Analyze Diet

Topic:Sampling

Sampling in equine research involves the selection and collection of data from horses to study various aspects of their health, behavior, genetics, and physiology. This process is fundamental for obtaining representative data that can be used to draw conclusions about larger equine populations. Sampling methods can include random sampling, stratified sampling, and convenience sampling, each with its specific applications and limitations. Proper sampling techniques ensure the reliability and validity of research findings. This page compiles peer-reviewed research studies and scholarly articles that explore sampling methodologies, their applications in equine studies, and their impact on research outcomes.
Evidence of Horse Exposure to Anaplasma phagocytophilum, Borrelia burgdorferi, and Leishmania infantum in Greece through the Detection of IgG Antibodies in Serum and in an Alternative Diagnostic Sample-The Saliva.
Biomolecules    September 11, 2023   Volume 13, Issue 9 doi: 10.3390/biom13091374
Athanasiou LV, Katsogiannou EG, Tyrnenopoulou P, Gougoulis D, Apostolidis KN, Papadakis SM, Kokkinaki KCG, Papatsiros VG, Tsokana CN.Among the various zoonotic pathogens that infect horses, Anaplasma phagocytophilum, Borrelia spp. and Leishmania spp. have gained scientific interest, and relevant molecular and serological studies in horses have been conducted worldwide. Moreover, human and veterinary medicine have extensively applied alternatives to serum diagnostic samples-such as saliva-for detecting pathogens or antibodies. In this study, we investigated the exposure of horses in Greece to A. phagocytophilum, B. burgdorferi, and L. infantum, and we assessed the diagnostic accuracy of saliva compared to serum in detecting ...
Discrepancies between phenotypic and genotypic identification methods of antibiotic resistant genes harboring Staphylococcusaureus.
Microbial pathogenesis    September 11, 2023   Volume 184 106342 doi: 10.1016/j.micpath.2023.106342
Rasheed H, Ijaz M, Ahmed A, Javed MU, Shah SFA, Anwaar F.Antimicrobial resistance is a global issue that limits therapeutic options for infections. S. aureus being a member of the ESKAPE group is capable of "escaping" the biocidal action of antimicrobial agents. There are phenotypic and genotypic methods used for the identification of antibiotic resistant genes harboring S. aureus but these methods do not always show concordant results. To address these discrepancies, a total of 335 equine nasal swab samples from four districts of Punjab were collected using a convenient sampling technique. These samples were first subjected to common microbial tech...
Immunohistochemical Assessment of GDNF and Chromogranin A Expression in Erosive and Granulomatous Lesions in Glandular Region of Equine Stomach.
Archives of Razi Institute    August 31, 2023   Volume 78, Issue 4 1365-1377 doi: 10.32592/ARI.2023.78.4.1365
Asgari P, Amniattalab A.The equine stomach consists of two separate non-glandular and glandular sections. Despite the incidence of most lesions in the non-glandular region, both stomach parts are prone to lesions. In this study, 41 hybrid-native horses, including 24 stallions and 17 mares, were examined over five years. In total, 27 horses (65.85%) that were sampled had lesions, including erosion, granuloma, or both on the glandular region of the stomach. Occurrence of gastric erosive and granulomatous lesions had no significant relationship with the age and gender of horses or the sampling season (>0.05). Moreove...
A fully automated method to quantitate total carbon dioxide in equine plasma by headspace GCMS.
Drug testing and analysis    August 16, 2022   Volume 14, Issue 10 1724-1731 doi: 10.1002/dta.3353
Zahra PW, Jayasinghe NS, Selvadurai NS, Willers SJ, Krsta D, Batty DC, Vine JH.Pre-race dosing of horses with alkalinising agents to manipulate performance has been evident in racing worldwide for over 30 years. To regulate the use of alkalinising agents, racing authorities adopted thresholds for total plasma carbon dioxide (TCO ) in racehorses. Traditionally, racing laboratories have measured plasma TCO using ion selective electrode (ISE) technology, with the Association of Official Racing Chemists (AORC) approving the use of only three ISE instruments for measurement. Because of the manufacture and support of these instruments ceasing, racing laboratories have explor...
Effects of sample homogenizing on the performance of an automated strongylid egg counting system.
Veterinary parasitology    November 22, 2021   Volume 300 109623 doi: 10.1016/j.vetpar.2021.109623
Nielsen MK, Doran D, Slusarewicz P.Fecal egg counts are essential monitoring tools in veterinary parasite control. In recent years, several groups have developed automated egg counting systems based on image analysis and deep learning algorithms. Work in our laboratory demonstrated that an automated system performed with significantly better precision than traditional egg counting techniques. However, while the counting process is no longer operator dependent, the pre-analytical homogenization steps still are. This study aimed at evaluating the influence of sample homogenization on diagnostic performance on an automated equine ...
Sequential Cerebrospinal Fluid Sampling in Horses: Comparison of Sampling Times and Two Different Collection Sites.
Journal of equine veterinary science    October 14, 2021   Volume 108 103794 doi: 10.1016/j.jevs.2021.103794
Andrade DGA, Cerri FM, Barbosa GVM, Basso RM, Takahira RK, Pantoja JCF, Oliveira-Filho JP, Borges AS.Analysis of the cerebrospinal fluid (CSF) is important as a complementary test in horses with neurologic diseases, and sequential analysis may provide information about the treatment response or evolution and quantitative measures of the CSF drug concentration during treatment. The aim of this study was to compare erythrocyte and nucleated cell counts and protein concentration in multiple CSF samples obtained sequentially from two different puncture sites in clinically healthy horses. Eight and 12 horses, with no evidence of neurologic disease, were subjected to CSF collection from the atlanto...
[Methodical investigation of mineral and trace element concentrations in equine feces with special consideration of the sampling location].
Tierarztliche Praxis. Ausgabe G, Grosstiere/Nutztiere    June 22, 2021   Volume 49, Issue 3 178-188 doi: 10.1055/a-1482-7379
Staufenbiel L, Müller AE, Gehlen H.Objective measurements of the mineral supply in horses are rarely performed. As a result, incorrect elements or an improper amount of elements are provided. The analysis of feces could represent a novel method to evaluate the nutritive supply. The prerequisite is a knowledge of methodological factors influencing the mineral concentration in the fecal samples. Within the scope of this investigation, the effects of different kinds of mineral supply and the influence of the sampling location on the concentration of minerals in equine feces samples were analyzed. Additionally, the methodical error...
Impact of Ambient Temperature Sample Storage on the Equine Fecal Microbiota.
Animals : an open access journal from MDPI    March 15, 2021   Volume 11, Issue 3 819 doi: 10.3390/ani11030819
Martin de Bustamante M, Plummer C, MacNicol J, Gomez D.Sample storage conditions are an important factor in fecal microbiota analyses in general. The objective of this study was to investigate the effect of sample storage at room temperature on the equine fecal microbiota composition. Fecal samples were collected from 11 healthy horses. Each sample was divided into 7 sealed aliquots. One aliquot was immediately frozen at -80 °C; the remaining aliquots were stored at room temperature (21 to 22 °C) with one transferred to the freezer at each of the following time points: 6, 12, 24, 48, 72 and 96 h. The Illumina MiSeq sequencer was used for high-th...
Study design synopsis: Designing and performing pharmacokinetic studies for systemically administered drugs in horses.
Equine veterinary journal    August 5, 2020   Volume 52, Issue 5 643-650 doi: 10.1111/evj.13312
Bermingham E, Davis JL, Whittem T.The goal of this editorial is to discuss best practice design, execution and reporting of a pharmacokinetic (PK) study in horses. Our target readers are clinicians who plan to perform this type of research, in a field, clinic or research setting but we also hope that this article might help readers of such work to appraise the articles and understand the quality of the studies. Our emphasis will be on appropriate study design and analytical method, drug and drug formulation choice and route of administration, animal choice, sample collection, storage and shipping, and reporting, rather than th...
Equine Influenza Diagnosis: Sample Collection and Transport.
Methods in molecular biology (Clifton, N.J.)    March 15, 2020   Volume 2123 361-367 doi: 10.1007/978-1-0716-0346-8_27
Chambers TM, Reedy SE.In horses, presumptive diagnosis of equine influenza is commonly made on the basis of clinical signs. This alone is insufficient for confirmation of equine influenza, because other equine infectious respiratory diseases can in some degree have similar clinical presentations. Surveillance and control of equine influenza also necessitate detection of subclinical cases. Effective diagnosis of equine influenza virus infection is critically dependent on obtaining adequate specimens of virus-containing respiratory secretions for testing. These specimens are also valuable as sources for isolation of ...
Practical Tips on Sample Handling for Hematology, Chemistry, and Cytology Testing for Equine Patients:: Getting More Bang for your Buck.
The Veterinary clinics of North America. Equine practice    January 24, 2020   Volume 36, Issue 1 1-14 doi: 10.1016/j.cveq.2019.12.002
Newman AW.Clinical pathology results are only as good as the quality of samples and accompanying information submitted to the diagnostic laboratory. The frustration of nondiagnostic or equivocal test results can often be avoided by taking the time to follow sample handling and submission guidelines. This article discusses preanalytical errors that commonly affect the accuracy of hematology, chemistry, and cytology testing, and offers practical tips for preventing these errors and maximizing diagnostic yield.
Clinical Pathology of Donkeys and Mules.
The Veterinary clinics of North America. Equine practice    November 2, 2019   Volume 35, Issue 3 433-455 doi: 10.1016/j.cveq.2019.08.002
Goodrich EL, Behling-Kelly E.Given the stoic nature of donkeys and their hybrids, it is important to consider the significance of diagnostic testing modalities that can provide objective health status information beyond the basic physical examination findings. However, clinical pathology assays are also fraught with significant limitations because the results for donkeys, mules, and hinnies can be difficult to interpret, and transference of data from the horse is not always applicable. This article presents considerations for sample collection, storage, analysis, and interpretation strategies for clinical pathology testin...
Presenting and interpreting the results of statistical analyses: Taking sample size into account.
Equine veterinary journal    April 12, 2016   Volume 48, Issue 3 272-274 doi: 10.1111/evj.12566
Christley RM.No abstract available
Hippotherapy acute impact on heart rate variability non-linear dynamics in neurological disorders.
Physiology & behavior    March 15, 2016   Volume 159 88-94 doi: 10.1016/j.physbeh.2016.03.012
Cabiddu R, Borghi-Silva A, Trimer R, Trimer V, Ricci PA, Italiano Monteiro C, Camargo Magalhães Maniglia M, Silva Pereira AM, Rodrigues das Chagas G....Neurological disorders are associated with autonomic dysfunction. Hippotherapy (HT) is a therapy treatment strategy that utilizes a horse in an interdisciplinary approach for the physical and mental rehabilitation of people with physical, mental and/or psychological disabilities. However, no studies have been carried out which evaluated the effects of HT on the autonomic control in these patients. Therefore, the objective of the present study was to investigate the effects of a single HT session on cardiovascular autonomic control by time domain and non-linear analysis of heart rate variabilit...
Evaluation of horse urine sample preparation methods for metabolomics using LC coupled to HRMS.
Bioanalysis    April 8, 2014   Volume 6, Issue 6 785-803 doi: 10.4155/bio.13.324
Stojiljkovic N, Paris A, Garcia P, Popot MA, Bonnaire Y, Tabet JC, Junot C.Horse urine is the medium of choice for the implementation of metabolomic approaches aimed at improving horse doping control. However, drug analysis in this biofluid is a challenging task due to the presence of large amounts of interfering compounds. METHODOLOGY & RESULTS: A comparative study of sample preparation has been conducted to evaluate five sample-preparation methods, namely acetonitrile precipitation, proteinase K hydrolysis, membrane filtration and sample dilution with water by factors of five and 20, for metabolome analysis using liquid chromatography coupled to high resolution...
Doping control analyses in horseracing: a clinician’s guide.
Veterinary journal (London, England : 1997)    January 17, 2014   Volume 200, Issue 1 8-16 doi: 10.1016/j.tvjl.2014.01.006
Wong JK, Wan TS.Doping(1) in sports is highly detrimental, not only to the athletes involved but to the sport itself as well as to the confidence of the spectators and other participants. To protect the integrity of any sport, there must be in place an effective doping control program. In human sports, a 'top-down' and generally unified approach is taken where the rules and regulations against doping for the majority of elite sport events held in any country are governed by the World Anti-Doping Agency (WADA). However, in horseracing, there is no single organisation regulating this form of equestrian sport; i...
Effect of sample handling and storage time on the stability of total CO2 in equine plasma.
Equine veterinary journal. Supplement    March 2, 2013   Issue 43 57-61 doi: 10.1111/j.2042-3306.2012.00610.x
Tinkler SH, Couëtil LL, Constable PD.The stability of total CO2 concentration (ctCO2) in plasma is influenced by storage temperature and handling during sample processing. Conflicting information exists regarding the stability of ctCO2 in equine plasma over time, and the effect of centrifugation on the measured value for plasma ctCO2 is unclear. Objective: To determine plasma ctCO2 stability over 5 days when equine blood is collected into Vacutainer tubes, centrifuged within 30 min of collection, and stored at 4 degrees C; and to determine whether a delay in centrifugation increases the rate at which plasma ctCO2 decreases over t...
The use of a simple backflush technology to improve sample throughput and system robustness in routine gas chromatography tandem mass spectrometry analysis of doping control samples.
Journal of chromatography. A    July 16, 2010   Volume 1217, Issue 28 4749-4752 doi: 10.1016/j.chroma.2010.05.004
Gray BP, Teale P.A simple, low cost system for the backflushing of capillary gas chromatography (GC) columns has been investigated and integrated into a method for the detection of anabolic steroids in equine urine. The modification to the method was simple to make and quick to setup and optimize. The use of backflushing technology was found to offer significant benefits in terms of sample throughput and improved system robustness.
Microbiological sampling of carcasses by excision or swabbing with three types of sponge or gauze.
Journal of food protection    January 7, 2010   Volume 73, Issue 1 81-87 doi: 10.4315/0362-028x-73.1.81
Martínez B, Celda MF, Anastasio B, García I, López-Mendoza MC.Fifty-five bovine, 50 equine, 60 ovine, and 50 porcine carcasses were sampled in a slaughterhouse in eastern Spain. Two samples were taken from each carcass, one using the excision method and the other using the swabbing method. Four different materials were used for swabbing: cellulose, polyurethane, or viscose sponges, and medical gauze. Samples were collected at the end of the process by four different people before the carcasses were taken to the cooler. The samples were examined for total viable bacteria counts (TVCs) and Enterobacteriaceae counts (ECs). The mean TVC for all species sampl...
Evaluation of an air tester for the sampling of aerosolised equine herpesvirus type 1.
The Veterinary record    September 9, 2008   Volume 163, Issue 10 306-308 doi: 10.1136/vr.163.10.306
Pusterla N, Mapes S.No abstract available
Effects of season and sample handling on measurement of plasma alpha-melanocyte-stimulating hormone concentrations in horses and ponies.
American journal of veterinary research    November 30, 2004   Volume 65, Issue 11 1463-1468 doi: 10.2460/ajvr.2004.65.1463
McFarlane D, Donaldson MT, McDonnell SM, Cribb AE.To investigate effects of sample handling, storage, and collection time and season on plasma alpha-melanocyte-stimulating hormone (alpha-MSH) concentration in healthy equids. Methods: 11 healthy Standardbreds and 13 healthy semiferal ponies. Methods: Plasma alpha-MSH concentration was measured by use of radioimmunoassay. Effects of delayed processing were accessed by comparing alpha-MSH concentrations in plasma immediately separated with that of plasma obtained from blood samples that were stored at 4 degrees C for 8 or 48 hours before plasma was separated. Effects of suboptimal handling were ...
Advances in the diagnosis of equine lung disease: sampling from the lower airways.
Equine veterinary journal    May 1, 1990   Volume 22, Issue 3 147-148 doi: 10.1111/j.2042-3306.1990.tb04232.x
Mair TS, Sweeney CR.No abstract available
Radioimmunoassay of thromboxane B2 in horse plasma.
Research in veterinary science    March 1, 1987   Volume 42, Issue 2 150-153 
Cambridge H, Reynoldson JA, Dunsmore JD, Hilbert BJ.A radioimmunoassay for thromboxane B2 (TXB2) in unextracted horse plasma was evaluated. Sensitivity of the assay was 14.0 (SD 5.6) pg ml-1 of plasma. Interassay and intra-assay variation were 21.3 per cent and 4.3 per cent, respectively. The percentage of tracer bound in unextracted plasma in the absence of TXB2 was often higher than that in buffer. Therefore standard curves were obtained using standards diluted in plasma from horses treated with aspirin or in charcoal treated TXB2-free plasma. Standard curves determined in plasma and buffer were parallel. This assay was used to determine the ...
Microprocessor-based system for collection and storage of the equine vectorcardiogram.
American journal of veterinary research    September 1, 1982   Volume 43, Issue 9 1535-1540 
Physick-Sheard PW, Morris WI, Genner D.To evaluate the clinical application of a semiorthogonal lead system for use in the horse, an inexpensive means of recording and storing the ECG was required which would allow the subsequent vectorcardiographic analysis to be computerized. In investigating the various options for the system the basic requirements for the digitization of analogue data were reviewed and previous studies examined. The system subsequently developed used an 8080 microprocessor and a multichannel 8-bit analogue to digital converter. This unit was signal-level compatible with the laboratory recorder used in the study...
Modification of present procedures for the determination of conjugated estrogens (equine) in various low-dosage forms.
Journal - Association of Official Analytical Chemists    September 1, 1972   Volume 55, Issue 5 1070-1073 
Allen RG.The presently used procedures for the colorimetric determination of conjugated estrogens (equine) have been modified for the assay of tablets, capsules, liquids, and creams of low declaration per dosage unit. Modifications in sample chromatographic column preparation and elution have provided a more efficient extraction of the steroids.