The integration of technology in equine management encompasses a range of tools and systems designed to enhance the care, training, and monitoring of horses. This includes wearable devices that track vital signs and activity levels, providing data for health assessments and performance optimization. Advanced imaging techniques, such as thermography and ultrasonography, aid in the diagnosis and treatment of equine injuries and conditions. Additionally, developments in genetic testing contribute to understanding hereditary traits and potential health risks. This page gathers peer-reviewed research studies and scholarly articles that explore the application, effectiveness, and impact of technology in various aspects of equine care and management.
Jeffcott LB, Holmes MA, Townsend HG.Back pain is a common and poorly understood clinical problem. An important factor in this regard is the induction or exacerbation of back pain from badly designed or poorly fitting saddles. This study used a pressure-sensing mat to investigate saddle fit. The aims of the study were to confirm the accuracy and reliability of the force-sensing array technology when used to measure pressure beneath the saddles of horses, and to collect some initial data from normal healthy horses with well-fitting saddles. Experiments were undertaken to establish that a linear relationship existed between the tot...
Voigt G.The author informs on up to date identification methods of horses. The implantation of passive transponders is a practicable method for marking of horses. Because it gives less pain to horses, this method is to prefer. Stress inflicted on horse is minimal, it compares to a intramuscular injection. The reliability of the system in use has so far been very high. Members of ISO have voted overwhelmingly in favor of a standard for electronic identification of animals. From now on, countries and user organizations can make use of this technique to identify animals and if used can rely on the fact t...
Weigand K, Gerhards H, Köstlin R.The transmission of the laser beam trough flexible fibers enables an endoscopic application. Since this technique is minimal invasive and often does not require general anaesthesia there is an increasing interest in the use of laser techniques-for example in equine upper respiratory tract surgery. This paper gives a review about reported laser application in the different fields of veterinary surgery with emphasis on laser practice in dermatology, ophthalmology and endoscopic laser application.
Tietje S, Becker M, Böckenhoff G.The rapid development of software and technology now allows a large amount of diagnostic information to be obtained from a computed tomographic examination. This imaging technique can also be usefully applied to the horse, given appropriate premises and a custom built table for accurate positioning. Computed tomography of the skull has considerable advantages over other techniques, as structures are viewed without superimposition. Fifteen cases are used to demonstrate how through high image quality (precise detail, reduction in artefacts) and objective measurement of density, various pathologi...
Linford RL.Quantitated locomotion analysis is increasingly being used during assessment and treatment of gait disorders in human beings. Locomotion analysis is also thought to have potential for enhancing the assessment of lameness in horses. Availability of high-speed video recording systems has simplified the process of quantitated locomotion analysis; however, the high cost of such systems has limited their use for routine clinical assessment in horses. The temporal resolution of 500- to 1,000-images/s (Hz) recording systems is beyond what has been considered necessary for precise quantitation of shor...
Koblik PD, Freeman DM.Current clinical magnetic resonance (MR) imaging studies provide almost no useful signal from normal tendon and have no clear advantage over other imaging modalities in the evaluation of tendon injuries. The authors believe that tendon MR signal may be T2-limited, and, if so, could be enhanced by short echo time (TE) pulse sequences. The relationship of tendon signal intensity and tendon infrastructure conspicuity to TE was assessed at three different field strengths. Methods: Magnetic resonance imaging studies were performed on samples of normal equine tendon at 3 different field strengths wi...
Pilsworth RC, Holmes MA, Shepherd M.A fracture of the pelvis in a horse can be detected scintigraphically by probe point counting. However, the pelvis is covered by a large and variable muscle mass, and is close to the urinary bladder, both of which can introduce errors. This paper describes an improved technique which uses a larger set of sampling points and analyses the data with a small computer to construct a three dimensional graph of the gamma-ray output across the pelvis, thus helping to improve the interpretation of the data. The scintigraphic plot from a normal horse, three cases of fracture (confirmed by radiography, u...
Roepstorff L, Drevemo S.To further develop objective methods in the field of gait analysis a force-measuring horseshoe (FM shoe) has been developed. The ground reaction forces were determined by measuring the degree of displacement between the two solid parts of the shoe. This was done by three removable measuring units (MUs) that were equipped with strain gauges and placed in the toe and in each of the quarter parts. Before performing force recordings the sensors were calibrated with the actual MUs mounted on the shoe. This can be done in the field with a specially developed equipment. The shape of the signal genera...
O'Callaghan MW.We live in an age in which highly sophisticated computerized equipment and imaging methods are becoming increasingly available. Demand from clients requires that we as veterinary professionals keep our eyes on the future potential of these technologies for diagnosis and treatment. This article briefly reviews some of the techniques that are just around the corner for the progressive equine practitioner.
Reef VB.A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be ...
Williams RB, Clark CG, Young SS.A technique for continuous computerised recording and analysis of the stride of horses on a treadmill is described. Advantages of the system are low cost, the use of normal shoes and the calculation of stride parameters in real time.
Schneider C, Müller FP, Bertschi I.We describe the utilization of the Abbott Vision system in a horse clinic and a comparison with the Compur M 2000 CS (Bayer Diagnostics and Electronics). Discrepancies were found in respect to precision and accuracy of results. Both systems showed good practicability during routine operation but different cost-effectiveness.
de Waal A, Potgieter FJ.Dehydration, to varying degrees, will inevitably occur in horses participating in endurance trail rides. This water loss is directly related to the amount of body water lost through evaporative cooling, that in turn being related to the amount and rate of work performed, and to the environmental temperature and humidity. An electronic apparatus that can substitute for the conventional and time-consuming venous haematocrit was developed to measure the animals' hydration status. The mechanism of this electrometer is based upon the relationship between the red cell content and the electrical cond...
Hartley JW, Hahn AW, DeLorey M, Caldwell WM.We have developed and used a system for recording and analyzing the electrocardiogram (ECG) of the horse during exercise. The system consists of a commercial ECG transmitter telemetering a Z lead (base-apex) ECG from an exercising horse. The received data are then remodulated at an audio frequency and stored on a audio cassette recorder. Exercise protocols of up to 10 minutes are digitized using a Macintosh II computer. For rhythm analysis, a computer program to identify the various waves of the ECG uses a modification and refinement of the integrated-squared-derivative (ISD) technique. This t...
Morris DD.THERE are indications for therapeutic uses of all portions of
whole blood in large animal patients but plasma and its isolated components have the largest number of immediate
applications. As recently as 10 years ago, whole fresh blood
was the only routinely administered blood product. However,
as even cross-match compatible erythrocytes are removed
from circulation within two to four days by the reticuloendothelial system, whole blood is a poor product for expansion of
vascular volume or supplying plasma components if the
patient has no immediate need for increased oxygen carrying
cap...
Hoshino Y, Gorziglia M, Valdesuso J, Askaa J, Glass RI, Kapikian AZ.An equinine rotavirus FI-14 strain, originally isolated from a diarrheic foal in New York state, was shown to belong to serotype 3 by neutralization assay. In addition, it was found to react with both subgroup I and subgroup II monoclonal antibodies by enzyme-linked immunosorbent assay (ELISA), thus representing the first rotavirus strain to exhibit both subgroup specificities. By using hybridoma technology, we successfully produced monoclonal antibodies directed against the major inner capsid protein VP6 (the sixth gene product) of FI-14 virus. Such monoclonal antibodies reacted specifically ...
Hartley JW, Hahn AW, DeLorey M, Caldwell WM.We have developed and used a system for recording and analyzing the electrocardiogram (ECG) of the horse during exercise. The system consists of a commercial ECG transmitter telemetering a Z lead (base-apex) ECG from an exercising horse. The received data are then remodulated at an audio frequency and stored on a audio cassette recorder. Exercise protocols of up to 10 minutes are digitized using a Macintosh II computer. For rhythm analysis, a computer program to identify the various waves of the ECG uses a modification and refinement of the integrated-squared-derivative (ISD) technique. This t...
Scott EA, Sandler GA.Electromagnetic blood flowmeters and flow probes are used to measure blood flow in blood vessels throughout the circulatory system. The principle of this measuring device is based on laws of electromagnetic induction discovered in the 19th century. The instrument has been predominantly used in research, but is presently used in human cardiovascular units to measure blood flow in blood vessels, and in prosthesis in conjection with cardiovascular surgical procedures. Electromagnetic flow equipment provides the most accurate measurement (in vivo) of blood flow available, both for acute and chroni...
Nguyen JS, Tran Y, Su SW, Nguyen HT.This paper is concerned with the design and development of a semi-autonomous wheelchair system using cameras in a system configuration modeled on the vision system of a horse. This new camera configuration utilizes stereoscopic vision for 3-Dimensional (3D) depth perception and mapping ahead of the wheelchair, combined with a spherical camera system for 360-degrees of monocular vision. This unique combination allows for static components of an unknown environment to be mapped and any surrounding dynamic obstacles to be detected, during real-time autonomous navigation, minimizing blind-spots an...
Schwarz J, Vidondo B, Maninchedda UE, Sprick M, Schöpfer MC, Cruz AM. To assess the inter-evaluator and intra-evaluator reliability of a software program used to extract kinematic variables by a commercially available extremity-mounted inertial measurement unit system in sound horses at the trot under soft and hard ground conditions and treadmill exercise. Thirty adult, sound and healthy French Montagne stallions. Data collection was performed with six IMUs strapped to the distal, metacarpal, metatarsal and tibial regions of every horse. Per surface (treadmill, soft and hard ground) 10 stallions were trotted three times. Prior to the analysis done by six eval...
Slusarewicz P, Slusarewicz JH, Nielsen MK.An automated equine fecal egg count test, known as the Parasight System, was modified for use with small ruminants. Modifications included the introduction of a short centrifugation step in a floatation medium, an adjustment in pre-test sample filtering, and training of an image analysis-based egg counting algorithm to recognize and enumerate trichostrongylid eggs. In preliminary assessments, the modified method produced trichostrongylid egg counts comparable to manual McMaster analyses of the same samples from both ovine and caprine sources. The coefficient of determination (R) for the linear...
Darbandi H, Serra Bragança F, van der Zwaag BJ, Voskamp J, Gmel AI, Haraldsdóttir EH, Havinga P.Speed is an essential parameter in biomechanical analysis and general locomotion research. It is possible to estimate the speed using global positioning systems (GPS) or inertial measurement units (IMUs). However, GPS requires a consistent signal connection to satellites, and errors accumulate during IMU signals integration. In an attempt to overcome these issues, we have investigated the possibility of estimating the horse speed by developing machine learning (ML) models using the signals from seven body-mounted IMUs. Since motion patterns extracted from IMU signals are different between bree...
Nath LC, Forbes G, Elliott AD, Tomren V, Ryan A, Franklin SH.AliveCor is a smartphone electrocardiography device (iECG) providing automated heart rate (HR) and rhythm determination. Atrial fibrillation (AF) in horses often is paroxysmal and rapid ECG acquisition is needed for diagnostic confirmation. iECGs were collected post-race from 15 horses with AF and 64 horses in sinus rhythm (SR). Results of manual assessment were compared to 3 commercial algorithms for HR and rhythm. Agreement between manually derived HR (HRM ) and HR derived by the AliveECG Vet (HRVET ) and Kardia version-1 (KV1 HR) and Kardia advanced (KADV HR) algorithms was quantified by th...
Corradini I, Fernández-Ruiz A, Barba M, Engel-Manchado J.Comparisons between smartphone ECG (SpECG) recordings obtained from the right and left sides of the thorax have not been reported in animals. Objective: To evaluate the screening potential of a SpECG obtained from both sides of the thorax and to compare the degree of agreement between the SpECG and a reference ECG (rECG) for measurement of the duration of baseline electrical deflections recorded over both sides of the thorax. Methods: Fifty horses admitted to the equine hospital, university-owned horses, and horses from an endurance riding facility. Methods: Prospective observational study. Si...
Dybdal N, Horgan M, Costa L, Davis E, Lucero S, Nieves S, Quiroz V, Weberg K, Madigan JE.Challenges and issues related to the use of pentobarbital euthanasia and disposal of animal remains within the US have recently been reviewed. Environmental and public health challenges increasingly necessitate consideration of alternative methods such as gunshots, an American Veterinary Medical Association (AVMA) "acceptable with conditions" method, for the humane euthanasia of horses. A recent study reported a correctly aimed gunshot provides a humane option for euthanizing horses. However, although aiming guidelines exist, studies examining bullet trajectories in animals euthanized by gunsh...
Chardonnet JR, Ryard J, Secheppet M, Benezet C, Azema G, Leblanc S.Animal welfare has become an increasingly important concern in the sports field. Learning horse-drawn carriage driving requires much time and effort for both the drivers and the horses because the associated gestures to avoid harming the horses are difficult to acquire. This raises the need to develop realistic simulation environments for future drivers. To this end, two haptic interface prototypes were designed, coupled with dedicated simulation software. The first was developed based on a SPIDAR haptic device and implemented simple behaviors of the carriage. A user study demonstrated interes...
Egan S, Brama P, McGrath D.Wearable sensing technologies are increasingly used in human and equine gait research to improve ecological validity of research findings. It is unclear how these tools have penetrated the equine industry or what perspectives industry stakeholders' hold in relation to these relatively new devices. Semi-structured interviews were conducted with Irish equine industry stakeholders to understand their perception of objective tools for biomechanical analysis in the field. The study participants came from professional/elite backgrounds in both the sport horse ( = 6) and thoroughbred ( = 6) sectors. ...
Szalay F, Back W, Barneveld A, Schamhardt H, Hajós F.A VHS video--computer-based image analysis combination is described as a low sampling rate motion analysis system. Video recordings were taken indoor without any artificial illumination at 25 fps sampling rate. The horse studied was running on a high-speed treadmill and observed at 1.6, 4 and 7 m/s velocities at walk, trot and canter, respectively. Left forelimb and hindlimb were recorded separately from lateral view. For comparison, parallel CODA-3 recordings were taken at the same time from the same position. Joint angles were expressed and compared in angle-time diagrams. Sampling of both s...
Bouhali O, Bensmail H, Sheharyar A, David F, Johnson JP.Great advances have been made in human health care in the application of radiomics and artificial intelligence (AI) in a variety of areas, ranging from hospital management and virtual assistants to remote patient monitoring and medical diagnostics and imaging. To improve accuracy and reproducibility, there has been a recent move to integrate radiomics and AI as tools to assist clinical decision making and to incorporate it into routine clinical workflows and diagnosis. Although lagging behind human medicine, the use of radiomics and AI in veterinary diagnostic imaging is becoming more frequent...
Salau J, Hildebrandt F, Czycholl I, Krieter J.Sensors delivering information on the position of farm animals have been widely used in precision livestock farming. Global Positioning System (GPS) sensors are already known from applications in military, private and commercial environments, and their application in animal science is increasing. However, as trade-offs between sensor cost, battery life and sensor weight have to be made, GPS based studies scheduling long data collection periods and including a high number of animals, have to deal with problems like high hardware costs and data disruption during recharging of sensors. Furthermor...
Pirie CG, Pizzirani S. To describe a novel digital single lens reflex (dSLR) camera adaptor for anterior and posterior segment photography. Methods: The adaptor was used to evaluate canine, feline, and equine patients presenting to Tufts Ophthalmology service. Anterior segment imaging was conducted with the adaptor mounted between a dSLR camera body (Canon 7D) and a macro lens (Canon EF-S 60mm/f2.8). Posterior segment imaging was performed with the aid of an indirect ophthalmic lens mounted in front of the macro lens. Coaxial illumination during viewing was provided by a single white light-emitting diode (LE...
Dotzel AR, Baratt RM.The use of oral endoscopy can be very beneficial in that it helps the clinician to perform a more thorough oral examination. However, due to the high cost, most commercially available equine oral endoscopy systems have been out of reach for clinicians who practice equine dentistry outside a large hospital setting. This article details how to set up an oral endoscopy system that can be used on equine patients either in an ambulatory practice or in a hospital setting. The system is more cost-effective than most other systems currently on the market without sacrificing functionality or image qual...
Schneider C, Müller FP, Bertschi I.We describe the utilization of the Abbott Vision system in a horse clinic and a comparison with the Compur M 2000 CS (Bayer Diagnostics and Electronics). Discrepancies were found in respect to precision and accuracy of results. Both systems showed good practicability during routine operation but different cost-effectiveness.
Walker N, Huseman C, Cater M, McCorkle DA, Hanselka D, Zoller J.The COVID-19 pandemic has increased the availability of virtual horse showing opportunities. The objectives of this study were to describe survey participants' personal characteristics and participation in virtual and in-person horse shows, level of satisfaction, attitude toward technology and motivation to participate, and internal and external factors influencing the decision to participate in virtual horse shows. A survey was distributed to a target audience of adult horse show participants and/or adults supporting youth horse show participants via Qualtrics (n = 251). A majority of respo...
Anderson K, Morrice-West AV, Walmsley EA, Fisher AD, Whitton RC, Hitchens PL.Musculoskeletal injuries are observed in Thoroughbred racehorses and may become catastrophic. Currently, there are limited methods for early detection of such injuries. Most injuries develop gradually due to accumulated damage, providing the opportunity for early detection. Horses experiencing pain or lameness may exhibit changes in behaviour so the development of an objective, real-time system monitoring horse behaviour may enable detection of bone injuries before catastrophic failure. Objective: To determine whether intensive observational methods of assessing horse behaviour can be replaced...
Krishnan BS, Jones LR, Elmore JA, Samiappan S, Evans KO, Pfeiffer MB, Blackwell BF, Iglay RB.Visible and thermal images acquired from drones (unoccupied aircraft systems) have substantially improved animal monitoring. Combining complementary information from both image types provides a powerful approach for automating detection and classification of multiple animal species to augment drone surveys. We compared eight image fusion methods using thermal and visible drone images combined with two supervised deep learning models, to evaluate the detection and classification of white-tailed deer (Odocoileus virginianus), domestic cow (Bos taurus), and domestic horse (Equus caballus). We cla...
Yuan C, Du J, Yue M, Ma T.The control network is an important supporting environment for the control system of the heavy ion accelerator in Lanzhou (HIRFL). It is of great importance to maintain the accelerator system's network security for the stable operation of the accelerator. With the rapid expansion of the network scale and the increasing complexity of accelerator system equipment, the security situation of the control network is becoming increasingly severe. Port scanning detection can effectively reduce the losses caused by viruses and Trojan horses. This article uses Go Concurrency Patterns, combined with tran...
Theves G.During the second half of the 18th century scientific veterinary medicine, a new profession was born as a result of economic and military needs--losses of cattle as a consequence of infectious diseases and the growing demand for treatment to be given to the horses of the armies. At first the members of the emerging occupation, who are generally of very modest origin, hardly differ from the traditional actors of animal health. At the beginning of the 19th century the governments employ a large number of veterinarians for official missions to combat infectious diseases. As from the second half o...
Matsumoto T, Okumura S, Hirata S.This study aimed to apply radar technology to a large quadruped animal. We first developed a non-contact respiration measurement system using millimeter-wave array radar for a horse in standing position. Specifically, we measured the respiration of a stationary domestic horse in stables. Simultaneously, we measured the respiration rate using infrared thermography and developed a method for analyzing the radar information while verifying the rate of agreement. Our results suggested that the radar technology detected breathing and accurately measured the respiration of a horse, despite variation...
Slusarewicz P, Pagano S, Mills C, Popa G, Chow KM, Mendenhall M, Rodgers DW, Nielsen MK.Intestinal parasites are a concern in veterinary medicine worldwide and for human health in the developing world. Infections are identified by microscopic visualisation of parasite eggs in faeces, which is time-consuming, requires technical expertise and is impractical for use on-site. For these reasons, recommendations for parasite surveillance are not widely adopted and parasite control is based on administration of rote prophylactic treatments with anthelmintic drugs. This approach is known to promote anthelmintic resistance, so there is a pronounced need for a convenient egg counting assay...
Hontoir F, Simon V, De Raeve Y, Dumortier L, Dugdale A, Vandeweerd JM.Different modalities such as lectures, dissections, 3D models, and online learning are used for teaching anatomy. To date, online learning has been considered a useful additional didactic tool. This study aimed to compare veterinary students' performance in radiographic anatomy (radio-anatomy) after online or classroom-based teaching to assess the extent to which the two methods were interchangeable. Three strategies were compared in a cohort of 83 learners. Students were committed to online learning only, online learning with the use of specimen equine bones, or learning on conventional radio...
Roepstorff L, Drevemo S.To further develop objective methods in the field of gait analysis a force-measuring horseshoe (FM shoe) has been developed. The ground reaction forces were determined by measuring the degree of displacement between the two solid parts of the shoe. This was done by three removable measuring units (MUs) that were equipped with strain gauges and placed in the toe and in each of the quarter parts. Before performing force recordings the sensors were calibrated with the actual MUs mounted on the shoe. This can be done in the field with a specially developed equipment. The shape of the signal genera...
Nelson NC, Zekas LJ, Reese DJ.As availability increases and cost decreases, digital radiograph systems become more common in equine practice. Technological advances provide an array of choices for the equine practitioner considering purchase. Two classes of systems are available: computed radiography and flat-panel systems (direct radiography). Image processing encompasses all manipulations performed on an image at acquisition and can have a profound effect on the final digital radiograph. Consideration should be given to the type of display monitor because many options are now available. The type of display monitor and th...
Gomiero C, Bertolutti G, Martinello T, Van Bruaene N, Broeckx SY, Patruno M, Spaas JH.Tendons regenerate poorly due to a dense extracellular matrix and low cellularity. Cellular therapies aim to improve tendon repair using mesenchymal stem cells and tenocytes; however, a current limitation is the low proliferative potential of tenocytes in cases of severe trauma. The purpose of this study was to develop a method useful in veterinary medicine to improve the differentiation of Peripheral Blood equine mesenchymal stem cells (PB-MSCs) into tenocytes. PB-MSCs were used to study the effects of the addition of some growth factors (GFs) as TGFβ3 (transforming growth factor), EGF2 (Epi...
Piketh G, Williams A, Schliewert EC.Electrocardiography is the method used to monitor the electrical impulses in the heart. These diagnostics are increasingly making use of smartphone-based technologies. The objective of this research was to determine whether the Alivecor KardiaMobile (ECG) smartphone-modulated electrocardiographic device, a novel ECG device, can be used to obtain reliable electrocardiogram (ECG) readings in horses. The device was initially tested in 36 Nooitgedacht pony mares to determine the best site of application, method of skin preparation, and ECG device orientation for reliable ECG tracings. Once the mos...
Sandybayev N, Strochkov V, Beloussov V, Orkara S, Kydyrmanov A, Khan Y, Batanova Z, Kassenov M.Equine influenza (EI) is a highly contagious disease that causes fever and upper respiratory tract inflammation. It is caused by influenza virus A, belonging to the family, with subtypes H3N8 and H7N7. This study presents data on the development of a real-time polymerase chain reaction (RT-PCR) assay using TaqMan probes to detect the H3 subtype of EI virus (EIV). Unassigned: The evaluation of the developed RT-PCR assay involved five strains of EIV as positive controls and ten nasopharyngeal swab samples collected from horses. RNA was isolated using the GeneJet Viral DNA and RNA Purification K...