb proximal SL in particular can be challenging to diagnosis, carries a guarded prognosis, and typically requires aggressive treatment to achieve soundness.
Smith RKW, Schramme MC.Superficial digital flexor tendinopathy is one of the most common orthopedic soft tissue injuries in horses. The veterinary challenge for this condition is less related to identifying the presence of the injury (as it is usually readily evident clinically) but more related to improving the healing process so that the healed tendon is more like normal tendon in biology and function in order to reduce reinjury, which is the key adverse consequence of the injury. Diagnostic imaging has improved in recent years to aid with treatment choices and monitoring the healing process.
Dersch K, Kreuder A, Wang C, Troy J.Surgical site infections (SSI) are a common postoperative complication of equine orthopedic surgery and often increase morbidity and mortality. Objective: This study aimed to determine if covering surgical instruments during surgery decreased bacterial environmental air contamination during early opening of surgical packs (EOSP). The authors hypothesized that covering instruments with sterile surgical towels would reduce the total number of bacterial colonies to which the instruments were exposed. Methods: Blood agar plates (BAP) were allocated into two groups (non-covered vs. covered with a s...
Keller LE, Kelly TN, Chevalier JM, Jung HJ, Pearson GB, Begum L, Beane OS, Bhumiratana S, Fortier LA.Fresh osteochondral allograft (OCA) transplantation effectively repairs cartilage and subchondral bone; however, the persisting shortage of available donor OCAs and their short shelf-life make scheduling surgeries and meeting patient demand challenging. Attempts have been made to develop tissue-engineered solutions to address the limitations of OCA; nonetheless, these have failed to progress beyond the preclinical stage. Objective: To assess the safety and efficacy of a tissue-engineered osteochondral allograft (TE-OCA) as compared with equine OCA in an equine osteochondral defect model. Metho...
Ehrlich PJ, Dohoo IR, O'Callaghan MW.To document anatomic patterns of scintigraphic uptake and related orthopedic disease associated with racing activity in Standardbred horses. Methods: Retrospective study. Methods: 64 Standardbred horses evaluated for lameness. Methods: Medical records at the time of discharge were reviewed, and information regarding signalment; history; results of lameness examination, scintigraphy, and radiography; diagnosis; and treatment were obtained. Results: 274 areas of increased radiopharmaceutical uptake were identified. Scintigrams of 218 limbs (106 forelimbs, 112 hind limbs) were available for revie...
Bueno AC, Galuppo LD, Taylor KT, Jensen DG, Stover SM.To compare the mechanical shear strengths and stiffnesses obtained from in vitro testing of a simulated complete third carpal bone (C3) frontal plane radial facet slab fracture (osteotomy) stabilized with either a 4/5 Acutrak (AT) compression screw or a 4.5-mm AO cortical bone (AO) screw inserted in lag fashion. Drilling, tapping, and screw insertion torques, forces, and times also were compared between AT and AO implants. Methods: In vitro biomechanical assessment of site preparation, screw insertion, and shear failure test variables of bone screw stabilized simulated C3 slab fracture in pair...
Quinteros DD, García-López JM, Abuja GA, Tarkanian M, Maranda LS, Bubeck K, Kowaleski MP.To determine if the mechanical properties (strength and stiffness) of a new prototype 4.5 mm broad locking plate (NP-LP) are comparable with those of a traditional 4.5 mm broad limited-contact self compression plate (LC-SCP), and to compare the bending and torsional properties of the NP-LP and LC-SCP when used in osteotomized equine third metacarpal bones (MC3). Methods: The plates alone were tested in four-point bending single cycle to failure. The MC3-plate constructs were created with mid-diaphyseal osteotomies with a 1 cm gap. Constructs were tested in four-point bending single cycle to fa...
Rahm C, Ito K, Auer J.To compare acute fixation stability and insertion effort of cortex bone screws with and without a shaft inserted in lag fashion in equine metacarpal (metatarsal, MC(T)III) bone. Methods: Screw types with independent variables of screw diameter (4.5 or 5.5 mm) and shaft type (without shaft, with 20-mm shaft, or with 25-mm shaft) were studied. Bone specimens cut from distal equine MC(T)III condyles were used. After screw insertion in lag fashion into 2 bone blocks with an instrumented device, shear tests were conducted in a mechanical testing machine. Outcome variables of peak insertion torque, ...
Tyrnenopoulou PC, Rizos ED, Kritsepi-Konstantinou M, Papadopoulou PL, Patsikas MN, Papazoglou LG, Aggeli A, Diakakis NE.To determine whether differences existed in the viscoelastic properties of synovial fluid samples from the metacarpophalangeal, intercarpal, and distal interphalangeal joints of orthopedically normal athletic horses. Methods: 45 warmblood horses and 30 Thoroughbreds (age range, 4 to 16 years). Methods: Synovial fluid samples were aseptically obtained via arthrocentesis from 1 metacarpophalangeal, intercarpal, and distal interphalangeal joint of each horse, and nucleated cell counts were performed. A commercial ELISA was used to measure sample hyaluronic acid concentrations, and full rheologica...
Sod GA, Riggs LM, Mitchell CF, Martin GS, Gill MS.To compare number of cycles to failure for palmarodorsal 4-point bending of a modified 5.5 mm broad locking compression plate (M5.5-LCP) fixation with a 5.5 mm broad LCP (5.5-LCP) fixation used to repair osteotomized equine third metacarpal (MC3) bones. Methods: In vitro biomechanical testing. Methods: Adult equine cadaveric MC3 bones (n=6 pairs). Methods: An 8-hole, M5.5-LCP, obtained by having a 1.0 mm thickness removed from the bone contact portion of the 5.5-LCP, was applied to the dorsal surface of 1 randomly selected MC3 from each pair, and an 8-hole, 5.5-LCP was applied dorsally to the ...
Sherlock CE, Eggleston RB, Howerth EW.A 7-year-old Quarter Horse gelding was evaluated because of sudden onset of severe left forelimb lameness of 4 days' duration. Results: Clinical evaluation and diagnostic perineural analgesia localized the lameness to the distal portion of the left forelimb. Radiography revealed a transverse fracture of the distal phalanx of the left forelimb. Results: The horse was treated conservatively with stall rest and stabilization of the hoof with fiberglass cast material and an elevated heel support. These treatments improved the lameness considerably. Over the following 4 months, the horse was exerci...